1.
Self-referenced Doppler optical coherence tomography   总被引:1,自引:0,他引:1  
Yazdanfar S  Izatt JA 《Optics letters》2002,27(23):2085-2087
Doppler optical coherence tomography (DOCT) allows simultaneous micrometer-scale resolution cross-sectional imaging of tissue structure and blood flow. We demonstrate a fiber-optic polarization-diversity-based differential phase contrast DOCT system as a method to perform self-referenced velocimetry in highly scattering media. Using this strategy, we reduced common-mode interferometer noise to <1 Hz and improved Doppler estimates in a scattering flow phantom by a factor of 5.  相似文献   

2.
A laser velocimeter is described which uses an optical Doppler frequency discriminator in the form of a spherical mirror confocal Fabry-Perot interferometer (SFPI). The SFPI pass band is made to coincide with the laser frequency using a system of external control. Experimental results are given.  相似文献   

3.
A laser Doppler vibrometer (LDV) is described in which holographic optical elements are used to provide the interferometer reference and object illumination beams. A complementary metal-oxide semiconductor camera, incorporating a digital signal processor, is used to carry out real-time signal processing of the interferometer output to allow multipoint LDV to be implemented.  相似文献   

4.
光学纳米测量方法及发展趋势   总被引:14,自引:0,他引:14  
综述了光学方法中以频率跟踪方法、外差干涉仪、调频干涉仪、偏振干涉仪和光学光栅为代表的光学纳米测量方法。分析了它们的发展状况以及各自特点,指出建立适合于纳米测量的纳米环境是目前亟待解决的关键性问题,给出了光学纳米测量方法的发展方向和在设计测量系统时应该注意的问题  相似文献   

5.
应用光学双稳原理的高精度光纤传感器   总被引:3,自引:1,他引:2  
李淳飞  吴杰 《光学学报》1992,12(5):22-425
本文提出一种光纤干涉仪与光电混合光双稳装置相结合的新型光纤传感器.用光双稳开关脉冲计数度量温度变化,其测量精度比基于干涉条纹计数的一般干涉型光纤传感器的精度约高10~100倍,而且测量精度可调节.完成了这种传感器原理的模拟实验验证.  相似文献   

6.
Doppler optical coherence tomography (OCT) can image tissue structure and blood flow at micrometer-scale resolution but has limited imaging depth. We report a novel, linear-scanning, needle-based Doppler OCT system using angle-polished gradient-index or ball-lensed fibers. A prototype system with a 19-guage (diameter of approximately 0.9 mm) echogenic needle is constructed and demonstrates in vivo imaging of bidirectional blood flow in rat leg and abdominal cavity. To our knowledge, this is the first demonstration of Doppler OCT through a needle probe in interstitial applications to visualize deeply situated microcirculation.  相似文献   

7.
谭林秋  华灯鑫  汪丽  高飞  狄慧鸽 《物理学报》2014,63(22):224205-224205
相对于传统多普勒鉴频器Fabry-Perot干涉仪, Mach-Zehnder干涉仪(MZI)具有透过率高、直线条纹易于探测、可进行视场展宽等优点. 本文设计了基于条纹成像MZI的非相干多普勒测风激光雷达系统, 构建了风速反演的数学模型, 利用MZI视场展宽技术优化了激光雷达系统的性能. 数值仿真实现了MZI鉴频系统干涉条纹图样的理想输出, 采用SineSqr函数拟合法获取了高精度的多普勒频移前后干涉条纹的移动距离, 并通过视场补偿减小了入射角对MZI光程差的影响, 从而实现视场展宽. 结果表明: 采用SineSqr函数拟合法可获得在±100 m·s-1的径向风速范围内<0.45 m·s-1的风速误差, 克服了条纹重心法反演风速不稳定性的缺点; 视场展宽技术在不降低鉴频性能的情况下, 能最大补偿1°的视场角. MZI条纹成像多普勒激光雷达应用技术的探讨将为中高层大气风速激光雷达测量系统的实际开发奠定良好的基础. 关键词: 激光雷达 条纹成像Mach-Zehnder干涉仪 风速反演 视场补偿  相似文献   

8.
韩军  高波  张芳  高教波 《应用光学》2021,42(3):494-498
对于变间隙法布里-珀罗(F-P)干涉式成像光谱仪,空间干涉信息是否按光程差等间隔采样,即光程差与探测器像元位置之间是否是线性变化关系,直接决定了光谱数据处理的难易程度。经分析,变间隙法布里-珀罗干涉式光谱成像系统的光程差是干涉仪分光产生的两艾里斑的中心距离的函数,而两艾里斑中心距与探测器像元位置并非一直保持线性关系,与干涉仪楔角的取值有关。研究了不同楔角条件下光程差与探测器像元位置之间的关系曲线,结果表明,在任意楔角下,光程差与探测器阵列像元位置之间均保持良好的线性关系。长波红外变间隙F-P干涉式光谱成像系统与高精度光谱辐射计测得的特征峰位置重合度达100%。  相似文献   

9.
In this paper we present an electronic speckle pattern shearing interferometer using a photopolymer diffractive optical element in the form of a holographic grating, in combination with a ground glass to shear the images. The sheared images on the ground glass are further imaged onto a CCD camera. The distance between the grating and the ground glass can be used to control the shear and to vary the sensitivity of the system. The direction of sensitivity is easily controlled by rotation of the diffraction grating around its normal.Introducing photopolymer holographic gratings in ESPSI gives the advantage of using high aperture optical elements at relatively low cost. The fact that the diffractive optical element is a photopolymer layer on glass substrate with thickness of 2 mm makes for a compact optical system.The system was successfully used for detection of the resonant frequencies of a vibrating object.Most of the published work on vibration analysis is analytical. Very few experimental results are available in the literature. The well known laser Doppler vibrometers (LDV) and accelerometers used for modal analysis are pointwise measurement techniques, although multipoint LDV is available at significant cost.Electronic speckle pattern techniques suitable for experimental detection of the resonant frequencies of vibrating objects are very promising for vibration analysis because they are whole field and non-contact.A finite element model is developed for prediction of the vibration modes of the object under test. Detection of vibrational modes of aluminium diaphragm is demonstrated and compared with the theoretical model. The results obtained are very promising for future application of ESPSI systems with HOEs, for modal analysis. A significant advantage of shearography over electronic speckle pattern interferometry is that ESPSI is relatively insensitive to external disturbances. Another advantage of the proposed system is that it could be easily converted to a phase-shifting electronic speckle shearing interferometer.  相似文献   

10.
Optimal interferometer designs for optical coherence tomography   总被引:2,自引:0,他引:2  
Rollins AM  Izatt JA 《Optics letters》1999,24(21):1484-1486
We introduce a family of power-conserving fiber-optic interferometer designs for low-coherence reflectometry that use optical circulators, unbalanced couplers, and (or) balanced heterodyne detection. Simple design equations for optimization of the signal-to-noise ratio of the interferometers are expressed in terms of relevant signal and noise sources and measurable system parameters. We use the equations to evaluate the expected performance of the new configurations compared with that of the standard Michelson interferometer that is commonly used in optical coherence tomography (OCT) systems. The analysis indicates that improved sensitivity is expected for all the new interferometer designs, compared with the sensitivity of the standard OCT interferometer, under high-speed imaging conditions.  相似文献   

11.
GRIN透镜干涉仪光学系统模型和分析   总被引:1,自引:0,他引:1  
梁忠诚  杨震  明海  谢建平 《光学技术》2003,29(1):96-100
较完整地提出GRIN透镜干涉仪的数学模型,分析了光学系统处于六种不同模态下的特点,讨论了有关结构因素,特别是GRIN透镜长度对干涉仪工作性能的影响,有关分析和相关结论可作为GRIN透镜干涉仪系统设计和测量计算的依据。  相似文献   

12.
A compact high-resolution optical heterodyne interferometer combining a two-frequency light module and a minute optical system is described. The light module, which generates two independent frequencies of light, is fabricated by proton exchange method on LiNbO3 substrate. We report an experiment evaluating measurement accuracy using a micro-displacement measurement system which incorporates this interferometer. Results of the experiment with a standard thickness sample show high thermal stability with maximum measurement error of 1.8 nm at a temperature from 19°C to 33°C. The system was used to measure the hysteresis of a piezoelectric element for displacements of several nm, thereby making it possible to analyze the system quantitatively in practice.  相似文献   

13.
We describe a new and highly effective optical frequency discriminator and laser stabilization system based on signals reflected from a stable Fabry-Perot reference interferometer. High sensitivity for detection of resonance information is achieved by optical heterodyne detection with sidebands produced by rf phase modulation. Physical, optical, and electronic aspects of this discriminator/laser frequency stabilization system are considered in detail. We show that a high-speed domain exists in which the system responds to the phase (rather than frequency) change of the laser; thus with suitable design the servo loop bandwidth is not limited by the cavity response time. We report diagnostic experiments in which a dye laser and gas laser were independently locked to one stable cavity. Because of the precautions employed, the observed sub-100 Hz beat line width shows that the lasers were this stable. Applications of this system of laser stabilization include precision laser spectroscopy and interferometric gravity-wave detectors.  相似文献   

14.
Ren H  Sun T  MacDonald DJ  Cobb MJ  Li X 《Optics letters》2006,31(7):927-929
We present a moving-scatterer-sensitive optical Doppler tomography (MSS-ODT) technique for in vivo blood flow imaging in real time by using a spectral-domain optical coherence tomography system. In MSS-ODT the influence of stationary scatterers is suppressed by subtracting adjacent complex axial scans before calculating the Doppler frequency shift. We demonstrate that MSS-ODT is a useful technique for accurate determination of blood vessel size by imaging flow in a small capillary tube with a 75 microm inner diameter. The flow profile obtained with MSS-ODT yields a substantially more accurate tube diameter than that obtained with the conventional phase-resolved method, which underestimates the diameter by about 23%. We also demonstrate that MSS-ODT provides improved sensitivity over the conventional phase-resolved method for imaging in vivo blood flow in small vessels in a mouse ear.  相似文献   

15.
A new method based on the polarization interferometer structure has been applied to measure the optical admittance, the refractive index and thickness of a thin film. The structure is a vibration insensitive optical system. There is one Twyman-Green interferometer part to induce a phase difference and one Fizeau interferometer part to induce the interference in the system. The intensities coming from four different polarizers were measured at the same time to prevent mechanical vibration influence. Using the polarization interferometer, the optical admittance, the refractive index and thickness of a single layer of Ta2O5 thin film has been measured. The measurement results were compared with the results obtained by ellipsometer. The results meet reasonable values in both refractive index and thickness.  相似文献   

16.
A sensing system,with Michelson-type fiber optical interferometer based on single fiber Bragg grating (FBG) as the reflector,is demonstrated.The system used a frequency-matched ring fiber optical laser as the source.The closed Michelson-type fiber optical interferometer system will be helpful in simplifying the developed interferometric sensor by replacing the double reflectors with only one FBG reflecting the doubleside light.The basic sensing properties of the system are demonstrated,with a fiber optic piezoelectric ceramic transducer embedded in the arm of the interferometer simulating the sensing signal.  相似文献   

17.
Podoleanu A  Woods D 《Optics letters》2007,32(16):2300-2302
A power-efficient Fourier domain optical coherence tomography fiber system is presented free of mirror terms. The object and reference beams from the interferometer are spatially separated to illuminate different parts of the diffraction grating in the spectrometer according to a method inspired from the use of Talbot bands. In this way, the system is made sensitive to only one sign of the optical path difference in the interferometer.  相似文献   

18.
We describe a novel optical system for bidirectional color Doppler imaging of flow in biological tissues with micrometer-scale resolution and demonstrate its use for in vivo imaging of blood flow in an animal model. Our technique, color Doppler optical coherence tomography (CDOCT), performs spatially localized optical Doppler velocimetry by use of scanning low-coherence interferometry. CDOCT is an extension of optical coherence tomography (OCT), employing coherent signal-acquisition electronics and joint time-frequency analysis algorithms to perform flow imaging simultaneous with conventional OCT imaging. Cross-sectional maps of blood flow velocity with <50-microm spatial resolution and <0.6-mm/s velocity precision were obtained through intact skin in living hamster subdermal tissue. This technology has several potential medical applications.  相似文献   

19.
We present a fiber-based, low-coherence interferometer that significantly reduces phase noise by incorporating a second, narrowband, continuous-wave light source as a phase reference. By incorporating this interferometer into a Doppler OCT system, we demonstrate significant velocity noise reduction in reflective and scattering samples using processing techniques amenable to real-time implementation. We also demonstrate 90% suppression of velocity noise in a flow phantom.  相似文献   

20.
介绍了一个基于光学倍乘原理的绝对距离干涉测量系统。系统包括两个干涉仪:采用半导体激光器作为光源的定位干涉仪和测量位移的外差干涉仪。介绍了光源的选择,系统的设计以及信号的采集和处理方案。采用这套绝对测量系统,可以实现长度为2m以内的绝对距离测量,定位精度可以达到±0.5μm。  相似文献   