首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
畜禽肉化学成分近红外光谱检测技术研究进展   总被引:4,自引:0,他引:4  
和传统的肉品化学成分检测方法相比,近红外光谱分析是一种能够快速、简单、安全和可同时测定多种化学成分的肉品检测方法。论述了近年来猪、鸡、牛、羊四种动物肉中粗蛋白质、肌间脂肪、脂肪酸、水分、灰分、肌红蛋白和胶原蛋白七种化学成分的近红外光谱分析检测研究进展,并探讨了目前研究中存在的问题及其原因。从已发表的研究结果可以看出,近红外光谱分析具有替代耗时成本高的现有肉品化学检测方法的巨大潜力,特别是用于商业上同步检测多种化学成分。研究大多采用主成分分析法进行特征光谱筛选,偏最小二乘和修正偏最小二乘法建立校正模型,交互验证进行预测结果评价。目前研究热点集中在肉中脂肪酸含量预测模型和应用近红外高光谱图像和多元回归预测肉中化学成分。近红外光谱预测结果差异性较大,这与样品集选择、光谱预处理和建模方法都有很密切的关系。样品选择对近红外预测精度具有重要的意义,非均质肉样影响了近红外化学成分预测精度。总的来说,肌间脂肪、脂肪酸与水分指标预测效果较好,粗蛋白质和肌红蛋白指标预测效果次之,灰分和胶原蛋白指标预测结果较差。  相似文献   

2.
In the present study, visible and near-infrared reflectance spectroscopy were applied to predict quality attributes of duck breast meat. The real color (expressed as lightness, redness, and yellowness) and pH of duck samples were recorded using traditional contact methods and then modeled with their corresponding spectral data by partial least square regression. Before the establishment of prediction models, three different spectral preprocessing methods including first derivative, standard normalized variate, and Savitzky–Golay smoothing were used. Compared to the models obtained from original spectral data set, the predictive capabilities of models based on the spectra after preprocessing were improved effectively. As a result, the determination coefficient of calibration set and prediction set of the best models for lightness, redness, yellowness, and pH parameters were 0.96 and 0.85, 0.94 and 0.94, 0.96 and 0.94, 0.81 and 0.76, respectively. Results demonstrated that visible and near-infrared spectroscopy can become a useful tool for rapid prediction of duck color and pH quality attributes.  相似文献   

3.
基于近红外光谱的杂交水稻种子发芽率测试研究   总被引:1,自引:0,他引:1  
现阶段水稻种子发芽率测试仍然按照传统的农作物种子发芽技术规定进行发芽试验,此方法存在试验周期长、成本高、专业性要求高等缺点,本研究提出一种基于近红外光谱技术的快速、无损测试杂交水稻种子发芽率的新方法。采用人工老化方法在温度45 ℃、湿度100%的条件下分别老化处理2个品种杂交水稻种子0,24,48,72,96,120,144 h;用近红外光谱仪分别采集2个品种不同老化时间段杂交水稻种子光谱数据共280份,随机分成校正集(168份)和检验集(112份);测试不同老化时间段的水稻种子发芽率;以偏最小二乘算法(PLS)建立了回归模型,分析不同光谱波段和比较不同光谱预处理方法对模型精度的影响。2个品种的水稻种子光谱数据采用全波段和标准化+正交信号校正预处理时模型最优,模型校正集决定系数(RC)与验证集相关系数(RP)分别为0.965和0.931,校正标准误差(SEC)与预测标准误差(SEP)分别为1.929和2.899,验证集预测值与真实值之间的相对误差在4.2%以内。研究结果表明利用近红外光谱分析技术进行杂交水稻种子发芽率的快速无损检测是可行的。  相似文献   

4.
利用近红外光谱技术预测粗皮桉木材弹性模量   总被引:3,自引:0,他引:3  
采用近红外光谱分析技术,对粗皮桉木材弹性模量进行了快速预测研究.使用快速傅里叶变换(FFT)分析法和常规力学测试方法测定了粗皮桉木材无疵小试样的弹性模量,并用近红外光谱仪采集试样径切面和弦切面的近红外漫反射光谱,对原始光谱进行二阶导数预处理,并选择410~2 480 nm光谱段建立回归模型.以2/3的试样作为校正集建立弹性模量的偏最小二乘法校正模型,以1/3/的试样作为预测集对模型进行验证.结果表明,粗皮桉木材的弹性模量与近红外光谱之间有较好的相关性,纵向弹性模量和抗弯弹性模量的预测模型的相关系数分别为0.93和0.81,相对分析误差分别为2.70和1.71.利用近红外光谱分析方法可以实现对粗皮桉木材无疵小试样弹性模量的快速预测.  相似文献   

5.
反刍动物精料补充料中肉骨粉快速检测近红外光谱法   总被引:2,自引:0,他引:2  
为探讨利用近红外漫反射光谱技术快速定量分析反刍动物精料补充料中肉骨粉含量的可行性,收集了我国常用的、具有代表性的精料补充料225个和肉骨粉75个,按照不同的肉骨粉含量(0.5%~ 35%)制备样品225个,其中135个为定标集,90个作为独立的验证集。用光栅型近红外光谱仪进行光谱扫描,选择合适的光谱预处理方法和光谱范围,采用改善的偏最小二乘法(MPLS)建立了定量分析 模型,相关系数为0.979,标准差为1.522%,交互验证标准差为1.582%。用90个独立的验证样品对所建立的定量分析模型进行验证,相关系数为0.972,预测标准差为1.764%,RPD值为5.99。结果表明 利用近红外反射光谱法可以分析精补料中肉骨粉的含量,对于丰富我国动物源性饲料的快速检测手段,具有实际应用意义。  相似文献   

6.
建立了牛肉基于TVB-N、菌落总数、pH值和肉色参数L*多个指标的储存期预测模型,利用可见近红外光谱(Vis/NIR)技术结合区间偏最小二乘(iPLS)和遗传算法(GA)建立了各个指标的PLS预测模型,实现了多指标综合无损快速预测4 ℃下牛肉的储存期。用iPLS和iPLS-GA提取有效波长变量建立PLS预测模型,以预测相关系数和预测标准差作为模型评价标准,结果表明用iPLS-GA选择变量建立的各个指标的PLS预测模型均优于全波段和iPLS组合的PLS模型。由多个指标的预测值和储存期的预测模型,对校正集和预测集样品储存期进行预测,其预测相关系数和标准差分别是0.903, 0.897和1.88, 2.24。说明利用光谱技术结合得出的储存期预测模型可以实现多指标综合预测牛肉储存期,为无损快速检测牛肉储存期或货架期提供了一种新方法。   相似文献   

7.
西范坪矿区土壤铜元素的高光谱响应与反演模型研究   总被引:1,自引:0,他引:1  
为解决传统的土壤地球化学测量方法成本高、效率低等问题,研究了利用可见-近红外光谱技术检测土壤重金属含量的简易方法。研究对西范坪矿区土壤反射光谱进行微分、连续统去除等六种变换,利用逐步回归法和皮尔逊相关系数选出对土壤铜含量敏感的特征波段,组成综合特征变量集,再应用不同的特征变量选取方法和参数建立估算模型并检验。结果表明:不同的光谱变换方法对土壤铜含量信息提取能力不同,每种光谱变换都对应特定的敏感波谱区间;基于综合光谱变换信息建立的土壤铜含量反演模型精度优于基于单种光谱变换信息建立的模型;利用综合光谱变换信息建立土壤铜含量反演模型,后向剔除法优于前向引入法和逐步回归法,当Removal取0.20时得到最优回归模型,其模型决定系数R2和预测模型决定系数R2pre分别达到了0.851和0.830,建模均方根误差RMSEC和预测均方根误差RMSEP分别为0.349和0.468 mg·kg-1,能较好地检测土壤铜含量,同时为其他土壤重金属元素的光谱检测提供了思路。  相似文献   

8.
杏贮藏期间可溶性固形物和硬度的近红外光谱检测   总被引:2,自引:0,他引:2  
以杏为材料,研究其贮藏期间可溶性固形物和硬度的近红外漫反射无损检测模型的建立方法。研究发现,定标建模最少样品量为100个。对于可溶性固形物,刚收获样品的校正模型对各贮藏阶段的预测效果均较好,决定系数(r2p)接近0.9、预测均方根误差(RMSEP)在0.6左右及相对分析误差(RPDp)达2.5以上;而且混合阶段模型的预测效果均优于采收及不同贮藏阶段的独立模型,r2p和RPDp分别达0.9和3.0以上、RMSEP在0.3—0.5之间。对于硬度,各阶段独立模型仅能粗略预测相应贮藏时期的样品,而混合阶段模型对各贮藏时期的样品均能实现快速分析,rp2和RMSEP分别在0.8和1.0左右、RPDp达2.0。结果表明近红外漫反射光谱可用于及时评价杏贮藏期间可溶性固形物和硬度的变化。  相似文献   

9.
本文主要对近红外光谱技术在快速测定连翘提取物中连翘苷含量的应用进行了研究。利用近红外漫反射光谱法采集样品的近红外光谱,以HPLC分析值作为参考值,采用偏最小二乘法(PLS)建立连翘苷含量的定量校正模型,并用未知样品对该模型进行验证。所建模型的相关系数(R2)、校正均方差(RM-SEC)和内部交叉验证均方差(RMSECV)分别为0.9745、0.117和0.2392;经外部验证,预测相关系数(r2)和预测均方差(RMSEP)分别为0.9788和0.0776。结果表明该方法操作简便,无污染,结果准确可靠,可用于连翘提取物中连翘苷含量的快速测定。  相似文献   

10.
牛肉化学成分的近红外光谱检测方法的研究   总被引:5,自引:0,他引:5  
通过对整块牛肉和肉馅样品进行扫谱,测定其脂肪、蛋白和水分含量,采用国产 SupNIR-1000 近红外光谱仪,运用人工神经网络(ANN)分别建立肉馅和整块牛肉的脂肪、蛋白和水分的模型.肉馅样品的脂肪模型校正相关系数为0.971、预测相关系数为0.972;蛋白的校正相关系数为0.952、预测相关系数为0.949;水分的校...  相似文献   

11.
近红外光谱法快速评定牛肉品质   总被引:5,自引:0,他引:5  
应用近红外反射光谱技术(NIRS),采用偏最小二乘法(PLS),建立了牛肉理化特性的近红外预测模型。从屠宰加工厂选取经48 h排酸后的里脊、眼肉、腿肉、臀肉、外脊等部位的牛肉样品114份,采用多元散射校正(MSC)、一阶导数、标准正态变量(SNV)预处理方法,谱区为950~1 650 nm,建立牛肉水分、脂肪、蛋白质3个化学参数以及pH、肉色(CEI L*,a*, b*)和剪切力(WBSF)3个物理参数的校正模型。其校正相关系数(R2)分别为0.947 2(水分),0.924 5(脂肪),0.934 6(蛋白质),0.620 2(pH),0.820 3(L*),0.864 6(a*),0.753 0(b*),0.475 9(WBSF)。校正标准差(RMSEC)分别为0.313 3(水分), 0.221 0(脂肪), 1.243 2(蛋白), 0.744 6(pH),1.778 3(L*),1.394 2(a*),1.763 9(b*),1.074 3(WBSF)。应用所建立的模型对30个实际牛肉样品的理化参数进行预测,并对预测值与实测值进行t检验,检验结果显示预测值与实测值差异不显著,说明模型适合于快速评价牛肉的品质。从预测的准确度看,化学指标预测的精确度明显高于物理指标。  相似文献   

12.
ABSTRACT

The feasibility of Fourier transform near-infrared spectroscopy for rapid determination of ethyl pentanoate in Chinese liquor was investigated. A total of 108 liquor samples from production line were analyzed with Fourier transform near-infrared transmission spectroscopy. The calibration model for ethyl pentanoate content prediction was established with partial least square, and validated using internal cross validation. In a calibration set (80 samples), the coefficient of determination was 0.958, with the corresponding root mean square error of cross validation 0.020 g L?1. In a validation set (28 samples), the coefficient of determination was 0.964, with the root mean square errors of prediction 0.023 g L?1, and the bias value (0.005 g L?1) for the validation set was less than the bias confidence limits value (0.009 g L?1), indicating that the resulting near-infrared spectroscopy prediction model has good performance for online rapid determination of ethyl pentanoate in Chinese liquor. The determination of ethyl pentanoate in liquor can be completed in less than 2 min per sample using the near-infrared spectroscopy prediction model. The near-infrared spectroscopy combining chemometrics as a rapid analytical method has a promising application prospect of application in the liquor production field.  相似文献   

13.
With the ever increasing importance of testing drug quality, rapid analytical methods are needed for supervision of Chinese herbal medicines. Near-infrared spectroscopy is one of the most powerful tools in quality assessment of Chinese herbal medicines. In this work, near-infrared spectroscopy was applied to develop a rapid method for quantitative determination of typhaneoside and isorhamnetin-3-O-glucoside in different processed products of Pollen Typhae. A total of 71 batches of samples were collected from different regions in China. After acquisition of near-infrared spectra, different pre-processing methods were compared, and a competitive adaptive reweighted sampling algorithm was used to perform the variable selection. Then a partial least squares regression algorithm was applied to build the quantitative models. The root mean square error of calibration, root mean square error of cross validation, and root mean square error of prediction were 0.0190, 0.0364, and 0.0158%, respectively, for a quantitative model of typhaneoside. The root mean square error of calibration, root mean square error of cross validation, and root mean square error of prediction were 0.0190, 0.0377, and 0.0170%, respectively, for a quantitative model of isorhamnetin-3-O-glucoside. Moreover, the relative prediction deviation values of both quantitative models were larger than 3, indicating good performance of the partial least squares (PLS) models. The results demonstrated that high accuracy prediction of typhaneoside and isorhamnetin-3-O-glucoside could be obtained by near-infrared spectroscopy, to allow an alternative method for quality assessment of different processed products of Pollen Typhae.  相似文献   

14.
Abstract

Secondary metabolites are important components in terms of nutrition and health. Carotenoids and tocopherols, two groups of the fat-soluble components, are also included in this category. There is an increasing interest in the detection of secondary metabolites with near-infrared spectroscopy. However, the number of scientific studies for the detection of these components, especially for tocopherols in corn flour or oil samples by near-infrared reflectance spectroscopy is rather limited. This study was carried out to determine the amount of carotenoids and tocopherols in flour and oil samples of 250 different maize genotypes by near-infrared reflectance spectroscopy using the partial least squares regression modeling method. Liquid chromatography mass spectrophotometry was used as a reference method in order to determine the contents of five carotenoids and four tocopherol subcomponents. The estimation models were created by using the spectral data collected from ground samples, and oil samples extracted from the same flour; along with the results of the reference analysis. The reliability of these models was tested by external validation (n?=?50). The prediction models generated by the spectra taken from corn flour yielded more successful results than the models created with the spectra taken from the oil samples. Among the models compared, the one developed with the spectra taken from flour samples for lutein was the most successful. It is seen that the estimation models generated from flour samples can be used for screening purposes, though different approaches are needed to increase the success of models.  相似文献   

15.
近红外漫反射光谱法预测紫花苜蓿草颗粒营养价值   总被引:9,自引:0,他引:9  
研究旨在探讨利用紫花苜蓿草颗粒样品的近红外漫反射光谱信息,建立能够预测其营养价值的校正模型。采集22份全株草颗粒、19份茎颗粒、19份叶颗粒共60份紫花苜蓿草颗粒样品,其中建模样品45份,检验样品15份。利用傅里叶变换近红外漫反射光谱技术(FT-NIRS)采集各实验样品的近红外漫反射光谱,运用偏最小二乘法(PLS)建立了紫花苜蓿草颗粒粗蛋白(CP)、中性洗涤纤维(NDF)和酸性洗涤纤维(ADF)含量的预测模型。3个预测模型的校正模型建模效果均较好,其交叉检验相关系数(RCV)为0.964 10~0.968 87,交互验证的残差均方根(RMSECV)为0.80%~2.59%。用15个检验样品对模型进行外部检验,预测相关系数(r)为0.966 9~0.974 3,外部验证的残差均方根(RMSEP)为0.85%~2.07%。所建模型的交叉检验和外部检验RPD均大于3,表明近红外光谱分析技术可以准确地预测紫花苜蓿草颗粒的营养价值。  相似文献   

16.
高光谱图像包含了大量的光谱信息和图像信息,采用高光谱成像技术对牛肉品种进行识别。获取可见-近红外(400~1000 nm)光谱范围内的安格斯牛、利木赞牛、秦川牛、西门塔尔牛、荷斯坦奶牛五个品种共252个牛肉样本的高光谱图像。在ENVI软件中对高光谱图像进行阈值分割并构建掩膜图像,获取样本的感兴趣区域(ROI),并结合伪彩色图对牛肉样本的反射率指数进行可视化表达;采用Kennard-Stone(KS)法对样本集进行划分以提高模型的预测性能;对原始光谱采用卷积平滑(SG)、区域归一化(Area normalize)、基线校正(Baseline)、一阶导数(FD)、标准正态变量变换(SNV)及多元散射校正(MSC)等6种方法进行预处理;采用竞争性自适应重加权算法(CARS)提取特征波长。然后利用颜色矩对不同牛肉样本的颜色特征进行提取;对原始光谱图像进行主成分分析,结合灰度共生矩阵(GLCM)算法,提取主要纹理特征。最后结合偏最小二乘判别(PLS-DA)算法建立牛肉样本基于特征波长、颜色特征以及纹理特征的识别模型。KS法将牛肉样本划分为校正集190个,预测集62个;将未经预处理的光谱数据与经过6种不用预处理的光谱数据进行建模分析,结果发现经FD法处理后的光谱数据所建模型的识别率最高;结合CARS法对经FD法预处理后的光谱数据进行特征波长提取,共提取出22个波长;利用颜色矩和GLCM算法分别提取出每个牛肉样本的9个颜色特征、48个纹理特征。将特征波长数据与颜色、纹理特征信息进行融合建模,结果表明,基于特征光谱+纹理特征的模型识别效果最佳,其校正集与预测集识别率分别为98.42%和93.55%,均高于特征光谱数据模型识别率,说明融合纹理特征后使样本分类信息的表达更加全面;融合颜色特征后模型的校正集识别率均有所增加,但预测集识别率稍逊,颜色特征虽携带了部分有效信息,但这些信息与牛肉样本的相关性不大。因此,寻找与牛肉样本相关性更大的颜色特征是提高模型识别率的重要途径之一。该研究结果为牛肉品种的快速无损识别提供了一定的参考。  相似文献   

17.
近红外光谱是近年来发展最快、最引人注目的光谱学技术。主要介绍了近红外光谱技术的基本原理和发展, 包括近红外光谱预处理技术如微分处理、信号平滑等技术的发展和近红外光谱分析模型如多元线性回归、主成分分析、偏最小二乘法和人工神经网络等的发展。综述了国内外近几年来此技术在动物饲料和产品品质检测中的应用。文献调查显示, 近红外光谱分析技术以其快速、无损、不污染环境等诸多优点在国内外饲料和动物产品检测方面得到广泛应用。在饲料分析方面,近红外不仅能用于其常量成分干物质、粗蛋白、粗纤维、粗脂肪等的测定,而且能用于微量成分、有毒有害成分的测定。在动物产品分析方面,该技术已用于禽蛋、牛肉、羊肉、猪肉等的各种物理和化学指标的测定。文中详细给出了已经报道的利用近红外光谱技术测定饲料和动物产品测定指标和光谱处理以及模型建立的情况, 并讨论了近红外光谱快速检测技术的在饲料分析和动物产品分析领域的应用新趋势和局限性。  相似文献   

18.
近红外光谱(NIRS)技术快速测定湖泊沉积物营养组分研究   总被引:2,自引:0,他引:2  
Zan FY  Huo SL  Xi BD  Li QQ  Liu HL 《光谱学与光谱分析》2010,30(10):2624-2627
湖泊沉积物保存了湖泊环境演化的重要信息,但目前还没有建立起快速、准确的湖泊沉积物营养组分组合分析方法。该文利用近红外光谱(NIRS)技术,采用一阶导数、小波滤噪、正交信号校正、小波滤噪+正交信号校正、一阶导数+正交信号校正、正交信号校正+小波压缩6种光谱预处理技术和偏最小二乘(PLS)法相结合在国内建立了NIR光谱测定湖泊沉积物柱芯样品中总碳(TC),总氨(TN),总有机碳(TOC)和总磷(TP)的校正模型,结果表明虽然NIR光谱校正模型对TOC的预测效果不理想,但一阶导数+正交信号校正光谱校正模型对TC和TN,正交信号校正光谱校正模型对TP的预测效果较好,预测相关系数分别为0.759 7(TC),0.865 0(TN)和0.811 2(TP),预测误差(RMSEP)分别为0.13%(TC),0.008 2%(TN)和0.012%(TP)。该研究对于推动我国湖泊沉积物的光谱学特性研究具有重要意义。  相似文献   

19.
为探讨小波压缩算法结合近红外光谱技术在马铃薯全粉还原糖含量检测中的可行性,采用傅里叶变换近红外光谱仪采集了250份马铃薯全粉样品的近红外光谱。分别优化了消失矩、小波系数和主成分因子数,优化结果为10,100和20。基于db小波函数将1 501个马铃薯全粉的近红外光谱变量压缩成100个小波系数。分别以1 501个光谱变量和100个小波系数为变量分别建立了偏最小二乘(PLS)校正模型。以62个未参与建模的样品作为预测集,考察模型的预测能力。经比较,小波压缩结合PLS的校正模型预测结果最优,模型预测相关系数为0.98,预测均方根误差为0.181%。实验结果表明小波压缩算法结合近红外光谱技术有效地保留了有效光谱信息,实现了光谱数据降维,简化了马铃薯全粉还原糖PLS校正模型,提高了模型的预测能力。  相似文献   

20.
应用可见/近红外漫反射光谱对南丰蜜桔维生素C含量进行了无损检测研究.在谱区350~1 800nm,应用主成分分析和偏最小二乘法对经过预处理光谱进行数学建模,主成分数和光谱区间选择分别由完全交互验证和回归系数法确定.定标模型对10个未知样品的预测结果是:预测相关系数为0.813,预测均方差为2.112 mg(100 g)-1,预测偏差为-0.810 mg(100 g)-1.文章表明利用可见/近红外漫反射光谱技术无损检测南丰蜜桔维生素C具有可行性.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号