首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Ion mobility-mass spectrometry   总被引:3,自引:0,他引:3  
This review article compares and contrasts various types of ion mobility-mass spectrometers available today and describes their advantages for application to a wide range of analytes. Ion mobility spectrometry (IMS), when coupled with mass spectrometry, offers value-added data not possible from mass spectra alone. Separation of isomers, isobars, and conformers; reduction of chemical noise; and measurement of ion size are possible with the addition of ion mobility cells to mass spectrometers. In addition, structurally similar ions and ions of the same charge state can be separated into families of ions which appear along a unique mass-mobility correlation line. This review describes the four methods of ion mobility separation currently used with mass spectrometry. They are (1) drift-time ion mobility spectrometry (DTIMS), (2) aspiration ion mobility spectrometry (AIMS), (3) differential-mobility spectrometry (DMS) which is also called field-asymmetric waveform ion mobility spectrometry (FAIMS) and (4) traveling-wave ion mobility spectrometry (TWIMS). DTIMS provides the highest IMS resolving power and is the only IMS method which can directly measure collision cross-sections. AIMS is a low resolution mobility separation method but can monitor ions in a continuous manner. DMS and FAIMS offer continuous-ion monitoring capability as well as orthogonal ion mobility separation in which high-separation selectivity can be achieved. TWIMS is a novel method of IMS with a low resolving power but has good sensitivity and is well intergrated into a commercial mass spectrometer. One hundred and sixty references on ion mobility-mass spectrometry (IMMS) are provided.  相似文献   

2.
一种基于离子迁移谱的气相色谱检测器及其应用   总被引:2,自引:0,他引:2  
Cheng S  Chen C  Wang W  Du Y  Han F  Li L  Zhou Q  Zhang X  Li H 《色谱》2011,29(9):901-907
离子迁移谱作为气相色谱的检测器,兼有色谱的高分离能力和离子迁移谱的高灵敏度,有利于实现复杂混合物的实时在线监测。基于在色谱、离子迁移谱方面的研究基础,本实验室搭建了一套以离子迁移谱为检测器的气相色谱仪,分别对检测器的温度、总电压、尾吹气流速等参数进行了系统优化,并用于碘甲烷、1,2-二氯乙烷、四氯化碳和二溴甲烷4种卤代烃化合物的检测。实验结果表明,参数优化后的离子迁移谱检测器对碘甲烷、1,2-二氯乙烷、四氯化碳和二溴甲烷的检出限可分别达到2、0.02、1和0.1 ng,线性范围有两个数量级。离子迁移谱与气相色谱联用,其二维的分离能力可以为复杂混合物的准确定性提供更多的信息,还可以实现不同化合物的选择性检测。  相似文献   

3.
Ion mobility spectrometry (IMS) is an analytical technique used for fast and sensitive detection of illegal substances in customs and airports, diagnosis of diseases through detection of metabolites in breath, fundamental studies in physics and chemistry, space exploration, and many more applications. Ion mobility spectrometry separates ions in the gas‐phase drifting under an electric field according to their size to charge ratio. Ion mobility spectrometry disadvantages are false positives that delay transportation, compromise patient's health and other negative issues when IMS is used for detection. To prevent false positives, IMS measures the ion mobilities in 2 different conditions, in pure buffer gas or when shift reagents (SRs) are introduced in this gas, providing 2 different characteristic properties of the ion and increasing the chances of right identification. Mobility shifts with the introduction of SRs in the buffer gas are due to clustering of analyte ions with SRs. Effective SRs are polar volatile compounds with free electron pairs with a tendency to form clusters with the analyte ion. Formation of clusters is favored by formation of stable analyte ion‐SR hydrogen bonds, high analytes' proton affinity, and low steric hindrance in the ion charge while stabilization of ion charge by resonance may disfavor it. Inductive effects and the number of adduction sites also affect cluster formation. The prediction of IMS separations of overlapping peaks is important because it simplifies a trial and error procedure. Doping experiments to simplify IMS spectra by changing the ion‐analyte reactions forming the so‐called alternative reactant ions are not considered in this review and techniques other than drift tube IMS are marginally covered.  相似文献   

4.
The ionization pathways and ion mobility were determined for sets of structural isomeric and stereoisomeric non-polar hydrocarbons (saturated and unsaturated cyclic hydrocarbons and aromatic hydrocarbons) using a novel miniature differential mobility spectrometer with atmospheric-pressure photoionization (APPI) to assess how structural and stereochemical differences influence ion formation and ion mobility. The analytical results obtained using the differential mobility spectrometry (DMS) were compared with the reduced mobility values measured using conventional time-of-flight ion mobility spectrometry (IMS) with the same ionization technique.The majority of differences in DMS ion mobility spectra observed among isomeric cyclic hydrocarbons can be explained by the formation of different product ions. Comparable differences in ion formation were also observed using conventional IMS and by investigations using the coupling of ion mobility spectrometry with mass spectrometry (APPI-IMS-MS) and APPI-MS. Using DMS, isomeric aromatic hydrocarbons can in the majority of cases be distinguished by the different behavior of product ions in the strong asymmetric radio frequency (rf) electric field of the drift channel. The different peak position of product ions depending on the electric field amplitude permits the differentiation between most of the investigated isomeric aromatics with a different constitution; this stands in contrast to conventional IMS in which comparable reduced mobility values were detected for the isomeric aromatic compounds.  相似文献   

5.
H. Borsdorf  E.G. Nazarov 《Talanta》2007,71(4):1804-1812
The ion mobilities of halogenated aromatics which are of interest in environmental chemistry and process monitoring were characterized with field-deployable ion mobility spectrometers and differential mobility spectrometers. The dependence of mobility of gas-phase ions formed by atmospheric-pressure photoionization (APPI) on the electric field was determined for a number of structural isomers. The structure of the product ions formed was identified by investigations using the coupling of ion mobility spectrometry with mass spectrometry (APPI-IMS-MS) and APPI-MS. In contrast to conventional time-of-flight ion mobility spectrometry (IMS) with constant linear voltage gradients in drift tubes, differential mobility spectrometry (DMS) employs the field dependence of ion mobility. Depending on the position of substituents, differences in field dependence were established for the isomeric compounds in contrast to conventional IMS in which comparable reduced mobility values were detected for the isomers investigated. These findings permit the differentiation between most of the investigated isomeric aromatics with a different constitution using DMS.  相似文献   

6.
A microfabricated electromechanical system based on radio frequency modulated ion mobility spectrometry (MEMS-RFIMS), also known as differential ion mobility spectrometry (DMS) has been successfully interfaced to a custom-fabricated resistively heated temperature programmable micromachined gas chromatograph. In contrast to a conventional time-of-flight ion mobility spectrometer, the DMS uses the non-linear mobility dependence in strong radio frequency electric fields for ion filtering. Selective and sensitive detection of targeted analytes of interest can be achieved by using different transport gases, radio frequencies, and associated compensation voltages. In addition, the detection of both positive and negative ions, depending on the ionization mechanism favorable to the analytes involved is achieved. When compared to a stand-alone GC with a non spectrometric detector or a stand-alone DMS, GC-DMS as a hyphenated technique offers two competitive advantages; two orthogonal separating methods in a single analytical system and the resolving power of gas chromatography to minimize charge exchange in the ionization chamber of the detector. In this article, a portable, resistively heated temperature programmable silicon machined gas chromatograph with differential mobility detection is introduced. The performance of the instrument is illustrated with examples of difficult industrial applications.  相似文献   

7.
Increasing the dimensionality of an analysis enables more detailed and comprehensive investigations of complex mixtures. One dimensional separation techniques like gas chromatography (GC) and ion mobility spectrometry (IMS) provide limited chemical information about complex mixtures. The combination of GC, ion mobility spectrometry, and time-of-flight mass spectrometry (GC-IM-TOFMS) provides three-dimensional separation of complex mixtures. In this work, a hybrid GC-IM-TOFMS with a secondary electrospray ionization (SESI) source provided four types of analytical information: GC retention time, ion mobility drift time, mass-to-charge ratios, and ion intensity. The use of secondary electrospray ionization enables efficient and soft ionization of gaseous sample vapors at atmospheric pressure. Several complex mixtures, including lavender and peppermint essential oils, were analyzed by GC-SESI-IM-TOFMS. The resulting 3D data from these mixtures, each containing greater than 50 components, were plotted as 3D projections. In particular, post-processed data plotted in three dimensions showed that many mass selected GC peaks were resolved into different ion mobility peaks. This technique shows clear promise for further in-depth analyses of complex chemical and biological mixtures.  相似文献   

8.
In the present work we describe the principles of operation, versatility and applicability of a trapped ion mobility spectrometer (TIMS) analyzer for fast, gas-phase separation of molecular ions based on their size-to-charge ratio. Mobility-based separation using a TIMS device is shown for a series for isobar pairs. In a TIMS device, mobility resolution depends on the bath gas velocity and analysis scan speed, with the particularity that the mobility separation can be easily tuned from low to high resolution (R?>?50) in accordance with the analytical challenge . In contrast to traditional drift tube IMS analyzer, a TIMS device can be easily integrated in a mass spectrometer without a noticeable loss in ion transmission or sensitivity, thus providing a powerful separation platform prior to mass analysis.  相似文献   

9.
10.
Approaches to separation and characterization of ions based on their mobilities in gases date back to the 1960s. Conventional ion mobility spectrometry (IMS) measures the absolute mobility, and field asymmetric waveform IMS (FAIMS) exploits the difference between mobilities at high and low electric fields. However, in all previous IMS and FAIMS experiments ions experienced an essentially free rotation; thus the separation was based on the orientationally averaged cross-sections Omega(avg) between ions and buffer gas molecules. Virtually all large ions are permanent electric dipoles that will be oriented by a sufficiently strong electric field. Under typical FAIMS conditions this will occur for dipole moments >400 D, found for many macroions including most proteins above approximately 30 kDa. Mobilities of aligned dipoles depend on directional cross-sections Omega(dir) (rather than Omega(avg)), which should have a major effect on FAIMS separation parameters. Here we report the FAIMS behavior of electrospray-ionization-generated ions for 10 proteins up to approximately 70 kDa. Those above 29 kDa exhibit a strong increase of mobility at high field, which is consistent with predicted ion dipole alignment. This effect expands the useful FAIMS separation power by an order of magnitude, allowing separation of up to approximately 10(2) distinct protein conformers and potentially revealing information about Omega(dir) and ion dipole moment that is of utility for structural characterization. Possible approaches to extending dipole alignment to smaller ions are discussed.  相似文献   

11.
This review covers applications of ion mobility spectrometry (IMS) hyphenated to mass spectrometry (MS) in the field of synthetic polymers. MS has become an essential technique in polymer science, but increasingly complex samples produced to provide desirable macroscopic properties of high‐performance materials often require separation of species prior to their mass analysis. Similar to liquid chromatography, the IMS dimension introduces shape selectivity but enables separation at a much faster rate (milliseconds vs minutes). As a post‐ionization technique, IMS can be hyphenated to MS to perform a double separation dimension of gas‐phase ions, first as a function on their mobility (determined by their charge state and collision cross section, CCS), then as a function of their m/z ratio. Implemented with a variety of ionization techniques, such coupling permits the spectral complexity to be reduced, to enhance the dynamic range of detection, or to achieve separation of isobaric ions prior to their activation in MS/MS experiments. Coupling IMS to MS also provides valuable information regarding the 3D structure of polymer ions in the gas phase and regarding how to address the question of how charges are distributed within the structure. Moreover, the ability of IMS to separate multiply charged species generated by electrospray ionization yields typical IMS‐MS 2D maps that permit the conformational dynamics of synthetic polymer chains to be described as a function of their length.  相似文献   

12.
The overall objective of this project was to develop an analytical method that utilizes structure selective ion molecule interactions (SSIMI) in ion mobility spectrometry (IMS) to shift the mobility of a targeted analyte through the addition of a gas phase modifier to the buffer gas. IMS is a sensitive, rapid method for the detection of harmful chemicals; however false alarm responses do occur and a reduction in their frequency decrease both the cost and time required for detection. The investigation reported here probed the effects of a series of buffer gas modifiers on the mobilities of chemical warfare agent simulants (CWAs), toxic industrial chemicals (TICs) and a known interference (butyl carbitol) found in fire extinguishing agents. The major finding of this research was that a modifier with a proton affinity similar to, but not greater than, the target analyte produced the greatest changes in mobilities due to the formation of an ion cluster between the neutral modifier and target analyte ion. Mass spectrometry was utilized to confirm the formation of ion-neutral clusters that caused the target ion to shift its mobility. While a number of modifiers were screened, acetonitrile and isobutyronitrile were found to have sufficiently selective SSIMI with the target compound. For example, in the presence of acetonitrile modifier, the protonated response ion of the CWA simulant DMMP, [DMMP]H+, had a mobility shift of 10.8 %, but the mobility was unchanged for the interferent, butyl carbitol. The mobility of the simulant DMMP decreased with the introduction of modifiers, while the mobility of the interference did not change, demonstrating the potential of the SSIMI technique for reducing false alarm rates.  相似文献   

13.
Differential mobility spectrometry (DMS), also commonly referred to as high field asymmetric waveform ion mobility spectrometry (FAIMS) is a rapidly advancing technology for gas-phase ion separation. The interfacing of DMS with mass spectrometry (MS) offers potential advantages over the use of mass spectrometry alone. Such advantages include improvements to mass spectral signal/noise, orthogonal/complementary ion separation to mass spectrometry, enhanced ion and complexation structural analysis, and the potential for rapid analyte quantitation. In this report, we demonstrate the successful use of our nanoESI-DMS-MS system, with a methanol drift gas modifier, for the separation of oligosaccharides. The tendency for ESI to form oligosaccharide aggregate ions and the negative impact this has on nanoESI-DMS-MS oligosaccharide analysis is described. In addition, we demonstrate the importance of sample solvent selection for controlling nanoESI oligosaccharide aggregate ion formation and its effect on glycan ionization and DMS separation. The successful use of a tetrachloroethane/methanol solvent solution to reduce ESI oligosaccharide aggregate ion formation while efficiently forming a dominant MH(+) molecular ion is presented. By reducing aggregate ion formation in favor of a dominant MH(+) ion, DMS selectivity and specificity is improved. In addition to DMS, we would expect the reduction in aggregate ion complexity to be beneficial to the analysis of oligosaccharides for other post-ESI separation techniques such as mass spectrometry and ion mobility. The solvent selected control over MH(+) molecular ion formation, offered by the use of the tetrachloroethane/methanol solvent, also holds promise for enhancing MS/MS structural characterization analysis of glycans.  相似文献   

14.
Clinical and forensic toxicology laboratories are inundated with thousands of samples requiring lengthy chromatographic separations prior to mass spectrometry. Here, we employ differential mobility spectrometry (DMS) interfaced to nano-electrospray ionization-mass spectrometry to provide a rapid ion filtration technique for the separation of ions in gas phase media prior to mass spectral analysis on a DMS-integrated AB SCIEX API 3000 triple-quadrupole mass spectrometer. DMS is efficient at the rapid separation of ions under ambient conditions and provides many advantages when used as an ion filtration technique in tandem with mass spectrometry (MS) and MS/MS. Our studies evaluated DMS-MS/MS as a rapid, quantitative platform for the analysis of drug metabolites isolated from urine samples. In targeted applications, five metabolites of common drugs of abuse were effectively and rapidly separated using isopropanol and ethyl acetate as transport gas modifiers, eliminating the gas chromatography or liquid chromatography-based separations commonly employed in clinical and forensic toxicology laboratories. Calibration curves were prepared for the selected drug metabolites utilizing deuterated internal standards for quantitative purposes. The feasibility of separating and quantitating drug metabolites in a rapid fashion was evaluated by compensation voltage stepping followed by multiple reaction monitoring (MRM) detection. Rapid profiling of clinical and forensic toxicology samples could help to address an urgent need within the scientific community by developing high-throughput analytical methodologies, which could reduce significant case backlogs present within these laboratories.  相似文献   

15.
A tandem ion mobility spectrometer with two sequential differential mobility spectrometry (DMS) drift tubes and with detectors at ambient pressure is described and modes of operation are demonstrated. Separate but coordinated electronic control for each drift tube allows several modes of operation including: all ions passing; compensation voltage (CV) scanning; and ion selection over a narrow CV range. Any of these modes can be applied to each drift tube allowing several combinations of analytical measurements, analogous to tandem mass spectrometry, with ions entered into a gas atmosphere containing reagents between the mobility regions. Ions may be changed by cluster or displacement reactions and characterized in the second DMS analyzer. Proton bound dimers of compounds appearing near 0?V CV in DMS1 were isolated in DMS1, introduced into 1?% isopropanol vapors, and resolved at characteristic CV values in the DMS2. This is achieved with analyzer dimensions little greater than a single DMS instrument.  相似文献   

16.
A program for Monte Carlo simulation of ion transport in non-linear ion mobility spectrometry, also known as field asymmetric ion mobility spectrometry (FAIMS) or differential mobility spectrometry (DMS), has been developed. Simulations are based on elastic collisions between the ions and the gas particles, and take into account the effects of flow dynamics and asymmetric electric fields. Using this program, the separation and diffusion of the ions moving in a planar DMS filtration gap are demonstrated. Ion focusing in a cylindrical filtration gap is also confirmed. A characteristic compensation voltage is found to provide insight for understanding separation in non-linear ion mobility spectrometry. The simulation program is used to study the characteristics of non-linear ion mobility spectrometry, the effect of the carrier gas flow, and the dependence of the compensation voltage and nonlinear mobility coefficient (α) on the applied asymmetric electric field.  相似文献   

17.
The mobilities of a set of common α-amino acids, four tetraalkylammonium ions, 2,4-dimethyl pyridine (2,4-lutidine), 2,6-di-tert-butyl pyridine (DTBP), and valinol were determined using electrospray ionization-ion mobility spectrometry-quadrupole mass spectrometry (ESI-IMS-QMS) while introducing 2-butanol into the buffer gas. The mobilities of the test compounds decreased by varying extents with 2-butanol concentration in the mobility spectrometer. When the concentration of 2-butanol increased from 0.0 to 6.8 mmol m(-3) (2.5×10(2) ppmv), percentage reductions in mobilities were: 13.6% (serine), 12.2% (threonine), 10.4% (methionine), 10.3% (tyrosine), 9.8% (valinol), 9.2% (phenylalanine), 7.8% (tryptophan), 5.6% (2,4-lutidine), 2.2% (DTBP), 1.0% (tetramethylammonium ion, TMA, and tetraethylammonium ion, TEA), 0.0% (tetrapropylammonium ion, TPA), and 0.3% (tetrabutylammonium ion, TBA). These variations in mobility depended on the size and steric hindrance on the charge of the ions, and were due to formation of large ion-2-butanol clusters. This selective variation in mobilities was applied to the resolution of a mixture of compounds with similar reduced mobilities such as serine and valinol, which overlapped in N(2)-only buffer gas in the IMS spectrum. The relative insensitivity of tetraalkylammonium ions and DTBP to the introduction of 2-butanol into the buffer gas was explained by steric hindrance of the four alkyl substituents in tetraalkylammonium ions and the two tert-butyl groups in DTBP, which shielded the positive charge of the ion from the attachment of 2-butanol molecules. Low buffer gas temperatures (100 °C) produced the largest reductions in mobilities by increasing ion-2-butanol interactions and formation of clusters; high temperatures (250 °C) prevented the formation of clusters, and no reduction in ion mobility was obtained with the introduction of 2-butanol into the buffer gas. Low temperatures and high concentrations of 2-butanol produced a series of ion clusters with one to three 2-butanol molecules in compounds without steric hindrance. Clusters of two and three molecules of 2-butanol were also visible. Ligand-saturation on the positive ions with 2-butanol molecules occurred at high concentrations of modifier (6.8 mmol m(-3) at 150°C); when saturated, no further reduction in mobility occurred when 2-butanol was introduced into the buffer gas.  相似文献   

18.
Rapid, hyphenated detection techniques involving a gas chromatograph (GC) coupled to a classical time-of-flight ion mobility (IMS) spectrometer, or more recently, to a micro-machined, miniature differential ion mobility spectrometer (DMS) are quite attractive for in-situ detection of many kinds of volatile organic compounds (VOCs) of concern and notably of natural contaminants appearing in the headspaces of selected foodstuff. This work aims at a rapid detection, identification and quantification of geosmin in the headspace of grape must and of wine. Samples of white and red wines have both been analyzed with a hyphenated GC/DMS and by Solid Phase Micro-Extraction (SPME) coupled to GC/MS taken as a reference. The detection of geosmin at concentrations below the human olfactory threshold of 50 ng/L has been demonstrated.  相似文献   

19.
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two‐dimensional separation. To improve the performance of hyphenated CE‐IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 μL/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5–250 μg/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 μg/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE‐ESI‐IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra‐violet transparent compounds or none fluorescent compounds.  相似文献   

20.
The capability of corona discharge ion mobility spectrometry (CD-IMS) for separation and quantification of sarcosine and L-alanine isomers has been evaluated for the first time. Although these two compounds have the same mass and m/z values in mass spectrometer, ion mobility spectrometry was able to separate and determine them. Variables including carrier gas flow rate, injection and cell temperatures were optimized. The reduced mobilities (K 0) of sarcosine and L-alanine were 1.96 and 1.83, respectively, based on the reduced mobility of nicotinamide. At the optimized conditions the detection limit of sarcosine and L-alanine were 0.7 and 0.9 μg/mL, respectively. The relative standard deviation (RSD) was found to be 6%. Furthermore, a sample injection port of a gas chromatograph was also modified to introduce solvent-free samples into the IMS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏