首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 694 毫秒
1.
ObjectiveIn this study, we sought to demonstrate the blood suppression performance, image quality and morphological measurements for compressed sensing (CS) based simultaneous 3D black- and gray-blood imaging sequence (CS-siBLAG) in carotid vessel wall MR imaging.Materials and methodsSeven healthy volunteers and five patients were recruited. Healthy subjects underwent five CS-siBLAG scans with 1, 2, 3, 4 and 5-fold accelerations. Signal-to-tissue ratio (STR) and contrast-to-tissue ratio (CTR) were computed as the measures of flowing signal suppression performance and the image quality for black-blood imaging of the technique. Vessel lumen area (LA) and wall area (WA) were compared between fully sampled acquisition and each accelerated acquisition. Patients underwent three CS-siBLAG scans with 1, 3 and 5-fold accelerations as well as a 3D time of flight (3D TOF) scan. Two radiologists reviewed the under-sampled black- and gray-blood image quality.ResultsSTR and CTR values obtained with 2 to 5-fold accelerations were not significantly different from those with full acquisition. LA and WA measured at 2 ×, 3 ×, 4 × and 5 × were all highly correlated to the corresponding values at 1 ×. For patients imaging, two radiologists both found that the dual-contrast images at 3 × acceleration exhibited comparable image quality to that of the fully sampled acquisition, and that the images at 5 × exhibited slightly blurred vessel wall and outer vessel wall boundaries.ConclusionBy combining the CS under-sampling pattern and reconstruction, pseudo-centric phase encoding order and dual blood contrast sequences, this technique provides spatially registered black- and gray-blood images and excellent visualization for vessel wall imaging and gray-blood imaging in a short scan time.  相似文献   

2.
Magnetic resonance imaging and magnetic resonance angiography (MRI/MRA) are widely used for evaluating the moyamoya disease (MMD). This study compared the diagnostic accuracy of 7 Tesla (T) and 3 T MRI/MRA in MMD. In this case control study, 12 patients [median age: 34 years; range (10–66 years)] with MMD and 12 healthy controls [median age: 25 years; range (22–59 years)] underwent both 7 T and 3 T MRI/MRA. To evaluate the accuracy of MRI/MRA in MMD, five criteria were compared between imaging systems of 7 T and 3 T: Suzuki grading system, internal carotid artery (ICA) diameter, ivy sign, flow void of the basal ganglia on T2-weighted images, and high signal intensity areas of the basal ganglia on time-of-flight (TOF) source images. No difference was observed between 7 T and 3 T MRI/MRA in Suzuki stage, ICA diameter, and ivy sign score; while, 7 T MRI/MRA showed a higher detection rate in the flow void on T2-weighted images and TOF source images (p < 0.001). Receiver operating characteristic curves of both T2 and TOF criteria showed that 7 T MRI/MRA had higher sensitivity and specificity than 3 T MRI/MRA. Our findings indicate that 7 T MRI/MRA is superior to 3 T MRI/MRA for the diagnosis of MMD in point of detecting the flow void in basal ganglia by T2-weighted and TOF images.  相似文献   

3.
PurposeTo implement a fast (~ 15 min) MRI protocol for carotid plaque screening using 3D multi-contrast MRI sequences without contrast agent on a 3 Tesla MRI scanner.Materials and methods7 healthy volunteers and 25 patients with clinically confirmed transient ischemic attack or suspected cerebrovascular ischemia were included in this study. The proposed protocol, including 3D T1-weighted and T2-weighted SPACE (variable-flip-angle 3D turbo spin echo), and T1-weighted magnetization prepared rapid acquisition gradient echo (MPRAGE) was performed first and was followed by 2D T1-weighted and T2-weighted turbo spin echo, and post-contrast T1-weighted SPACE sequences. Image quality, number of plaques, and vessel wall thicknesses measured at the intersection of the plaques were evaluated and compared between sequences.ResultsAverage examination time of the proposed protocol was 14.6 min. The average image quality scores of 3D T1-weighted, T2-weighted SPACE, and T1-weighted magnetization prepared rapid acquisition gradient echo were 3.69, 3.75, and 3.48, respectively. There was no significant difference in detecting the number of plaques and vulnerable plaques using pre-contrast 3D images with or without post-contrast T1-weighted SPACE. The 3D SPACE and 2D turbo spin echo sequences had excellent agreement (R = 0.96 for T1-weighted and 0.98 for T2-weighted, p < 0.001) regarding vessel wall thickness measurements.ConclusionThe proposed protocol demonstrated the feasibility of attaining carotid plaque screening within a 15-minute scan, which provided sufficient anatomical coverage and critical diagnostic information. This protocol offers the potential for rapid and reliable screening for carotid plaques without contrast agent.  相似文献   

4.
PurposeTo enable fast reconstruction of undersampled motion-compensated whole-heart 3D coronary magnetic resonance angiography (CMRA) by learning a multi-scale variational neural network (MS-VNN) which allows the acquisition of high-quality 1.2 × 1.2 × 1.2 mm isotropic volumes in a short and predictable scan time.MethodsEighteen healthy subjects and one patient underwent free-breathing 3D CMRA acquisition with variable density spiral-like Cartesian sampling, combined with 2D image navigators for translational motion estimation/compensation. The proposed MS-VNN learns two sets of kernels and activation functions for the magnitude and phase images of the complex-valued data. For the magnitude, a multi-scale approach is applied to better capture the small calibre of the coronaries. Ten subjects were considered for training and validation. Prospectively undersampled motion-compensated data with 5-fold and 9-fold accelerations, from the remaining 9 subjects, were used to evaluate the framework. The proposed approach was compared to Wavelet-based compressed-sensing (CS), conventional VNN, and to an additional fully-sampled (FS) scan.ResultsThe average acquisition time (m:s) was 4:11 for 5-fold, 2:34 for 9-fold acceleration and 18:55 for fully-sampled. Reconstruction time with the proposed MS-VNN was ~14 s. The proposed MS-VNN achieves higher image quality than CS and VNN reconstructions, with quantitative right coronary artery sharpness (CS:43.0%, VNN:43.9%, MS-VNN:47.0%, FS:50.67%) and vessel length (CS:7.4 cm, VNN:7.7 cm, MS-VNN:8.8 cm, FS:9.1 cm) comparable to the FS scan.ConclusionThe proposed MS-VNN enables 5-fold and 9-fold undersampled CMRA acquisitions with comparable image quality that the corresponding fully-sampled scan. The proposed framework achieves extremely fast reconstruction time and does not require tuning of regularization parameters, offering easy integration into clinical workflow.  相似文献   

5.
PurposeTo develop a 3D black-blood T2 mapping sequence with a combination of compressed sensing (CS) and parallel imaging (PI) for carotid wall imaging.Materials and methodsA 3D black-blood fast-spin-echo (FSE) sequence for T2 mapping with CS and PI was developed and validated. Phantom experiments were performed to assess T2 accuracy using a Eurospin Test Object, with different combination of CS and PI acceleration factors. A 2D multi-echo FSE sequence was used as a reference to evaluate the accuracy. The concordance correlation coefficient and Bland-Altman statistics were calculated. Twelve volunteers were scanned twice to determine the repeatability of the sequence and the intraclass correlation coefficient (ICC) was reported. Wall-lumen sharpness was calculated for different CS and PI combinations. Six patients with carotid stenosis > 50% were scanned with optimised sequence. The T2 maps were compared with multi-contrast images.ResultsPhantom scans showed good correlation in T2 measurement between current and reference sequence (r = 0.991). No significant difference was found between different combination of CS and PI accelerations (p = 0.999). Volunteer scans showed good repeatability of T2 measurement (ICC: 0.93, 95% CI 0.84–0.97). The mean T2 of the healthy wall was 48.0 ± 9.5 ms. Overall plaque T2 values from patients were 54.9 ± 12.2 ms. Recent intraplaque haemorrhage and fibrous tissue have higher T2 values than the mean plaque T2 values (88.1 ± 6.8 ms and 62.7 ± 9.3 ms, respectively).ConclusionThis study demonstrates the feasibility of combining CS and PI for accelerating 3D T2 mapping in the carotid artery, with accurate T2 measurements and good repeatability.  相似文献   

6.
PurposeTo establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of < 1 min, for the evaluation of intracranial vessels.Materials and methodsTen healthy volunteers with no unilateral symptomatic arterial stenosis, who underwent 3-tesla MRI, were investigated. Imaging parameters for the fast ACTRESS sequence were set with an acquisition time of 45 s. During post-processing, the first phase in the multi-phase readout, which was defined as the control image, was subtracted from each of the other phases. Thus, four-dimensional (4D)-MRA images of each phase were obtained. The maximum intensity projection was used for the reconstruction of 4D-MRA images and time-to-signal intensity curves (TIC) obtained for each vessel. The area under the curve (AUC), peak time, and maximum signal intensity were obtained from TIC. The different labeling types were broadly divided into six groups: L1, L2, L3, L4, L5, and L6 according to the actual number of labeling pulse.ResultsA total of 5040 regions of interest were evaluated. The peak SI of L3, except for those in the A2 segment of the anterior cerebral artery, was significantly higher than that of L5. However, there were no significant differences between L4 and L5. Although the AUCs of L3 and L4 for anterior circulation were relatively higher than that of the other subgroups, the AUC of L3 was significantly higher than that of L4.ConclusionThe fast ACTRESS was optimized and indicated that the labeling type of L3 was the most appropriate for the well visualization of intracranial arteries. The fast ACTRESS sequence was useful to acquire well-delineated images of intracranial vessels in ˂1 min.  相似文献   

7.
PurposeTo develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolutions (T1w-SPACE) and to compare this technique (hereafter, iSPACE) with alternating with nutation for tailored excitation (DANTE) prepared SPACE sequence (DANTE-SPACE) for their CSF suppression performance around the mid cerebral arteries (MCA) and blood suppression at carotid arteries.Materials and methodsEight volunteers and twelve patients were prospectively recruited in this institutional review board approved study. A custom designed 32-channel coil set covering the intracranial and extracranial arteries was used for signal reception. Imaging was performed in each subject using DANTE-SPACE and iSPACE. Signal-to-noise ratios (SNR) of the vessel walls at the MCA and carotid arteries, and contrast-to-noise ratios (CNR) between vessel wall and CSF at the MCA and between vessel wall and lumen at carotid arteries from the two sequences were compared.ResultsIn volunteers, contrast between CSF and white matter (surrogate for vessel wall signal) at the M2 segments in iSPACE was 67.9% higher than in DANTE-SPACE. At the carotid region, the SNR of vessel wall in iSPACE was 11.6% higher than DANTE-SPACE while the CNR in iSPACE was 13% higher than DANTE-SPACE. In patients, images with 0.6 mm isotropic resolution were obtained in 7.5 min. iSPACE showed 70.9% improvement in CNR between plaque and CSF at the M2 segments compared to DANTE-SPACE.ConclusionSimultaneous extracranial and intracranial arterial wall imaging using iSPACE improved CSF suppression significantly at the M2 segment of MCA while blood suppression was comparable to DANTE-SPACE. The technique achieved 3D images with 0.6 mm isotropic spatial resolution and took 7.5 min using a custom made coil set. Using this technique, intracranial plaque visualization was improved with no observable image SNR degradation.  相似文献   

8.
PurposeTo introduce a new approach to reconstruct high definition vascular images using COnstrained Data Extrapolation (CODE) and evaluate its capability in estimating vessel area and stenosis.Materials and methodsCODE is based on the constraint that the full width half maximum of a vessel can be accurately estimated and, since it represents the best estimate for the width of the object, higher k-space data can be generated from this information. To demonstrate the potential of extracting high definition vessel edges using low resolution data, both simulated and human data were analyzed to better visualize the vessels and to quantify both area and stenosis measurements. The results from CODE using one-fourth of the fully sampled k-space data were compared with a compressed sensing (CS) reconstruction approach using the same total amount of data but spread out between the center of k-space and the outer portions of the original k-space to accelerate data acquisition by a factor of four.ResultsFor a sufficiently high signal-to-noise ratio (SNR) such as 16 (8), we found that objects as small as 3 voxels in the 25% under-sampled data (6 voxels when zero-filled) could be used for CODE and CS and provide an estimate of area with an error < 5% (10%). For estimating up to a 70% stenosis with an SNR of 4, CODE was found to be more robust to noise than CS having a smaller variance albeit a larger bias. Reconstruction times were > 200 (30) times faster for CODE compared to CS in the simulated (human) data.ConclusionCODE was capable of producing sharp sub-voxel edges and accurately estimating stenosis to within 5% for clinically relevant studies of vessels with a width of at least 3 pixels in the low resolution images.  相似文献   

9.
PurposeTo explore feasibility of using the vessel length on time-of-flight (TOF) or simultaneous non-contrast angiography and intraplaque hemorrhage (SNAP) MRA as an imaging biomarker for brain blood flow, by using arterial spin labeling (ASL) perfusion imaging and 3D phase contrast (PC) quantitative flow imaging as references.MethodsIn a population of thirty subjects with carotid atherosclerotic disease, the visible intracranial arteries on TOF and SNAP were semi-automatically traced and the total length of the distal segments was calculated with a dedicated software named iCafe. ASL blood flow was calculated automatically using the recommended hemodynamic model. PC blood flow was obtained by generating cross-sectional arterial images and semi-automatically drawing the lumen contours. Pearson correlation coefficients were used to assess the associations between the different whole-brain or hemispheric blood flow measurements.ResultsUnder the imaging protocol used in this study, TOF vessel length was larger than SNAP vessel length (P < 0.001). Both whole-brain TOF and SNAP vessel length showed a correlation with whole brain ASL and 3D PC blood flow measurements, and the correlation coefficients were higher for SNAP vessel length (TOF vs ASL: R = 0.554, P = 0.002; SNAP vs ASL: R = 0.711, P < 0.001; TOF vs 3D PC: R = 0.358, P = 0.052; SNAP vs 3D PC: R = 0.425, P = 0.019). Similar correlation results were observed for the hemispheric measurements. Hemispheric asymmetry index of SNAP vessel length also showed a significant correlation with hemispheric asymmetry index of ASL cerebral blood flow (R = 0.770, P < 0.001).ConclusionThe results suggest that length of the visible intracranial arteries on TOF or SNAP MRA can serve as a potential imaging marker for brain blood flow.  相似文献   

10.
ObjectiveThe differentiation between an aneurysm and an infundibulum with time-of-flight MRA is often difficult. However, this distinction is important because it affects further patient follow-up. The purpose of this study was to assess the added value of high resolution 7 Tesla MRA for investigating small vascular lesions suspect for an aneurysm or an infundibulum.Materials and methodsWe included patients in whom an intracranial vascular lesion was detected in our University Hospital and in whom the discrimination between a true aneurysms or an infundibulum could not be made on conventional 1.5 or 3 T MRI were included in the study. All patients underwent an additional 7 T time-of-flight MRA at higher spatial resolution.ResultsWe included 6 patients. The age range of the patients was 35–65 years and 5 of them were women. 1 out of 6 had a 1.5 T MRI, the other 5 patients had a 3 T MRI previous to the 7 T MRI. The lesion size varied between 0.9 mm and 2.0 mm. In 5 of the 6 patients the presence of an infundibulum could be proven using the high resolution of the 7 T MRA. All patients tolerated the 7 T MRI well.ConclusionOur results suggest that high resolution and contrast of 7 T MRA provides added diagnostic value in discriminating between intracranial aneurysms and infundibula. This finding may have important consequences for patient follow-up and comfort because it might reduce unnecessary follow-up exams and decrease uncertainty about the diagnosis. Larger studies, however, are needed to confirm our findings.  相似文献   

11.
ObjectivesTo evaluate the diagnostic performance of a new three-dimensional T1-weighted turbo-spin-echo sequence (3D T1-w TSE) compared to 3D contrast-enhanced angiography (CE-MRA) for stenosis measurement and compared to 2D T1-w TSE for intra-plaque hemorrhage (IPH) detection.MethodsEighty three patients underwent carotid MRI, using a new elliptic-centric phase encoding T1-weighted 3D TSE sequence in addition to the clinical protocol.Two observers evaluated image quality, presence of flow artifacts, and presence of intra-plaque hemorrhage, and computed the NASCET degree of stenosis for CE-MRA and for the new sequence. Inter-observer agreement and correlation between 3D TSE and CE-MRA for NASCET stenosis was estimated using Cohen's kappa, and correlation using linear regression and Bland-Altman plots.Histology was performed on endarterectomy samples for 18 patients. Sensitivity and specificity of 2D and 3D TSE for IPH diagnosis were computed.Results3D TSE showed better image quality than 2D TSE (p < 0.05). Interobserver agreement was good (kappa  0.86). Correlation between 3D TSE and CE-MRA was excellent (R = 0.95) for NASCET stenosis. Sensitivity and specificity for IPH diagnosis was 50% and 100% for 2D TSE and 100% and 83% for the 3D TSE.ConclusionsThe new 3D T1-w TSE allows both reliable measures of carotid stenosis, with a slight overestimation compared to CE-MRA (5%), and improved IPH identification, compared to 2D TSE.  相似文献   

12.
PurposeTo develop a RF coil system for joint imaging of intracranial and extracranial arterial vessel wall at 3T.Materials and methodThe coil system consists of a 24-channel head coil combined with an 8-channel carotid coil. It is compared with a standard coil configuration (12-channel head coil + 4-channel neck coil + 8-channel carotid coil) for SNR and g-factors in phantoms and healthy volunteers. The clinical relevance of the proposed coil system is also evaluated in patients.ResultsIn phantom experiments, the SNR of the proposed coil system is 53% higher than the maximum SNR of the standard coil configuration at the center of the phantom which usually corresponds to the intracranial region of the head. The g-factors of the proposed coil system in the sagittal plane are lower than the standard coil configuration (by 10.8% and 26.6% for R = 2 and 4 respectively) in the same experiment. In healthy volunteer experiments, 55% of the pixels have SNR above 100 for the proposed coil system, which is 33% more than that of the standard coil configuration. The maximum g-factors in the standard configuration are higher than those from the new coil design by 12% at R = 2 and up to 36% at R = 4 in the sagittal plane. In patients, in-vivo intracranial and extracranial arterial wall images at an isotropic spatial resolution of 0.6 mm can be acquired using the proposed coil system. Plaques are well depicted from the images.ConclusionsThe performance of the proposed coil set is superior to the standard coil configuration, providing high SNR, low g-factor and good spatial coverage needed for simultaneous high resolution imaging of intracranial and extracranial arterial walls. Images acquired in 7.6 min using the proposed coil system can achieve an isotropic spatial resolution of 0.6 mm and can be used to depict plaques on the intracranial and extracranial arterial walls in patients.  相似文献   

13.
Scanning tunneling microscopy study showed that the (2 × 2) reconstruction on the (001) surface of SrTiO3 should have a surface structure with a 4-fold symmetry. The previously proposed solution for the (2 × 2) reconstruction with the p2gm symmetry only has a 2-fold symmetry. In this study density functional theory study was carried out to propose a possible surface structure with the p4mm surface symmetry which matches the scanning tunneling microscopy images and suggests that two different (2 × 2) surface structures exist. The formation of the (2 × 2) reconstruction with the p4mm symmetry may be due to the kinetics as it has slightly higher surface energy than the one with the p2gm symmetry.  相似文献   

14.
PurposeTo characterize the intracranial vascular features extracted from time of flight (TOF) images and their changes from baseline to follow-up in patients undergoing carotid revascularization, using arterial spin labeling (ASL) cerebral blood flow (CBF) measurement as a reference.MethodsIn this retrospective study, brain TOF and ASL images of 99 subjects, acquired before, within 48 h, and/or 6 months after, carotid revascularization surgery were analyzed. TOF images were analyzed using a custom software (iCafe) to quantify intracranial vascular features, including total vessel length, total vessel volume, and number of branches. Mean whole-brain CBF was calculated from ASL images. ASL scans showing low ASL signal in the entire flow territory of an internal carotid artery (ICA), which may be caused by labeling failure, were excluded. Changes and correlations between time points were analyzed separately for TOF intracranial vascular features and ASL CBF.ResultsSimilar to ASL CBF, TOF vascular features (i.e. total vessel length, total vessel volume and number of branches) increased dramatically from baseline to post-surgery, then returned to a level slightly higher than the baseline in long-term follow-up (All P < 0.05). Correlation between time points was observed for all three TOF vascular features but not for ASL CBF.ConclusionIntracranial vascular features, including total vessel length, total vessel volume and number of branches, extracted from TOF images are useful in detecting brain blood flow changes induced by carotid revascularization surgery.  相似文献   

15.
We studied the atomic arrangements and the phase diagram of two-dimensional (2D) Bi–Sn binary films on Rh(111) with low-energy electron diffraction and scanning tunneling microscopy (STM). The 2D binary films exhibited (“2” × √3)-(Bi,Sn), (√7 × √7)R19°-(Bi,Sn), and (7 × 3√3)-(Bi,Sn) structures, depending on the compositional ratio of Bi and Sn. Atomically resolved STM images revealed that the binary films formed a BiSn3 ordered alloy for the (√7 × √7)R19°-(Bi,Sn) structure and a solid solution alloy for the (“2” × √3)-(Bi,Sn) structure. The atomic configuration for the (7 × 3√3)-(Bi,Sn) structure was closely related to that of (√7 × √7) R19°-(Bi,Sn).  相似文献   

16.
PurposeTo evaluate the feasibility of 3D fast spin-echo (FSE) imaging with compressed sensing (CS) for the assessment of shoulder.Materials and methodsTwenty-nine patients who underwent shoulder MRI including image sets of axial 3D-FSE sequence without CS and with CS, using an acceleration factor of 1.5, were included. Quantitative assessment was performed by calculating the root mean square error (RMSE) and structural similarity index (SSIM). Two musculoskeletal radiologists compared image quality of 3D-FSE sequences without CS and with CS, and scored the qualitative agreement between sequences, using a five-point scale. Diagnostic agreement for pathologic shoulder lesions between the two sequences was evaluated.ResultsThe acquisition time of 3D-FSE MRI was reduced using CS (3 min 23 s vs. 2 min 22 s). Quantitative evaluations showed a significant correlation between the two sequences (r = 0.872–0.993, p < 0.05) and SSIM was in an acceptable range (0.940–0.993; mean ± standard deviation, 0.968 ± 0.018). Qualitative image quality showed good to excellent agreement between 3D-FSE images without CS and with CS. Diagnostic agreement for pathologic shoulder lesions between the two sequences was very good (κ = 0.915–1).ConclusionsThe 3D-FSE sequence with CS is feasible in evaluating the shoulder joint with reduced scan time compared to 3D-FSE without CS.  相似文献   

17.
This work presents the results of the large scale experiments with detonation propagating in hydrogen–air mixtures in partially confined geometries. The main aim of the work was to find the critical conditions for detonation propagation in semi-confined geometries with uniform and non-uniform hydrogen–air mixtures. The experimental facility consisted of rectangular 9 × 3 × 0.6 m channel open from the bottom, acceleration section and test section, safety vessel, gas injection and data acquisition system. Sooted plates technique was used as a witness of the detonation. The rectangular channel was placed in a 100 m3 safety vessel. For uniform hydrogen–air mixtures experiments with four different channel heights h were performed: 8, 5, 3 and 2 cm. The critical hydrogen–air mixture height h* for which the detonation may propagate in a layer is close to the 3 cm which corresponds to approximately three detonation cell sizes. For non-uniform hydrogen–air mixture with hydrogen concentration slope equal approximately ?1.1%H2/cm the critical hydrogen concentration at the top of the layer is approximately equal 26% and the mean detonation layer height is close to the 8.5 cm corresponding to the hydrogen concentration at the bottom of the layer approximately equal 16–17%.  相似文献   

18.
PurposeTo determine the clinical value of routine use of thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique for internal derangements of the knee joint at 3 T.Method and MaterialsThirty-four knees in 34 patients suspected of having internal derangements of the knee joint were included. Following standard 2D MRI protocol including sagittal PDWI, T1WI and T2*WI, coronal fat-suppressed PDWI, and axial fat-suppressed PDWI with 3-4 mm thicknesses, fat-suppressed and water-excitation PDWI using 3D FSE sequences with a variable flip angle technique with 0.6 mm thickness were obtained in coronal plane and the three major planes with 1 mm thickness (3D MRI) was reformatted. The standard 2D MRI protocol and reformatted 3D MRI protocol (three sagittal 2D sequence images plus 3D MRI) were independently analyzed by two radiologists concerning presence or absence of lesions in the menisci, cartilage, and ligament. Interobserver agreements in both the MRI protocols were assessed by weighted-kappa coefficients. Regarding diagnostic accuracy, areas under the receiver operating characteristic curves (Az values) of both the MRI protocols were compared.ResultsThirty-eight meniscal lesions, 39 cartilage lesions, and 20 ligamentous lesions were surgically detected. Excellent interobserver agreements (kappa = 0.91–0.98) were seen in both the MRI protocols, with a slightly better tendency in the reformatted 3D MRI protocol. Average Az values in detection of the meniscal, cartilage, and ligamentous lesions were significantly higher in the reformatted 3D MRI protocol than in the standard 2D MRI protocol (p < 0.01 or p < 0.001).ConclusionRoutine use of reformatted thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique may improve diagnostic accuracy and confidence in detection of internal derangements of the knee joint.  相似文献   

19.
PurposeIn this study, we aimed to evaluate the feasibility of determining the mural invasion depths of colorectal carcinomas using high-spatial-resolution (HSR) quantitative T2 mapping on a 3-T magnetic resonance (MR) scanner.Materials and methodsTwenty colorectal specimens containing adenocarcinomas were imaged on a 3-T MR system equipped with a 4-channel phased-array surface coil. HSR quantitative T2 maps were acquired using a spin-echo sequence with a repetition time/echo time of 7650/22.6–361.6 ms (16 echoes), 87 × 43.5-mm field of view, 2-mm section thickness, 448 × 224 matrix, and average of 1. HSR fast-spin-echo T2-weighted images were also acquired. Differences between the T2 values (ms) of the tumor tissue, colorectal wall layers, and fibrosis were measured, and the MR images and histopathologic findings were compared.ResultsIn all specimens (20/20, 100%), the HSR quantitative T2 maps clearly depicted an 8-layer normal colorectal wall in which the T2 values of each layer differed from those of the adjacent layer(s) (P < 0.001). Using this technique, fibrosis (73.6 ± 9.4 ms) and tumor tissue (104.2 ± 6.4 ms) could also be clearly differentiated (P < 0.001). In 19 samples (95%), the HSR quantitative T2 maps and histopathologic data yielded the same findings regarding the tumor invasion depth.ConclusionsOur results indicate that 3-T HSR quantitative T2 mapping is useful for distinguishing colorectal wall layers and differentiating tumor and fibrotic tissues. Accordingly, this technique could be used to determine mural invasion by colorectal carcinomas with a high level of accuracy.  相似文献   

20.
BackgroundSegmented cine imaging with a steady-state free-precession sequence (Cine-SSFP) is currently the gold standard technique for measuring ventricular volumes and mass, but due to multi breath-hold (BH) requirements, it is prone to misalignment of consecutive slices, time consuming and dependent on respiratory capacity. Real-time cine avoids those limitations, but poor spatial and temporal resolution of conventional sequences has prevented its routine application. We sought to examine the accuracy and feasibility of a newly developed real-time sequence with aggressive under-sampling of k-space using sparse sampling and iterative reconstruction (Cine-RT).MethodsStacks of short-axis cines were acquired covering both ventricles in a 1.5 T system using gold standard Cine-SSFP and Cine-RT. Acquisition parameters for Cine-SSFP were: acquisition matrix of 224 × 196, temporal resolution of 39 ms, retrospective gating, with an average of 8 heartbeats per slice and 1–2 slices/BH. For Cine-RT: acquisition matrix of 224 × 196, sparse sampling net acceleration factor of 11.3, temporal resolution of 41 ms, prospective gating, real-time acquisition of 1 heart-beat/slice and all slices in one BH. LV contours were drawn at end diastole and systole to derive LV volumes and mass.ResultsForty-one consecutive patients (15 male; 41 ± 17 years) in sinus rhythm were successfully included. All images from Cine-SSFP and Cine-RT were considered to have excellent quality. Cine-RT-derived LV volumes and mass were slightly underestimated but strongly correlated with gold standard Cine-SSFP. Inter- and intra-observer analysis presented similar results between both sequences.ConclusionsCine-RT featuring sparse sampling and iterative reconstruction can achieve spatial and temporal resolution equivalent to Cine-SSFP, providing excellent image quality, with similar precision measurements and highly correlated and only slightly underestimated volume and mass values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏