首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 202 毫秒
1.
In order to evaluate the reliability and applicability of the Empirical Orthogonal Functions(EOFs)in the acoustic inversion of sound speed profile(SSP)and reduce EOF's dependence on the sample data,a methodology is proposed for the achievement of the basis functions for SSP's expansion.By analyzing the oceanographic dynamics which is the main cause of the SSP's variation,the basis functions are obtained naming the Hydrodynamic Normal Modes(HNMs).The HNM basis functions are almost the same as those derived from the EOF method,while HNMs has less dependence on the amount of the sample data.HNMs method has a physically meaningful interpretation,and it could give out the physical parameters which determine the basis functions for the expansion of SSP,and this makes it possible to analyze and evaluate the trustiness and applicability of EOFs.  相似文献   

2.
A multi-conjugate adaptive optics (MCAO) can offer a possibility of widening field of view (FOV) characterized by the isoplanatic angle, and the choose of conjugate height becomes a basic problem for MCAO, which influences the size of iosplanatic angle. Considering the application of lidar, the isoplanatic angle's expressions of two deformable mirrors (DMs) MCAO for uplink and downlink are deduced. The effects of conjugate heights for dual-conjugate AO are thoughtfully discussed, and the isoplanatic angles are further analyzed. The results show that the isopanatic angle varies with the conjugate height and reaches the maximum as the conjugate height is at the optimal altitude. Moreover, the optimal conjugate height changes with the propagation distance.  相似文献   

3.
Fourier transform infrared spectroscopy (FTIR) was employed to study the human epidermis larynx carcinoma cell lines (Hep-2) which were irradiated by different doses of X-ray.The results show that (1) the irradiation of X-ray damages the structure of the CH3 groups of the thymine in DNA,which restrains the reproduction of Hep-2 cells effectively,(2) the 8 Gy dose of X-ray irradiation changes the framework and the relative contents of some proteins,lipids and the nucleic acid molecules intercellular in the greatest degree,and (3) the 8 Gy dose of X-ray irradiation is the best irradiation dose for lowering the degree of the cancerization of Hep-2 cells according to the criteria for the degree of the cancerization reported recently.Meanwhile,the apoptosis of these cells were detected by using flow cytometry (FCM) primarily.It shows that the apoptotic ratio of the Hep-2 cells depends on the irradiation dose to some extent,but is not linearly.And the apoptotic ratio of the 12 Gy dose group is the maximum (20.36%),but the apoptotic ratios of the 2 to 8 Gy dose groups change little.  相似文献   

4.
To study the new RF control methods, a mathematic model of the RF system for the normal conducting linac is built and implemented with the software of Matlab. The model contains some typical units of the RF system, such as the klystron, the SLED and the traveling wave accelerating tube. Finally, the model is used to study the working point of the SLED and the adaptive feed forward algorithm for the RF control system. Simulation shows that the model works well as expected.  相似文献   

5.
In this letter, we propose a voltage-controlled optical filter based on electrowetting. The device is made of a transparent cubic cell filled with two immiscible liquids having three indium tin oxide electrodes fabricated on the bottom substrate of the cell. A conductive droplet carrying a color filter is placed on the ITO electrode and the surrounding liquid is density-matched silicone oil. Under zero bias, the droplet is placed in the middle of the substrate and white light passes through the filter and we can see red light on the screen. When a voltage is applied to the device, the filter moves with the liquid based on electrowetting effect, we can see the white light on the screen. Due to the movement of the liquid, our device functions as an optical switcher. The switch time of the device is ~70 ms. The proposed device has a wide application in optical communication, electronic display, and optical switch.  相似文献   

6.
Large grain niobium has the potential of simplifying the production sequence and consequently reducing the cost of the superconducting RF cavities for ILC.To investigate the feasibility of fabrication and the possibility to achieve high gradient by large grain cavities,two 1.3 GHz cavities were made of China large grain niobium and a series of vertical tests were carried out following several different surfaces treatment procedures.Two cavities have both reached the high gradient of more than 43 MV/m repeatedly and the maximum accelerating field of 47.9 MV/m has been achieved by China large grain niobium.This paper introduces the features of the fabrication and surface treatments on the large grain cavities and presents the preliminary results of the research.  相似文献   

7.
Influence of purity of HfO2 on reflectance of ultraviolet multilayer   总被引:1,自引:0,他引:1  
The impurities in two kinds of HfO2 materials and in their corresponding single layer thin films were determined through glow discharge mass spectrum technology and secondary ion mass spectrometry(SIMS) equipment respectively.It was found that ZrO2 was the main impurity in the two kinds of HfO2 either in the original HfO2 materials or in the electron beam deposited films.In addition,the difference of Zr content in the two kinds of HfO2 single laver films was much laxger than that of the other impurities such as Ti and Fe.which showed that it was just ZrO2 that made the difference between the optical performance of the film products including the two kinds of HfO2.With these two kinds of HfO2 and the same kind of SiO2.we deposited HfO2/SiO2 multilayer reflective coatings at the wavelength of 266 nm.Experimental results showed that the reflectances of these two mirrors were about 99.85% and 99.15% respectively,which agreed well with the designed results what were based on the optical constants obtained from the corresponding single layer thin films.  相似文献   

8.
When deriving the Fourier diffraction theorem based on the first-order Born approximation,the difference between wave number of the scattering object and that of the surrounding medium is ignored,causing substantial errors in sound scattering prediction.This paper modifies the Born approximation by taking into account the amplitude and phase changes between the scattering object and the water due to the wave number difference.By changing the radius and center position of the sampling circle in the Fourier domain,accuracy of the predicted sound scattering is improved.With the modified Born approximation,the computed far-field directional pattern of the scattered sound from a circular cylinder is in good agreement with the rigorous solution.Numerical calculations for several objects with different shapes are used to show applicability and effectiveness of the proposed method.  相似文献   

9.
Design and operation of a practical, accurate alignment diagnostic system is important for the grating tiling technology, which is supposed to be applied in a chirped-pulse amplification system to increase the output power. A diagnostic method is proposed and demonstrated for grating tiling. Provided that the wavelength and incident angle of the diagnostic beam are properly set, the far-field of the main laser beam and that of the diagnostic beam can vary in the same way with the tiling errors between the sub-aperture gratings. Therefore, rotational and translational errors can be controlled and compensated according to the far-field of the diagnostic beam. The real-time monitoring and alignment can be achieved without disturbing the main beam.  相似文献   

10.
The beam dynamic code PARMELA was used to simulate the transportation process of accelerating electrons in S-band SW linacs with different energies of 2.5, 6 and 20 MeV. The results indicated that in the ideal condition, the percentage of electron beam loss was 50% in accelerator tubes. Also we calculated the spectrum, the location and angular distribution of the lost electrons. Calculation performed by Monte Carlo code MCNP demonstrated that the radiation distribution of lost electrons was nearly uniform along the tube axis, the angular distributions of the radiation dose rates of the three tubes were similar, and the highest leaking dose was at the angle of 160° with respect to the axis. The lower the energy of the accelerator, the higher the radiation relative leakage. For the 2.5 MeV accelerator, the maximum dose rate reached 5% of the main dose and the one on the head of the electron gun was 1%, both of which did not meet the eligible protection requirement for accelerators. We adopted different shielding designs for different accelerators. The simulated result showed that the shielded radiation leaking dose rates fulfilled the requirement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号