首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 125 毫秒
1.
A novel design is described for an amperometric biosensor based on NAD(P)-dependent glucose dehydrogenase (GDH) combined with a plasma-polymerized thin film (PPF). The GDH is sandwiched between several nanometer thick acetonitrile PPFs on a sputtered gold electrode (PPF/GDH/PPF/Au). The lower PPF layer plays the role as an interface between enzyme and electrode because it is extremely thin, adheres well to the substrate (electrode), has a flat surface and a highly-crosslinked network structure, and is hydrophilic in nature. The upper PPF layer (overcoating) was directly deposited on immobilized GDH. The optimized amperometric biosensor characteristics covered 2.5-26 mM glucose concentration at +0.6 V of applied potential; the least-squares slope was 320 nA mM(-1) cm(-2) and the correlation coefficient was 0.990. Unlike conventional wet-chemical processes that are incompatible with mass production techniques, this dry-chemistry procedure has great potential for enabling high-throughput production of bioelectronic devices.  相似文献   

2.
An amperometric mediated glucose biosensor has been developed based on a sol–gel derived carbon composite material. Glucose oxidase and the mediator vinylferrocene have been immobilised within the porous, rigid and organically modified silicate network in the composite material. The organic group in the silicate network controls the hydrophobicity of the electrode surface and thus limits the wettability of the electrode surface. Various important fabrication factors controlling the biosensor performance have been investigated systematically. The glucose biosensor can be renewed easily in a reproducible manner by a simple polishing step and it has a long operational lifetime. Applicability of the biosensor has been demonstrated in real samples and the results obtained by this biosensor corroborate well with a classical UV spectrophotometric technique.  相似文献   

3.
We propose an electron transfer-mediated amperometric enzyme biosensor based on plasma-polymerized thin film of dimethylaminomethylferrocene (DMAMF) on a sputtered gold electrode. The DMAMF plasma-polymerized film is deposited directly onto the surface of the electrode under dry conditions. The resulting thin film not only has redox sites but also is extremely thin (approximately 20 nm), adheres well onto the substrate (electrode), has a flat surface and a highly-crosslinked network structure, and is hydrophilic in nature. Glucose oxidase is densely immobilized onto the surface of DMAMF plasma-polymerized film on the gold electrode. From the electrochemical measurement, the biosensor can cover the wide range of glucose concentration (1.3 - 81 mM) at +350 mV of applied potential. The current response of the glucose biosensor was decreased by less than 5% in an aerobic solution as compared to that in an anaerobic solution. These show that the DMAMF plasma-polymerized films play a role as the electron transfer mediators between the reaction center of enzyme and the electrode.  相似文献   

4.
高盐生  王媛  狄俊伟 《应用化学》2010,27(3):363-366
采用溶胶-凝胶技术将金纳米粒子和葡萄糖氧化酶一次性固定于硅溶胶-凝胶的网络结构中,制备了葡萄糖生物电化学传感器并优化了传感器的制备条件。酶电极对葡萄糖具有良好的电化学响应,葡萄糖浓度在0.02~2.0 mmol/L范围内和催化电流呈线性关系,检出限为0.005 mmol/L。酶电极在4 ℃下贮存100 d后对葡萄糖的响应仅下降8%。该酶电极灵敏度高、响应快、稳定性好。  相似文献   

5.
A porous organic-inorganic hybrid sol-gel carbon composite has been developed and used for surface covalent bonding of an enzyme for biosensing applications, illustrated by glucose oxidase (GOD). The composite comprises graphite powder, ferrocene, and an amino- and methyl-silicate backbone. The graphite powder provides the conductivity for the electrode and ferrocene acts as the mediator for signal transduction from the active center of the enzyme to the electron conductive surface. The presence of amine groups in the sol-gel silicate network allows for the covalent bonding sites for the enzyme via the carbodiimide reaction. The hydrophobicity and hydrophilicity properties of the electrode surface are controlled by the amine and methyl groups of the silicate network. Systematic optimization of the composite composition has been carried out and the performance of the glucose biosensor has been investigated. The optimal electrode gives a linear response range of 0.1-27 mM glucose with a sensitivity of 1.30 μA mM−1 and detection limit (S/N = 3) of 26 μM.  相似文献   

6.
We report herein the effect of palladium on the redox electrochemistry of ferrocene monocarboxylic acid encapsulated within an organically modified sol-gel glass network (ORMOSIL). It has been found that amount of palladium and its geometrical distribution significantly alter the redox electrochemistry of FcMCA. The geometrical distribution of palladium has been controlled by two methods: (i) palladium is allowed to link within nanostructured network of the ORMOSIL which was subsequently availed from the reactivity of palladium chloride and trimethoxysilane; (ii) palladium powder is encapsulated together FcMCA thus allowing the presence of palladium within the nanoporous domain. The content of palladium is varied by controlling the reaction dynamics of palladium chloride and trimethoxysilane interaction. For this we initially allowed to trigger hydrolysis, condensation and poly-condensation of trimethoxysilane and dimethyldiethoxysilane in acidic medium and subsequently partially dried ORMOSIL film was allowed to interact with palladium chloride. Even with partially dried ORMOSIL derived from trimethoxysilane and dimethyldiethoxysilane undergoes rapid interaction with palladium chloride and the transparent color of ORMOSIL changed to a black colour due to the formation of palladium silicon linkage. The palladium-silicon linkage has been identified by NMR, UV-VIS and transmission electron spectroscopy. The electrochemistry of FcMCA encapsulated within such an ORMOSIL matrix has been studied. Excellent redox electrochemistry of ferrocene monocarboxylic acid having peak potential separation tending to 0 for a multilayered electrode was investigated. The palladium content has been found to affect the redox electrochemistry of ferrocene as well as electrocatalytic efficiency of new ORMOSIL material. The electroanalysis of NADH is reported. The modified electrode is very sensitive to NADH with lowest detection limit of < 1 microM.  相似文献   

7.
A feasible method to fabricate glucose biosensor was developed by covalent attachment of glucose oxidase (GOx) to a gold nanoparticle monolayer modified Au electrode. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) of ferrocyanide followed and confirmed the assemble process of biosensor, and indicated that the gold nanoparticles in the biosensing interface efficiently improved the electron transfer between analyte and electrode surface. CV performed in the presence of excess glucose and artificial redox mediator, ferrocenemethanol, allowed to quantify the surface concentration of electrically wired enzyme (Gamma(E)(0)) on the basis of kinetic models reported in literature. The Gamma(E)(0) on proposed electrode was high to 4.1 x 10(-12) mol.cm(-2), which was more than four times of that on electrode direct immobilization of enzyme by cystamine without intermediate layer of gold nanoparticles and 2.4 times of a saturated monolayer of GOx on electrode surface. The analytical performance of this biosensor was investigated by amperometry. The sensor provided a linear response to glucose over the concentration range of 2.0 x 10(-5)-5.7 x 10(-3) M with a sensitivity of 8.8 microA.mM(-1).cm(-2) and a detection limit of 8.2 microM. The apparent Michaelis-Menten constant (K(m)(app)) for the sensor was found to be 4.3 mM. In addition, the sensor has good reproducibility, and can remain stable over 30 days.  相似文献   

8.
An amperometric glucose biosensor is developed that is based on immobilization of glucose oxidase (GOD) in a composite film of poly(o-aminophenol) (POAP) and carbon nanotubes (CNT), which are electrochemically co-polymerized at a gold (Au) electrode. Because of the high surface per volume ratio and excellent electrical conductivity of CNT, the biosensor based on an Au/POAP/CNT/GOD electrode has lower detection limit (0.01 mM), larger maximum response current (0.24 mA cm(-2)) and higher sensitivity (11.4 mA M(-1) cm(-2)) than the values of the biosensor based on an Au/POAP/GOD electrode. Additionally, the biosensor shows fast response time, large response current, and good anti-interferent ability for ascorbic acid, uric acid and acetaminophen. Good reproducibility and stability of the biosensor are also observed.  相似文献   

9.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

10.
付萍  袁若  柴雅琴  殷冰  曹淑瑞  陈时洪  李宛洋 《化学学报》2008,66(15):1796-1802
在金电极表面修饰一层L-半胱氨酸,再利用静电吸附作用固定纳米普鲁士蓝(nano-PB),然后利用壳聚糖-纳米金复合膜将葡萄糖氧化酶(GOD)固定于修饰电极表面,制成新型的葡萄糖传感器.通过交流阻抗技术,循环伏安法和计时电流法考察了电极的电化学特性.在优化的实验条件下,该传感器在葡萄糖浓度为3.0×10-6~1.0×10-3 mol/L范围内有线性响应,检测下限为1.6×10-6 mol/L.此外该传感器具有响应快、稳定性好和选择性良好的特点,能有效排除常见干扰物质如抗坏血酸、尿酸等对测定的影响.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏