住宅建筑中相邻房间的侧向传声预测   总被引:1,自引:0,他引:1       下载免费PDF全文
黄险峰  杨宗筱 《声学学报》2018,43(2):253-262
侧向传声作为建筑中声传递的组成部分,对住宅的整体隔声效果具有重要的影响,通过将建筑中相邻房间的各建筑构件划分为若干子系统,应用统计能量分析(Statistical Energy Analysis,SEA)理论,从系统的声功率平衡的角度建立侧向传声的预测模型,在描述各路径的传声规律的同时确定主要传声路径。研究结果表明:当外围护结构为重质结构,且为匀质单一材料构造时,(1)在低频处,全程通过两相邻房间的侧墙或楼板的非通过隔墙的侧向路径成为主要侧向传声路径;(2)在中高频,各侧向路径的声压级差趋于一致,此时的建筑隔声性能取决于通过隔墙的直接路径上的声传递;(3)采用重质隔墙可以缩小侧向传声影响的频率范围。本研究为改善住宅的声环境质量及建筑隔声设计提供了理论依据。   相似文献   

2.
Flanking transmission has significant effects on the overall sound insulation of two adjacent rooms within a residence building. This study investigates the mechanism of the sound flanking transmission by dividing it into several subsystems with the statistical energy analysis method. The sound energy equations of these subsystems are obtained first, and then,the sound transmissions on each flanking path are predicted and the dominant sound transmission path is determined by solving these equations and calculating the total loss factors of the subsystems and coupling loss factors between subsystems. With respect to a masonry building with heavy-weight homogeneous structure, the results show that:(1) the flanking transmission paths instead of the separating wall may become the dominant ones at low frequencies;(2) all sound transmissions on the flanking paths tend to be consistent at medium and high frequencies, so the sound insulation between two adjacent rooms depends on the direct path of the separating wall;(3) heavy-weight separating walls can be used to reduce the frequency range of the flanking transmission.  相似文献   

3.
The sound intensity method is usually recommended instead of the pressure method in the presence of strong flanking transmission. Especially when small and/or heavy specimens are tested, the flanking often causes problems in laboratories practicing only the pressure method. The purpose of this study was to determine experimentally the difference between the maximum sound reduction indices obtained by the intensity method, RI,max, and by the pressure method, Rmax. In addition, the influence of adding room absorption to the receiving room was studied. The experiments were carried out in an ordinary two-room test laboratory. The exact value of RI,max was estimated by applying a fitting equation to the measured data points. The fitting equation involved the dependence of the pressure-intensity indicator on measured acoustical parameters. In an empty receiving room, the difference between RI,max and Rmax was 4-15 dB, depending on frequency. When the average reverberation time was reduced from 3.5 to 0.6 s, the values of RI,max increased by 2-10 dB compared to the results in the empty room. Thus, it is possible to measure wall structures having 9-22 dB better sound reduction index using the intensity method than with the pressure method. This facilitates the measurements of small and/or heavy specimens in the presence of flanking. Moreover, when new laboratories are designed, the intensity method is an alternative to the pressure method which presupposes expensive isolation structures between the rooms.  相似文献   

4.
This paper is concerned with the analysis of the dependence of low frequency impact sound transmission through floating floor systems on in situ matched resonances. The evidence for the floating floor matched resonances has been found previously considering laboratory and numerical tests for one concrete slab and floating floor with varying resilient layers. In the present paper, considering laboratory and field tests for concrete slabs and floating floors with different plan configurations, this evidence is strengthened as differences between laboratory and field measurements of the impact sound level were negligible for the bare concrete slab but not with the floating floor installed. These results were also confirmed numerically. The analysis indicates that the dependence of low frequency impact sound transmission through floating floor systems on in situ matched resonances should be considered in addition to the conventional single degree of freedom models in order to improve accuracy.  相似文献   

5.
Airborne sound transmission between adjacent rooms can be predicted using the Standard EN 12354-1 (ISO 15712-1), which is equivalent to a first-order approximation of statistical energy analysis (SEA). This paper analyses airborne sound transmission between adjacent rooms in a masonry building, by comparing results obtained from EN 12354-1 to SEA predictions and measurements. It is shown that the restriction of the Standard to first-order flanking paths can lead to large errors in predictions when compared to measurements and SEA results taking into account all transmission paths. This is observed both for individual flanking paths and overall transmission between rooms, for which the Standard provides results similar to those obtained by the first-order approximation of SEA. The paper also looks at possible reasons why previous studies using the approach in EN 12354 have generally shown good agreement with measurements.  相似文献   

6.
Sound transmission between adjoining rooms is often influenced by a flanking sound passing through open windows placed in the exterior wall of the two rooms. It is important to predict such flanking sound propagation when considering the sound insulation between the adjoining rooms. In this paper, a chart for estimating the distance attenuation of the flanking sound, which is obtained from analysis using the boundary integral equation method, is first provided. Next, 1:10 scale model experiments are carried out. The experimental results are in good agreement with the chart, the effectiveness of the chart thus being verified.  相似文献   

7.
Measurements of the normalised flanking sound level difference of different gypsum board flanking walls are reported. Results of a “standard” wall construction confirmed some results of the current draft standard of DIN 4109. Different constructions with various junction details and different wall constructions are described and measurement results are presented. By additional measurements on the walls, a prediction model for the weighted flanking level difference is suggested, based on the methodology of EN 12354. For the flanking transmission prediction of path Ff, three transmission paths are proposed. The model gives good agreement between calculated and measured weighted flanking level difference except for the case where the transmission along the inner lining of the flanking wall is dominant. In this case the prediction underestimates measurements by up to 7 dB.  相似文献   

8.
In additional to the screw connection affecting the sound transmission characteristics of the panel-stud partition,the spacing of screws is also considered as a factor in predicting the sound insulation of the partition.It can be modeled either as a series of independent point connections,or as a line connection depending on the screw spacing.For small screw spacing,the connection between panel and stud can be treated as a line connection,from which a higher sound transmission effect can be achieved.Whilst for a larger screw spacing,it can be treated as an independent point connection,from which a lesser sound transmission through the partition can be achieved accordingly.The distinction between these two kinds of connection is also related to the frequency.Usually,half bending wavelength of a panel will be treated as a distinct frequency.Experimental results of double leaf partition with diverse screw spacing significantly demonstrated their influences on sound reduction.Some prediction methods for partitions with different screw spacing are also reviewed in this paper.It should be noted that the impact of screw spacing effecting on the sound insulation of partitions of wood stud and light-weight metal stud is different.  相似文献   

9.
An experimentally validated analytical model has been developed in order to investigate the effect on impact sound transmission at low frequencies of location of the impact, type of floor, edge conditions, floor and room dimensions, position of the receiver and room absorption. The model was developed in order to allow rapid repeated calculations necessary for a parametric survey, described in a companion paper. The analytical model uses natural mode analysis to predict the sound field generated in rectangular rooms by point sound sources and the point excitation of homogeneous rectangular plates with different edge conditions. A floor-room model of the sound field generated in a room by a vibrating floor also has been derived. Laboratory and in situ measurements confirm that the models can be used to estimate impact sound transmission at low frequencies. The approach applies to homogeneous simply supported base plates of uniform thickness with homogenous floating floors, which again were experimentally validated in the laboratory and in situ.  相似文献   

10.
A calculation model is presented for the sound transmission between dwellings by partitions and by flanking structures, based on the application of classical theory.The most important data needed are the sound reduction index for direct transmission of the different structures and the vibration level differences across junctions. Information on the reduction index is given, based on theory, taking into account the influence of boundary conditions by means of the structural reverberation time in situ. The vibration level differences have been determined for different junctions on the basis of in situ measurements. Under some—reasonable—restrictions this model gives the same results as would be achieved by applying the so-called Statistical Energy Analysis (SEA).Comparison between calculation and measurement for seventy-five different situations shows good agreement, the average predictions being correct with a standard deviation of 1·5 dB.  相似文献   

11.
Sound insulation prediction models in European and International Standards use the vibration reduction index to calculate flanking transmission across junctions of walls and floors. These standards contain empirical relationships between the ratio of mass per unit areas for the walls/floors that form the junction and a frequency-independent vibration reduction index. However, calculations using wave theory show that there is a stronger relationship between the ratio of characteristic moment impedances and the transmission loss from which the vibration reduction index can subsequently be calculated. In addition, the assumption of frequency-independent vibration reduction indices has been shown to be incorrect due to in-plane wave generation at the junction. Therefore numerical experiments with FEM, SFEM and wave theory have been used to develop new regression curves between these variables for the low-, mid- and high-frequency ranges. The junctions considered were L-, T- and X-junctions formed from heavyweight walls and floors. These new relationships have been implemented in the prediction models and they tend to improve the agreement between the measured and predicted airborne and impact sound insulation.  相似文献   

12.
This work presents a theoretical study of the sound transmission into a finite cylinder under coupled structural and acoustic vibration. Particular attention of this study is focused on evaluating a dimensionless quantity, "noise reduction," for characterizing noise transmission into a small cylindrical enclosure. An analytical expression of the exterior sound pressure resulting from an oblique plane wave impinging upon the cylindrical shell is first presented, which is approximated from the exterior sound pressure for an infinite cylindrical structure. Next, the analytical solution of the interior sound pressure is computed using modal-interaction theory for the coupled structural acoustic system. These results are then used to derive the analytical formula for the noise reduction. Finally, the model is used to predict and characterize the sound transmission into a ChamberCore cylindrical structure, and the results are compared with experimental data. The effects of incidence angle and internal acoustic damping on the sound transmission into the cylinder are also parametrically studied.  相似文献   

13.
This paper presents an experimental investigation of passively control of sound transmission through a double glazed window by using arrangement of Helmholtz resonators (HRs), which are commonly used for narrow band control application. The laboratory experiments were performed placing the window between reverberation chamber and anechoic chamber. The window was subject to diffuse field, approximate normal wave and oblique wave acoustic excitations. Three sets of HRs were designed and installed in cavity of window. The sound control performances at far-field were measured. The control performances from varying the number of HRs, incident acoustic field, excitation sources (band-limited white noise and traffic noise examples) are presented and discussed in detail. It is shown that a considerable reduction of the transmitted sound pressure levels has been achieved around the mass–air–mass resonance frequency (50–120 Hz). The obtained reductions in the transmitted sound pressure illustrate the potentials of HRs for improving the sound insulation characteristics of double glazed window. The experimental results also indicate that only tuning the HRs to the mass–air–mass resonance frequency does not guarantee the best possible insulation of the sound transmission.  相似文献   

14.
This paper presents a method of calculating sound build up, steady state and sound reduction phenomena from the impulse response of rooms. The noise components of both the testing signal and the room response are omitted and wave phenomena occurring in the room are also neglected. A situation corresponding to the geometrical propagation of sound is thus simulated. The resulting formulae are an extension of corresponding methods for the numerical modelling of acoustical fields in rooms. In this way, as well as the impulse response, sound build up and reverberation curves may also be obtained. An example using the ray tracing technique is presented.  相似文献   

15.
实验室隔声测量中试件洞填隙墙传声影响的检验   总被引:1,自引:0,他引:1       下载免费PDF全文
谭华 《应用声学》2009,28(1):76-80
文章探讨了实验室建筑构件隔声测量中填隙墙传声影响的检验与修正方法。通过实验分析,给出了三种可用于不同隔声量构件的门、窗和玻璃试件隔声测量的填隙墙构造方式。  相似文献   

16.
基于高速列车减振降噪需求,本文应用Biot提出的多孔弹性介质声传播理论,采用传递矩阵法理论推导了典型分层结构的隔声量计算公式,给出了空气层与多孔材料对分层复合结构隔声特性的影响。将传递矩阵与遗传算法相结合,对特定中低频段内的复合结构隔声特性进行了优化。研究结果表明:空气层和多孔材料有助于分层复合结构隔声量的提高,特别是空气层对低频隔声有很好的促进作用,另外空气层与多孔材料的分配情况也影响着隔声效果。含有空气层的复合结构在提高隔声量的同时降低了结构的总体重量,实现了高速列车隔声材料低能耗和轻量化的设计目标。  相似文献   

17.
Precast panels are widely used for the construction of large industrial buildings, trade centres and apartment houses. These buildings have to comply with prescribed noise and thermal requirements, so the possibility to accurately estimate the sound reduction index of such panels is of vital importance. The sound reduction index can be determined through measurements carried out in a laboratory or on an already mounted real-scale panel, but both solutions present problems. For example, precast structures consisting of two concrete panels coupled via an interlayer can be very bulky and heavy, and measurements in standard sound transmission laboratories may be impossible to carry out. In some countries, predictions based on theoretical models are accepted in lieu of measurements. Following this approach, the application of simple models, not accounting for the influence of coincidence and of losses, is not sufficient to make acceptable predictions. In this paper, an alternative method to estimate the sound reduction index of precast panels is proposed. Different panels have been considered in the study, each of which has been modelled by a mathematical representation found in the literature. It will be shown that all of these models can be synthesised by a common mathematical formulation, allowing the sound reduction index to be determined from point mobility measurements. The effectiveness of the new method has been investigated by comparing predicted and measured results, obtained in a sound transmission laboratory satisfying existing ISO standards.  相似文献   

18.
An impulse response technique has been investigated by application to the open screens for obtaining sound transmission loss. The measurements of such screens according to ISO 140 were also presented. The predicted results calculated by a model which is based on Huygen's principle and Kirchhoff's formulation have shown good agreements with the results obtained by impulse method. The method requires no specialist acoustic facilities and measurement systems can be portable.  相似文献   

19.
The laboratory test chamber described in this paper was designed to provide a test facility for the measurement of airborne sound insulation of party walls and their associated flanking construction. Initially developed as a research tool to overcome the need to carry out field measurements on new dwelling types, the results obtained in the chamber were found to be in close agreement with the results of field measurements in dwellings with similar constructional detailing. It is concluded that a chamber of this type provides a simple and economic means of assessing in the laboratory the airborne sound insulation of dwellings.  相似文献   

20.
In an investigation of the overall precision of airborne sound insulation determinations in laboratory conditions 10 different samples were measured, according to the general procedure described in ISO 140/III, in an horizontal transmission chamber, with lateral flanking transmission. Measurements were carried out according to a prescribed programme to investigate the repeatability, r, and reproducibility, Re, in the results, within the same laboratory. Two different operators carried out 15 replicates, five per day during three consecutive days. Each operator performed the test under repeatability conditions: that is, using the same instrumentation, without removing the samples and with the environmental conditions kept constant. Between operators, certain parts of the experimental set-up were different: i.e., the measuring samples had been removed and reinstalled and the environmental conditions were slightly different. The statistical parameters, r and Re′, were first obtained for each sample level separately in order to investigate any dependence with level. Successively, in order to get an improvement in precision, an overall factorial variance analysis was carried out for all levels simultaneously. The whole treatment was performed for each third octave frequency band between 100 and 3150 Hz separately, as well as for the weighted apparent reduction index, Rw.  相似文献   