首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Novel and fast deep eutectic solvent (DES)-based homogeneous liquid–liquid microextraction (HLLME) was applied for the extraction of copper from vegetable samples followed by flame atomic absorption spectrometry (FAAS). 1,5-diphenyl carbazone (DPC) was used as the chelating agent, and a DES was used as the extraction media. The utilized DES was based on benzyl triphenyl phosphonium bromide and ethylene glycol in a 1:8?mole ratio. The phase separation phenomenon was occurred by changing of sample temperature. Several factors influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, an enhancement factor of 64 was obtained. The limit of detection, based on three signal-to-noise ratio, and limit of quantification were found to be 0.13?µg L?1 and 5.0?µg L?1, respectively. The calibration curve was linear within the range of 5.0–250?µg L?1 with r2 > 0.9957. Intra- and inter-day relative standard deviations (%) of 2.1% and 2.6% were obtained at the concentration of 25?µg L?1. The accuracy of the proposed method was evaluated by analyzing a tomato leaves certified reference material and the results were to be in agreement with the certified value. Finally, the feasibility of the method was successfully confirmed by determination of copper in spinach, lettuce, broccoli, potato, carrot and parsley samples.  相似文献   

2.
A new, rapid and sensitive method for the determination of aromatic amines such as o-nitroaniline (NIT), alpha-naphtylamine (NAP), o-chloroaniline (CHL) in environmental water samples was developed with dispersive liquid phase micro-extraction coupled with high performance liquid chromatography. Preliminary experiments indicated that excellent achievements were obtained when chlorobenzene and acetonitrile were employed as the extraction solvent and dispersive solvent, respectively. Some other parameters that would have important effect on the pre-concentration of aromatic amines were investigated in detail. Under the optimal conditions, the method had excellent linear relationship between the peak area and the concentration for NIT, NAP and CHL in the concentration range of 1?~?50?µg?L?1. The limits of detection and precisions of the proposed method were in the range of 0.1?~?0.7?µg?L?1 and 6.3?~?9.7%, respectively. The proposed method has been validated with two real water samples, and the results showed that excellent spiked recoveries in the range of 92.8%?~?111.5% were achieved. All these demonstrated that the proposed method would be very useful and applicable for the determination of such pollutants in the future.  相似文献   

3.
ABSTRACT

The parabens, which are harmful to our bodies, are primarily utilized as preservatives in medicine, personal care products and cosmetics. A novel, more efficient, fast and cheap vortex-assisted liquid phase microextraction method based on deep eutectic solvents (DESs) was developed for the determination of parabens. The microextraction conditions were optimized using these solvents and the analytical parameters of the method were determined under optimal microextraction conditions. After extraction, the chromatographic separation of parabens was undertaken using high-performance liquid chromatography-UV detection. Experimental parameters, such as DES type, DES volume, dilution solvent volume and vortex extraction time were optimized. DES6 [ChCl-Ethylene glycol (1/2)] was the most suitable DES to work in this study. Detection limits for this method of 0.053 µg mL?1 for methylparaben, 0.061 µg mL?1 for ethylparaben, 0.049 µg mL?1 for propylparaben and 0.052 µg mL?1 for butylparaben were obtained. Correlation coefficients (R2) for a concentration range of 0.1–100 µg mL?1 were higher than 0.9992 and relative standard deviation (RSD) values below 2.91% at parabens concentration of 2.5 µg mL?1 were obtained. The results of spike/recovery values of real samples were greater than 84%. When compared with other methods, the main advantages include lower LOD, short extraction time, rapidity, repeatability and simplicity.  相似文献   

4.
Extraction and determination of seven aromatic amines in environmental water samples were performed with solid-phase extraction (SPE) and micellar liquid chromatography (MLC) using experimental design. Extraction of aromatic amines was carried out with a C18 cartridge modified with sodium dodecyl sulphate (SDS). The washing solution and elution solvent for extraction of aromatic amines were aqueous solution containing 5% (v/v) acetonitrile and 5% (v/v) acetone and 3 mL methanol, respectively. The chemometrics approach was applied for the separation optimisation of these compounds using MLC. Different mobile phase compositions were used for modelling based on retention times to obtain the best separation using central composite design. The optimum mobile phase composition for separation and determination of analytes in water samples was 69 mM SDS, 9% v/v 1-propanol and pH = 6.4. Recoveries were between 84.8–93.5% with relative standard deviation (RSD) less than 5.8% (n = 5). Limits of detection and linear range were 1–4.5 and 3.1–125.0 µg/L, respectively. The proposed method was applied to determine the aromatic amines in real samples (river and well waters). Amount of 4-nitroaniline and 3-nitroaniline in river water sample were 2.15 and 1.91 µg/L, respectively.  相似文献   

5.
《Analytical letters》2012,45(14):1995-2005
Using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) ionic liquid as extraction solvent, five estrogens including estrone (E1), 17β-estradiol (E2), estriol (E3), 17α -ethynylestradiol (EE2), and diethylstilbestrol (DES) in water samples were determined by dispersive liquid-liquid microextraction (DLLME) followed by high performance liquid chromatography with a photodiode array detector and a fluorescence detector (HPLC-DAD-FLD). The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of [C6MIM][PF6] dispersed entirely into the sample solution with the help of a disperser solvent (acetone). Parameters including both extraction and disperser solvents and their volumes, extraction and centrifugal time, sample pH, and salt effect were investigated and optimized. Under the optimized conditions, 110–349 fold enrichment factors of analytes were obtained. The calibration curves were linear in the concentration range of 0.2–100 µg L?1 for E2, E3, and EE2 detected with FLD, and 1–100 µg L?1 for E1 and DES detected with DAD. The correlation coefficient of the calibration curve was between 0.9990 and 0.9997. The limits of detection (LOD, S/N = 3) for the five estrogens were in the range of 0.08–0.5 µg L?1. The relative standard deviations (RSD) for six replication experiments at the concentration of 5.0 µg L?1 were ≤5.7%. The proposed method was applied to the analysis of three water samples from different sources (river water, waste water, and sea water). The relative recoveries of spiked water samples are satisfied with 89.3–102.4% and 88.7–105.2% at two different concentration levels of 5.0 and 50.0 µg L?1, respectively.  相似文献   

6.
ABSTRACT

A synthesis of two series of 3-substituted quinazolinones was performed utilizing a green chemistry approach, deep eutectic solvents and microwaves, namely. 2-Methyl-3-substituted-quinazolin-4(3H)-one derivatives were synthesized in a two-step reaction, using choline chloride:urea deep eutectic solvent (DES). 3-Substituted-quinazolin-4(3H)-ones were synthesized in one-pot one-step reaction of anthranilic acid, amines and orthoester in a microwave reactor. For the synthesis of 2-methyl-3-substituted-quinazolin-4(3H)-ones, first conventional synthesis of benzoxazinone, as an intermediate, was performed. Further, benzoxazinone in reaction with corresponding amines, in choline choline:urea deep eutectic solvent, furnished desired compounds. These procedures are based on green principles with the aim of developing synthetic routes for the potential antitumor agents. All compounds were characterized by LC/MS, 1H NMR and 13C NMR spectral techniques. Compound 1 bearing trifluoromethoxyphenyl group showed promising activity against HuT-78 cell line with IC50 of 51.4?±?5.1?µM.  相似文献   

7.
In this study, a simple and efficient method of ligandless-ultrasound-assisted emulsification microextraction (LL-USAEME) followed by inductively coupled plasma-optical emission spectrometry (ICP-OES) has been developed for simultaneous extraction, preconcentration and determination of manganese, cadmium, cobalt and nickel in water samples. In the proposed approach, tetrachloroethylene was selected as extraction solvent. The effect of important experimental factors such as volume of extraction solvent, pH, sonication time, salt concentration, and temperature was investigated by using a fractional factorial design (25?1) to identify important factors and their interactions. In the next step, a Box-Behnken design (BBD) was applied for optimisation of significant factors. The obtained optimal conditions were: 30?µL for extraction solvent, 12 for pH, 5?min for sonication time, and 5% w/v for salt concentration. The limits of detections (LODs) for Cd(II), Co(II), Mn(II) and Ni(II) were 0.20, 0.13, 0.21 and 0.28?µg?L?1, respectively. Relative standard deviations (RSD, C?=?200.0?µg?L?1, n?=?9) were between 3.4–7.5% and the calibration graphs were linear in the range of 0.25 to 1000.0?µg?L?1 for Mn, 0.5–1000.0?µg?L?1 for Co and Ni and 1.0–250.0?µg?L?1 for Cd. The determination coefficients (R 2) of the calibration curves for the analytes were in the range of 0.993 to 0.999. The proposed method was validated by using two certified reference materials, and also the method was applied successfully for the determination of heavy metals in different real water samples.  相似文献   

8.
In the present study, a new method for extraction and preconcentration of amoxicillin and ceftriaxone was used in hospitalised sewage samples, called vortex-assisted liquid-phase microextraction based on the solidification of deep eutectic solvent. Samples were analysed by high-performance liquid chromatography–ultraviolet detection after preparation and extraction. In this method, the new deep eutectic solvent is used as the extraction solvent, which is obtained from the combination of 1-decyl-3-methylimidazolium chloride and n-butanoic acid. The important advantages of this novel extraction solvent include material stability, low density and good freezing point near room temperature. Under the optimum conditions, enrichment factors are in the range of 164–172. Repeatability and reproducibility of the method based on seven replicate measurements of 50.0 µg L?1 of the target analytes in analysed samples were in the range of 2.1–3.5% and 3.8–5.2%, respectively. The limit of detections and linearity are in the range of 0.005–0.10 and 3–600 µg L?1, respectively. The method was successfully applied for the determination of amoxicillin and ceftriaxone in the real sewage samples. The relative recoveries of sewage samples spiked with amoxicillin and ceftriaxone are 91–107%.  相似文献   

9.
An analytical approach for the determination of trace amounts of Cd(II) and Pb(II) has been developed using a home-made tablet-based effervescence-assisted dispersive liquid–liquid microextraction (DLLME) method which was performed in a narrow-bore tube, followed by flame atomic absorption spectrometry. In this method, a mixture of tartaric acid, sodium bicarbonate and NaCl was used to make the disperser tablet. Then, microlitre level of an extraction solvent was added in the tablet, and then, it was released into a narrow-bore tube containing sample solution and a complexing agent. An acid–base reaction immediately occurred between tartaric acid and sodium bicarbonate, and the produced CO2 led to the dispersion of the extraction solvent into the solution as tiny droplets and subsequent extraction of the analytes. The method made possible the determination of Cd(II) and Pb(II) in the ranges of 0.1–10 and 1.0–20 µg L?1, respectively. The limits of detection were obtained 0.43 and 0.05 µg L?1 for Pb(II) and Cd(II), respectively. The limits of quantifications were 0.80 and 0.09 µg L?1 for Pb(II) and Cd(II), respectively. Repeatability of the method, which is expressed as relative standard deviation, was obtained 3.1% (n = 6, C = 2 µg L?1) and 1.3% (n = 6, C = 0.2 µg L?1) for Pb(II) and Cd(II), respectively. The accuracy of the developed method was verified by analysing a certified reference material, namely SPS-WW2 Batch 108. Relative recoveries (84–107%, obtained at three fortification levels) confirmed the usefulness of the method for analysis of the analytes in the environmental water samples and fruit juices. The method was shown to be fast, reliable and environmentally friendly with low organic solvent consumption.  相似文献   

10.
A deep eutectic solvent (DES) of choline chloride and thiourea was synthesised, immobilised on the surface of graphene oxide (GO) nanosheets and reinforced inside the pores of the hollow fibre (DES-GO-HF). Then, solid-phase microextraction flame atomic absorption spectrometry was designed for separation, preconcentration and determination of trace amounts of silver. Various parameters affecting the extraction recovery of the analyte, such as pH, sample volume, type of DES, extraction time, length of the hollow fiber, nature, as well as the volume and concentration of the eluent, were investigated and optimised. Under optimum conditions, the method showed good linearity in the concentration range of 1.0–40.0 µg L?1 with the determination coefficient of (r2) 0.9990 for silver. The method was very sensitive and has limits of detection and quantification (defined as 3Sb/m and 10Sb/m) of 0.2 and 0.7 µg L?1, respectively. The method was successfully applied for the determination of Ag(I) in water, wastewater, ore and hair samples. The accuracy of the method was evaluated through the recovery experiments and the analysis of certified reference materials.  相似文献   

11.
In this work, a solidified floating organic drop microextraction was developed based on a vesicular supramolecular solvent consisting of decanoic acid and quaternary ammonium. The method was used for preconcentration of trace amount of cadmium in different rice samples followed by flow-injection analysis–flame atomic absorption spectrometry. Several parameters affecting the extraction efficiency including pH, concentration of 1-(2-pyridylazo)-2-naphthol as the chelating agent, sample and extraction solvent volume, stirring rate, extraction time, salt effect, and interfering ions were investigated and optimized. Under the optimum conditions, a preconcentration factor of 84 was achieved. LOD and LOQ were found to be 0.09 and 0.31 µg L?1, respectively. The calibration curve was linear within the range of 5.0–700 µg L?1 (r2?>?0.9978). Intra- and inter-day precisions (RSD% n?=?3) were estimated 2.7 and 3.9% at the concentration of 20 µg L?1, respectively. The accuracy of the method was successfully validated by analysis of an SRM-1643f standard reference material. Relative recoveries were achieved within the range of 93–107% elucidating suitability of the method for determination of cadmium in rice samples.  相似文献   

12.
ABSTRACT

In this work, a novel layered sorbent for microextraction by packed sorbent (MEPS) was introduced, which has been prepared by coating graphene oxide/polyamide (GO/PA) nanocomposite (NC) onto cellulose paper through solvent exchange method. Scanning electron microscopy (SEM) was applied to investigate the surface characteristic and morphology of PA and GO/PA NC coated on cellulose paper. The prepared MEPS device was used for extraction of organophosphorous pesticides (OPPs) including chlorpyrifos, fenthion, fenithrothion, ethion, edifenphos and phosalone in environmental aqueous samples followed by detection using gas chromatography-flame ionisation detector (GC-FID). Important parameters affecting the MEPS method including pH of sample solution, extraction draw-discard cycles, sorbent layers, desorption solvent volume and desorption draw-eject number were studied and optimised using central composite design (CCD). Based on the method validation, limits of detection (LODs) were in the range of 0.2–1 µg L?1. The calibration graphs for chlorpyrifos, fenthion and edifenphos are linear in the concentration range of 1 to 500 µg L?1; for ethion and phosalone are linear in the range of 1–1000 µg L?1 and for fenithrothion is linear in the range of 3–1000 µg L?1. The method precision (RSD %) with six replicates determinations was in the range of 3 to 9.4 % and 3.9 to 11.9% for distilled water and spiked river water sample, respectively, at the concentration level of 300 µg L?1 . The developed method was applied successfully to determine OPP compounds in river, dam and tap water samples; accordingly, the relative recoveries (RR%) were obtained in the range of 77.8 to 113.3%.  相似文献   

13.
Screen‐printed electrodes (SPEs) are cheap and disposable. But their application for heavy metal detection is limited due to the low sensitivity and poor selectivity. Here we report the ultrasensitive and simultaneous determination of Zn2+, Cd2+ and Pb2+ on a multiwalled carbon nanotubes and Nafion composite modified SPE with in situ plated bismuth film (MWCNTs/NA/Bi/SPE). The linear curves range from 0.5–100 µg L?1 for Zn2+ and 0.5–80 µg L?1 for Cd2+. Uniquely, the linear curve for Pb2+ ranges from 0.05–100 µg L?1 with a detection limit of 0.01 µg L?1. The practical application was verified in real samples with satisfactory results.  相似文献   

14.
A sensitive and reliable method is described for the determination of total Sb(III,?V) at traces levels by Osteryoung square-wave anodic stripping voltammery (OSWASV). This method is based on the co-deposition of Sb(III,?V) with Bi(III) onto an edge-plane pyrolytic graphite substrate at an accumulation step. OSWASV studies indicated that the co-deposited antimony was oxidised with anodic scans to give an enhanced anodic peak at about 450?mV vs. Ag/AgCl (sat. KCl). The anodic stripping peak current was directly proportional to the total concentration of antimony in the ranges of 0.01–0.10?µg?L?1, 0.10–1.0?µg?L?1 and 1.0–18.0?µg?L?1 with correlation coefficient higher than 0.995 when 2.0?mol?L?1 hydrochloric acid was used. The detection limits calculated as S/N?=?3 was 5.0?ng?L?1 in 2.0?mol?L?1 hydrochloric acid at 180?s deposition time. The relative standard deviation was 5% (n?=?6) at 0.10?µg?L?1 level of antimony. The analytical results demonstrate that the proposed method is applicable to analyses of real water samples.  相似文献   

15.
ABSTRACT

The aim of this work was to develop and validate a method using online solid-phase extraction and ultra-high-performance liquid chromatography coupled to tandem mass spectrometry to determine residues of 22 veterinary drugs including sulfonamides, amphenicols, fluoroquinolones, benzimidazoles, trimethoprim (TMP) and oxytetracycline (OTC) in water from fee-fishing ponds. The optimal analytical conditions were as follows: XBridge C8 SPE column, Acquity UPLC CSH C18 analytical column, sample loading with water:methanol (98:2, v/v), mobile phase of water with 0.1% acetic acid:methanol (with gradient elution) and eluent flow rate of 0.3 mL min?1. Quantification was performed in selected reaction monitoring mode and sulfadimethoxine-d6, ciprofloxacin-d8, florfenicol-d3 and albendazole-d3 were used as internal standards. Water samples collected from 11 fee-fishing ponds showed the presence of residues of FF (0.42–0.74 µg L?1), albendazole (0.05–0.31 µg L?1) and thiabendazole (0.45 µg L?1). Thiamphenicol and TMP were detected at concentrations lower than the limits of quantification of the method (0.1 and 0.001 µg L?1, respectively).  相似文献   

16.
In this paper, a procedure for the determination of 11 aromatic hydrocarbon-type sensitisers and their related compounds from water samples, used in the manufacture of thermal paper, is presented. The compounds were extracted using a solid-phase extraction (SPE) cartridge with an octadecyl (C18) or a phenyl-bonded silica (PH) sorbent and then determined by gas chromatography–mass spectrometry (GC–MS). Factors affecting the performance of the extraction steps were thoroughly evaluated, and their effects on the yield of the sample preparation were discussed. Under optimised experimental conditions, SPE cartridges were conditioned with 10?mL hexane followed subsequently by 10?mL methanol, loaded with water sample at 2?mL?min?1, and eluted with 10?mL hexane at 1.5?mL?min?1. The limits of detection and quantification, calculated for signal-to-noise ratios of 3 and 10, were in the range of 1–5?µg?L–1 and 2.5–10?µg?L–1, respectively. Recovery yields of the present method using river water were in the range of 88%–112% with a C18 sorbent and 86%–116% with a PH sorbent. The repeatability, expressed as a relative standard deviation, was in the range of 2.8%–11% with a C18 sorbent and 0.7%–9.7% with a PH sorbent (n?=?4). Analysis of paper mill effluents revealed the presence of aromatic hydrocarbon-type sensitisers with maximum concentrations of up to 5.2?µg?L?1.  相似文献   

17.
In the present study, room-temperature ionic liquid (RTIL) 1-butyl-3-methylimidazolium hexafluorophosphate was used as extraction solvent in a liquid–liquid microextraction (LLME) procedure followed by liquid chromatography for determining 4-nonylphenol (4-NP) and 4-tert-octylphenol (4-t-OP) in environmental water samples. RTIL-based LLME was a simple, inexpensive, and fast sample preparation method, and its parameters such as extraction time, addition of salt, selection of phase ratio, and pH value were optimized. The optimized method had acceptable limits of detection (LOD) and a precision of 2?µg?L?1 and 8.1% for 4-NP and 0.6?µg?L?1 and 3.7% for 4-t-OP, respectively. The proposed method was successfully applied in river water and effluent from a sewage-treatment plant, and the recoveries spiked at 6?µg?L?1 and 25?µg?L?1 levels were in the range of 82–113%.  相似文献   

18.
《Microchemical Journal》2009,91(2):107-112
A simple and powerful microextraction technique was used for determination of cadmium in water samples using liquid phase microextraction (LPME) followed by graphite furnace atomic absorption spectrometry (GF-AAS). In a preconcentration step, cadmium was extracted from a 2 mL of its aqueous sample in the pH = 6 as cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) cationic complex into a 4 µL drop of nitrobenzene and ammonium tetraphenylborate as counter ion. In the drop, the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [Pd(c) + Pd(i)]. Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time and stirring rate were optimized. Under the optimum conditions, the enrichment factor and recovery were 390 and 78%, respectively. The calibration graph was linear in the range of 0.01–1 µg L 1 with correlation coefficient of 0.9952 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0065 µg L 1 and relative standard deviation (RSD) for eight replicate measurements of 0.1 µg L 1 and 0.4 µg L 1 cadmium was 6.4 and 5.8% respectively. The characteristic concentration was 0.0014 µg L 1 equivalent to a characteristic mass of 5.6 fg. In order to evaluate the accuracy and recovery of the presented method the procedure was applied to the analysis of reference materials and seawater.  相似文献   

19.
《Analytical letters》2012,45(11):1921-1930
This paper describes a simple and sensitive method for the determination of manganese in human urine by graphite furnace atomic absorption spectroscopy (GFAAS), which includes sample preparation by microwave digestion. Matrix modifier combinations, the digestion power, pyrolysis, and atomization temperatures were optimized. A mixture of 5.0 µg Pd(NO3)2 and 3.2 µg Mg(NO3)2 modifier presented the best performance. The optimal temperatures for pyrolysis and atomization were 1500°C and 1950°C, respectively. The GFAAS method was compared to inductively coupled plasma–mass spectrometry (ICP–MS) for the determination of manganese in urine. Analytical figures of merit for GFAAS and ICP–MS were: accuracy (3.46%, 2.19%), precision (3.61%, 5.84%), LOD (0.109 µg · L?1, 0.015 µg · L?1), LOQ (0.327 µg · L?1, 0.045 µg · L?1), and recovery (80–100%, 74–89%). Both methods were employed for the determination of Mn in urine and the results were compared statistically.  相似文献   

20.
A simple, rapid and efficient method, dispersive liquid–liquid microextraction (DLLME) in conjunction with high-performance liquid chromatography (HPLC), has been developed for the determination of three carbamate pesticides (methomyl, carbofuran and carbaryl) in water samples. In this extraction process, a mixture of 35 µL chlorobenzene (extraction solvent) and 1.0 mL acetonitrile (disperser solvent) was rapidly injected into the 5.0 mL aqueous sample containing the analytes. After centrifuging (5 min at 4000 rpm), the fine droplets of chlorobenzene were sedimented in the bottom of the conical test tube. Sedimented phase (20 µL) was injected into the HPLC for analysis. Some important parameters, such as kind and volume of extraction and disperser solvent, extraction time and salt addition were investigated and optimised. Under the optimum extraction condition, the enrichment factors and extraction recoveries ranged from 148% to 189% and 74.2% to 94.4%, respectively. The methods yielded a linear range in the concentration from 1 to 1000 µg L?1 for carbofuran and carbaryl, 5 to 1000 µg L?1 for methomyl, and the limits of detection were 0.5, 0.9 and 0.1 µg L?1, respectively. The relative standard deviations (RSD) for the extraction of 500 µg L?1 carbamate pesticides were in the range of 1.8–4.6% (n = 6). This method could be successfully applied for the determination of carbamate pesticides in tap water, river water and rain water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号