首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 27 毫秒
1.
A CE method utilizing triple quadrupole electrospray (ES) MS (MS/MS) detection was developed and validated for the simultaneous measurement of nucleoside 5'-triphosphate and 5'-monophosphate anabolites of the anti-HIV (human immunodeficiency virus) didanosine (ddAMP, ddATP) and stavudine (d4TMP, d4TTP), among a pool of 14 endogenous 5'-mono-, di-, and triphosphate nucleosides. These compounds were spiked and extracted from peripheral blood mononuclear cells (PBMCs) which are the sites of HIV replication and drug action. An acetic acid/ammonia buffer (pH 10, ionic strength of 40 mM) was selected as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of +30 kV and an overimposed pressure of 28 mbar (0.4 psi). The application of pressure assistance was needed to provide stable ES conditions for successful coupling. The coupling was carried out with a modified sheath-flow interface, with one uninterrupted capillary (80 cmx 50 microm id; 192 microm od) in a dimension that fits into the ESI needle to get a stable ion spray. Some CE-MS parameters such as overimposed pressure, sheath-liquid composition, sheath-liquid and sheath-gas flow rates, ES voltage, and the CE capillary position were optimized in order to obtain an optimal sensitivity. The use of perfluorinated alcohols and acids in the coaxial sheath-liquid make-up (2,2,2-trifluoroethanol + 0.2 mM tridecafluoroheptanoic acid) appeared to provide the best MS sensitivity and improve the stability of spray. The linearity of the CE-MS and CE-MS/MS methods was checked under these conditions. Validation parameters such as accuracy, intraday and interday precision, and LOQs were determined in CE-MS/MS mode. Finally, the quantitation of d4T-TP and ddA-TP was validated in this CE-MS/MS system.  相似文献   

2.
A simple and rapid determination of two Amadori compounds in cigarettes, 1-deoxy-1-L-proline-D-fructose (Fru-Pro) and 1-deoxy-1-L-alanine-D-fructose (Fru-Ala), which are the important intermediates in Maillard reaction, was achieved by HPLC-MS/MS. Eighty-eight commercial brand cigarettes of 5 different styles were employed to investigate their diversities on Fru-Pro and Fru-Ala. The contents of Fru-Pro and Fru-Ala in all cigarette samples correlate with each other. Comparison of the contents of two compounds reveals a substantial difference for different cigarettes: the contents of the two Amadori compounds in Chinese flue-cured cigarettes are remarkably higher than in British flue-cured, American, Japanese and Chinese blend cigarettes. This might be beneficial for using these two compounds as characteristic markers to identify the flavor-specific Chinese flue-cured cigarettes.  相似文献   

3.
A generic approach has been developed for coupling capillary electrophoresis (CE) using non-volatile background electrolytes (BGEs) with mass spectrometry (MS) using a sheath liquid interface. CE-MS has been applied for basic and bi-functional compounds using a BGE consisting of 100 mM of TRIS adjusted to pH 2.5 using phosphoric acid. A liquid sheath effect is observed which may influence the CZE separation and hence may complicate the correlation between CE-UV and CE-MS methods. The influence of the liquid sheath effect on the migration behavior of basic pharmaceuticals has been studied by simulation experiments, in which the BGE outlet vial is replaced by sheath liquid in a CE-UV experiment. As a consequence of the liquid sheath effect, phosphate based BGEs can be used without significant loss of MS sensitivity compared to volatile BGEs. The use of buffer constituents such as TRIS can lead to lower detection limits as loss of MS sensitivity can be compensated by better CE performance. TRIS based BGEs permit relatively high injection amounts of about 100 pmol while maintaining high resolution. The ESI-MS parameters were optimized for a generic method with maximum sensitivity and stable operation, in which the composition of the sheath liquid and the position of the capillary were found to be important. Furthermore, the nebulizing pressure strongly influenced the separation efficiency. The system showed stable performance for several days and a reproducibility of about 15% RSD in peak area has been obtained. Nearly all test compounds used in this study could be analyzed with an MS detection limit of 0.05% measured in scan mode using extracted ion chromatograms. As a result, CE-MS was found to be a valuable analytical tool for pharmaceutical impurity profiling.  相似文献   

4.
Capillary electrophoresis (CE) mass spectrometry (MS), with its ability to separate compounds present in extremely small volume samples rapidly, with high separation efficiency, and with compound identification capability based on molecular weight, is an extremely valuable analytical technique for the analysis of complex biological mixtures. The highest sensitivities and separation efficiencies are usually achieved by using narrow capillaries (5-50 micro m i.d.) and by using sheathless CE-to-MS interfaces. The difficulties in CE-to-MS interfacing and the limited loadability of these narrow columns, however, have prevented CE-MS from becoming a widely used analytical technique. To remedy these limitations, several CE-MS interfacing techniques have recently been introduced. While electrospray ionization is the most commonly used ionization technique for interfacing CE-to-MS, matrix assisted laser desorption ionization has also been used, using both on-line and off-line techniques. Moreover, the high concentration detection limit of CE has been addressed by development of several sample concentration and sample focusing methods. In addition, a wide variety of techniques such as capillary zone electrophoresis, capillary isoelectric focusing, and on-column transient isotachophoresis have now been interfaced to MS. These advances have resulted in a rapid increase in the use of CE-MS in the analysis of complex biological mixtures. CE-MS has now been successfully applied to the analysis of a wide variety of compounds including amino acids, protein digests, protein mixtures, single cells, oligonucleotides, and various small molecules relevant to the pharmaceutical industry.  相似文献   

5.
The depository effects that occur in slowly metabolized proteins (typically glycation) are very difficult to assess, owing to their extremely low concentration in the protein matrix. Collagen accumulates reactive metabolites through reactions that are not regulated by enzymes. A typical example of these non-enzymatic changes is glycation (the Maillard reaction, the formation of advanced glycation end products), resulting from the reaction of the oxo-group of sugars with the epsilon-amino group of lysine and arginine. Collagen samples (type I) as a test protein were incubated separately with glucose, ribose and malondialdehyde. Collagen was fragmented with cyanogen bromide and then digested with trypsin. This peptide digest was separated by CE, CE-MS/MS, and HPLC-MS/MS. An ion trap MS was used and MS conditions were optimized for both methods. These on-line CE-MS/MS and HPLC-MS/MS couplings made it possible to discover specific modifications such as (N(epsilon)-(carboxymethyl)-lysine) in the precise location in the structure of collagen corresponding to posttranslational non-enzymatic modifications. A new CE-MS/MS technique for peptide analysis was developed, and applied in the identification of posttranslational modifications in slowly metabolized test proteins.  相似文献   

6.
CE-MS is a successful proteomic platform for the definition of biomarkers in different body fluids. Besides the biomarker defining experimental parameters, CE migration time and molecular weight, especially biomarker's sequence identity is an indispensable cornerstone for deeper insights into the pathophysiological pathways of diseases or for made-to-measure therapeutic drug design. Therefore, this report presents a detailed discussion of different peptide sequencing platforms consisting of high performance separation method either coupled on-line or off-line to different MS/MS devices, such as MALDI-TOF-TOF, ESI-IT, ESI-QTOF and Fourier transform ion cyclotron resonance, for sequencing indicative peptides. This comparison demonstrates the unique feature of CE-MS technology to serve as a reliable basis for the assignment of peptide sequence data obtained using different separation MS/MS methods to the biomarker defining parameters, CE migration time and molecular weight. Discovery of potential biomarkers by CE-MS enables sequence analysis via MS/MS with platform-independent sample separation. This is due to the fact that the number of basic and neutral polar amino acids of biomarkers sequences distinctly correlates with their CE-MS migration time/molecular weight coordinates. This uniqueness facilitates the independent entry of different sequencing platforms for peptide sequencing of CE-MS-defined biomarkers from highly complex mixtures.  相似文献   

7.
CE coupled to MS has proven to be a powerful analytical tool for the characterization of intact proteins, as it combines the high separation efficiency of CE with the selectivity of MS. This review provides an overview of the development and application of CE-MS methods within the field of intact protein analysis as published between January 2007 and June 2010. Ongoing technological developments with respect to CE-MS interfacing, capillary coatings for CE-MS, coupling of CIEF with MS and chip-based CE-MS are treated. Furthermore, CE-MS of intact proteins involving ESI, MALDI and ICP ionization is outlined and overviews of the use of the various CE-MS methods are provided by tables. Representative examples illustrate the applicability of CE-MS for the characterization of proteins, including glycoproteins, biopharmaceuticals, protein-ligand complexes, biomarkers and dietary proteins. It is concluded that CE-MS is a valuable technique with high potential for intact protein analysis, providing useful information on protein identity and purity, including modifications and degradation products.  相似文献   

8.
Monitoring of amphetamines and designer drugs in human urine is a timely topic in clinical toxicology, surveillance of drug substitution, forensic science, drug testing at the workplace, and doping control. Confirmation testing of urinary amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) and 3,4-methylenedioxyamphetamine (MDA) by capillary electrophoresis (CE) combined with atmospheric pressure electrospray ionization and ion trap mass spectrometry (MS) is described. Using an aqueous pH 4.6 buffer composed of ammonium acetate/acetic acid, CE-MS and CE-MS2 provided data that permitted the unambiguous confirmation of these drugs in external quality control urines. Furthermore, other drugs of abuse present in alkaline urinary extracts, including methadone and morphine, could also be monitored. The data presented illustrate that the sensitivity achieved with the benchtop MS is comparable to that observed by CE with UV absorption detection. CE-MS2 is further shown to be capable of identifying comigrating compounds, including the comigration of amphetamine with nicotine.  相似文献   

9.
To simplify capillary electrophoresis-mass spectrometry (CE-MS) operation, a background electrolyte (BGE) containing a polymer additive is introduced that allows the analysis of peptides and protein mixtures in underivatized fused-silica capillaries without any pretreatment, thereby increasing throughput. The most important characteristic of these polymer additives is that they do not significantly suppress the signals of the proteins and peptides under electrospray ionization, thereby allowing them to be used as an additive to common BGEs that are used for CE-MS analysis of peptide and protein mixtures. In addition, because the fused-silica capillary inner wall is continuously coated with the polymer additive, migration irreproducibility, due to the degradation of the capillary inner wall coating, under CE-MS is minimized. High sensitivity of detection, migration reproducibility, and ease of fabrication allow CE-MS analyses that require long analysis time, such as (CE-MS/MS)n, to be performed with ease. The utility of this background electrolyte has been demonstrated for the analysis of complex protein digests and intact proteins.  相似文献   

10.
The combination of capillary electrophoresis (CE) and mass spectrometry (MS) is particularly well adapted to bioanalysis due to its high separation efficiency, selectivity, and sensitivity; its short analytical time; and its low solvent and sample consumption. For clinical and forensic toxicology, a two-step analysis is usually performed: first, a screening step for compound identification, and second, confirmation and/or accurate quantitation in cases of presumed positive results. In this study, a fast and sensitive CE-MS workflow was developed for the screening and quantitation of drugs of abuse in urine samples. A CE with a time-of-flight MS (CE-TOF/MS) screening method was developed using a simple urine dilution and on-line sample preconcentration with pH-mediated stacking. The sample stacking allowed for a high loading capacity (20.5% of the capillary length), leading to limits of detection as low as 2 ng mL−1 for drugs of abuse. Compound quantitation of positive samples was performed by CE-MS/MS with a triple quadrupole MS equipped with an adapted triple-tube sprayer and an electrospray ionization (ESI) source. The CE-ESI-MS/MS method was validated for two model compounds, cocaine (COC) and methadone (MTD), according to the Guidance of the Food and Drug Administration. The quantitative performance was evaluated for selectivity, response function, the lower limit of quantitation, trueness, precision, and accuracy. COC and MTD detection in urine samples was determined to be accurate over the range of 10–1000 ng mL−1 and 21–1000 ng mL−1, respectively.  相似文献   

11.
Application of capillary electrophoresis (CE) in combination with mass spectrometry (MS) and tandem MS to glycoscreening in biomedical projects is highlighted. In the first part recent CE-MS experiments by sheath liquid CE and multiple stage MS are reported. Neutral and negatively charged N-glycan mixtures from ribonuclease B and fetuin, high-mannose type N-glycoforms, oligosaccharides from lipopolysaccharides (LPS) of Haemophilus influenzae, polysaccharides of Pseudomonas aeruginosa and Staphylococcus aureus were analyzed. A particular emphasis is devoted to the applicability of novel off- and on-line CE-MS and tandem MS methods for screening of proteoglycan-derived oligosaccharides, glycosaminoglycans (GAGs), such as hyaluronates from Streptococcus agalactiae, chondroitin/dermatan sulfates (CS/DS) from bovine aorta and human skin fibroblast decorin, and heparin/heparan sulfate (HS) from porcine and bovine mucosa. The performance of CE-MS/MS for identification of glycoforms in glycopeptides and glycoproteins is illustrated by experiments performed on complex mixtures from urine of patients suffering from a hereditary N-acetylhexosaminidase deficiency (Schindler's disease) and urine of patients suffering from cancer cachexia. For determination of glycosylation patterns in glycoproteins like enzymes and antibodies by CE/MS, both CE-matrix assisted laser desorption/ionization (MALDI) and CE-electrospray ionization (ESI)-MS were functional. Finally, the potential of CE-ESI-MS strategy in glycolipid analysis is demonstrated for gangliosides from bovine brain for which particular CE buffer conditions are required.  相似文献   

12.
Summary Reversed-phase high-performance liquid chromatography-mass spectroscopy (HPLC-MS) and capillary electrophoresis-mass spectroscopy (CE-MS) have been compared for the analysis of phenolic compounds in diethyl ether extracts of red wines. MS was performed in the electrospray negative-ionization mode. Despite the much higher separation efficiency of CE compared with LC, LC-MS furnishes far superior information for elucidation of the structure of the constituents. LC-MS enabled the identification of twenty-four compounds whereas only thirteen were characterized by CE-MS.  相似文献   

13.
Host cell proteins (HCPs) are widely regarded as a critical quality attribute for a biotherapeutic product. Bottom up MS is the present gold standard for HCP analysis but suffers from incomplete protein identification due to complex nature of the HCP mixture and limited separation efficiency of the preceding LC-based systems. In this paper, we present for the first time an application involving use of LC-CE-MS/MS platform for analysis of HCPs. It has been demonstrated that the proposed platform has been able to successfully identify 397 HCPs from the supernatants of recombinant Chinese hamster ovary cells, twice and thrice the number of proteins identified by the state-of-the-art LC-MS/MS (189 HCPs) and CE-MS/MS (128 HCPs) analyses, respectively. Of these, 225 HCPs were unique to the LC-CE-MS/MS approach and were not identified by either LC-MS/MS or CE-MS/MS. It is observed that the LC-CE-MS/MS platform combines the benefits of LC-MS/MS and CE-MS/MS techniques and identifies peptides in a wider range of size, pI, and hydrophobicity. Additionally, LC-CE-MS/MS also identified more HCPs associated with cellular components, molecular functions, biological processes, peptidases, and secretory proteins. The proposed approach would thus be a useful addition in HCP analysis and secretome studies of mAb-producing Chinese hamster ovary cells.  相似文献   

14.
The sol-gel method is a widely used technique for the synthesis of various functional coating films. Alkoxysilanes such as (3-methacryloxypropyl)trimethoxysilane (MEMO) are largely used as precursors for inorganic-organic hybrid sol-gel materials. Indeed, these compounds can form complex network, through hydrolysis and condensation reactions. The latter have to be perfectly controlled to obtain the required properties. In such a context, we have studied the potentialities of capillary electrophoresis-ion-trap mass spectrometry (CE-MS) coupling to resolve both separation and characterization of the synthesized compounds as a function of the hydrolysis time. The study of acid hydrolysis of MEMO was carried out as an example. After optimization of the running electrolyte in capillary zone electrophoresis (CZE) with UV detection, we characterized the synthesized compounds in CE-MS by using positive detection mode. The obtained resolution in CZE-UV was not entirely satisfactory because of the very closed charge/mass ratio of formed solute but also because of the interaction between the solutes and the capillary walls. Nevertheless, several oligomers were characterized in CE-MS. The absence of detection with regard to oligomers that possess higher molecular masses than octamer is discussed in this work.  相似文献   

15.
The well known biospecific noncovalent receptor-ligand association complexes between the immunophilin FKBP and the immunosuppressive drugs FK506 and Rapamycin (RM) were investigated by on-line capillary electrophoresis-mass spectrometry (CE-MS) under selected ion monitoring (SIM) conditions and by CE-MS with tandem mass spectrometry (CE-MS/MS) under selected reaction monitoring (SRM) conditions. Solutions of hFKBP (33.3 µM) were dissolved in 50 mM ammonium acetate at pH 7.5. Samples that contained 100 µM of FK506 or RM also were prepared under the same solution conditions. By using these aqueous pH neutral conditions, samples were analyzed by SIM CE-MS and SRM CE-MS and the target complexes were separated by CE with mass spectrometer detection of the individual complexes between FKBP and FK506 [hFKBP + FK506 + 7HJ7+ as well as FKBP and RM [hFKBP + RM + 7HJ7+. In an experiment where a mixture of FK506 and RM was analyzed in the presence of FKBP, a nine-to-one ratio of ion current abundances between the RM and FK506 complexes was observed as reported in the literature from other studies. These results suggest that CE-MS and CE-MS/MS may be yet another analytical method for studying noncovalent interactions of biologically important macromolecules under physiological conditions.  相似文献   

16.
This review provides an update of the state-of-the-art of CE-MS for metabolomic purposes, covering the scientific literature from July 2008 to June 2010. This review describes the different analytical aspects with respect to non-targeted and targeted metabolomics and the new technological developments used in CE-MS for metabolomics. The applicability of CE-MS in metabolomics research is illustrated by examples of the analysis of biomedical and clinical samples, and for bacterial and plant extracts. The relevant papers on CE-MS for metabolomics are comprehensively summarized in a table, including, e.g. information on sample type and pretreatment, and MS detection mode. Future considerations such as challenges for large-scale and (quantitative) clinical metabolomics studies and the use of sheathless interfacing and different ionization techniques are discussed.  相似文献   

17.
梁玉  张丽华  张玉奎 《色谱》2020,38(10):1117-1124
蛋白质组学研究在生物学、精准医学等方面发挥着重要的作用。然而研究面临的巨大挑战来自生物样品的复杂性,因此在质谱(MS)鉴定技术不断革新的同时,发展分离技术以降低样品复杂度尤为重要。毛细管电泳(CE)技术具有上样体积小、分离效率高、分离速度快等优势,其与质谱的联用在蛋白质组学研究中越来越受到关注。低流速鞘流液和无鞘流液接口的发展及商品化推动了CE-MS技术的发展。目前毛细管区带电泳(CZE)、毛细管等电聚焦(CIEF)、毛细管电色谱(CEC)等分离模式已与质谱联用,其中CZE-MS应用最广泛。目前被广泛采用的蛋白质组学研究策略主要是基于酶解肽段分离鉴定的"自下而上(bottom-up)"策略。首先,CE-MS技术对酶解肽段的检测灵敏度高达1 zmol,已成功应用于单细胞蛋白质组学;其次,毛细管电泳技术与反相液相色谱互补,为疏水性质相近的肽段(尤其是翻译后修饰肽段)的分离鉴定提供了新的途径。基于整体蛋白质分离鉴定的自上而下"top-down"策略可以直接获得更精准、更完整的蛋白质信息。CE技术在蛋白质大分子的分离方面具有分离效率高、回收率高的优势,其与质谱的联用提高了整体蛋白质的鉴定灵敏度和覆盖度。非变性质谱(native MS)是一种在近生理条件下从完整蛋白质复合物水平上进行分析的质谱技术。CE与非变性质谱联用已被尝试用于蛋白质复合体的分离鉴定。该文引用了与CE-MS和蛋白质组学应用相关的93篇文献,综述了以上介绍的CE-MS的研究进展以及在蛋白质组学分析中的应用优势,并总结和展望了其应用前景。  相似文献   

18.
CZE is an appropriate technique for separating charged species, but lacks selectivity for neutral compounds. Alternative approaches such as microemulsion electrokinetic chromatography (MEEKC) have been developed to broaden its range of applications. Hyphenation of MEEKC with MS is an attractive perspective since it can enhance sensitivity and selectivity. The on-line coupling of MEEKC with MS, however, is not straightforward due to the low compatibility of non-volatile surfactant additives (e.g. SDS) and the commonly used API source, namely ESI. In order to hyphenate MEEKC with MS detection, the atmospheric pressure photoionization (APPI) source was investigated. Possibilities offered by the coupling of MEEKC with APPI-MS were highlighted for the complex separation of ionized and neutral compounds in both the positive and negative modes. MEEKC-APPI-MS performance, in terms of selectivity, efficiency and sensitivity was compared to CZE-ESI-MS and MEEKC-ESI-MS for the screening of doping substances (beta-blockers, central stimulants, diuretics, etc). Relevant selectivity and detectability, particularly for neutral, structurally related and isobaric compounds was demonstrated with the MEEKC-APPI-MS approach opening new avenues for CE-MS, in addition to the well-established CZE-ESI-MS technique.  相似文献   

19.
Analyses of alkaloids in different products by NACE-MS   总被引:1,自引:0,他引:1  
Chiu CW  Liang HH  Huang HY 《Electrophoresis》2007,28(22):4220-4226
A simple method for the separation and characterization of five nicotine-related alkaloids by NACE employing UV and MS detections is described here for the first time. Several factors, including NACE parameters (compositions of running solution) and MS parameters (such as nature and flow rate of sheath liquid, pressure of nebulization gas, and flow rate of dry gas), were optimized in order to obtain both an adequate CE separation and high MS signals for the alkaloid compounds used in this study. A reliable CE separation of five alkaloids was achieved in 50 mM ammonium formate that was dissolved in an ACN/methanol mixture (50:50, v/v) of pH* 4.0 (apparent pH 4.0). The optimal electrospray MS measurement was carried out in the positive ionization mode using a coaxial sheath liquid composed of isopropyl alcohol and water in the ratio of 80:20 v/v at a flow rate of 180 microL/h. In addition, the proposed NACE method was also applied in the analyses of alkaloids in several products including chewing gums, beverages, and tobaccos. This NACE-MS method was found to provide a better detection ability and separation resolution for the analysis of nicotine alkaloids when compared to other aqueous CE-MS reports.  相似文献   

20.
王红瑞  谢媛媛  梁琼麟  王义明  胡坪  罗国安 《色谱》2013,31(12):1189-1193
建立了高效液相色谱-三重四极杆质谱(HPLC-QqQ MS)联用定量分析烟草中5种Amadori前香物质的方法。样品经含5%(v/v)甲醇的水提取后,采用Waters XBridgeTM Amide色谱柱(250 mm×4.6 mm,3.5 μm)、以甲醇-水为流动相进行分离,采用多反应监测(MRM)模式测定烟草样品中5种Amadori化合物的含量。结果表明,5种Amadori化合物的峰面积与质量浓度的线性关系良好,相关系数r为0.9895~0.9989;定量限(S/N=10)在10.18~44.58 μg/L,检出限(S/N=3)在3.51~14.86 μg/L;平均加标回收率为92.6%~123.6%,相对标准偏差(RSD)小于9.4%。本方法操作简便、灵敏度高、分析速度快,可以用于烟叶及卷烟中5种主要Amadori类物质的含量测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号