1.
《Analytical letters》2012,45(12):1846-1856
A preconcentration methodology utilizing the cloud point phenomenon is described for the determination of copper by flame atomic absorption spectrometry. The reagent Sulfathiazolylazo resorsin was used as a complexing agent. The preconcentration factor of 25-fold was obtained. The calibration curve is linear in the range of 4–400 µ g L?1 with a limit of detection of 0.64 µ g L?1. The relative standard deviation (n = 5, 12 µ g L?1) was 3.5%. The cloud point is formed in the presence of phenol at room temperature. The method was successfully applied to the determination of copper in water samples and a standard reference material.  相似文献   

2.
A solid phase extraction method based on graphene oxide (GO) modified with magnesium oxide (MgO) nanoparticles was developed for the preconcentration and determination of trace amounts of cadmium, copper and nickel ions. The adsorbed analytes were eluted by 4.0 mL of 0.1 M (EDTA) and injected to flame atomic absorption spectrometer. The factors influencing the complex formation and extraction of these heavy metals were optimized. Studies on potential interference by various anions and cations showed the method to be highly selective. The preconcentration factor was about 11 with relative standard deviation of <4.0 for 8 replication determination. The detection limits for the Cd, Cu, Ni were found to be 0.5, 3.4 and 25 µg L?1, respectively. The method was successfully applied for the determination of cadmium, copper and nickel in tap water, well water, sea water, rice and macaroni samples with spike recoveries ranging 93–105 %.  相似文献   

3.
《Analytical letters》2012,45(15):2508-2521
Porous polyaniline coatings doped with different counter ions were electrodeposited on the surface of stainless steel wires using controlled potentiostatic coulometry. Prior to electropolymerization, the stainless steel wires were chemically etched to improve subsequent immobilization of the polyaniline coatings on the substrate and to increase the effective surface area. Porous polyaniline coatings doped with sulfate, nitrate, and perchlorate counter ions were employed for solid-phase microextraction (SPME) of 2-chlorophenol, 2,4-dichlorophenol, triclosan, and 2,4-dichlorophenoxyacetic acid coupled to high-performance liquid chromatography. The results demonstrated that the perchlorate doped polyaniline coating exhibited the highest extraction efficiency for 2-chlorophenol, 2,4-dichlorophenol, and triclosan at pH 5.0, indicating that the extraction capability was modified by introducing different counter ions into the coatings. As a result, the perchlorate doped polyaniline coated fiber was further used for the optimization of extraction condition s . The method provided linear dynamic ranges over 2 to 4 orders of magnitude. The limits of detection were 0.006 µg · L?1, 0.005 µg · L?1, and 0.040 µg · L?1 for 2-chlorophenol, 2,4-dichlorophenol, and triclosan, respectively. The precision expressed as the relative standard deviation ranged from 2.20% to 5.04% for spiked water at 10 µg · L ?1 (n = 5) and the fiber to fiber reproducibility was between 3.27% and 5.91% (n = 5). The method was successfully applied to the determination of chlorophenolics in real water samples. The recoveries of chlorophenolics in spiked water at 5.0 µg · L?1 were between 99.60% and 108.7% with relative standard deviations between 3.24% and 5.47%.  相似文献   

4.
A fast and effective preconcentration method for extraction of organochlorine pesticides (OCPs) was developed using a homogeneous liquid–liquid extraction based on phase separation phenomenon in a ternary solvent (water/methanol/chloroform) system. The phase separation phenomenon occurred by salt addition. After centrifugation, the extraction solvent was sedimented in the bottom of the conical test tube. The OCPs were transferred into the sedimented phase during the phase separation step. The extracted OCPs were determined using gas chromatography–electron capture detector. Several factors influencing the extraction efficiency were investigated and optimized. Optimal results were obtained at the following conditions: volume of the consolute solvent (methanol), 1.0 mL; volume of the extraction solvent (chloroform), 55 μL; volume of the sample, 5 mL; and concentration of NaCl, 5 % (w/v). Under optimal conditions, the preconcentration factors in the range of 486–1,090, the dynamic linear range of 0.01–100 μg L?1, and the limits of detection of 0.001–0.03 μg L?1 were obtained for the OCPs. Using internal standard, the relative standard deviations for 1 μg L?1 of the OCPs in the water samples were obtained in the range of 4.9–8.6 % (n = 5). Finally, the proposed method was successfully applied for extraction and determination of the OCPs in water and fruit samples.  相似文献   

5.
《Analytical letters》2012,45(5):745-756
A new method was developed using weak anion exchange resin modified with sodium diethyldithiocarbamate (DDTC) for the derivatization and preconcentration of copper(II) in water prior to spectrophotometric determination. Several conditions affecting the extraction efficiency were investigated. Under the optimum conditions, an enrichment factor of 50 was achieved. The reaction mechanism of copper(II) and DDTC on the resin and binding experiment was studied. The detection limit is 0.6 μ g L?1. The relative standard deviations of intra- and inter-day ranging from 2.1 to 3.6% and from 1.3 to 4.0% were obtained, respectively, and the recoveries were in the range of 95.3–99.6%.  相似文献   

6.
A method was developed for the determination of silver ion (Ag) by combining dispersive liquid-liquid microextraction preconcentration with graphite furnace atomic absorption spectrometry. Diethyldithiocarbamate was used as a chelating agent, and carbon tetrachloride and methanol as extraction and dispersive solvent. Factors influencing the extraction efficiency of Ag and its subsequent determination were studied and optimized. The detection limit is 12 ng L?1 (3 s) with an enrichment factor of 132, and the relative standard deviation is 3.5% (n?=?7, at 1.0 ng mL?1). The method was successfully applied to the determination of trace amounts of Ag in water samples.  相似文献   

7.
《Analytical letters》2012,45(11):2285-2295
Abstract

Multi‐walled carbon nanotubes (MWNTs) were used as sorbent for flow injection (FI) on‐line microcolumn preconcentration coupled with flame atomic absorption spectrometry (FAAS) for determination of trace cadmium and copper in environmental and biological samples. Effective preconcentration of trace cadmium and copper was achieved in a pH range of 4.5–6.5 and 5.0–7.5, respectively. The retained cadmium and copper were efficiently eluted with 0.5 mol L?1 HCl for on‐line FAAS determination. The MWNTs packed microcolumn exhibited fairly fast kinetics for the adsorption of cadmium and copper, permitting the use of high sample flow rates up to at least 7.8 mL min?1 for the FI on‐line microcolumn preconcentration system without loss of the retention efficiency. With a preconcentration time of 60 sec at a sample loading flow rate of 4.3 mL min?1, the enhancement factor was 24 for cadmium and 25 for copper at a sample throughput of 45 h?1. The detection limits (3σ) were 0.30 and 0.11 µg L?1 for Cd and Cu, respectively. The precision (RSD) for 11 replicate measurements was 2.1% at the 10‐µg L?1 Cd level and 2.4% at the 10‐µg L?1 Cu level. The developed method was successfully applied to the determination of trace Cd and Cu in a variety of environmental and biological samples.  相似文献   

8.
A solid-phase extraction coupled with dispersive liquid–liquid microextraction (DLLME) method followed by graphite furnace atomic absorption spectrometry (GFAAS) was developed for the extraction, preconcentration, and determination of ultra trace amounts of lead in water samples. Variables affecting the performance of both steps were thoroughly investigated. Under optimized conditions, 100 mL of lead solution were first concentrated using a solid phase sorbent. The extracts were collected in 1.50 mL of THF and 18 μL of carbon tetrachloride was dissolved in the collecting solvent. Then 5.0 mL pure water was injected rapidly into the mixture of THF and carbon tetrachloride for DLLME, followed by GFAAS determination of lead. The analytical figures of merit of method developed were determined. With an enrichment factor of 1,800, a linear calibration of 3–60 ng L?1 and a limit of detection of 1.0 ng L?1 were obtained. The relative standard deviation for seven replicate measurements of 30 ng L?1 of lead was 5.2 %. The relative recoveries of lead in mineral, tap, well, and river water samples at spiking level of 10 and 20 ng L?1 are in the range 94–106 %.  相似文献   

9.
A magnetic solid-phase extraction sorbent consisting of polyaniline-coated magnetite nanoparticles entrapped in alginate beads (PANI/alginate/Fe3O4) was successfully synthesised and applied for the extraction and preconcentration of polycyclic aromatic hydrocarbons (PAHs) in water samples. The magnetite nanoparticles helped to provide an easy and rapid isolation of the sorbent from the sample solution using an external magnet. The alginate beads helped to increase the surface area for polyaniline coating. The polyaniline-coated alginate/magnetite composite helped to increase the extraction efficiency due to the π–π interactions between the polyaniline and the PAHs. Various parameters that affected the extraction efficiencies were optimised including the polymerisation time, the amount of sorbent, sample pH, extraction time, ionic strength, and desorption conditions. Under the optimal conditions, a linear response was achieved in the concentration range of 0.040–50.0 µg L?1, and the limit of detection was 0.010 µg L?1. This simple, convenient, cost-effective, and environmentally friendly method was successfully applied for the extraction and enrichment of PAHs in water samples. The recoveries ranged from 86.0% to 97.8% with a relative standard deviation <10 %.  相似文献   

10.
A new effervescence-assisted dispersive liquid-liquid microextraction, EA-DLLME, technique was developed for preconcentration and flame atomic absorption spectrometric determination of copper in aqueous samples. Effervescence assistance and DES combination for metal ion extraction was used for the first time. In the presented study, six different effervescence powders were examined to achieve maximum extraction efficiency. In addition, 1,5 diphenyl carbazide was used as complexing agent and DES prepared by mixing choline chloride and phenol was used as extraction solvent. The effect of several parameters such as pH, concentration of complexing agent, composition and volume of DES, amount of THF, composition and amount of effervescent agent were examined. Performed experiments showed that optimum pH was 6.0, the best effervesce powder composition was NaH2PO4:Na2CO3 with 2 × 10?3:1 × 10?3 molar ratio and the amount of effervesce powder was 0.4 g. Under optimum conditions enhancement factor, limit of detection and limit of quantification were calculated as 78, 2.9 and 9.7 μg L?1, respectively. In addition, to prove precision of the method intra-day relative standard deviations were calculated for 10 and 50 μg L?1 Cu2+ concentrations and found as 2.1% and 1.3%, respectively. The proposed method showed good linearity within the range of 10.0–100 μg L?1. Finally, proposed method was successfully applied to determination of copper traces in aqueous samples.  相似文献   

11.
A simple, sensitive and reliable method has been developed for separation and preconcentration of chromium (VI) from aqueous samples before determination by electrothermal atomic absorption spectrometry. The method is based on the extraction of the hydrophobic complex of chromium (VI) with ammonium pyrrolidine dithiocarbamate in the coacervates made up of decanoic acid reverse micelles in the water–tetrahydrofuran mixture. Parameters affecting the extraction efficiency of the analyte were studied and optimised. Under the optimum conditions, the linear range, enhancement factor, the limit of detection and limit of quantification were found to be 0.008–0.4 µg L?1, 127, and 1.8 ng L?1 and 6.0 ng L?1, of Cr(VI), respectively. The relative standard deviation at the concentration level of 0.1 µg L?1 Cr(VI) (n = 6) was 4.2%. Total chromium was determined after the oxidation of Cr(III) to Cr(VI) with permanganate in acidic medium. The method was successfully applied to the determination of chromium species in water and human serum samples.  相似文献   

12.
A simple and accurate flow injection analysis system coupled with spectrophotometric detector was developed for preconcentration and determination of europium(III) in aqueous samples. The developed flow system includes a europium preconcentration step in a column packed with Amberlite XAD-4 resin impregnated with nalidixic acid at pH 7.0. The europium complex was desorbed from the resin by 0.1 mol L?1 HCl and mixed with arsenazo-III solution (0.05 % solution in 0.1 mol L?1 HCl) and taken to the flow through cell of spectrophotometer where its absorbance was measured at 661 nm. The optimum preconcentration system, chemical and FIA variables were investigated. The preconcentration factors obtained were 115 and 500, detection limits of 0.43 and 0.1 μg L?1, sample throughputs of 40 and 10 were obtained for preconcentration time of 60 and 300 s respectively. The proposed system showed good precision and accuracy with relative standard deviation of 1.5 %. The method has been applied to the determination of europium(III) in real water samples and certified reference material IAEA-SL-1 (Lake sediment).  相似文献   

13.
A fast and reliable method was developed for the selective separation and preconcentration of Cu2+ ions using homogeneous liquid-liquid extraction using a novel benzo-substituted macrocyclic diamide, 5,6,7,8,9,10-hexahydro-2H-1,13,4,7,10-benzodioatriazacyclo-pentadecine-3,11(4 H,12 H)-dione, as a selective complexing agent. An aqueous solution of Zonyl FSA (FSA) was used as a phase-separation agent at pH 4.5. Electrothermal atomic absorption spectrometry was used for Cu2+ determination after preconcentration. The influences of pH, type and volume of the water-miscible organic solvent, concentration of FSA, concentration of the ligand and the effect of diverse ions were investigated. Factorial design and response surface methods were used for the optimization purposes. Under the optimum experimental conditions, 50 ng of Cu2+ in 5 mL aqueous sample could be extracted quantitatively into 76 µL of the sediment phase. The maximum preconcentration factor was 65. The calibration curve was linear in the concentration range 0.2 to 4.0 µg L?1. The detection limit and relative standard deviation were 4 ng L?1 and 4.6%, respectively. The method was successfully applied to the extraction and determination of Cu2+ in natural water samples.  相似文献   

14.
A new magnetic adsorbent, 3-mercaptopropionic acid coated 3-aminopropyl triethoxysilane modified Fe3O4 nanoparticle, was synthesised and used for the extraction and preconcentration of arsenic ions in aqueous solutions followed by electrothermal atomic absorption spectrometric determination. The adsorbent was characterised by TEM, SEM, XRD and FT-IR techniques and the method used the unique properties of magnetic nanoparticles, namely, high surface area and superparamagnetism which gave it the advantages of high extraction capacity, fast separation and low adsorbent consumption. Different parameters affecting extraction efficiency of the analyte including pH value, sample volume, adsorbent amount, extraction time and desorption conditions were investigated and optimised. Under the optimum conditions, wide linear range of 30–25,000 ng L?1 and low detection limit of 10 ng L?1 were obtained. The interday and intraday precisions (as RSD%) for five replicates determination of 50 and 25,000 ng L?1 of arsenic ions were in the range of 2.3–3.2%. Furthermore, no significant interference was observed in the presence of coexisting ions and high preconcentration factor of 198 was obtained. The adsorption isotherm followed Langmuir model and its kinetic was second-order. The accuracy of the method was validated by analysing certi?ed reference materials for water and rice with satisfactory recoveries. Finally, the proposed method was successfully applied for the determination of ultra-trace amounts of arsenic in rice and water samples.  相似文献   

15.
Cloud point extraction (CPE) has been used for the preconcentration and indirect quantification of cyanide after the formation of a ion-associate complex with 3-amino-7-diethylamino-8,9-benzo-2-phenoxazine chloride (Nile blue, NB+) in the presence of copper (II) ions, and later analysis by flame atomic absorption spectrometry (FAAS) using polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) as extracting surfactant. The chemical variables affecting the separation phase and the viscosity affecting the detection process were optimized. At pH 5.5, preconcentration of only 50 mL of sample in the presence of 0.04 % (w/v) PONPE 7.5 and 5.64 × 10?5 mol L?1 Nile blue permitted the detection of 3.75 μg L?1 cyanide. The enhancement factor was 64.7 for cyanide. The proposed method was successfully applied to the determination of free cyanide in environmental water samples. The method was compared with the pyridine–barbituric acid method and the paired t test was used to determine whether the results obtained by the two methods differ significantly.  相似文献   

16.
《Analytical letters》2012,45(9):1430-1441
A new column loaded with modified silica gel-chitosan is proposed as a preconcentration system for adsorption of trace cadmium (II) and copper (II). The optimization steps were performed under dynamic conditions, involving pH, sample flow rate, eluent selection, concentration, volume, and flow rate. Trace Cd(II) and Cu(II) were quantitatively adsorbed by the modified silica gel-chitosan. The metal ions adsorbed on the separation column were eluted with 0.1 M HNO3 and determined by flame atomic absorption spectrometry. Under the optimum conditions, this method allowed the determination of cadmium and copper with limits of detection (LOD) of 20 ng L?1 and 38 ng L?1, respectively. The relative standard deviation values (RSDs) for 1.0 mg L?1 of cadmium and 1.0 mg L?1 of copper were 2.62% and 2.85%, respectively.  相似文献   

17.
《Analytical letters》2012,45(17):2723-2738
The determination of chlorophenols in wastewater with methyl chloroformate derivatization, solid phase extraction, and gas chromatography–mass spectrometry is reported. In order to employ this combined solid phase derivative extraction method, quantitative extraction was performed by the introduction of 100 mL of sample in 1.0 mol L?1 sodium hydroxide into a column containing 500 mg of packed resin at a flow rate of 1.0 mL/min. The chlorophenols were retained and derivatized quantitatively in the column by the introduction of 0.25 mL of methyl chloroformate. The derivatized analytes were eluted with 5.0 mL of hexane before the effluent was dried under a stream of nitrogen. The dried solution was diluted to a volume of 50 µL with hexane followed by analysis by gas chromatography–mass spectrometry. The preconcentration parameters were optimized and under these conditions: limits of detection from 0.010 to 0.423 µg L?1, a preconcentration factor of 2500, and precision values from 4.8 to 7.7% as the relative standard deviation were obtained. The method was employed for the analysis of water samples and the recoveries of the analytes were between 76 and 103%.  相似文献   

18.
In this study, a simple and efficient method has been developed to analyze pesticides in water samples using ultrasonic-assisted dispersive liquid–liquid microextraction (UA-DLLME) combined with gas chromatography-flame ionization detection (GC-FID). Several parameters, including type and volume of extractant and dispersant, extraction time, and amount of salt on extraction performance, were optimized in detail. A mixture of acetonitrile (1.0 mL, dispersant) and carbon tetrachloride (15 μL, extractant) was used for extraction. Under optimal conditions, enrichment factors were obtained between 315 and 1153. The linearity of the method ranged from 1 to 100 μg L?1 with correlation coefficients ≥0.9990. Limits of detection (S/N = 3) ranged between 0.09 and 0.57 μg L?1, depending on the compounds. Relative standard deviations were <8.0 % (n = 5) for both intra- and inter-day analyses. The proposed method was successfully applied for the preconcentration and determination of pesticides in water samples (river water, tap water, and lake water) with recoveries that varied from 90.5 to 107.7 %.  相似文献   

19.
《Analytical letters》2012,45(14):2290-2301
A novel and robust phenyl-functionalized MSU-1 (Ph-MSU) coated fiber for solid-phase microextraction (SPME) coupled to high performance liquid chromatography (HPLC) was developed for the preconcentration and the determination of 2,4,4′-trichlorobiphenyl (PCB 28), 2,4′,5-trichlorobiphenyl (PCB 31), 2,2′,5,5′-tetrachlorobiphenyl (PCB 52), 2,2′,4,5,5′-pentachlorobiphenyl (PCB 101), 2,3′,4,4′,5-pentachlorobiphenyl (PCB 118), 2,2′,3,4,4′,5′-hexachlorobiphenyl (PCB 138), 2,2′,4,4′,5,5′-hexachlorobiphenyl (PCB 153), and 2,2′,3,4,4′,5,5′-heptachlorobiphenyl (PCB 180) in environmental water samples. Experimental conditions affecting SPME were examined in detail. The Ph-MSU coating provided large porosity and short-range mesostructures necessary for high extraction capacity and rapid mass transfer of PCBs. The Ph-MSU coated fiber exhibited selectivity for PCB 28, PCB 31, PCB 118, and PCB 138 in a limited extraction time. Good linearity for all PCBs was obtained with correlation coefficients from 0.9987 to 0.9994. The recoveries were within 94.3% to 103% for the spiked water with 300 ng · L?1 per PCB. The relative standard deviations (RSDs) ranged from 3.10% to 6.23% and the limits of detection (LODs) were between 8.73 ng · L?1 and 13.8 ng · L?1. The proposed method was applied for the determination of PCBs in real river water and rainwater samples. The median recoveries ranged from 85.6% to 118% with RSDs between 4.23% and 8.78%. The experimental results demonstrated that the Ph-MSU fiber coating could be reused for over 250 times without loss of the extraction efficiency. These results clearly indicate that the Ph-MSU coated fiber was rapid, sensitive, and suitable for the preconcentration and determination of trace PCBs in environmental water samples.  相似文献   

20.
《Analytical letters》2012,45(3):408-423
A solid phase derivative extraction method using acetic anhydride was developed for the determination of chlorophenols and alkylphenols in water and fruit juice by gas chromatography–mass spectrometry (GC–MS). The quantitative extraction was performed by passing 100 mL of sample prepared in 0.1 mol L?1 sodium hydroxide through a column packed with 500 mg of a strong anion-exchange resin at a flow rate of 0.75 mL min?1. The retained phenols were quantitatively derivatized in the column by the introduction of 0.25 mL of acetic anhydride. The derivatized phenols were eluted with 3.0 mL of hexane and the effluent was dried under nitrogen. The final volume was diluted to fifty microliters with hexane and analyzed by GC–MS. Under the optimum conditions, preconcentration factors of 2000, limits of detection between 0.005 and 1.796 µg L?1, and relative standard deviations of 2.1% to 6.7% were obtained. The method was successfully applied to wastewater and fruit juice and the recoveries of phenols were between 76% and 111%.  相似文献   