首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
J. Galceran  C. Huidobro  G. Alberti 《Talanta》2007,71(4):1795-1803
Absence of Gradients and Nernstian Equilibrium Stripping (AGNES) is a recently suggested electroanalytical technique designed for the determination of the free concentration of heavy metals (such as Zn, Cd or Pb) which is here developed and applied to seawater samples. A key improvement for the implementation of AGNES with complex matrices is the development of a new blank, called the shifted blank (presented in this work for the first time), which can be applied to the same sample where the measurement is intended. The careful selection of the required parameters for the determination of the free Zn concentration (or activity) at the nanomolar level is described in detail. The methodology has been validated with a synthetic solution containing Zn and nitrilotriacetic acid (NTA) and then applied, as a first case, to two coastal seawater samples taken close to Barcelona and Tarragona (Catalonia, North-Eastern Spain) finding values in the range of 1-3 nM, representing around 25% of total Zn. This technique can, in the near future, be crucial in helping to elucidate the role of the free zinc(II) concentration in natural waters.  相似文献   

2.
Zinc (Zn) has been classified as a “Specific Pollutant” under Annex VIII of the EU Water Framework Directive by two thirds of the EU member states. As a result, the UK Environmental Quality Standard (EQS) for Transitional and Coastal (TrAC) Waters has been reduced from 612 nM to 121 nM total dissolved Zn. It is widely accepted that the free metal ion ([Zn2+]) is the most bioavailable fraction, but there are few techniques available to determine its concentration in these waters. In this work, Absence of Gradients and Nernstian Equilibrium Stripping (AGNES) has been applied, for the first time, to determine [Zn2+] in estuarine waters. The AGNES method had a mean RSD of ±18%, a (deposition time dependent) limit of detection of 0.73 nM and a [Zn2+] recovery of 112 ± 19% from a certified reference material (BCR-505; Estuarine Water). AGNES results for 13 estuarine samples (salinity 0.1–31.9) compared well (P = 0.02) with Competitive Ligand Exchange Cathodic Stripping Voltammetry (CLE-AdCSV) except for one sample. AGNES requires minimal sample manipulation, is unaffected by adsorption of interfering species at the electrode surface and allows direct determination of free zinc ion concentrations. Therefore AGNES results can be used in conjunction with ecotoxicological studies and speciation modelling to set and test compliance with water quality standards.  相似文献   

3.
AGNES (Absence of Gradients and Nernstian Equilibrium Stripping) has been implemented with screen‐printed electrodes (SPE) for the determination of the free concentration of Zn2+, Cd2+ and Pb2+. For SPE, the stripped charge is a suitable response function which does not require the second stage of AGNES to be under diffusion limited conditions. This property can be used in the avoiding of the interference of Pb on [Cd2+] determination. The proportionality factor between stripped charge and concentration of amalgamated metal depends on the volume of mercury and opens the way to a future calibrationless strategy. Zn and Cd complexation with oxalate at various pH‐values confirms the suitability of the developed methodology, which compares favourable with the standard one based on the Hanging Mercury Drop Electrode.  相似文献   

4.
The free metal ion concentration and the dynamic features of the metal species are recognized as key to predict metal bioavailability and toxicity to aquatic organisms. Quantification of the former is, however, still challenging. In this paper, it is shown for the first time that the concentration of free copper (Cu2+) can be quantified by applying AGNES (Absence of Gradients and Nernstian equilibrium stripping) at a solid gold electrode. It was found that: i) the amount of deposited Cu follows a Nernstian relationship with the applied deposition potential, and ii) the stripping signal is linearly related with the free metal ion concentration. The performance of AGNES at the vibrating gold microwire electrode (VGME) was assessed for two labile systems: Cu-malonic acid and Cu-iminodiacetic acid at ionic strength 0.01 M and a range of pH values from 4.0 to 6.0. The free Cu concentrations and conditional stability constants obtained by AGNES were in good agreement with stripping scanned voltammetry and thermodynamic theoretical predictions obtained by Visual MinteQ. This work highlights the suitability of gold electrodes for the quantification of free metal ion concentrations by AGNES. It also strongly suggests that other solid electrodes may be well appropriate for such task. This new application of AGNES is a first step towards a range of applications for a number of metals in speciation, toxicological and environmental studies for the direct determination of the key parameter that is the free metal ion concentration.  相似文献   

5.
The electroanalytical technique Absence of Gradients and Nernstian Equilibrium Stripping (AGNES) has been extended by applying stripping chronopotentiometry (SCP) as the re-oxidation stage in the determination of the free concentration of Zn(2+), Cd(2+) and Pb(2+). This new approach, called AGNES-SCP, has been implemented with screen-printed electrodes (SPE) and the standard Hanging Mercury Drop Electrode (HMDE). Clear advantages of this variant have been shown: (i) the easy resolution of the peaks of different metals present in mixtures and (ii) the sparing of blanks. A rigorous computation of the faradaic charge along the SCP stage takes into account the contribution of other oxidants, which can be efficiently measured at the end of the deposition stage of AGNES. The free Cd concentration determined in an oxalate solution at pH 6 with an HMDE as the working electrode agreed well with values obtained with a Cd Ion Selective Electrode. The free metal concentration measured using an SPE for the system Cd and nitrilotriacetic acid (NTA) at pH = 4.8 also conformed well with Visual MINTEQ results.  相似文献   

6.

A modified LED fluorimetry determination of uranium in Nb/Ta minerals has been developed. The mineral is brought into solution by fusion with mixed phosphate flux (NaH2PO4, H2O and Na2HPO4). Iron quenches uranium fluorescence when it is present above the ratio of (iron to uranium) 100. Uranium is separated in ethyl acetate by solvent extraction and then stripped back into pyrophosphate buffer (pH ~ 7) prior to its LED fluorimetry determination. This modified method has been applied for the determination of uranium in synthetic mixtures and Nb/Ta minerals including Certified Reference Materials (X1807) with high degree of accuracy and precision.

  相似文献   

7.
In this work, bamboo charcoal (BC) was used as a sorbent for on-line solid phase extraction (SPE) coupling with flame atomic absorption spectrometry (AAS) for trace copper and zinc determination in environmental and biological samples. Under the optimum pH of 5.5 (for Zn) and 7.0 (for Cu), trace copper and zinc were effectively adsorbed on the microcolumn and the retained cations were efficiently eluted with HCl or HNO3 with an appropriate concentration and flow rate for on-line AAS determination. With a sample loading time of 60 s at a sample flow rate of 7.6 mL min?1, the enhancement factors of 39 (for Cu) and 30 (for Zn) and detection limits (3σ) of 0.60 µg L?1 (for Cu) and 0.36 µg L?1 (for Zn), respectively, were achieved. The sample throughput was 45 h?1. At the level of 20 µg L?1of Cu(II) and Zn(II), the precision (RSD, n?=?11) were found to be 0.26% and 1.6%, respectively. The proposed method has been successfully applied to the determination of copper and zinc in environmental and biological samples.  相似文献   

8.
A solid phase extraction method for the determination of Cu(II), Mn(II) and Zn(II) metal ions in natural water and leafy vegetable samples by ICP-AES was developed. The method was based on the sorption of metal ions onto Amberlite XAD-16 functionalized with a new chelating ligand potassium 2-benzoylhydrazinecarbodithioate (Amberlite XAD-16-PBHCD) and elution with nitric acid. The optimum experimental conditions for the quantitative sorption of the three metal ions, namely, effect of pH, sample volume, flow rate, concentration of eluent, sorption capacity, kinetics of sorption, and the effect of diverse ions on the sorption of analytes have been investigated. All the metal ions were quantitatively retained by the functionalized resin at pH 5.0 and sorbed metals could be eluted with 2.0?M HNO3. The detection limits were 5.6, 4.5 and 1.8?µg?L?1 for Cu(II), Mn(II) and Zn(II), respectively. The developed method was applied for the determination of Cu(II), Mn(II) and Zn(II) in water and leafy vegetable samples.  相似文献   

9.
A method is proposed for the extractive spectrophotometric determination of uranium(VI) using the synergic combination of ethyl acetoacetate (EAA) and pyridine (Py) as extractants. The optimum conditions have been evaluated by varying pH and ethyl acetoacetate and pyridine concentration. The nature of the extracted species has been determined by 1g D-1g C plots and the extracted species was found to be UO2(EAA)2.Py. The method has been applied for the separation and determination of uranium(VI) from synthetic mixtures.  相似文献   

10.
《Analytical letters》2012,45(12):2201-2219
Abstract

A new on-line precolumn preconcentration method for the determination of EPA priority pollutants (PAHs) in river and sea water has been developed. The retention time for each PAH in the precolumn has been determined for several percentages of organic solvent (acetonitrile) in the sample. This is very important because recoveries show a great dependence on this parameter.

The proposed procedure, combined with HPLC and spectrofluorimetric detection, reaches very low detection limits (subnanograms per liter) and it has been applied to river and sea water samples with good results.  相似文献   

11.
In the present work, the applicability of thin mercury film on a rotating disk electrode (TMF-RDE), to assess the free metal ion concentration by the absence of gradients and Nernstian equilibrium stripping (AGNES), is evaluated. The thickness of the mercury film and several AGNES parameters has been optimized. A nominal 16 nm film is chosen due to the higher signal (faradaic current) relative to the value of the noise (capacitive current). Due to the smaller volume to area ratio, the deposition time needed to reach a certain preconcentration factor (Y) is much shorter than in larger electrodes, like the HMDE. The limit of detection (3σ) for lead(II) is 7.4 × 10−9 M and 7.2 × 10−8 M for a Y of 5000 (deposition time of 150 s) and 1000 (deposition time of 100 s), respectively. A specific mathematical treatment is developed in order to subtract a corrected blank taking into account the degradation of the thin film (presumably, falling down of drops). The couple TMF-RDE/AGNES is successfully applied for speciation purposes in the systems Pb(II)-latex nanospheres and Pb(II)-IDA (iminodiacetic acid), where the stability constants calculated for both systems agree with values reported in the literature.  相似文献   

12.
Lunvongsa S  Oshima M  Motomizu S 《Talanta》2006,68(3):969-973
A flow injection spectrophotometric method has been developed for the determination of dissolved and total amounts of iron in tap and natural water samples. The method for the determination of iron employs a sample acidification step in order to decompose iron hydroxide and iron-complexes into free iron, Fe(III) and Fe(II). The amounts of free iron were detected using a catalytic action of Fe(III) and Fe(II) on the oxidation of N,N-dimethyl-p-phenylenediamine in the presence of hydrogen peroxide. Increase in absorbance of oxidized product was detected spectrophotometrically at 514 nm. The proposed method allows 0.02 and 0.06 μg l−1 of LOD and LOQ, respectively, with relative standard deviation (RSD) below 2%. The accuracy and the precision of the method were evaluated by the analysis of the standard reference material, river water. The developed method was successfully applied to real water samples.  相似文献   

13.
《Analytical letters》2012,45(6):1209-1226
Abstract

A sensitive method for the simultaneous spectrophotometric determination of Fe(II), Cu(II), Zn(II), and Mn(II) in mixtures has been developed with the aid of multivariate calibration methods, such as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS). The method is based on the spectral differences of the analytes in their complexation reaction with 4‐(2‐pyridylazo)‐resorcinol (PAR) and the use of full spectra with wavelengths in the range of 300–600 nm. It was found that both the spectral positive and negative bands obtained against the PAR blank, are proportional to the concentration for each metal complex. The obtained linear calibration concentration ranges are 0.025–0.6, 0.05–0.8, 0.025–0.8, and 0.05–0.8 µg ml?1 for Fe(II), Cu(II), Zn(II), and Mn(II), respectively, and the LODs for the four metal ions were found to be approximately 1–3×10?2 µg ml?1. The proposed method was applied to a verification set of synthetic mixtures of these four metal ions, with models built in three different wavelength ranges, i.e., 300–450, 450–600, and 300–600 nm, corresponding to the positive, negative bands and their combinations, respectively. It was shown that the PLS model for the 300–600 nm range gave the best results (RPET=6.9% and average recovery ~100%; cf. PCR: RPET=9.5% and average Recovery ~110%). This method was also successfully applied for the determination of the four metal ions in pharmaceutical preparations, chicken feedstuff, and water samples.  相似文献   

14.
A silica-based inorganic sorbent was synthesized by the thermal decomposition of ammonium heptamolybdate on silica and applied for the preconcentration and simultaneous determination of Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb in river water samples using a column system with flame atomic absorption spectrometry. Attenuated total reflection-Fourier transformation infrared spectroscopy, scanning electron microscopy, and electron dispersive spectroscopy were used for sorbent characterization. The effects of pH, sample volume, eluent type, eluent concentration, eluent volume, sample flow rate, and matrix ions (Al, Bi, Ca, Mg, and Zn) on the recovery of the metals in model solutions were investigated. The adsorption capacities (µmol g?1) of SiO2-MoO3 were 88.96 (Cd), 169.69 (Co), 153.85 (Cr), 188.88 (Cu), 179.05 (Fe), 163.81 (Mn), 136.31 (Ni), and 38.61 (Pb). The detection limits of the method were 9.09, 10.82, 10.77, 49.57, 31.64, 6.40, 8.86, 19.15?µg L?1 for Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb, respectively, with a preconcentration factor of 25. The developed method was used for the determination of the target metals in real samples and the recoveries for spiked samples were found to be from 91.2% to 102.9%.  相似文献   

15.
《Analytical letters》2012,45(4):347-354
Abstract

A method for the determination of impurities in 233UO2 has been developed and applied to the analysis of a product stream of ceramic grade 233UO2 powder. The analytical method has combined isotope dilution and internal standard methods to permit the determination of impurities at concentrations between 0.1 and 500 ppm in a single sample.  相似文献   

16.
A procedure employing inductively coupled plasma atomic emission spectroscopy has been developed for the precise determination of the composition of Zn1 + xGe1 + xP2 + x alloys after their autoclave digestion. An optimal composition of the acid mixture has been chosen and the conditions preventing element losses in the digestion process have been found. To minimize the error of the developed procedure, the optimal concentration of Zn, Ge, and P in the analytes was found by calculating the results of analysis as atomic ratios Zn : Ge and P : Ge. The accuracy of the developed procedure was confirmed by the standard addition method and the comparison of the results with the results of an independent method. The relative standard deviation of the determination of atomic ratios was 0. 7–2.0%.  相似文献   

17.
A new method has been developed for the determination of trace rare earth elements (REEs) in water samples based on preconcentration with a microcolumn packed with multiwalled carbon nanotubes (MWNTs) prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimum experimental parameters for preconcentration of REEs, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. The studied REEs ions can be quantitatively retained by MWNTs when the pH exceed 3.0, and then eluted completely with 1.0 mol L−1 HNO3. The detection limits of this method for REEs was between 3 and 57 ng L−1, and the relative standard deviations (RSDs) for the determination of REEs at 10 ng mL−1 level were found to be less than 6% when processing 100 mL sample solution. The method was validated using a certified reference material, and has been successfully applied for the determination of trace rare earth elements in lake water and synthetic seawater with satisfactory results.  相似文献   

18.
Abstract

A thin layer partition chromatographic method has been developed for separation of Fe(III), Ni(II), Zn(II), Cu(II), Pb(II) and Mn(II) on thin layers of silica gel-G as an adsorbent. The Rf values were determined using 0.01–0.2 aqueous solution of sodium thioglycolate as a mobile phase. The dependence of Rf values on the migration time, pH and concentration of mobile phase has been studied. The optimum conditions for possible 3-component separation have been determined. Metal ions have been separated, detected, eluted and quantitatively determined by atomic absorption spectroscopy. The present method was applied to the separation and determination of zinc in forensic samples.  相似文献   

19.
For the first time, metal‐exchange in a magnetic metal–organic framework (MOF) via tandem magnetization and post‐synthetic modification has been developed. The new magnetic mixed‐metal metal–organic framework nanocomposite, CoFe2O4/[Cu0.63/Zn0.37‐TMU‐17‐NH2] (CoFe2O4/[Cu/Zn‐MOF]) has been synthesized by immersing the CoFe2O4/Zn‐TMU‐17‐NH2 (CoFe2O4/Zn‐MOF) as a template in DMF solution of Cu (II) salts. CoFe2O4/[Cu/Zn‐MOF] showed to be a highly reactive and easily recoverable magnetic catalyst for the preparation of tetrazole derivatives via one‐pot three‐component reactions of different aldehydes with hydroxyl amine hydrochloride and sodium azide. Our results (Fourier transform‐infrared, inductively coupled plasma‐optical emission spectroscopy, powder X‐ray diffraction, field emission‐scanning electron microscopy, energy‐dispersive X‐ray spectroscopy‐mapping and vibrating‐sample magnetometer) show successful partial metal‐exchange in which the framework integrity remained intact during the metal‐exchange process.  相似文献   

20.
A simple back-extraction method was developed for the separation and preconcentration of trace levels of zinc from different matrices. Ethyl-2-(4-methoxybenzoyl)-3-(4-methoxyphenyl)-3-oxopropanoylcarbamate (EMPC) was used as a new complexing agent for the extraction of zinc(II) from the aqueous sample phase to the methyl isobutyl ketone (MIBK) phase as Zn(EMPC)2 complexes. The Zn(II) can be selectively stripped with 1?mL of 0.5?mol?L?1 HCl from Mn+(EMPC)n complexes [Ag(I), Al(III), Cd(II), Cr(III), Cu(II), Fe(II), Fe(III), Mn(II), Ni(II), Pb(II) and Pd(II)] which dissolved in MIBK phase. Some experimental parameters, which are important for the whole extraction process, including pH, sample volume, shaking time, amount of the EMPC reagent, amount of MIBK, ionic strength, and type of back-extractant were investigated. The recovery for Zn(II) was greater than 95%. The detection limit of the method was found to be 0.2?µg?L ? 1 and the relative standard deviation as 6.4%. The concentrations of Zn(II) in the certified reference materials (LGC6019 river water and NIST-1547 peach leaves) by the presented method were in good agreement with the certified values. The proposed method was succesfully applied to the determination of zinc in some natural waters, rice, hair, soil, and tea samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号