水平内微肋管局部凝结换热性能实验与数值求解 总被引:1,自引:0,他引:1
以R11为工质,蒸汽凝结压力为147-265kPa,质量流率4ty153kg/m2s,本文对二维内微肋管和三维内微肋管水平管内凝结分层流区局部换热系数进行了系统的实验。与光管比较,二维内微肋管和三维内微肋管局部凝结换热系数分别提高了147-783%和261-997%。本文首次从理论分析入手建立了二维内微肋管水平管内凝结分层流区局部换热系数分析模型并进行了数值求解。计算结果与本文实验相当吻合。 相似文献
2.
3.
4.
5.
花丝内插物强化竖直管内凝结换热的实验研究 总被引:1,自引:1,他引:0
1前言大空隙率多孔体管内插物-绕花丝内插物,被认为是强化管内凝结换热的最有效途径之一[1].但以往的研究,由于实验雷诺数范围较小,蒸汽速度较低,要正确全面评价其性能尚显不够。本文在原有工作的基础上,进一步完善了实验系统,改进了测试手段,扩大了实验雷诺数范围,并测试了其阻力性能,对花丝内插物强化管内凝结换热进行了较深入全面的实验研究,以全面评价花丝内插物对管内凝结换热的强化效果。2实验系统本文实验系统如图1所示。实验段是一个竖直套管冷凝器,如图2所示.本试验研究蒸汽完全凝结时的传热。凝结水流量采用容积法计… 相似文献
6.
7.
8.
蒸气在倾斜细小直径圆管内的流动凝结换热特性 总被引:1,自引:0,他引:1
细小管内的流动凝结换热具有许多超常换热特性,经典的Nusselt分析方法已不能满足需要。在以往研究的基础上,本文进一步通过实验探析换热温差和蒸气流量对不同直径的细小管内流动凝结换热的影响。研究表明,管径越小,换热温差对凝结换热系数的影响程度越低;通过流量和倾角对凝结换热数的影响,分析了重力引发的流动分层和剪切力对凝结液的排除两种因素对细管传热强化的作用机制。本文的实验结果和用于常规尺度下的通用关联式对比表明,采用细管,管内的流动凝结换热得到无可置疑的强化 相似文献
9.
10.
水和酒精Marangoni凝结换热特性研究 总被引:7,自引:2,他引:5
本文首先构造了一个在常温水冷却时,纯水蒸汽凝结时表面温度差可以达到11℃的黄铜试件。利用该试件在蒸汽流速为0.3m/s时,进行了不同浓度水-酒精混合蒸汽以及纯水蒸汽的凝结换热特性和凝结状态的实验研究。实验结果表明:由于凝结表面存在温度差,水-酒精混合蒸汽出现珠状凝结,凝结换热系数最大可以达到纯水蒸汽凝结的2.8倍;混合蒸汽凝结换热系数随表面过冷度减小而增加,并在较小过冷度时出现陡增;凝结换热量随表面过冷度增加存在最大值;观察得出了不同表面过冷度下不同酒精浓度时的凝结状态。 相似文献
11.
In this study, condensation of pure refrigerant R134a vapor inside a vertical 18° helical microfin tube was experimentally investigated. Tests were performed at saturation pressure of 5.7–5.9 bar with mass fluxes of 20–100 kg/m2s and heat fluxes of 1.7–5.3 kW/m2. The effects of mass flux and the temperature difference between the refrigerant and tube wall (ΔT) on the heat transfer performance were analyzed throughout experimental data. For experiments in which ΔT is more than 2.5°C, the average condensation Nusselt number showed a tendency to be independent from ΔT. Heat transfer enhancement ratio was found to be 1.59–1.71, which is always higher than the heat transfer area enhancement factor (1.55). Fins always act as a turbulence promoter in the given experimental data range. Finally, the most widely used heat transfer coefficient correlations for condensation inside microfin tubes were analyzed through the experimental data. Best fit was obtained with Yu and Koyama's correlation with an absolute mean deviation of 17% and Kedzierski and Goncalves's correlation with an absolute mean deviation of 19%. 相似文献
12.
Accurate, repeatable heat transfer and pressure-drop measurements have been made for condensation of CFC-113 with downflow inside enhanced microfin tubes and tubes containing twisted-wire inserts. In the latter case measurements have also been made for CFC-113/air mixtures. The heat transfer rate was calculated from the coolant flow rate and temperature rise, the latter measured using a 10-junction thermopile with careful attention paid to adequate coolant mixing and isothermal immersion of the thermopile leads. The surface temperature was found from thermocouples embedded in the tube wall. One plain tube, nine microfin tubes (with different fin heights, helix angles, and number of fins), and four twisted-wire inserts (with different wire densities) were tested. Enhancement ratios (i.e., vapor-side heat transfer coefficient for the enhanced tube divided by that for a smooth tube at the same vapor-side temperature difference and vapor inlet velocity) between 1.6 and 5.6 for the microfin tubes and between 1.2 and 1.6 for the twisted-wire inserts were found, with values depending on vapor-side temperature difference, vapor inlet velocity, and air inlet mole fraction in the case of CFC-113/air mixtures. The microfin tubes showed moderate pressure-drop penalties of around 50% compared to the plain tube, while the twisted-wire inserts showed increasing pressure-drop penalty with increasing wire density. 相似文献
13.
14.
A steady state thermodynamic model for an air—cooled finned—tube condenser, used in a typical deep freezer vapour compression
system, operating with pure and refrigerant mixtures has been developed using finite difference method. The heat transfer
aspects in the condenser are treated uniquely for superheated, two—phase and subcooled regimes and studied for various heat
load, pressure, temperature, and mass flow rate. The condensation heat transfer coefficient, the tube length required for
condensation, the degree of subcooling, and the temperature glide for different ambient temperatures are estimated. The simulation
and the experimental results are in good agreement. 相似文献