首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Continuous wave electron paramagnetic resonance imaging for in vivo mapping of spin distribution and spectral shape requires rapid data acquisition. A spectral-spatial imaging technique is presented that provides an order of magnitude reduction in acquisition time, compared to iterative tomographic reprojection. The proposed approach assumes that spectral shapes in the sample are well-approximated by members from a parametric family of functions. A model is developed for the spectra measured with magnetic field modulation. Parameters defining the spin distribution and spectral shapes are then determined directly from the measurements using maximum a posteriori probability estimation. The approach does not suffer approximation error from limited sweep width of the main magnetic field and explicitly incorporates the variability in signal-to-noise ratio versus strength of magnetic field gradient. The processing technique is experimentally demonstrated on a one-dimensional phantom containing a nitroxide spin label with constant g-factor. Using an L-band EPR spectrometer, spectral shapes and spin distribution are accurately recovered from two projections and a spectral window which is comparable to the maximum linewidth of the sample.  相似文献   

2.
A frequency modulation (FM) method was developed to measure electron paramagnetic resonance (EPR) absorption. The first-derivative spectrum of 1,1-diphenyl-2-picrylhydrazyl (DPPH) powder was measured with this FM method. Frequency modulation of up to 1.6 MHz (peak-to-peak) was achieved at a microwave carrier frequency of 1.1 GHz. This corresponds to a magnetic field modulation of 57microT (peak-to-peak) at 40.3 mT. By using a tunable microwave resonator and automatic control systems, we achieved a practical continuous-wave (CW) EPR spectrometer that incorporates the FM method. In the present experiments, the EPR signal intensity was proportional to the magnitude of frequency modulation. The background signal at the modulation frequency (1 kHz) for EPR detection was also proportional to the magnitude of frequency modulation. An automatic matching control (AMC) system reduced the amplitude of noise in microwave detection and improved the baseline stability. Distortion of the spectral lineshape was seen when the spectrometer settings were not appropriate, e.g., with a lack of the open-loop gain in automatic tuning control (ATC). FM is an alternative to field modulation when the side-effect of field modulation is detrimental for EPR detection. The present spectroscopic technique based on the FM scheme is useful for measuring the first derivative with respect to the microwave frequency in investigations of electron-spin-related phenomena.  相似文献   

3.
Magnetic field modulation in CW electron paramagnetic resonance (EPR) is used for signal detection. However, it can also distort signal lineshape. In experiments where the linewidth information is of particular importance, small modulation amplitude is usually used to limit the lineshape distortion. The use of small modulation amplitude, however, results in low signal-to-noise ratio and therefore affects the precision of linewidth measurements. Recently, a new spectral simulation model has been developed enabling accurate fitting of modulation-broadened EPR spectra in liquids. Since the use of large modulation amplitude (over-modulation) can significantly enhance the EPR signal, the precision of linewidth measurements is therefore greatly improved. We investigated the over-modulation technique in EPR oximetry experiments using the oxygen-sensing probe lithium octa-n-butoxy-substitued naphthalocyanine (LiNc-BuO). Modulation amplitudes 2-18 times the intrinsic linewidth of the probe were applied to increase the spectral signal-to-noise ratio. The intrinsic linewidth of the probe at different oxygen concentrations was accurately extracted through curve fitting from the enhanced spectra. Thus, we demonstrated that the over-modulation model is also applicable to particulate oxygen-sensing probes such as LiNc-BuO and that the lineshape broadening induced by oxygen is separable from that induced by over-modulation. Therefore, the over-modulation technique can be used to enhance sensitivity and improve linewidth measurements for EPR oximetry with particulate oxygen-sensing probes with Lorentzian lineshape. It should be particularly useful for in vivo oxygen measurements, in which direct linewidth measurements may not be feasible due to inadequate signal-to-noise ratio.  相似文献   

4.
Rapid field scan on the order of T/s using high frequency sinusoidal or triangular sweep fields superimposed on the main Zeeman field, was used for direct detection of signals without low-frequency field modulation. Simultaneous application of space-encoding rotating field gradients have been employed to perform fast CW EPR imaging using direct detection that could, in principle, approach the speed of pulsed FT EPR imaging. The method takes advantage of the well-known rapid-scan strategy in CW NMR and EPR that allows arbitrarily fast field sweep and the simultaneous application of spinning gradients that allows fast spatial encoding. This leads to fast functional EPR imaging and, depending on the spin concentration, spectrometer sensitivity and detection band width, can provide improved temporal resolution that is important to interrogate dynamics of spin perfusion, pharmacokinetics, spectral spatial imaging, dynamic oxymetry, etc.  相似文献   

5.
We report a difference in the spectral lineshapes of continuous-wave (CW) electron paramagnetic resonance (EPR) spectroscopy between field and frequency modulation. This finding addresses the long-standing question of the effect of modulation in EPR absorption. We compared the first-derivative EPR spectra at 1.1 GHz for lithium phthalocyanine crystals, which have a single narrow linewidth in the EPR absorption spectrum, using field and frequency modulation. The experimental findings suggest that unpaired electrons have different behaviors under perturbation due to field and frequency modulation.  相似文献   

6.
Magnetic field gradient modulation is one of the techniques to obtain an electron paramagnetic resonance (EPR) spectrum in a selected region of the sample. In this study, the magnetic field gradient modulation using a triangular wave was performed to overcome a problem during the sine wave modulation. Plastic materials were used for the bobbins and cases of the electromagnet to reduce the eddy current loss and drive the gradient coils in three-dimensional directions at a frequency of over 160 Hz. While the EPR signal splitting in a nonselected region, which is a problem in spectral analysis, was observed during the simulation and the actual measurement with the sine wave gradient modulation, the EPR signal broadening without splitting was observed in those with the triangular wave modulation. Thus, it is postulated that the triangular wave is more suitable than the sine one for the field gradient modulation. The spatial resolution was determined to be about 4 or 2 mm at the field gradient of 1 or 2 mT/cm, respectively. The separation of the EPR spectra of two types of radicals was also made by the triangular wave gradient modulation. Authors' address: Hidekatsu Yokoyama, Department of Pharmaceutical Sciences, International University of Health and Welfare, 2600-1, Kitakanemaru, Ohtawara 324-8501, Japan  相似文献   

7.
Electron paramagnetic resonance imaging (EPRI) provides direct detection and mapping of free radicals. The continuous wave (CW) EPRI technique, in particular, has been widely used in a variety of applications in the fields of biology and medicine due to its high sensitivity and applicability to a wide range of free radicals and paramagnetic species. However, the technique requires long image acquisition periods, and this limits its use for many in vivo applications where relatively rapid changes occur in the magnitude and distribution of spins. Therefore, there has been a great need to develop fast EPRI techniques. We report the development of a fast 3D CW EPRI technique using spiral magnetic field gradient. By spiraling the magnetic field gradient and stepping the main magnetic field, this approach acquires a 3D image in one sweep of the main magnetic field, enabling significant reduction of the imaging time. A direct one-stage 3D image reconstruction algorithm, modified for reconstruction of the EPR images from the projections acquired with the spiral magnetic field gradient, was used. We demonstrated using a home-built L-band EPR system that the spiral magnetic field gradient technique enabled a 4-7-fold accelerated acquisition of projections. This technique has great potential for in vivo studies of free radicals and their metabolism.  相似文献   

8.
曹江伟  王锐  王颖  白建民  魏福林 《物理学报》2016,65(5):57501-057501
基于隧穿磁电阻效应(TMR)的磁场传感器具有很高的磁场灵敏度, 但同时噪声也较大,有效抑制TMR磁场传感器的噪声, 尤其是低频噪声的抑制对于其在高灵敏度要求场合的应用具有重要的意义. 本文采用高精度数据采集卡搭建了噪声测量系统, 测量了全桥结构TMR磁场传感器的噪声频谱图, 发现TMR传感器的噪声在低频段表现为1/f特性, 同时噪声功率谱密度与工作电流平方成正比关系; 低频噪声在自由层翻转区间内噪声急剧增大, 证明了1/f噪声主要来源于磁噪声, 这一结果为TMR磁场传感器的噪声特性优化指明了方向.  相似文献   

9.
This communication reports on post-processing of continuous wave EPR spectra by a digital convolution with filter functions that are subjected to differentiation or the Kramers-Kr?nig transform analytically. In case of differentiation, such a procedure improves spectral resolution in the higher harmonics enhancing the relative amplitude of sharp spectral features over the broad lines. At the same time high-frequency noise is suppressed through filtering. These features are illustrated on an example of a Lorentzian filter function that has a principal advantage of adding a known magnitude of homogeneous broadening to the spectral shapes. Such spectral distortion could be easily and accurately accounted for in the consequent least-squares data modeling. Application examples include calculation of higher harmonics from pure absorption echo-detected EPR spectra and resolving small hyperfine coupling that are unnoticeable in conventional first derivative EPR spectra. Another example involves speedy and automatic separation of fast and broad slow-motion components from spin-label EPR spectra without explicit simulation of the slow motion spectrum. The method is illustrated on examples of X-band EPR spectra of partially aggregated membrane peptides.  相似文献   

10.
A recent survey of nonlinear continuous-wave (CW) EPR methods revealed that the first-harmonic absorption EPR signal, detected 90 degrees out of phase with respect to the Zeeman modulation (V(1)(')-EPR), is the most appropriate for determining spin-lattice relaxation enhancements of spin labels (V. A. Livshits, T. Páli, and D. Marsh, 1998, J. Magn. Reson. 134, 113-123). The sensitivity of such V(1)(')-EPR spectra to molecular rotational motion is investigated here by spectral simulations for nitroxyl spin labels, over the entire range of rotational correlation times. Determination of the effective spin-lattice relaxation times is less dependent on rotational mobility than for other nonlinear CW EPR methods, especially at a Zeeman modulation frequency of 25 kHz which is particularly appropriate for spin labels. This relative insensitivity to molecular motion further enhances the usefulness of the V(1)(')-EPR method. Calibrations of the out-of-phase to in-phase spectral intensity (and amplitude) ratios are given as a function of spin-lattice relaxation time, for the full range of spin-label rotational correlation times. Experimental measurements on spin labels in the slow, intermediate, and fast motional regimes of molecular rotation are used to test and validate the method.  相似文献   

11.
We theoretically investigate the spectral measurement errors that are apt to occur in continuous wave (CW) cavity ringdown (CRD) techniques suffering intracavity Doppler shifts. In the typical CW CRD scheme based on a cavity sweep operation for the resonant coupling of a probe laser into a ringdown cavity, the intracavity probe light detunes gradually over time, carrying time-dependent loss information of an absorption feature. Frequency-drifting ringdown signals are theoretically modelled and found to result in erroneous absorption spectra that exhibit the frequency shift of absorption profiles as well as linewidth broadening. PACS 42.62.Fi; 42.60.Da; 42.25.BS  相似文献   

12.
13.
High-field electron paramagnetic resonance (EPR) experiments to monitor binding of lipophilic Gd(III) complexes to human serum albumin (HSA) are described. It was observed that magnetic interactions between the nitroxide moiety ofn-doxyl-stearic acids bound to HSA and Gd(III) complexes resulted in broadening of nitroxide continuous-wave EPR spectra. The broadening effect can be well described by a one-parameter model of additional Lorentzian broadening At 95 GHz, continuous-wave EPR spectra from Gd(III) complexes are fully resolved from the nitroxide signal allowing for simultaneous and independent line shape analysis. Analysis of the line width broadening effects for spectra from a series ofn-doxyl-stearic acids bound to HSA indicated a progressive decrease of spin label-Gd(III) magnetic interactions along the fatty acid (FA) binding channel, consistent with binding of Gd-DOTAP complex in the vicinity of the main FA binding site. The substantial difference in spin label-metal interactions along the FA binding channel for lipophilic Gd(III) complexes with different chelates is indicative of binding to different sites. We also report measurements of dissociation constant for noncovalent binding of Gd(III) complexes to HSA on the basis of analyses of 95 GHz Gd(III) EPR line shapes.  相似文献   

14.
15.
High resolution pulse EPR methods are usually applied to resolve weak magnetic electron-nuclear or electron-electron interactions that are otherwise unresolved in the EPR spectrum. Complete information regarding different magnetic interactions, namely, principal components and orientation of principal axis system with respect to the molecular frame, can be derived from orientation selective pulsed EPR measurements that are performed at different magnetic field positions within the inhomogeneously broadened EPR spectrum. These experiments are usually carried out consecutively, namely a particular field position is chosen, data are accumulated until the signal to noise ratio is satisfactory, and then the next field position is chosen and data are accumulated. Here we present a new approach for data acquisition of pulsed EPR experiments referred to as parallel acquisition. It is applicable when the spectral width is much broader than the excitation bandwidth of the applied pulse sequence and it is particularly useful for orientation selective pulse EPR experiments. In this approach several pulse EPR measurements are performed within the waiting (repetition) time between consecutive pulse sequences during which spin lattice relaxation takes place. This is achieved by rapidly changing the main magnetic field, B(0), to different values within the EPR spectrum, performing the same experiment on the otherwise idle spins. This scheme represents an efficient utilization of the spectrometer and provides the same spectral information in a shorter time. This approach is demonstrated on W-band orientation selective electron-nuclear double resonance (ENDOR), electron spin echo envelope modulation (ESEEM), electron-electron double resonance (ELDOR)--detected NMR and double electron-electron resonance (DEER) measurements on frozen solutions of nitroxides. We show that a factors of 3-6 reduction in total acquisition time can be obtained, depending on the experiment applied.  相似文献   

16.
Inter-spin distances between 1 nm and 4.5 nm are measured by continuous wave (CW) and pulsed electron paramagnetic resonance (EPR) methods for a series of nitroxide-spin-labelled peptides. The upper distance limit for measuring dipolar coupling by the broadening of the CW spectrum and the lower distance limit for the present optimally-adjusted double electron electron resonance (DEER) set-up are determined and found to be both around 1.6-1.9 nm. The methods for determining distances and corresponding distributions from CW spectral line broadening are reviewed and further developed. Also, the work shows that a correction factor is required for the analysis of inter-spin distances below approximately 2 nm for DEER measurements and this is calculated using the density matrix formalism.  相似文献   

17.
A magnetic system is introduced which consists of three nested rings of permanent magnets of a Halbach dipolar layout and is capable for EPR spectroscopy. Two of the rings can be rotated independently to adjust the magnetic flux in the center and even allow for mechanical field sweeps. The presented prototype achieves a magnetic flux range of 0.0282–0.3013 T with a minimal sweep of 0.15 mT and homogeneity of about 10−3.First applications with CW and pulsed Mims ENDOR as well as ESEEM experiments on a sample of a glycine single crystal doped with 1% copper nitrate demonstrate that flux range, sweep accuracy and homogeneity of this prototype is sufficient for EPR experiments on most solid samples.Together with a recently improved design magnets can be build which could serve as compact and easily transportable replacement of standard electromagnets with negligible consumption of power or coolants.  相似文献   

18.
Selection of the amplitude of magnetic field modulation for continuous wave electron paramagnetic resonance (EPR) often is a trade-off between sensitivity and resolution. Increasing the modulation amplitude improves the signal-to-noise ratio, S/N, at the expense of broadening the signal. Combining information from multiple harmonics of the field-modulated signal is proposed as a method to obtain the first derivative spectrum with minimal broadening and improved signal-to-noise. The harmonics are obtained by digital phase-sensitive detection of the signal at the modulation frequency and its integer multiples. Reconstruction of the first-derivative EPR line is done in the Fourier conjugate domain where each harmonic can be represented as the product of the Fourier transform of the 1st derivative signal with an analytical function. The analytical function for each harmonic can be viewed as a filter. The Fourier transform of the 1st derivative spectrum can be calculated from all available harmonics by solving an optimization problem with the goal of maximizing the S/N. Inverse Fourier transformation of the result produces the 1st derivative EPR line in the magnetic field domain. The use of modulation amplitude greater than linewidth improves the S/N, but does not broaden the reconstructed spectrum. The method works for an arbitrary EPR line shape, but is limited to the case when magnetization instantaneously follows the modulation field, which is known as the adiabatic approximation.  相似文献   

19.
An electron paramagnetic resonance (EPR) setup for line narrowing experiments with fast sample spinning at variable angles between the rotation axis and the static magnetic field is described and applied in the magic-angle sample spinning (MAS) EPR experiment at X-band frequencies (9.5 GHz). Sample spinning speeds up to 17 kHz at temperatures down to 200 K can be achieved with rotors of 4-mm outer and 2.5-mm inner diameter without severe losses in microwave amplitude compared to standard pulse EPR probeheads. A phase cycle is introduced that provides pure absorption MAS EPR spectra and allows one to distinguish between positive and negative frequency offsets (pseudo-quadrature detection). Possible broadening mechanisms in MAS EPR spectra are discussed. It is demonstrated both by theory and by experiment that the MAS EPR experiment requires excitation bandwidths that are comparable to the total spectral width, since otherwise destructive interference between contributions of spins with similar resonance offsets suppresses the signal. Experimental observations on the E(1) center in gamma-irradiated silica glass and on the SO(-)(3) radical in gamma-irradiated sulfamic acid are reported.  相似文献   

20.
Loop-gap resonator (LGR) technology has been extended to W-band (94GHz). One output of a multiarm Q-band (35GHz) EPR bridge was translated to W-band for sample irradiation by mixing with 59 GHz; similarly, the EPR signal was translated back to Q-band for detection. A cavity resonant in the cylindrical TE011 mode suitable for use with 100 kHz field modulation has also been developed. Results using microwave frequency modulation (FM) at 50 kHz as an alternative to magnetic field modulation are described. FM was accomplished by modulating a varactor coupled to the 59 GHz oscillator. A spin-label study of sensitivity was performed under conditions of overmodulation and gamma2H1(2)T1T2<1. EPR spectra were obtained, both absorption and dispersion, by lock-in detection at the fundamental modulation frequency (50 kHz), and also at the second and third harmonics (100 and 150 kHz). Source noise was deleterious in first harmonic spectra, but was very low in second and third harmonic spectra. First harmonic microwave FM was transferred to microwave modulation at second and third harmonics by the spins, thus satisfying the "transfer of modulation" principle. The loaded Q-value of the LGR with sample was 90 (i.e., a bandwidth between 3 dB points of about 1 GHz), the resonator efficiency parameter was calculated to be 9.3 G at one W incident power, and the frequency deviation was 11.3 MHz p-p, which is equivalent to a field modulation amplitude of 4 G. W-band EPR using an LGR is a favorable configuration for microwave FM experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号