首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
Charge transfer multiplet (CTM) theory is a computationally undemanding and highly mature method for simulating the soft X‐ray spectra of first‐row transition metal complexes. However, CTM theory has seldom been applied to the simulation of excited‐state spectra. In this article, the CTM4XAS software package is extended to simulate M2,3‐ and L2,3‐edge spectra for the excited states of first‐row transition metals and also interpret CTM eigenfunctions in terms of Russell–Saunders term symbols. These new programs are used to reinterpret the recently reported excited‐state M2,3‐edge difference spectra of photogenerated ferrocenium cations and to propose alternative assignments for the electronic state of these cations responsible for the spectroscopic features. These new programs were also used to model the L2,3‐edge spectra of FeII compounds during nuclear relaxation following photoinduced spin crossover and to propose spectroscopic signatures for their vibrationally hot states.  相似文献   

2.
X‐ray absorption spectra calculated within an effective one‐electron approach have to be broadened to account for the finite lifetime of the core hole. For methods based on Green's function this can be achieved either by adding a small imaginary part to the energy or by convoluting the spectra on the real axis with a Lorentzian. By analyzing the Fe K‐ and L2,3‐edge spectra it is demonstrated that these procedures lead to identical results only for energies higher than a few core‐level widths above the absorption edge. For energies close to the edge, spurious spectral features may appear if too much weight is put on broadening via the imaginary energy component. Special care should be taken for dichroic spectra at edges which comprise several exchange‐split core levels, such as the L3‐edge of 3d transition metals.  相似文献   

3.
Advances in resonant inelastic X‐ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L3‐edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid‐angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L3‐absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X‐ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27‐ID at the Advanced Photon Source. X‐rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X‐ray measurements, ray‐tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high‐resolution RIXS multi‐crystal analyzer system.  相似文献   

4.
A spectrometer for resonant inelastic X‐ray scattering (RIXS) is proposed where imaging and dispersion actions in two orthogonal planes are combined to deliver a full two‐dimensional map of RIXS intensity in one shot with parallel detection at incoming hvin and outgoing hvout photon energies. Preliminary ray‐tracing simulations with a typical undulator beamline demonstrate a resolving power well above 11000 with both hvin and hvout near 930 eV, with a vast potential for improvement. Combining this instrument – nicknamed hv2 spectrometer – with an X‐ray free‐electron laser source simplifies its technical implementation and enables efficient time‐resolved RIXS experiments.  相似文献   

5.
A method for measuring resonant inelastic X‐ray scattering based on the conversion of X‐ray photons into photoelectrons is presented. The setup is compact, relies on commercially available detectors, and offers significant flexibility. This method is demonstrated at the Linac Coherent Light Source with ~0.5 eV resolution at the cobalt L3‐edge, with signal rates comparable with traditional grating spectrometers.  相似文献   

6.
A novel diced spherical quartz analyzer for use in resonant inelastic X‐ray scattering (RIXS) is introduced, achieving an unprecedented energy resolution of 10.53 meV at the Ir L3 absorption edge (11.215 keV). In this work the fabrication process and the characterization of the analyzer are presented, and an example of a RIXS spectrum of magnetic excitations in a Sr3Ir2O7 sample is shown.  相似文献   

7.
A microfocus X‐ray fluorescence spectroscopy beamline (BL‐16) at the Indian synchrotron radiation facility Indus‐2 has been constructed with an experimental emphasis on environmental, archaeological, biomedical and material science applications involving heavy metal speciation and their localization. The beamline offers a combination of different analytical probes, e.g. X‐ray fluorescence mapping, X‐ray microspectroscopy and total‐external‐reflection fluorescence characterization. The beamline is installed on a bending‐magnet source with a working X‐ray energy range of 4–20 keV, enabling it to excite K‐edges of all elements from S to Nb and L‐edges from Ag to U. The optics of the beamline comprises of a double‐crystal monochromator with Si(111) symmetric and asymmetric crystals and a pair of Kirkpatrick–Baez focusing mirrors. This paper describes the performance of the beamline and its capabilities with examples of measured results.  相似文献   

8.
The SUT‐NANOTEC‐SLRI beamline was constructed in 2012 as the flagship of the SUT‐NANOTEC‐SLRI Joint Research Facility for Synchrotron Utilization, co‐established by Suranaree University of Technology (SUT), National Nanotechnology Center (NANOTEC) and Synchrotron Light Research Institute (SLRI). It is an intermediate‐energy X‐ray absorption spectroscopy (XAS) beamline at SLRI. The beamline delivers an unfocused monochromatic X‐ray beam of tunable photon energy (1.25–10 keV). The maximum normal incident beam size is 13 mm (width) × 1 mm (height) with a photon flux of 3 × 108 to 2 × 1010 photons s?1 (100 mA)?1 varying across photon energies. Details of the beamline and XAS instrumentation are described. To demonstrate the beamline performance, K‐edge XANES spectra of MgO, Al2O3, S8, FeS, FeSO4, Cu, Cu2O and CuO, and EXAFS spectra of Cu and CuO are presented.  相似文献   

9.
10.
Here, soft X‐ray synchrotron radiation transmitted through microchannel plates is studied experimentally. Fine structures of reflection and XANES Si L‐edge spectra detected on the exit of silicon glass microcapillary structures under conditions of total X‐ray reflection are presented and analyzed. The phenomenon of the interaction of channeling radiation with unoccupied electronic states and propagation of X‐ray fluorescence excited in the microchannels is revealed. Investigations of the interaction of monochromatic radiation with the inner‐shell capillary surface and propagation of fluorescence radiation through hollow glass capillary waveguides contribute to the development of novel X‐ray focusing devices in the future.  相似文献   

11.
The effects of varying LiPF6 salt concentration and the presence of lithium bis(oxalate)borate additive on the electronic structure of commonly used lithium‐ion battery electrolyte solvents (ethylene carbonate–dimethyl carbonate and propylene carbonate) have been investigated. X‐ray Raman scattering spectroscopy (a non‐resonant inelastic X‐ray scattering method) was utilized together with a closed‐circle flow cell. Carbon and oxygen K‐edges provide characteristic information on the electronic structure of the electrolyte solutions, which are sensitive to local chemistry. Higher Li+ ion concentration in the solvent manifests itself as a blue‐shift of both the π* feature in the carbon edge and the carbonyl π* feature in the oxygen edge. While these oxygen K‐edge results agree with previous soft X‐ray absorption studies on LiBF4 salt concentration in propylene carbonate, carbon K‐edge spectra reveal a shift in energy, which can be explained with differing ionic conductivities of the electrolyte solutions.  相似文献   

12.
The design, construction and commissioning of a beamline and spectrometer for inelastic soft X‐ray scattering at high resolution in a highly efficient system are presented. Based on the energy‐compensation principle of grating dispersion, the design of the monochromator–spectrometer system greatly enhances the efficiency of measurement of inelastic soft X‐rays scattering. Comprising two bendable gratings, the set‐up effectively diminishes the defocus and coma aberrations. At commissioning, this system showed results of spin‐flip, dd and charge‐transfer excitations of NiO. These results are consistent with published results but exhibit improved spectral resolution and increased efficiency of measurement. The best energy resolution of the set‐up in terms of full width at half‐maximum is 108 meV at an incident photon energy tuned about the Ni L3‐edge.  相似文献   

13.
A single‐crystal momentum‐resolved resonant inelastic X‐ray scattering (RIXS) experiment under high pressure using an originally designed diamond anvil cell (DAC) is reported. The diamond‐in/diamond‐out geometry was adopted with both the incident and scattered beams passing through a 1 mm‐thick diamond. This enabled us to cover wide momentum space keeping the scattering angle condition near 90°. Elastic and inelastic scattering from the diamond was drastically reduced using a pinhole placed after the DAC. Measurement of the momentum‐resolved RIXS spectra of Sr2.5Ca11.5Cu24O41 at the Cu K‐edge was thus successful. Though the inelastic intensity becomes weaker by two orders than the ambient pressure, RIXS spectra both at the center and the edge of the Brillouin zone were obtained at 3 GPa and low‐energy electronic excitations of the cuprate were found to change with pressure.  相似文献   

14.
An X‐ray magnetic circular dichroism (XMCD) study performed at the rare‐earth L2,3‐edges in the RxR1?x′Al2 compounds is presented. It is shown that both R and R′ atoms contribute to the XMCD recorded at the L‐edges of the selected rare‐earth, either R or R′. The amplitude of the XMCD signal is not directly correlated to the magnetization or to the value of the individual (R, R′) magnetic moments, but it is related to the molecular field acting on the rare‐earth tuned in the photoabsorption process. This result closes a longstanding study of the origin of the XMCD at the L‐edge of the rare‐earths in multi‐component systems, allowing a full understanding of the exact nature of these signals.  相似文献   

15.
Core–shell X‐ray emission spectroscopy (XES) is a valuable complement to X‐ray absorption spectroscopy (XAS) techniques. However, XES in the hard X‐ray regime is much less frequently employed than XAS, often as a consequence of the relative scarcity of XES instrumentation having energy resolutions comparable with the relevant core‐hole lifetimes. To address this, a family of inexpensive and easily operated short‐working‐distance X‐ray emission spectrometers has been developed. The use of computer‐aided design and rapid prototype machining of plastics allows customization for various emission lines having energies from ~3 keV to ~10 keV. The specific instrument described here, based on a coarsely diced approximant of the Johansson optic, is intended to study volume collapse in Pr metal and compounds by observing the pressure dependence of the Pr Lα emission spectrum. The collection solid angle is ~50 msr, roughly equivalent to that of six traditional spherically bent crystal analyzers. The miniature X‐ray emission spectrometer (miniXES) methodology will help encourage the adoption and broad application of high‐resolution XES capabilities at hard X‐ray synchrotron facilities.  相似文献   

16.
X‐ray magnetic circular dichroism (XMCD) has become in recent years an outstanding tool for studying magnetism. Its element specificity, inherent to core‐level spectroscopy, combined with the application of magneto‐optical sum rules allows quantitative magnetic measurements at the atomic level. These capabilities are now incorporated as a standard tool for studying the localized magnetism in many systems. However, the application of XMCD to the study of the conduction‐band magnetism is not so straightforward. Here, it is shown that the atomic selectivity is not lost when XMCD probes the delocalized states. On the contrary, it provides a direct way of disentangling the magnetic contributions to the conduction band coming from the different elements in the material. This is demonstrated by monitoring the temperature dependence of the XMCD spectra recorded at the rare‐earth L2‐edge in the case of RT2 (R = rare‐earth, T = 3d transition metal) materials. These results open the possibility of performing element‐specific magnetometry by using a single X‐ray absorption edge.  相似文献   

17.
Moderate‐demagnification higher‐order silicon kinoform focusing lenses have been fabricated to facilitate small‐angle X‐ray photon correlation spectroscopy (XPCS) experiments. The geometric properties of such lenses, their focusing performance and their applicability for XPCS measurements are described. It is concluded that one‐dimensional vertical X‐ray focusing via silicon kinoform lenses significantly increases the usable coherent flux from third‐generation storage‐ring light sources for small‐angle XPCS experiments.  相似文献   

18.
Successful X‐ray photon correlation spectroscopy studies often require that signals be optimized while minimizing power density in the sample to decrease radiation damage and, at free‐electron laser sources, thermal impact. This suggests exploration of scattering outside the Fraunhofer far‐field diffraction limit d2R, where d is the incident beam size, λ is the photon wavelength and R is the sample‐to‐detector distance. Here it is shown that, in an intermediate regime d2/λ > Rdξ/λ, where ξ is the structural correlation length in the material, the ensemble averages of the scattered intensity and of the structure factor are equal. Similarly, in the regime d2/λ > Rdξ(τ)/λ, where ξ(τ) is a time‐dependent dynamics length scale of interest, the ensemble‐averaged correlation functions g1(τ) and g2(τ) of the scattered electric field are also equal to their values in the far‐field limit. This broadens the parameter space for X‐ray photon correlation spectroscopy experiments, but detectors with smaller pixel size and variable focusing are required to more fully exploit the potential for such studies.  相似文献   

19.
The 2–4 keV energy range provides a rich window into many facets of materials science and chemistry. Within this window, P, S, Cl, K and Ca K‐edges may be found along with the L‐edges of industrially important elements from Y through to Sn. Yet, compared with those that cater for energies above ca. 4–5 keV, there are relatively few resources available for X‐ray spectroscopy below these energies. In addition, in situ or operando studies become to varying degrees more challenging than at higher X‐ray energies due to restrictions imposed by the lower energies of the X‐rays upon the design and construction of appropriate sample environments. The XMaS beamline at the ESRF has recently made efforts to extend its operational energy range to include this softer end of the X‐ray spectrum. In this report the resulting performance of this resource for X‐ray spectroscopy is detailed with specific attention drawn to: understanding electrostatic and charge transfer effects at the S K‐edge in ionic liquids; quantification of dilution limits at the Cl K‐ and Rh L3‐edges and structural equilibria in solution; in vacuum deposition and reduction of [RhI(CO)2Cl]2 to γ‐Al2O3; contamination of γ‐Al2O3 by Cl and its potential role in determining the chemical character of supported Rh catalysts; and the development of chlorinated Pd catalysts in `green' solvent systems. Sample environments thus far developed are also presented, characterized and their overall performance evaluated.  相似文献   

20.
An X‐ray magnetic circular dichroism (XMCD) study performed at the Ho L2,3‐edges in Ho6Fe23 as a function of temperature is presented. It is demonstrated that the anomalous temperature dependence of the Ho L2‐edge XMCD signal is due to the magnetic contribution of Fe atoms. By contrast, the Ho L3‐edge XMCD directly reflects the temperature dependence of the Ho magnetic moment. By combining the XMCD at both Ho L2‐ and L3‐edges, the possibility of determining the temperature dependence of the Fe magnetic moment is demonstrated. Then, both μHo(T) and μFe(T) have been determined by tuning only the absorption L‐edges of Ho. This result opens new possibilities of applying XMCD at these absorption edges to obtain quantitative element‐specific magnetic information that is not directly obtained by other experimental tools.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号