首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
The results of an investigation of the sound insulation provided by wood joist floors between timber frame dwellings are described. The investigation was mainly concerned with impact transmission since available field data showed that the impact performance was, in general, worse than the airborne performance. The effects of changing various aspects of the floor design are discussed and limited guidance is given on the values of some floor parameters. Some tests have been carried out with the resilient layer bridged by nails and with the floor loaded. Suggestions are given for further research which is required to improve the understanding of sound transmission processes in wood joist floors.  相似文献   

2.
The sound insulation of party walls in a four storey block of maisonettes was found to be considerably lower at first floor level than at other floor levels in the frequency range of approximately 600 to 3000 Hz. The rooms at first floor level lie immediately below the party floor which is built of dense concrete cast on woodwool shuttering, plastered beneath; the other floors are timber joist floors and this seems to be the only major difference in construction at different floor levels. Vibration measurements indicated that appreciable flanking transmission of sound was occurring through the ceiling in the frequency range 600 to 3000 Hz and it seems probable that the use of woodwool shuttering has led to a resonance effect producing these high vibration levels.  相似文献   

3.
Lightweight inner leaves contribute more than heavier inner leaves to thermal insulation, but there are reasons for expecting that they may adversely affect the sound insulation of party floors. The most sensitive indicator of the influence of inner leaves is provided by differences, if any, between the performance of centre block and end block floors tested in the same block of flats. Analysis of data from all blocks where floors in both situations were tested shows that, on average, the airborne insulation of end floors is significantly poorer than that of centre floors when the party walls are heavier than the inner leaves. Impact insulation is affected to a smaller extent. The airborne insulation of end floors adjacent to plastered inner leaves of surface mass less than 120 kg/m2 is found to be significantly worse than that of end floors adjacent to heavier inner leaves.When party wall leaves are similar to inner leaves differences are not significant and the two situations may be treated as equivalent. The effect of plasterboard internal partitions is also assessed and found to be beneficial.  相似文献   

4.
The present technique for measuring the airborne sound insulation of walls and floors, involving measurements in 16 one-third octave bands, is tedious and expensive. The method provides more information than is needed for most purposes, and is more suited to research.Several investigators have proposed the measurement of the overall A-weighted sound level difference using a sound level meter, with a broad band source of white or pink noise. Consistent results have been obtained but their relation to accepted rating methods such as STC is rather empirical.The reference curves used for airborne sound insulation, i.e. STC and HPGW are very similar to the A weighting curve, and if the latter were adopted as the reference curve, there would be a firm theoretical basis for measurement with a sound level meter. Measurement of the difference between the linear sound level of a source of white noise, and the A weighted received level, would in practice be a test of the conformity to the A weighting curve of the transmission loss curve of the partition. Adverse deviations would show as a higher received level. Favourable deviations would have little effect.A study of practical walls and floors, taken from National Building Studies Research Paper 33, showed that there was good correlation between the sound level difference calculated as if it had been measured directly with a sound level meter, and a proposed rating method similar to ISO R717, but using the A weighting curve as the reference curve. Ninety-six per cent of results were within ±1 dB.The practical difficulties of achieving a reasonably flat transmitted spectrum, and of correcting for room absorption will reduce this precision, but bearing in mind the practical success of other short tests, the proposed test should provide a rapid test which is adequate for approval purposes.  相似文献   

5.
Sound insulation prediction models in European and International Standards use the vibration reduction index to calculate flanking transmission across junctions of walls and floors. These standards contain empirical relationships between the ratio of mass per unit areas for the walls/floors that form the junction and a frequency-independent vibration reduction index. However, calculations using wave theory show that there is a stronger relationship between the ratio of characteristic moment impedances and the transmission loss from which the vibration reduction index can subsequently be calculated. In addition, the assumption of frequency-independent vibration reduction indices has been shown to be incorrect due to in-plane wave generation at the junction. Therefore numerical experiments with FEM, SFEM and wave theory have been used to develop new regression curves between these variables for the low-, mid- and high-frequency ranges. The junctions considered were L-, T- and X-junctions formed from heavyweight walls and floors. These new relationships have been implemented in the prediction models and they tend to improve the agreement between the measured and predicted airborne and impact sound insulation.  相似文献   

6.
Lightweight building systems in general suffer from poor sound insulation, especially in the low frequency region. Since no reliable mathematical models that can predict the impact sound pressure level exists, the lightweight building design is to a high extent based upon previous experience and upon measurements. A special difficulty is related to experimental measurements since the variation among identical units must not be neglected. A modern volume based lightweight wooden building concept has here been tested by numerous well controlled measurements, in laboratory as well as in more field like conditions. The volume construction technique offers new possibilities and challenges to improve sound insulation in light weight timber construction. The main purpose was to investigate how different constructional solutions in the floor, like plaster board, mineral wool, elastic glue, dividing board, floating floor etc., affect the sound insulation. Many of the tested modifications resulted in only marginally changed impact sound pressure level but parameters that substantially can improve the sound insulation were found in using elastic glue to mount the floor boards, to install extra board layers and to use floating floors.  相似文献   

7.
The vibration reduction index, Kij, is related to the transmission of the vibrational power over a junction between structural elements. Two empirical models are proposed to evaluate Kij, on the basis of statistical evaluations of numerous in-field tests carried out on rigid junctions between floors made by concrete beams and ribbed slab with brick blocks and brickwork walls, a type of junction that is frequently encountered in Southern European and Mediterranean buildings. These models can be applied in order to calculate the sound insulation properties, such as the normalized impact sound pressure level, , and the apparent sound reduction index, R′, of walls and floors in buildings.The first model allows the single number value of the vibration sound reduction index of a junction to be calculated, on the basis of the real properties of the materials that constitute the junction. A new quantity, the “essential” mass per unit area, was introduced to implement the model.The second model provides an estimation of the Kij as a function of frequency, subdivided between BB-junction, as ribbed slab with brick blocks floor-brick wall, and CB-junction, i.e. concrete beam-brick wall.  相似文献   

8.
This paper presents an active triple-panel sound insulation structure with an idealized controllable point force acting on the middle plate. A novel analytical approach based on sound energy transmission rule is proposed to achieve the physical mechanism study. The transfer impedance matrix of the incident and middle plate is calculated using numerical approach. And the rule of sound energy transmission through the triple-panel structure is concluded by indirectly analyzing the radiated sound power of the three plates. Finally the physical mechanism of noise insulation is investigated from the point of view of the change in behaviors of energy transmission in controlled and uncontrolled conditions. Results obtained demonstrate that there exist four different energy transmission paths for four panel mode groups. The energy transmission is independent in each path and they are all of band-pass characteristic. The role of the middle plate and two cavities is very similar to the band-pass filter whose pass-band is different for different mode groups. The essence of active noise insulation lies in the fact that the energy transmission in each path is suppressed in its pass-band after control. This greatly improves sound insulation capability of the triple-panel structure and leads to sound propagation being blocked.  相似文献   

9.
次级源为平面声源的三层有源隔声结构,深入理解有源隔声的物理机理有助于挖掘降噪潜力及实现系统优化设计。首先对三层有源隔声结构建模并求解系统的振动响应。然后,对控制前三层结构中声能量的传输规律进行深入分析。最后,在辐射板声功率最小条件下,通过分析控制前后声能量传输特性的变化阐述了隔声的物理机理。结果表明,声能量在三层结构中传输形成四个等效的传输通道,中间板与两腔的作用类似带通滤波器,不同的传输通道具有相似的带通特性。有源隔声机理在于,通过控制抑制了通带内的能量传输,显著提高了三层结构整体的隔声性能,从而有效阻止了声波的向后传播。   相似文献   

10.
双层弹性支撑板的水下宽带隔声   总被引:1,自引:1,他引:0       下载免费PDF全文
张超  韩玉苑  商德江  李斯慧 《声学学报》2021,46(6):1212-1222
为实现水下宽带隔声,提出了一种由弹性元件支撑两块刚性端板构成的双层弹性支撑板结构。采用弹簧振子振动分析法和声传播理论,建立了平面波入射的水下隔声理论模型,分析了结构参数对隔声量的影响规律,结果表明足够小的弹性元件单位面积弹性系数或足够大的端板单位面积质量都可以连续一致地提高隔声量.仿真分析了双层弹性支撑板的振动位移和声输入阻抗,比较了双层弹性支撑板与连续介质层的隔声特性,结果表明,降低弹性元件质量,有助于在低频段消除半波全透射现象.在同厚度、同质量、同静态压缩率条件下,双层弹性支撑板能更好的降低两侧流体的振动及声耦合,隔声频带更宽,带内一致性更好,隔声量更大.   相似文献   

11.
As sound and vibration fields in dwellings exhibit modal behaviour at frequencies below 200 Hz, a systematic investigation of measurement and prediction uncertainty associated with impact sound transmission at low frequencies must include the effects of: location of the impact, type of floor, edge conditions, floor and room dimensions, room absorption and position of the receiver. Experimentally validated analytical models, described in a companion paper, have been used in an extensive investigation of impact sound transmission through rectangular homogeneous concrete floors and floating floors. The models were used to describe the effect of modal coupling and then to perform parametric and statistical studies aimed to identify the main factors affecting low frequency impact sound transmission.  相似文献   

12.
住宅建筑中相邻房间的侧向传声预测   总被引:1,自引:0,他引:1       下载免费PDF全文
黄险峰  杨宗筱 《声学学报》2018,43(2):253-262
侧向传声作为建筑中声传递的组成部分,对住宅的整体隔声效果具有重要的影响,通过将建筑中相邻房间的各建筑构件划分为若干子系统,应用统计能量分析(Statistical Energy Analysis,SEA)理论,从系统的声功率平衡的角度建立侧向传声的预测模型,在描述各路径的传声规律的同时确定主要传声路径。研究结果表明:当外围护结构为重质结构,且为匀质单一材料构造时,(1)在低频处,全程通过两相邻房间的侧墙或楼板的非通过隔墙的侧向路径成为主要侧向传声路径;(2)在中高频,各侧向路径的声压级差趋于一致,此时的建筑隔声性能取决于通过隔墙的直接路径上的声传递;(3)采用重质隔墙可以缩小侧向传声影响的频率范围。本研究为改善住宅的声环境质量及建筑隔声设计提供了理论依据。   相似文献   

13.
多孔弹性介质三层夹心板的隔声性能研究   总被引:2,自引:0,他引:2       下载免费PDF全文
陈卫松  邱小军 《应用声学》2008,27(2):118-124
应用Biot关于流体饱和多孔弹性介质的声传播理论,采用传递矩阵的分析方法,就复合多孔弹性材料夹心三层板在不同结构情况下的隔声性能进行了理论研究和实验分析,并与同等条件下双层夹心板的隔声性能进行了比较。数值计算和实验结果均表明,与双层夹心板相比,三层夹心板在中高频段隔声性能有明显优势,但低频段隔声性能有一定程度上的下降。研究还表明不同结构的复合三层夹心板在隔声效果上也各有特色。  相似文献   

14.
王亚琴  徐晓美  林萍 《应用声学》2022,41(6):875-883
为探讨薄膜型声学超材料用于汽车前围声学包、提高其中低频隔声能力的可行性,设计一种米字摆臂多质量块薄膜型声学超材料,构建其隔声分析有限元模型 ,分析其隔声特性及影响因素,开展结构优化及其在汽车前围声学包上的应用探索。研究表明,所设计的薄膜型声学超材料单胞在中低频区域具有较宽的隔声频带;增加薄膜上质量块半径或厚度会使传声损失曲线整体向低频区域移动,且质量块半径的增加还会拓宽高频区域的隔声频带;增加薄膜厚度或预应力会使传声损失曲线整体向高频区域移动;优化后的薄膜型声学超材料与钢板组合应用于汽车前围板,可明显提高其中低频隔声能力。  相似文献   

15.
高伟夫  马蕙 《应用声学》2021,40(5):698-704
为提升其隔声性能,通过有限元法数值分析,比较了不同位置墙板的连接方式对房间隔声性能的影响。结果表明:(1)侧墙墙板柔性连接处理对侧向传声的抑制作用显著,当侧墙墙板采用柔性连接后,房间的隔声量在低频段平均可以提升3 dB左右;(2)公共隔墙墙板的柔性连接对房间低频段隔声量提升不明显,甚至在160 Hz、400 Hz、500 Hz等频率下隔声量有所降低。最后,基于模拟分析结果对装配式墙体连接方式提出了改进策略。  相似文献   

16.
This paper is concerned with the analysis of the dependence of low frequency impact sound transmission through floating floor systems on in situ matched resonances. The evidence for the floating floor matched resonances has been found previously considering laboratory and numerical tests for one concrete slab and floating floor with varying resilient layers. In the present paper, considering laboratory and field tests for concrete slabs and floating floors with different plan configurations, this evidence is strengthened as differences between laboratory and field measurements of the impact sound level were negligible for the bare concrete slab but not with the floating floor installed. These results were also confirmed numerically. The analysis indicates that the dependence of low frequency impact sound transmission through floating floor systems on in situ matched resonances should be considered in addition to the conventional single degree of freedom models in order to improve accuracy.  相似文献   

17.
Sound transmission between adjoining rooms is often influenced by a flanking sound passing through open windows placed in the exterior wall of the two rooms. It is important to predict such flanking sound propagation when considering the sound insulation between the adjoining rooms. In this paper, a chart for estimating the distance attenuation of the flanking sound, which is obtained from analysis using the boundary integral equation method, is first provided. Next, 1:10 scale model experiments are carried out. The experimental results are in good agreement with the chart, the effectiveness of the chart thus being verified.  相似文献   

18.
In the two previous parts of this group of papers, the results of measurements of the sound transmission properties of each of the two components of a domestic roofing system were presented and discussed. In this third and final part, the effect on the transmission properties of combining the roof and ceiling components will be investigated and discussed. Comments will also be made on the contribution by the roofing system to the sound insulation provided by the whole building external envelope against the principal types of external noise.  相似文献   

19.
Flanking transmission has significant effects on the overall sound insulation of two adjacent rooms within a residence building. This study investigates the mechanism of the sound flanking transmission by dividing it into several subsystems with the statistical energy analysis method. The sound energy equations of these subsystems are obtained first, and then,the sound transmissions on each flanking path are predicted and the dominant sound transmission path is determined by solving these equations and calculating the total loss factors of the subsystems and coupling loss factors between subsystems. With respect to a masonry building with heavy-weight homogeneous structure, the results show that:(1) the flanking transmission paths instead of the separating wall may become the dominant ones at low frequencies;(2) all sound transmissions on the flanking paths tend to be consistent at medium and high frequencies, so the sound insulation between two adjacent rooms depends on the direct path of the separating wall;(3) heavy-weight separating walls can be used to reduce the frequency range of the flanking transmission.  相似文献   

20.
对混响声场中的弹性平板有源隔声系统进行优化。根据激励频率范围确定受控模态阶次,在模态空间中建立系统降阶方程,基于极点配置方法,采用分布式系统增加受控模态的阻尼,降低低频共振声传输。同时设计模态滤波器,为控制器提供所需的状态信息。为提高控制效能,本文对传感器和作动器布放位置进行优化,尝试不同极点配置方案,并对耦合控制与独立模态控制方法的隔声效果进行比较。仿真结果显示,极点配置法有源隔声可以有效降低共振声传输,优化布放和独立模态控制方式下,控制力明显降低。优化后的有源隔声系统效能有所提升。   相似文献   