首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
The plastic material known as cyclic olefin copolymer (COC) is a useful substrate material for fabricating microfluidic devices due to its low cost, ease of fabrication, excellent optical properties, and resistance to many solvents. However, the hydrophobicity of native COC limits its use in bioanalytical applications. To increase surface hydrophilicity and reduce protein adsorption, COC surfaces were photografted with poly(ethylene glycol) methacrylate (PEGMA) using a two-step sequential approach: covalently-bound surface initiators were formed in the first step and graft polymerization of PEGMA was then carried out from these sites in the second step. Contact angle measurements were used to monitor and quantify the changes in surface hydrophilicity as a function of grafting conditions. As water droplet contact angles decreased from 88 degrees for native COC to 45 degrees for PEGMA-grafted surfaces, protein adsorption was also reduced by 78% for the PEGMA-modified COC microchannels as determined by a fluorescence assay. This photografting technique should enable the use of COC microdevices in a variety of bioanalytical applications that require minimal nonspecific adsorption of biomolecules.  相似文献   

2.
This review focuses on advances reported from April 2009 to May 2011 in PDMS surface modifications for the application in microfluidic devices. PDMS surface modification techniques presented here include improved plasma and graft polymer coating, dynamic surfactant treatment, hydrosilylation-based surface modification and surface modification with nanomaterials such as carbon nanotubes and metal nanoparticles. Recent efforts to generate topographical and chemical patterns on PDMS are also discussed. The described surface modifications not only increase PDMS wettability, inhibit or reduce non-specific adsorption of hydrophobic species onto the surfaces in the act, but also result in the display of desired functional groups useful for molecular separations, biomolecular detection via immunoassays, cell culture and emulsion formation.  相似文献   

3.
Protein adsorption on PDMS surfaces poses a significant challenge in microfluidic devices that come into contact with biofluids such as blood. Polyurethane (PU) is often used for the construction of medical devices, but despite having several attractive properties for biointerfacing, it has not been widely used in microfluidic devices. In this work we developed two new fabrication processes for making thin, transparent and flexible PU-based microfluidic devices. Methods for the fabrication and bonding of microchannels, the integration of fluidic interconnections and surface modification with hydrophilic polyethylene oxide (PEO) to reduce protein adsorption are detailed. Using these processes, microchannels were produced having high transparency (96% that of glass in visible light), high bond strength (326.4 kPa) and low protein adsorption (80% reduction in fibrinogen adsorption vs. unmodified PDMS), which is critical for prevention of fouling. Our findings indicate that PEO modified PU could serve as an effective alternative to PDMS in blood contacting microfluidic applications.  相似文献   

4.
Surface modification of polymer materials for preparing microfluidic devices including poly(dimethyl siloxane) (PDMS) was investigated with phospholipids polymers such as poly(2-methacryloyloxylethyl phosphorylcholine(MPC)-co-n-butyl methacrylate) (PMB) and poly(MPC-co-2-ethylhexyl methacrylate-co-2-(N,N-dimethylamino)ethyl methacrylate) (PMED). The hydrophilicity of every surface on the polymer materials modified with these MPC polymers increased and the value of zeta-potential became close to zero. The protein adsorption on the polymer materials with and without the surface modification was evaluated using a protein mixture of human plasma fibrinogen and serum albumin. Amount of proteins adsorbed on these polymeric materials showed significant reduction by the surface modification with the MPC polymers compared to the uncoated surfaces ranging from 56 to 90%. Furthermore, we successfully prepared PDMS-based microchannel which was modified by simple coating with the PMB and PMED. The modified microchannel also revealed a significant reduction of adsorption of serum albumin. We conclude that the MPC polymers are useful for reducing unfavorable protein adsorption on microfluidic devices.  相似文献   

5.
We report a simple modification of poly(dimethylsiloxane) (PDMS) surfaces with poly(ethylene glycol) (PEG) through the adsorption of a graft copolymer, poly(l-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) from aqueous solution. In this approach, the PDMS surface was treated with oxygen plasma, followed by immersion into aqueous solution containing PLL-g-PEG copolymers. Due to the hydroxyl/carboxylic groups generated on the PDMS surface after oxygen plasma, the polycationic PLL backbone is attracted to the negatively charged surface and PEG side chains exhibit an extended structure. The PEG/aqueous interface generated in this way revealed a near-perfect resistance to nonspecific protein adsorption as monitored by means of optical waveguide lightmode spectroscopy (OWLS) and fluorescence microscopy.  相似文献   

6.
This paper shows the in situ synthesis of an hexyl acrylate monolith in PDMS microfluidic devices and its subsequent use as stationary phase for electrochromatography on chip. To overcome the ability of PDMS material to absorb organic monomers, surface modification of the enclosed channels was realized by UV-mediated graft polymerization. This grafting procedure is based on the preliminary adsorption of a photoinitiator onto the PDMS surface and polymerization of charged monomers. Next, hexyl acrylate monoliths were cast in situ using photopolymerization process. The chromatographic behavior of the monolithic column was confirmed by the successful separation of derivatized catecholamines in the PDMS device using a 30 mm effective separation length (100 microm x 100 microm section). Efficiencies reached up to 200,000 plates per meter.  相似文献   

7.
报道了一种能够促进细胞黏附的生物活性表面的制备方法.首先通过表面引发原子转移自由基聚合方法在硅表面接枝了聚(N-甲基丙烯酰氧基琥珀酰亚胺)(PNMASI)聚合物刷.随着反应时间的增加,接枝层厚度基本呈线性增长,表明聚合反应具有一定的可控性.蛋白质吸附测试表明PNMASI改性后的表面具有高密度固定生物分子的能力.同时,通...  相似文献   

8.
A new environmentally friendly method is developed for preventing nonspecific biomolecules from adsorption on poly(dimethylsiloxane) (PDMS) surface via in situ covalent modification. o-[(N-Succinimdyl)succiny]-o'-methyl-poly(ethylene glycol) (NSS-mPEG) was covalently grafted onto PDMS microchannel surface that was pretreated by air-plasma and silanized with 3-aminopropyl-triethoxysilanes (APTES). The modification processes were carried out in aqueous solution without any organic solvent. The mPEG side chains displayed extended structure and created a nonionic hydrophilic polymer brushes layer on PDMS surface, which can effectively prevent the adsorption of biomolecules. The developed method had improved reproducibility of separation and stability of electroosmotic flow (EOF), enhanced hydrophilicity of surface and peak resolution, and decreased adsorption of biomolecules. EOF in the modified microchannel was strongly suppressed, compared with those in the native and silanized PDMS microchips. Seven amino acids have been efficiently separated and successfully detected on the coated PDMS microchip coupled with end-channel amperometric detection. Relative standard deviations (RSDs) of their migration time for run-to-run, day-to-day and chip-to-chip, were all below 2.3%. Moreover, the covalent-modified PDMS channels displayed long-term stability for 4 weeks. This novel coating strategy showed promising application in biomolecules separation.  相似文献   

9.
Spatial control of cell growth on surfaces can be achieved by the selective deposition of molecules that influence cell adhesion. The fabrication of such substrates often relies upon photolithography and requires complex surface chemistry to anchor adhesive and inhibitory molecules. The production of simple, cost-effective substrates for cell patterning would benefit numerous areas of bioanalytical research including tissue engineering and biosensor development. Poly(dimethylsiloxane) (PDMS) is routinely used as a biomedical implant material and as a substrate for microfluidic device fabrication; however, the low surface energy and hydrophobic nature of PDMS inhibits its bioactivity. We present a method for the surface modification of PDMS to promote localized cell adhesion and proliferation. Thin metal films are deposited onto PDMS through a physical mask in the presence of a gaseous plasma. This treatment generates topographical and chemical modifications of the polymer surface. Removal of the deposited metal exposes roughened PDMS regions enriched with hydrophilic oxygen-containing species. The morphology and chemical composition of the patterned substrates were assessed by optical and atomic force microscopies as well as X-ray photoelectron spectroscopy. We observed a direct correlation between the surface modification of PDMS and the micropatterned adhesion of fibroblast cells. This simple protocol generates inexpensive, single-component substrates capable of directing cell attachment and growth.  相似文献   

10.
Cell and protein compatibility of parylene-C surfaces   总被引:2,自引:0,他引:2  
Parylene-C, which is traditionally used to coat implantable devices, has emerged as a promising material to generate miniaturized devices due to its unique mechanical properties and inertness. In this paper we compared the surface properties and cell and protein compatibility of parylene-C relative to other commonly used BioMEMS materials. We evaluated the surface hydrophobicity and roughness of parylene-C and compared these results to those of tissue culture-treated polystyrene, poly(dimethylsiloxane) (PDMS), and glass. We also treated parylene-C and PDMS with air plasma, and coated the surfaces with fibronectin to demonstrate that biochemical treatments modify the surface properties of parylene-C. Although plasma treatment caused both parylene-C and PDMS to become hydrophilic, only parylene-C substrates retained their hydrophilic properties over time. Furthermore, parylene-C substrates display a higher degree of nanoscale surface roughness (>20 nm) than the other substrates. We also examined the level of BSA and IgG protein adsorption on various surfaces and found that surface plasma treatment decreased the degree of protein adsorption on both PDMS and parylene-C substrates. After testing the degree of cell adhesion and spreading of two mammalian cell types, NIH-3T3 fibroblasts and AML-12 hepatocytes, we found that the adhesion of both cell types to surface-treated parylene-C variants were comparable to standard tissue culture substrates, such as polystyrene. Overall, these results indicate that parylene-C, along with its surface-treated variants, could potentially be a useful material for fabricating cell-based microdevices.  相似文献   

11.
A surface modification technique was developed in which heparin was covalently immobilized onto electrically conductive polypyrrole (PPY) film through poly(ethylene glycol) methacrylate (PEGMA) graft copolymerization and subsequent cyanuric chloride activation. In vitro plasma protein adsorption and thrombus formation experiments were carried out on the various films. The PEGMA-graft-copolymerized PPY surfaces with immobilized heparin have good bioactivity indicated by low level of protein adsorption, high ratio of albumin to fibrinogen adsorption, and low thrombus formation, making them potentially good candidates for biomedical applications. Since the PPY film retained significant electrical conductivity after surface modification, the effect of electrical stimulation on protein adsorption and thrombus formation was also evaluated. The covalently immobilized heparin on the PPY film was able to retain its bioactivity after 4 days of immersion in PBS. The film after long-term immersion in PBS also retained sufficient electrical conductivity for electrical stimulation still to be effective for reducing protein adsorption.  相似文献   

12.
The uncontrolled accumulation of biological materials on the surface of medical devices through protein adsorption or cell adhesion causes adverse biological reactions in the living host system, leading to complications. In this study, poly(ethylene glycol) (PEG) is successfully grafted onto polyurethane (PU) surfaces by using a new strategy through a simple and efficient transurethanization reaction. The PEG hydroxyl group is deprotonated and then reacted with the PU surface to provide antiadhesive hydrophilic surfaces in a single step. Surface analysis techniques proved the grafting to be efficient and the formation of a hydrophilic polymeric layer at the surface of PU. Biological assays showed that the surface modification induced lower protein adsorption, cell, platelet, and bacterial adhesion than untreated surfaces, showing a potential for biomedical applications.  相似文献   

13.
Polysulfone/poly(ethylene glycol) amphiphilic networks were prepared via in situ photo-induced free radical crosslinking polymerization. First, the hydrophobic polysulfone diacrylate (PSU-DA) oligomer was synthesized by condensation polymerization and subsequent esterification processes. Then, the obtained oligomer was co-crosslinked with the hydrophilic poly(ethylene glycol) diacrylate (PEG-DA) or poly(ethylene glycol) methyl ether acrylate (PEG-MA) at different feed ratios. In the case of PEG-MA, the resulting network possessed dangling pendant hydrophilic chains on the crosslinked surface. The structure and the morphology of the membranes were characterized by attenuated total reflection infrared spectroscopy (ATR-IR) and scanning electron microscopy (SEM). The enhancement of surface hydrophilicity was investigated by water contact angle measurements. The biomolecule adsorption properties of these networks were also studied. The biomolecules easily adsorbed on the surface of the hydrophobic polysulfone networks whereas dangling hydrophilic chains on the surface prevented the adsorption of the biomolecules.  相似文献   

14.
Polyurethanes were modified using monobenzyloxy polyethylene glycol (BPEG) which possesses a bulky hydrophobic benzyloxy group at one end and a hydroxyl group at the other end as a preconstructed BPEG layer, and poly(ethylene glycol) (PEG) and monomethoxyl poly(ethylene glycol) (MPEG) with various chain lengths as fillers. Our objective was to investigate the effect of PEG graft density and conformation on protein adsorption at PEGlated surface. The graft density was estimated by a chemical titration method. The combination of ATR-FTIR, AFM and titration results provide evidences that the graft density can be increased by backfilling PEG or MPEG to a BPEG layer. However, fibrinogen and albumin adsorption significantly increased on all surfaces after PEG or MPEG backfilling. We conclude that the conformation of hydrophobic benzyloxy end groups of the BPEG layer plays a key role. The benzyloxy end groups of preconstructed PEG chains stretch to the surface after PEG backfilling, which possibly accounts for the observed increase in protein adsorption. The BPEG conformation change after backfilling with PEG or MPEG was also suggested by contact angles. Additionally, protein adsorption was slightly influenced by the length of filler, suggesting a change in surface morphology.  相似文献   

15.
Cell surface carbohydrates, usually binding with other biomacromolecules (such as lipids and proteins), are involved in numerous biological functions, including cellular recognition, adhesion, cell growth regulation, and inflammation. Synthetic carbohydrate-based polymers, so-called glycopolymers, are emerging as important well-defined tools for investigating carbohydrate-based biological processes and for simulating various functions of carbohydrates. In this study, a novel two-step sequence for the generation of a glycopolymer layer tethered on a polypropylene microporous membrane is described. First, a UV-induced graft polymerization of 2-aminoethyl methacrylate hydrochloride (AEMA) was carried out on the membrane to generate an amino-functionalized surface, and the effects of polymerization factors (monomer/initiator concentration and UV irradiation time) on the grafting density were studied. Second, sugar moieties were bound with the grafted functional layer to form glycopolymer by the reaction between the amino groups on the membrane surface and carbohydrate lactones. Chemical analysis by Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy combined with surface morphology observation by scanning electron microscopy confirmed the graft polymerization of AEMA and the formation of glycopolymer. The decreases of water contact angle and protein adsorption on the membrane revealed the enhancement of hydrophilicity and protein resistance due to the typical characteristics of the glycopolymer tethered on the surface. These results indicated that the novel sequence reported in this work is a facile process to form glycopolymer-modified surfaces.  相似文献   

16.
The fabrication of micropatterned structures on PDMS is a critical step in soft lithography, microfluidics, and many other PDMS-based applications. To substitute traditional mold-casting methods, we develop a simple method to create micropatterned nanostructures on PDMS in one step. After exposing a flat PDMS surface to a UV pen lamp through a photomask (such as a TEM grid), micropatterned nanostructures can be formed readily on the PDMS surface. We also demonstrate that fabricated PDMS can be used for the microcontact printing of protein immunoglobulin (IgG) on solid surfaces. This method is probably the simplest method of creating micropatterned nanostructures on PDMS reported so far because it does not need casting, surface coating, or chemical reagents. Only a UV pen lamp and a photomask are required, and this method can be performed under ambient conditions without vacuum. We expect that this method will greatly benefit researchers who use PDMS regularly in various applications such as soft lithography and microfluidics.  相似文献   

17.
The widespread interest in micro total analysis systems has resulted in efforts to develop devices in cheaper polymer materials such as polydimethylsiloxane (PDMS) as an alternative to expensive glass and silicon devices. We describe the oxidation of the PDMS surface to form ionizable groups using a discharge from a Tesla coil and subsequent chemical modification to augment electroosmotic flow (EOF) within the microfluidic devices. The flow performance of oxidized, amine-modified and unmodified PDMS materials has been determined and directly compared to conventional glass devices. Exact PDMS replicas of glass substrates were prepared using a novel two step micromolding protocol. Chemical force microscopy has been utilized to monitor and measure the efficacy of surface modification yielding information about the acid/base properties of the modified and unmodified surfaces. Results with different substrate materials correlates well with expected flow modifications as a result of surface modification. Oxidized PDMS devices were found to support faster EOF (twice that of native PDMS) similar to glass while those derivatized with 3-aminopropyl triethoxysilane (APTES) showed slower flow rates compared to native PDMS substrates as a result of masking surface charge. Results demonstrate that the surface of PDMS microdevices can be manipulated to control EOF characteristics using a facile surface derivatization methodology allowing surfaces to be tailored for specific microfluidic applications and characterized with chemical force microscopy.  相似文献   

18.
SU-8 has gained widespread acceptance as a negative photoresist. It is also finding increasing use as a structural material in microanalytical devices. Consequently, methods to tailor the surface properties of SU-8 as well as to micropattern coatings on the surface of SU-8 are needed. The SU-8 photoresist consists of EPON SU-8 resin mixed with the photoacid generator triarylsulfonium hexafluoroantimonate. This photoacid generator can also serve as a photoinitiator generating free radicals when illuminated with UV light. Under the appropriate conditions, sufficient triarylsulfonium hexafluoroantimonate remains within cured SU-8 to act as a source of free radicals and initiate UV-mediated grafting of polymers onto the surface of the SU-8. UV-mediated grafting was used to coat SU-8 surfaces with poly(acrylic acid) and other water-soluble monomers. The SU-8 surface was chemically micropatterned by placing a mask between the UV light and SU-8. The X-Y spatial resolution of micropatterned poly(acrylic acid) on the SU-8 surface was 2 mum. Three applications of these chemically modified SU-8 surfaces were demonstrated. In the first, poly(ethylene glycol) was used to protect the SU-8 from interactions with proteins, yielding a surface resistant to biofouling. In the second demonstration, the SU-8 surface was micropatterned with a cell-resistant layer to guide cellular attachment and growth. In the final application, SU-8 micropallets were encoded with polymer lines. The bar codes were read by either absorbance or fluorescence measurements. Thus, UV-mediated graft polymerization is an efficient and effective method to micropattern coatings onto the surface of SU-8.  相似文献   

19.
李新松 《高分子科学》2010,28(4):547-554
<正>The hydrophilicity of silicone hydrogels used as soft corneal contact lens plays an important role in wearing comfort.In order to enhance hydrophilicity and protein resistance,silicone hydrogel membranes were modified by atmospheric pressure glow discharge plasma(APGDP) induced surface graft polymerization of N-vinyl pyrrolidone(NVP) and poly(oligoethylene glycol methyl ether methacrylate)(PEGMA) in this paper.XPS analysis demonstrated the success of graft polymerization of NVP and PEGMA onto the surface of silicone hydrogel membranes.The hydrophilicity of silicone hydrogels was characterized by the measurement of water contact angle(WCA).The result showed that NVP grafted silicone hydrogel has the WCA of about 68°and PEGMA grafted silicone hydrogel has the lowest WCA of about 62°,while the pristine silicone hydrogel is hydrophobic with the WCA of about 103°.Protein resistance of silicone hydrogels was investigated by the method of bicinchoninic acid assay using bovine serum albumin(BSA) as a model.It's found that the grafted silicone hydrogel has a significant improvement of protein resistance,and PEGMA grafting is more efficient for the reduction of protein adsorption than NVP grafting.The silicone hydrogel membranes grafted with NVP and PEGMA are good candidates of soft corneal contact lenses.  相似文献   

20.
《先进技术聚合物》2018,29(10):2601-2611
Biomaterials and their host organism's quintessential place of interaction are the surfaces of materials, as transportation of liquids within microchannels requires hydrophilic surfaces. Modifying the hydrophobic surface of polydimethylsiloxane (PDMS) into a hydrophilic one which can be used in biomaterials remains a big challenge. Herein, PDMS‐hydroxyethylmethacrylate (HEMA) films were prepared by the condensation of PDMS using isophorone diisocyanate as a cross‐linker, followed by the incorporation of HEMA via radical copolymerization. The as‐prepared PDMS‐HEMA films were thereafter hydrophilized via physical treatment with heptamethyltrisiloxane. The surface properties of the obtained PDMS‐HEMA films were characterized in wettability, morphology, topography, swelling, mechanical properties, and protein adsorption. Compared to pristine PDMS‐HEMA as control, the surface wettability, roughness, and protein adsorption of the hydrophilized PDMS‐HEMA films were significantly improved while the films also exhibited excellent optical properties. However, the improvement of the swelling properties remains insignificant, indicating that the interior morphology was still based on the hydrophobic siloxane PDMS. The long‐term hydrophilicity was considered good as no significant hydrophobic recovery was noticeable in a period of 5 months after treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号