共查询到10条相似文献,搜索用时 140 毫秒
1.
Anna C. Stamm Chadwick L. Wright Michael V. Knopp Petra Schmalbrock Johannes T. Heverhagen 《Magnetic resonance imaging》2013
Purpose
Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.Materials and Methods
The Institutional Review Board-approved study included eight healthy volunteers (age: 36±10 years; three female, five male). All subjects provided written informed consent. ToF and PC MRAs were obtained at 1.5, 3 and 7 T. Signal intensities of the large, primary vessels of the Circle of Willis were measured, and signal-to-noise ratios were calculated. Visualization of smaller first- and second-order branch arteries of the Circle of Willis was also evaluated.Results
The results show that both ToF and PC MRAs allow the depiction of the large primary vessels of the Circle of Willis at all field strengths. Ultrahigh field (7 T) provides only small increases in the signal-to-noise ratio in these primary vessels due to the smaller voxel size acquired. However, ultrahigh-field MRA provides better visualization of the first- and second-order branch arteries with both ToF and PC approaches. Therefore, ultrahigh-field MRA may become an important tool in future neuroradiology research and clinical care. 相似文献2.
von Morze C Purcell DD Banerjee S Xu D Mukherjee P Kelley DA Majumdar S Vigneron DB 《Magnetic resonance imaging》2008,26(10):1329-1333
Purpose
Greater spatial resolution in intracranial three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) is possible at higher field strengths, due to the increased contrast-to-noise ratio (CNR) from the higher signal-to-noise ratio and the improved background suppression. However, at very high fields, spatial resolution is limited in practice by the acquisition time required for sequential phase encoding. In this study, we applied parallel imaging to 7T TOF MRA studies of normal volunteers and patients with vascular disease, in order to obtain very high resolution (0.12 mm3) images within a reasonable scan time.Materials and Methods
Custom parallel imaging acquisition and reconstruction methods were developed for 7T MRA, based on generalized autocalibrating partially parallel acquisition (GRAPPA). The techniques were compared and applied to studies of seven normal volunteers and three patients with cerebrovascular disease.Results
The technique produced high resolution studies free from discernible reconstruction artifacts in all subjects and provided excellent depiction of vascular pathology in patients.Conclusions
7T TOF MRA with parallel imaging is a valuable noninvasive angiographic technique that can attain very high spatial resolution. 相似文献3.
Minoru Maehara Koshi Ikeda Hiroaki Kurokawa Naoto Ohmura Shigeki Ikeda Yuzo Hirokawa Saori Maehara Keita Utsunomiya Noboru Tanigawa Satoshi Sawada 《Magnetic resonance imaging》2014
Purpose
To investigate whether image quality can be improved using liquid perfluorocarbon pads (Sat Pad) and clarify the optimal fat-suppression method among chemical shift selective (CHESS), water excitation (WEX), and short TI inversion recovery (STIR) methods in diffusion-weighted imaging (DWI) of the head and neck using 3-T magnetic resonance imaging. Correlations between results of visual inspection and quantitative analysis were also examined.Material and Methods
This study was approved by our Institutional Review Board and informed consent was waived. DWI was performed on 25 subjects with/without Sat Pad and using three fat-suppression methods (6 patterns). Image quality was evaluated visually (4-point scales and lesion-depiction capability) and by quantitative analysis (signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)). Two-way repeated-measures analysis of variance (ANOVA) was used to detect significant differences in scores of visual evaluation, SNR, and CNR.Results
Mean visual evaluation scores were significantly higher with Sat Pad using STIR than without Sat Pad for all fat-suppression methods (P < 0.05). DWI with Sat Pad using STIR tended to be useful for depicting lesions. DWI using STIR showed reduced W-SNR (W: whole area of depicted structure) and CNR (between semispinalis capitis muscle and subcutaneous fat) due to fewer artifacts and uniform fat suppression.Conclusion
Combining Sat Pad with STIR provides good image quality for visual inspections. When numerous artifacts are present and fat suppression is insufficient, higher SNR and CNR do not always provide good diagnostic image quality. 相似文献4.
Purpose
The purpose of the study was to validate the diagnostic performance of high-resolution isovolumetric magnetic resonance arthrography (MRA) for intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist as compared to conventional MR imaging (MRI).Materials and methods
Forty-eight patients with traumatic TFCC tears at arthroscopy were enrolled. All patients had underwent proton-density- and T2-weighted MRI before arthrography and three-dimensional T1 high-resolution isovolumetric examination (3D-THRIVE) MRA on a 3-T MR. We assessed the presence of scapholunate interosseous ligament (SLIL)/lunotriquetral interosseous ligament (LTIL) or TFCC tears using the arthroscopy as a gold standard.Results
Arthroscopy revealed 37 TFCC central tears, 15 TFCC peripheral tears, 20 SLIL tears and 13 LTIL tears. Sensitivities of MRI and MRA were 70.3% and 94.6% for detection of TFCC central tears, 60.0% and 93.3% for detection of TFCC peripheral tears, 65.0% and 85.0% for SLIL tears, and 61.5% and 84.6% for LTIL tears. The specificity of the MRI was 100% for the detection of ligaments and TFCC tears. The specificities of the MRA for detection of TFCC central tears, TFCC peripheral tears, SLIL tears and LTIL tears were 100%, 97%, 96.4% and 100%, respectively.Conclusion
Isovolumetric 3D-THRIVE wrist MRA provided better results for depiction of intrinsic ligament and TFCC tears than wrist MRI. 相似文献5.
Chang-Ki Kang Myung-Kyun Woo Suk-Min Hong Young-Bo Kim Zang-Hee Cho 《Magnetic resonance imaging》2014
Purpose
To investigate intracranial microvascular images with transceiver radio-frequency (RF) coils at ultra-high field 7 T magnetic resonance imaging (MRI).Materials and methods
We designed several types of RF coils for the study of 7 T magnetic resonance angiography and analyzed quantitatively each coil's performance in terms of the signal-to-noise ratio (SNR) profiles to evaluate the usefulness of RF coils for microvascular imaging applications. We also obtained the microvascular images with different resolutions and parallel imaging technique.Results
The overlapped 6-channel (ch) transceiver coil exhibited the highest performance for angiographic imaging. Although other multi-channel coils, such as 4- or 8-ch, were also suitable for fast imaging, these coils performed poorly in homogeneity or SNR for angiographic imaging. Furthermore, the 8-ch coil was poor in SNR at the center of the brain, while it had the highest SNR at the periphery.Conclusion
The present study has demonstrated that the overlapped 6-ch coil with large-size loop coils provided the best performance for microvascular imaging or angiography with the ultra-high-field 7 T MRI, mainly because of its long penetration depth together with high SNR. 相似文献6.
Jing Liu Petter Dyverfeldt Gabriel Acevedo-Bolton Michael Hope David Saloner 《Magnetic resonance imaging》2014
Purpose
To investigate an effective time-resolved variable-density random undersampling scheme combined with an efficient parallel image reconstruction method for highly accelerated aortic 4D flow MR imaging with high reconstruction accuracy.Materials and Methods
Variable-density Poisson-disk sampling (vPDS) was applied in both the phase-slice encoding plane and the temporal domain to accelerate the time-resolved 3D Cartesian acquisition of flow imaging. In order to generate an improved initial solution for the iterative self-consistent parallel imaging method (SPIRiT), a sample-selective view sharing reconstruction for time-resolved random undersampling (STIRRUP) was introduced. The performance of different undersampling and image reconstruction schemes were evaluated by retrospectively applying those to fully sampled data sets obtained from three healthy subjects and a flow phantom.Results
Undersampling pattern based on the combination of time-resolved vPDS, the temporal sharing scheme STIRRUP, and parallel imaging SPIRiT, were able to achieve 6-fold accelerated 4D flow MRI with high accuracy using a small number of coils (N = 5). The normalized root mean square error between aorta flow waveforms obtained with the acceleration method and the fully sampled data in three healthy subjects was 0.04 ± 0.02, and the difference in peak-systolic mean velocity was − 0.29 ± 2.56 cm/s.Conclusion
Qualitative and quantitative evaluation of our preliminary results demonstrate that time-resolved variable-density random sampling is efficient for highly accelerating 4D flow imaging while maintaining image reconstruction accuracy. 相似文献7.
Christina L. Sammet Xiangyu Yang Peter A. Wassenaar Eric C. Bourekas Brian A. Yuh Frank Shellock Steffen Sammet Michael V. Knopp 《Magnetic resonance imaging》2013
Purpose
The purpose was to evaluate radiofrequency (RF)-related heating of commonly used extracranial neurosurgical implants in 7-T magnetic resonance imaging (MRI).Materials and methods
Experiments were performed using a 7-T MR system equipped with a transmit/receive RF head coil. Four commonly used titanium neurosurgical implants were studied using a test procedure adapted from the American Society for Testing and Materials Standard F2182-11a. Implants (n = 4) were tested with an MRI turbo spin echo pulse sequence designed to achieve maximum RF exposure [specific absorption rate (SAR) level = 9.9 W/kg], which was further validated by performing calorimetry. Maximum temperature increases near each implant's surface were measured using fiberoptic temperature probes in a gelled-saline-filled phantom that mimicked the conductive properties of soft tissue. Measurement results were compared to literature data for patient safety.Results
The highest achievable phantom averaged SAR was determined by calorimetry to be 2.0 ± 0.1 W/kg due to the highly conservative SAR estimation model used by this 7-T MR system. The maximum temperature increase at this SAR level was below 1.0 °C for all extracranial neurosurgical implants that underwent testing.Conclusion
The findings indicated that RF-related heating under the conditions used in this investigation is not a significant safety concern for patients with the particular extracranial neurosurgical implants evaluated in this study. 相似文献8.
Masahiro Tanabe Katsuyoshi Ito Ayame Shimizu Takeshi Fujita Hideko Onoda Shigenari Yamatogi Yasuo Washida Naofumi Matsunaga 《Magnetic resonance imaging》2009
Purpose
The aim of this study was to determine the adequate MR sequence for the lesion conspicuity of hepatocellular lesions with increased iron uptake on superparamagnetic iron oxide (SPIO)-enhanced MRI.Materials and Methods
SPIO-enhanced MRI was performed using a 1.5-T system. Among 25 patients with hypovascular hepatocellular nodules on contrast-enhanced dynamic CT (no early enhancement at arterial phase and hypoattenuation at equilibrium phase), 39 lesions with increased iron uptake on SPIO-enhanced MRI were evaluated. SPIO-enhanced MRI included (1) T1-weighted in-phase gradient recalled echo (GRE) images, (2) T2-weighted fast spin echo (FSE) images, (3) T2*-weighted GRE with moderate TE (7 ms) and (4) long TE (12 ms). The lesion-to-liver contrast-to-noise ratios of the hepatocellular nodule and the signal-to-noise ratio (SNR) of the hepatic parenchyma were calculated by one radiologist for a quantitative assessment. MR images were reviewed retrospectively by two independent radiologists to compare the subjective lesion conspicuity in each image set based on a four-point rating scale.Result
The mean lesion-to-liver contrast-to-noise ratios with T2*-weighted GRE with moderate TE (7 ms) was highest (5.79±3.71) and was significantly higher than those with T1-weighted, in-phase images (3.79±3.23, P<.01), T2-weighted images (2.72±1.52, P<.001) and T2*-weighted GRE with long TE (12 ms) (3.93±2.69, P<.05). The subjective rating of lesion conspicuity was best on the T2*-weighted GRE with moderate TE (7 ms), followed by that on the T2*-weighted GRE with moderate TE (7 ms; P<.05).Conclusion
T2*-weighted GRE sequence with moderate TE (7 ms) showed high lesion-to-liver contrast-to-noise ratios in hepatocellular lesions with increased iron uptake on SPIO-enhanced MRI, indicating better lesion conspicuity of hypointense hepatocellular nodules in cirrhosis or chronic hepatitis. 相似文献9.
Bin Zhou Hong ShanDan Li Zai-Bo JiangJie-Sheng Qian Kang-Shun ZhuMing-Sheng Huang Xiao-Chun Meng 《Magnetic resonance imaging》2010
Purpose
In vivo magnetic resonance (MR) tracking of magnetically labeled bone marrow mesenchymal stem cells (BMSCs) administered via the mesenteric vein to rats with liver fibrosis.Materials and Methods
Rat BMSCs were labeled with superparamagnetic iron oxide (SPIO) and the characteristics of the BMSCs after labeling were investigated. Eighteen rats with CCL4-induced liver fibrosis were randomized to three groups to receive SPIO-labeled BMSCs (BMSC-labeled group), cell-free SPIO (SPIO group), or unlabeled BMSCs (control group). MR imaging of the liver was performed at different time points, and signal-to-noise ratio (SNR) of the liver was measured. In vivo distribution of delivered BMSCs was assessed by histological analysis.Results
Labeling of BMSCs with SPIO did not significantly alter cell viability and proliferation activity. In BMSC-labeled group, the liver SNR immediately decreased from 8.56±0.26 to 3.53±0.41 at 1 h post injection and remained at a significantly lower level till 12 days (P<.05 versus the level before). By contrast, the liver SNR of the SPIO group almost recovered to the preinjection level (P=.125) at 3 days after a transient decrease. In control group, the liver SNR demonstrated no significant difference at the tested time points. Additionally, Prussian blue-positive cells were mainly distributed in the liver parenchyma, especially in injured areas.Conclusion
The magnetically labeled BMSCs infused through the mesenteric vein can be detected in the fibrotic liver of rats using in vivo MR imaging up to 12 days after injection. 相似文献10.
Ahmed M. Gharib Homeira Zahiri Jatin Matta Roderic I. Pettigrew Khaled Z. Abd-Elmoniem 《Magnetic resonance imaging》2013