首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 427 毫秒
1.
The study of flow dynamics in complex geometry vessels is highly important in various biomedical applications where the knowledge of the mechanic interactions between the moving fluid and the housing media plays a key role for the determination of the parameters of interest, including the effect of blood flow on the possible rupture of atherosclerotic plaques. Doppler Optical Coherence Tomography (DOCT), as a functional extension of Optical Coherence Tomography (OCT), is an optic, non-contact, noninvasive technique able to achieve detailed analysis of the flow/vessel interactions. It allows simultaneous high resolution imaging (∼10 μm typical) of the morphology and composition of the vessel and determination of the flow velocity distribution along the measured cross-section. We applied DOCT system to image high-resolution one-dimensional and multi-dimensional velocity distribution profiles of Newtonian and non-Newtonian fluids flowing in vessels with complex geometry, including Y-shaped and T-shaped vessels, vessels with aneurism, bifurcated vessels with deployed stent and scaffolds. The phantoms were built to mimic typical shapes of human blood vessels, enabling preliminary analysis of the interaction between flow dynamics and the (complex) geometry of the vessels and also to map the related velocity profiles at several inlet volume flow rates. Feasibility studies for quantitative observation of the turbulence of flows arising within the complex geometry vessels are discussed. In addition, DOCT technique was also applied for monitoring cerebral mouse blood flow in vivo. Two-dimensional DOCT images of complex flow velocity profiles in blood vessel phantoms and in vivo sub-cranial mouse blood flow velocities distributions are presented.  相似文献   

2.
Self-referenced Doppler optical coherence tomography   总被引:1,自引:0,他引:1  
Yazdanfar S  Izatt JA 《Optics letters》2002,27(23):2085-2087
Doppler optical coherence tomography (DOCT) allows simultaneous micrometer-scale resolution cross-sectional imaging of tissue structure and blood flow. We demonstrate a fiber-optic polarization-diversity-based differential phase contrast DOCT system as a method to perform self-referenced velocimetry in highly scattering media. Using this strategy, we reduced common-mode interferometer noise to <1 Hz and improved Doppler estimates in a scattering flow phantom by a factor of 5.  相似文献   

3.
Pulsed Gradient Spin Echo (PGSE) NMR methods may be used to measure the asymptotic dispersion coefficient as well as the velocity autocorrelation function (VACF) in porous media flow. The VACF can be measured in the frequency domain using repetitive gradient pulse trains, and in the time domain using double PGSE encoding. The one dimensional double PGSE method, and the two dimensional velocity exchange experiment (VEXSY) are briefly outlined and their application to flow in monodisperse 0.5 mm diameter beads packs described, both axial and transverse VACFs being examined. The measured correlation times are shown to agree well with calculated values. The asymptotic dispersion coefficients agree with literature values in the case of transverse flow while in axial flow it is shown that asymptotic conditions are not achieved, even for observation times longer than the correlation time for flow around a bead.  相似文献   

4.
Vascular Doppler optical coherence tomography(DOCT) images with weak boundaries are usually difficult for most algorithms to segment. We propose a modified random walk(MRW) algorithm with a novel regularization for the segmentation of DOCT vessel images. Based on MRW, we perform automatic boundary detection of the vascular wall from intensity images and boundary extraction of the blood flowing region from Doppler phase images. Dice, sensitivity, and specificity coefficients were adopted to verify the segmentation performance. The experimental study on DOCT images of the mouse femoral artery showed the effectiveness of our proposed method, yielding three-dimensional visualization and quantitative evaluation of the vessel.  相似文献   

5.
An elliptical microelectromechanical system (MEMS) membrane mirror is electrostatically actuated to dynamically adjust the optical beam focus and track the axial scanning of the coherence gate in a Doppler optical coherence tomography (DOCT) system at 8 kHz. The MEMS mirror is designed to maintain a constant numerical aperture of approximately 0.13 and a spot size of approximately 6.7 microm over an imaging depth of 1mm in water, which improves imaging performance in resolving microspheres in gel samples and Doppler shift estimation precision in a flow phantom. The mirror's small size (1.4 mm x 1 mm) will allow integration with endoscopic MEMS-DOCT for in vivo applications.  相似文献   

6.
Behar V  Adam D  Friedman Z 《Ultrasonics》2003,41(5):385-395
Conventional ultrasound color flow mapping systems estimate and visualize only the axial velocity component. To obtain the transverse velocity component a modification of a multiple-beam method is proposed. The new two-dimensional color flow mapping system has a small size and consists of three transducers. The central transducer is an appodized and focused phased array. The other transducers are unfocused probes. Three transducers act as receivers and the central transducer operates as a transmitter. All receivers acquire rf scan lines that are then processed to estimate three axial velocity components using an autocorrelation method. These estimates are then combined to estimate the transverse velocity component, taking into account the geometric relationships among three transducers. Two algorithms for transverse velocity estimation are proposed. The first uses the Doppler angle estimate for calculation of the transverse velocity component. The other algorithm calculates the transverse velocity component directly from the axial components. The accuracy of the flow velocity estimators is estimated by simulations. Analysis of accuracy allows choosing the more effective algorithm for two-dimensional velocity estimation, which is insensitive to variations of the Doppler angle.  相似文献   

7.
We have developed a novel phase-resolved optical coherence tomography (OCT) and optical Doppler tomography (ODT) system that uses phase information derived from a Hilbert transformation to image blood flow in human skin with fast scanning speed and high velocity sensitivity. Using the phase change between sequential scans to construct flow-velocity imaging, this technique decouples spatial resolution and velocity sensitivity in flow images and increases imaging speed by more than 2 orders of magnitude without compromising spatial resolution or velocity sensitivity. The minimum flow velocity that can be detected with an axial-line scanning speed of 400 Hz and an average phase change over eight sequential scans is as low as 10 microm/s, while a spatial resolution of 10 microm is maintained. Using this technique, we present what are to our knowledge the first phase-resolved OCT/ODT images of blood flow in human skin.  相似文献   

8.
Wang RK  Ma Z 《Optics letters》2006,31(20):3001-3003
We present a new, simple method to suppress texture pattern artifacts induced by the optical heterogeneity of tissues to improve the performance of flow imaging for real-time phase-resolved optical Doppler tomography. The method performs transverse scanning of the probe beam in the forward and then reverse directions, and it takes average of the spatial phase changes between them to obtain the final velocity image. It relies on the fact that the phase changes between successive axial scans due to the optical heterogeneity of the sample are time independent, while those due to the moving particles are time dependent. We experimentally demonstrate this method by real-time imaging of a flow phantom.  相似文献   

9.
Lines are induced on the surface of a photosensitive (FOTURAN) glass by focused femtosecond laser transverse writing with scanning velocity in a wide range of 40- 1800μm/s. The formed lines are analyzed using scanning electron microscope (SEM) and optical microscope (OM). It is observed that three distinct morphologies of lines are produced depending on the scanning velocity. Lines written in low velocity level (40 - 100 μm/s) and high velocity level (1000 - 1800 μm/s) are uniform and regular, while those written in moderate velocity level (150 - 600 μm/s) are rough. The influence of scanning velocity is explained based on different pulses overlapping or cumulative dose of laser exposure in irradiated area. Fabrication of shallow groove on the surface is also demonstrated.  相似文献   

10.
An L  Wang RK 《Optics letters》2011,36(6):831-833
This Letter presents a useful method that combines the full range complex Fourier domain optical coherence tomography (OCT) with the ultrahigh sensitive optical microangiography (OMAG) to achieve full range complex imaging of blood flow within microcirculatory tissue beds in vivo. We propose to use the fast scanning axis to realize the full range complex imaging, while using the slow axis to achieve OMAG imaging of blood flow. We demonstrate the proposed method by using a high speed 1310?nm OCT/OMAG system running at 92?kHz line scan rate to image the flow phantoms in vitro, and the blood flows in tissue beds in vivo.  相似文献   

11.
We describe a novel optical system for bidirectional color Doppler imaging of flow in biological tissues with micrometer-scale resolution and demonstrate its use for in vivo imaging of blood flow in an animal model. Our technique, color Doppler optical coherence tomography (CDOCT), performs spatially localized optical Doppler velocimetry by use of scanning low-coherence interferometry. CDOCT is an extension of optical coherence tomography (OCT), employing coherent signal-acquisition electronics and joint time-frequency analysis algorithms to perform flow imaging simultaneous with conventional OCT imaging. Cross-sectional maps of blood flow velocity with <50-microm spatial resolution and <0.6-mm/s velocity precision were obtained through intact skin in living hamster subdermal tissue. This technology has several potential medical applications.  相似文献   

12.
赵晨  陈志彦  丁志华  李鹏  沈毅  倪秧 《物理学报》2014,63(19):194201-194201
针对玻璃缺陷在线无损检测的迫切需求,本文报道了一种基于线照明并行谱域光学相干层析成像系统的大视场检测系统.该系统采用快速面阵CMOS相机,单次拍摄即可获取完整的横截面(B-scan)图像.基于线照明面阵探测器的并行谱域光学相干层析成像系统,可以同时获取沿线照明方向各位置处的深度分辨信息,避免了横向扫描机构的应用.研制系统的轴向分辨率为17.9μm,并行方向上的横向分辨率55.7μm,扫描方向上的横向分辨率为24.8μm,轴向扫描速率为128 000 A-scan/s,横向视场为32 mm,空气中成像深度大于6 mm,成像灵敏度达到62 dB以上.利用研制的线照明并行谱域光学相干层析成像系统,开展了不同类型玻璃表面及其内部缺陷的检测应用研究.  相似文献   

13.
We report on a new detection scheme for Fourier domain optical coherence microscopy that exhibits high transverse resolution along an axially extended focal range. Nearly constant transverse resolution of approximately 1.5 microm along a focal range of 200 microm is experimentally verified with a maximum sensitivity of 105 dB. A broad-bandwidth Ti:sapphire laser allowed for an axial resolution of 3 microm in air.  相似文献   

14.
To study the three-dimensional (3-D) behavior produced by complex filters, we have extended the expressions for the axial and the transverse gain to the case in which the best image plane is not near the paraxial focus. Super-Gaussian phase filters are proposed to control the 3-D image response of an optical system. Super-Gaussian phase filters depend on several parameters that modify the shape of the phase filter, producing tunable control of the 3-D response of the optical system. The filters are capable of producing a wide range of optical effects: transverse superresolution with high depth of focus, 3-D superresolution, and transverse apodization with different axial responses.  相似文献   

15.
Liu L  Deng X  Yang L  Wang G  Xu Z 《Optics letters》2000,25(23):1711-1713
Combining differential confocal microscopy and an annular pupil filter, we obtained the normalized axial intensity distribution curve of an optical system. We used the sharp slopes of the axial response curve of the optical system to measure the surface profile of a reflection grating. Experimental results prove that this method can extend the axial dynamic range and improve the transverse resolution of three-dimensional profilometry by sacrificing axial resolution.  相似文献   

16.
An optical coherence microscopy system based on line illumination and detection is demonstrated. The system uses a Linnik-type interferometer illuminated by a broadband Ti:sapphire laser and detected by a high-speed, line-scan CCD camera. This approach is less sensitive to incoherent scattering and sample motion than full-field imaging. Spatial resolutions of approximately 2 microm x approximately 3 microm(transverse x axial) are achieved. The sensitivity of the system is 93 dB with averaging over 30 line scans. En face real time, cellular-level imaging of biological tissues is demonstrated at approximately 2 frames/s.  相似文献   

17.
Munk P  Jensen JA 《Ultrasonics》2000,37(10):661-665
The most used estimation method for calculating the blood velocity in commercial scanners is the autocorrelation approach. The calculation of the mean velocity used in this method depends on the center frequency of the interacting ultrasound pulse which downshifts as a function of depth, introducing a bias. A new velocity estimator for the mean axial velocity is presented. The estimation principle is based on the 2D Fourier transform and the Radon transform. The input data are a sequence of RF data forming a 2D data input, one column for each pulse emission. A 2D segment is selected for a specific depth. This data segment is first transformed by a 2D Fourier transform, and the result is then transformed by a Radon transform. The center of gravity for the angles of the lines intersecting the origin of the R-theta coordinate system in the Radon domain gives the mean axial velocity for the data segment. The benefit of this method is an estimate of the mean axial velocity which is independent of the center frequency of the propagating ultrasound pulse. The estimate will only depend on f(s) and f(pr f). Results of the estimation method is presented based on both simple generated RF harmonic data for different signal/noise ratios and simulated acoustic RF responses from a 3D measurement situation with an array transducer and a tube with plug flow. The new method shows improvement with a factor of 1.5-4 on the standard deviation on the estimated mean velocity for the simulated case.  相似文献   

18.
Lauri  J.  Bykov  A. V.  Priezzhev  A. V.  Myllylä  R. 《Laser Physics》2011,21(4):813-817
Time domain Doppler Optical Coherence Tomography (DOCT) technique was applied to measure flow velocity profiles in highly scattering media. We analyzed the distortions of the measured velocity profiles of the 1% Intralipid solution flow embedded into the scattering medium at different embedding depths. For this purpose a tissue phantom consisting of a plain glass capillary (inner diameter 0.3 mm) embedded into a slab of Intralipid solution mimicking human skin was designed. The measured flow velocity profiles and behavior of distortions caused by multiple scattering are shown.  相似文献   

19.
Ren H  Brecke KM  Ding Z  Zhao Y  Nelson JS  Chen Z 《Optics letters》2002,27(6):409-411
The Doppler bandwidth extracted from the standard deviation of the frequency shift in phase-resolved functional optical coherence tomography (F-OCT) was used to image the velocity component that is transverse to the optical probing beam. It was found that above a certain threshold level the Doppler bandwidth is a linear function of flow velocity and that the effective numerical aperture of the optical objective in the sample arm determines the slope of this dependence. The Doppler bandwidth permits accurate measurement of flow velocity without the need for precise determination of flow direction when the Doppler flow angle is within +/-15 degrees perpendicular to the probing beam. Such an approach extends the dynamic range of flow velocity measurements obtained with the phase-resolved F-OCT.  相似文献   

20.
Wang Y  Wang R 《Optics letters》2010,35(21):3538-3540
We present an autocorrelation method to quantitatively map transverse particle-flow velocity with a Fourier-domain optical coherence tomography system. This method is derived from the intensity fluctuation of the backscattered light modulated by flowing particles. When passing through the probe beam, moving particles encode a transit time into the backscattered light. The slope of the normalized autocorrelation function of the backscattered light is proportional to the transverse velocity. The proposed method is experimentally verified using an intralipid scattering flow phantom.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号