首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Auditory duration discrimination was studied in the European starling (Sturnus vulgaris, n = 3) using a GO/NOGO-procedure. Acoustic signals were presented by the method of constant stimuli. Duration discrimination limens (DDLs) were determined using signal detection theory (threshold criterion d' = 1.8). Weber fractions delta T/T = 0.23 for reference durations of between 800 and 100 ms, respectively. The DDLs for reference durations of 400 and 200 ms did not differ from those of 800 ms. There was no effect of tone frequency. Weber fractions delta T/T for a decrease in duration were independent of the reference durations and the frequencies tested (average delta T/T = 0.19). Duration discrimination is discussed with respect to data from other animals, and to hypotheses on the perception of signal duration.  相似文献   

2.
In the paper the method of approximation of the calibration curve of germanium thermometers for low temperature is analysed using the least-squares method in combination with polynomial series in the form logR=f(T). The advantage of the reverse form logT=f(R) is shown, which enables to minimize the mean square value of relative errorT/T and that is more justifiable that the first form used till now.  相似文献   

3.
通过快速傅里叶变换(FFT)法和复化辛普森法对衍射的数值进行计算,可以看出快速傅里叶变换法是一种积分变换法,而复化辛普森法则是迭代相加的方法.通过计算得出了FFT法的计算速度高于复化辛普森法,计算精度则远低于复化辛普森法;复化辛普森法适合近距离菲涅尔衍射和近场衍射,而FFT法不适合.  相似文献   

4.
Two experiments investigated the temporal integration of trains of tone pulses by normal and by cochlearly impaired listeners. In the first experiment, thresholds were measured for a single 5-ms, 4-kHz tone pulse, and for ten such tone pulses as a function of interpulse interval (delta t). For normal listeners, temporal integration, defined as the threshold difference between one and ten pulses, was about 8 dB for delta t less than 20 ms, and about 5 dB at longer delta t's. For impaired listeners, temporal integration was only about 2-3 dB across the range of delta t's (5-160 ms) studied. A second experiment measured psychometric functions (log d' versus log signal power) for a single pulse and for ten pulses with delta t's of 5 ms and 80 ms. The normal listeners' functions had slopes close to unity in all three conditions, with a few exceptions. The impaired listeners' functions had slopes close to unity for ten pulses with delta t = 5 ms, but had slopes significantly greater than unity for delta t = 80 ms, and for a single pulse. At delta t = 80 ms, the increase in d' relative to the condition with a single tone was similar (a factor of square root of 10) for both impaired and normal listeners, but the threshold difference was smaller for the impaired listeners due to their steeper psychometric functions. For impaired listeners, then, temporal integration at delta t = 80 ms was normal in terms of a change in d' but abnormal when measured as a threshold difference.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
Neutron diffraction measurements have been performed on the cubic compound PrPb(3) in a [001] magnetic field to examine the quadrupolar ordering. Antiferromagnetic components with q = (1/2 +/- delta 1/2 0), (1/2 1/2 +/- delta 0) (delta approximately 1/8) are observed below the transition temperature T(Q) (0.4 K at H = 0) whose amplitudes vary linear with H and vanish at zero field, providing the first evidence for a modulated quadrupolar phase. For H < 1 T, a nonsquare modulated state persists even below 100 mK suggesting quadrupole moments associated with a Tau(3) doublet ground state to be partially quenched by hybridization with conduction electrons.  相似文献   

6.
Subjects discriminated a "standard" pair of tone bursts (T1, T2) from a "comparison" pair (T1 + delta t, T2 + delta f), containing increments in the duration delta t of the first burst and/or the frequency delta f of the second burst. The threshold (d' = 2.0) for delta t was measured as a function of delta f, and the threshold for delta f as a function of delta t. The integration of increments in duration and frequency was studied as a function of the spectral and temporal separation between T1 and T2. A trade-off between the values of delta t and delta f required for d' = 2.0 performance was observed. This integration takes place when delta t, delta f occur simultaneously in the same spectral region, and when they occur separated by up to 120 ms, or by up to a full octave. The efficiency of integration was similar for all conditions of temporal and spectral separation studied, because the discriminability of delta t and of delta f is also nearly uniform across experimental conditions. The results from all experimental conditions are adequately described by a vector summation model derived from TSD. In a subsidiary experiment, subjects categorized pure tones varying in duration and frequency as "high" or "low" in pitch and "long" or "short" in duration. It was found that combined variations in duration and frequency result in essentially independent perceptual processes, although pitch has a small effect upon the perceived duration. It is concluded that spectral-temporal integration is a general ability operating in a variety of stimulus conditions.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
INTRODUCTION: Inhomogeneity of magnetic fields, both B(0) and B(1), has been a major challenge in magnetic resonance imaging (MRI). Field inhomogeneity leads to image artifacts and unreliability of signal intensity (SI) measurements. This work proposes and shows the feasibility of generating equilibrium signal intensity (SI(Eq)) maps that can be utilized either to speed up relaxation-rate measurement or to enhance image quality and relaxation-rate-based weighting in various applications. METHODS: A 1.5-T MRI scanner was used. In canines (n=4), myocardial infarction was induced, and 48 h after the administration of 0.05 mmol kg(-1) Gd(ABE-DTTA), a contrast agent with slow tissue kinetics, in vivo R(1) mapping was carried out using an inversion recovery (IR)-prepared, fast gradient-echo sequence with varying inversion times (TIs). To test the SI(Eq) mapping method without the confounding effects of motion and blood flow, we carried out ex vivo R(1) mapping after the administration of 0.2 mmol kg(-1) Gd(DTPA) using an IR-prepared, fast spin-echo sequence in another group of dogs (n=2). R(1,full) maps and SI(Eq) maps were generated from the data from both sequences by three-parameter nonlinear curve fitting of the SI versus TI dependence. R(1,full) maps served as the reference standard. Raw IR images were then divided by the SI(Eq) maps, yielding corrected SI maps (COSIMs). Additionally, R(1) values were calculated from each single-TI image separately, using the SI(Eq) value and a one-parameter curve-fitting procedure (R(1,single)). Voxelwise correlation analysis was carried out for the COSIMs and the R(1,single) maps, both versus the standard R(1,full) maps. Deviations of R(1,single) from R(1,full) were statistically evaluated. RESULTS: In vivo, COSIM versus R(1,full) showed significantly (P<.05) better correlation [correlation coefficient (CC)=0.95] than SI versus R(1,full) with a TI=700-800 ms, which is 200-300 ms longer than the tau(null) (500 ms) of viable myocardium. With such TIs, SI versus R(1,full) yielded CCs of 0.86-0.88. R(1,single) versus R(1,full) yielded a peak CC of 0.96 at TI=700-900 ms. Mean deviations of R(1,single) from R(1,full) were below 5% for TIs between 500 and 1000 ms. Ex vivo, where tau(null) was 300 ms, the advantage of correction with SI(Eq) was not in the improvement of linear correlation but more in the reduction of scatter. Peak CCs for SI versus R(1,full) and COSIM versus R(1,full) at TI=500 ms were 0.96 for both. The ex vivo CC for R(1,single) versus R(1,full) at TI=500 ms was 0.98. Mean deviations of R(1,single) from R(1,full) were below 5% for TIs between 400 and 700 ms. CONCLUSIONS: Once the corresponding SI(Eq) map is obtained from a control stack, R(1) can be obtained accurately, using only a single IR image and without the need for a stack of TI-varied images. This approach could be applied in various dynamic MRI studies where short measurement time, once the dynamics has started, is of essence. When using this method with IR-prepared T(1)-weighted images, it is essential that the single TI be chosen such that the longitudinal relaxation in all voxels of interest would have passed tau(null). SI(Eq) maps are also useful in eliminating confounders from MR images to allow obtaining SI values that reflect more faithfully the relaxation parameter (R(1)) sought.  相似文献   

8.
The aim of this study was to investigate the utility of the water T(2) values of malignant breast lesions in predicting response after the first and second cycles of neoadjuvant chemotherapy (NAC), both alone and in combination with lesion volumes. Thirty-five patients were scanned before the commencement of chemotherapy and again after the first, second and final treatment cycles. Two methods of obtaining lesion T(2) were used: imaging, where a series of T(2)-weighted images was acquired (T(R)/T(E)=1000/30, 60, 90 and 120 ms), and spectroscopy, where the T(2) value of unsuppressed water signal was determined with a multiecho sequence (T(R)=1.5 s; initial T(E)=35 ms; 64 steps of 2.5 ms; 2 unsuppressed acquisitions per T(E)). Lesion volumes were computed from contrast-enhanced 3D fat-suppressed images. The study found that, using the imaging method of obtaining T(2), the ratio of the product of lesion T(2) and volume after the second cycle of NAC to pretreatment value is a good predictor of ultimate lesion response, defined as a > or =65% reduction in tumor volume after the final treatment cycle, with positive and negative predictive values of 95.5% and 84.6%, respectively.  相似文献   

9.
在0~9T范围内测量了磁场平行于c-轴时Li掺杂熔融织构YBCO样品面内电阻的温度关系.我们用A~H模型拟合实验数据.结果表明,以R/Rn=20%作为高阻区和低阻区的分界线,R~T曲线可分别用R=Rn{I0[CH-p(1-t)q]}-2来描述,其中Rn是正常态的电阻Rn=-5.36 0.145T.p=0.78,1.88 和q=1.5, 3.5分别是高阻区和低阻区的拟合参数.  相似文献   

10.
Cui TW  Zhang J  Ma Y 《光谱学与光谱分析》2010,30(12):3367-3370
基于海洋悬浮颗粒的折射率、粒径分布特征,利用异常衍射近似ADA(anomalous diffraction approximation)和米(Mie)散射方法进行衰减、吸收和散射效率的光谱模拟,分析两种方法计算结果相对偏差Δc,Δa,Δb及其影响因素,探讨利用计算速度占优的ADA方法进行海洋悬浮颗粒光谱模拟的可行性,研究发现:Δc,Δa,Δb受颗粒粒径、折射率实部和虚部的共同影响,且影响方式复杂;ADA方法满足计算精度(相对偏差小于5%)要求的最小颗粒半径Rmin随折射率和波长等的变化而变化。考虑到ADA与Mie的计算偏差受到多种因素的影响,而且海洋悬浮颗粒组分复杂多样,建议在进行海洋悬浮颗粒光谱模拟时,采用经典的Mie方法,而不是计算相对快速的ADA方法。  相似文献   

11.
Proton magnetic resonance spectroscopy has the potential to provide valuable information about alterations in gamma-aminobutyric acid (GABA), glutamate (Glu), and glutamine (Gln) in psychiatric and neurological disorders. In order to use this technique effectively, it is important to establish the accuracy and reproducibility of the methodology. In this study, phantoms with known metabolite concentrations were used to compare the accuracy of 2D J-resolved MRS, single-echo 30 ms PRESS, and GABA-edited MEGA-PRESS for measuring all three aforementioned neurochemicals simultaneously. The phantoms included metabolite concentrations above and below the physiological range and scans were performed at baseline, 1 week, and 1 month time-points. For GABA measurement, MEGA-PRESS proved optimal with a measured-to-target correlation of R(2)=0.999, with J-resolved providing R(2)=0.973 for GABA. All three methods proved effective in measuring Glu with R(2)=0.987 (30 ms PRESS), R(2)=0.996 (J-resolved) and R(2)=0.910 (MEGA-PRESS). J-resolved and MEGA-PRESS yielded good results for Gln measures with respective R(2)=0.855 (J-resolved) and R(2)=0.815 (MEGA-PRESS). The 30 ms PRESS method proved ineffective in measuring GABA and Gln. When measurement stability at in vivo concentration was assessed as a function of varying spectral quality, J-resolved proved the most stable and immune to signal-to-noise and linewidth fluctuation compared to MEGA-PRESS and 30 ms PRESS.  相似文献   

12.
Level discrimination of tones as a function of duration   总被引:1,自引:0,他引:1  
Difference limens for level [delta Ls (dB) = 20 log[p + delta p)/p), where p is the pressure] were measured as a function of duration for tones at 250, 500, and 8000 Hz. Stimulus durations ranged from 2 ms to 2 s, and the stimulus power was held constant. Rise and fall times were 1 ms. The interstimulus interval was 250 ms. At each frequency, three levels were tested: 85, 65, and approximately 40 dB SPL. An adaptive two-alternative forced-choice procedure with feedback was used. For three normal listeners, delta Ls decreased as duration increased, up to at least 2 s, except at 250 Hz. At 250 Hz, delta L stopped decreasing at durations between 0.5 and 1 s. In a double logarithmic plot of delta L versus duration, the rate of decrease is generally well fitted by a sloping line. The average slope is -0.28; it is steeper at high levels than at low levels. Because the average slope is shallower than the -0.5 slope predicted for an optimum detector, it may be that fast adaptation of auditory-nerve activity and/or memory effects interfere with level discrimination of long-duration tones. Finally, the delta Ls at 8 kHz decreased nonmonotonically with increasing level.  相似文献   

13.
Cross-polarization (CP) magic angle spinning (MAS) solid-state 13C NMR spectra of five steroidal sapogenins: tigogenin ((25R)-5alpha-spirostan-3beta-ol), hecogenin (3beta-hydroxy-(25R)-5alpha-spirostan-12-one), diosgenin ((delta5-(25R)-5alpha-spirosten-3beta-ol), sarsasapogenin ((25S)-55beta-spirostan-3beta-ol), and smilagenin ((25R)-5beta-spirostan-3beta-ol) were recorded. The solid-state chemical shifts are almost the same as for solution, which indicate that confirmations of sapogenins are similar in both phases. The doubling of some resonances in the spectra of solid diosgenin shows that there are two molecules in the crystallographic asymmetric unit. The cross-polarization time constants T(CP) and relaxation times in the rotating frame T(1rho)H were obtained from the variable-contact cross-polarization experiments for tigogenin and diosgenin. The values of T(CH) for methyl carbons indicate fast rotation of methyl groups and are close (0.30-0.35 ms), suggesting that the interaction with their intramolecular neighbors is similar. The values of T(1rho)H for carbons of tigogenin are longer than of diosgenin. Very efficient cross-polarization dynamics results in short time required for obtaining a spectrum of sapogenin of remarkably good quality.  相似文献   

14.
裴闯  蒋晓瑜  王加  张鹏炜 《光子学报》2013,42(3):348-353
在传统迭代傅里叶变换算法的基础上,提出了一种计算三维物体相息图的新方法.基于层析法将三维物体的多个分层物面作为衍射再现图像,在一个输入面(相息图)和多个输出面(再现像)之间进行迭代.通过在傅里叶迭代运算中引入距离相位因子,表示物体不同物面的深度,体现了物体的三维特征.实验结果证明了本文算法良好的收敛特性和再现性能.最后,分析了物面数量和间距对全息再现质量的影响,利用液晶空间光调制器采用时分复用的方法还原了三维物体的多个物面.  相似文献   

15.
Experimental measurements of the SOL power decay length (λ(q)) estimated from analysis of fully attached divertor heat load profiles from two tokamaks, JET and ASDEX Upgrade, are presented. Data was measured by means of infrared thermography. An empirical scaling reveals parametric dependency λ(q) in mm = 0.73B(T)(-0.78)q(cyl)(1.2)P(SOL)(0.1)R(geo)(0), where B(T)(T) describes the toroidal magnetic field, q(cyl) the cylindrical safety factor, P(SOL)(MW) the power crossing the separatrix and R(geo)(m) the major radius of the device. A comparison of these measurements to a heuristic particle drift-based model shows satisfactory agreement in both absolute magnitude and scaling. Extrapolation to ITER gives λ(q) ? 1 mm.  相似文献   

16.
张义招  包芸 《物理学报》2015,64(15):154702-154702
Ra数Rayleigh-Bénard热对流的湍流特性研究是当前国际上的一个热门研究课题, DNS模拟计算是研究该课题的重要手段之一. 当计算规模增大而网格数巨大时计算工作难以实现, 高Ra湍流热对流的数值模拟研究面临重大挑战. 本文创建了大规模高效并行计算的三维湍流热对流直接求解方法. 采用FFT变换解耦压力泊松方程, 将其变换成沿z方向上的块三对角方程组, 并利用块三对角方程的MPI与OpenMP联立的大规模高效并行近似解求解方案, 创建了可以高效并行计算的热对流直接求解方法. 通过对该方法并行效率的验证计算, 证明新的直接求解并行计算方法具有很好的并行效率和计算时效. 三维窄方腔热对流的计算结果表明, 本文方法计算的三维热对流特性是合理的. 本文创建的可大规模高效并行计算的三维湍流热对流直接求解方法, 也很可能是关于计算流体力学不可压NS方程大规模高效并行计算在特殊情况中计算技术上的一个突破.  相似文献   

17.
Two new alpha emitters 109Xe and 105Te were identified through the observation of the 109Xe --> 105Te --> 101Sn alpha-decay chain. The 109Xe nuclei were produced in the fusion-evaporation reaction 54Fe(58Ni,3n)109Xe and studied using the Recoil Mass Spectrometer at the Holifield Radioactive Ion Beam Facility. Two transitions at Ealpha = 4062 +/- 7 keV and Ealpha = 3918 +/- 9 keV were interpreted as the l = 2 and l = 0 transitions from the 7/2+ ground state in 109Xe (T1/2 = 13 +/- 2 ms) to the 5/2+ ground state and a 7/2+ excited state, located at 150 +/- 13 keV in 105Te. The observation of the subsequent decay of 105Te marks the discovery of the lightest known alpha-decaying nucleus. The measured transition energy Ealpha = 4703 +/- 5 keV and half-life T1/2 = 620 +/- 70 ns were used to determine the reduced alpha-decay width delta2. The ratio delta105Te(2)/delta213Po(2) of approximately 3 indicates a superallowed character of the alpha emission from 105Te.  相似文献   

18.
In this paper, we formulate the radiative transfer problem as an initial value problem via a pair of nonlinear matrix differential equations (matrix Riccati equations or MREs) which describe the reflection (R) and transmission (T) matrices of the specific intensities in a plane-parallel geometry. One first computes R and T matrices of some small but finite layer thickness (equivalent optical thickness τ∼0.01 and then repetitively applies the doubling method to the reflection and transmission matrices R(τ)and T(τ) until reaching the desired layer thickness. The initial matrices R(τ0)and T(τ0) can be computed quite accurately by either of the following methods: multiple-order, multiple-scattering approximation, iterative method or fourth-order Runge-Kutta techniques. In addition, the reflection coefficient matrix of a semi-infinite medium satisfies an algebraic matrix equation which can be solved repetitively by a matrix method. MREs offer an alternative way of solving plane-parallel radiative transport problems. This method requires only elementary matrix operations (addition, multiplication and inversion). For vector and/or beam-wave radiative transfer problems, large matrices are required to describe the physics adequately, and the MRE method provides a significant reduction in computer memory and computation time.  相似文献   

19.
Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly charged ions, using the TITAN facility at TRIUMF. Compared to singly charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb isotopes have been charge bred in an electron beam ion trap to q=8-12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly charged ions at a radioactive beam facility opens the door to unrivaled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T(1/2)=65 ms). The determination of its atomic mass and an improved Q(EC) value are presented.  相似文献   

20.
The ripening of the tomato fruit was delayed for several days (average 5 days) by a 1-day heat treatment at 42 degrees C. Ethylene production increased during the first 3 h, but, after 6 h inhibition was almost total in tomato fruit incubated at 42 degrees C. However, recovery of ethylene production was rapid if fruits were returned to a temperature of 25 degrees C after heating. In NMR microimaging, three imaging pulse sequences with different repetition and echo times at 42 degrees C were used to obtain the proton density (TR = 6000 ms, TE = 15 ms), the T1 weighted image (TR = 1000 ms, TE = 15 ms) and the T2-weighted image (TR = 6000 ms, TE = 120 ms). After 12 h heating, the water in locular tissues began to show shorter T1 and T2 values. Though the tomatos were returned to 25 degrees C and preserved one more day, the water having a shorter T2 value in locular tissues, did not change. These results show that tomato fruit do not fully recover from heating even after one day, although ethylene production is recovered almost immediately. For this reason, we suggest that some denaturation event inside the tomato, which goes on after the end of heating, is the cause of the delay in tomato ripening.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号