首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report a novel all-fiber narrow-bandwidth intermodal Mach–Zehnder interferometer (MZI) based on a long-period fiber grating (LPFG) combined with a fiber bitaper, and the MZI has no special limit for the resonant wavelength of the LPFG. Its responses to temperature and axial strain are studied theoretically and experimentally. Experimental results indicate that the temperature sensitivity is 0.0585 nm/°C within the temperature range from 30 °C to 90 °C and the axial strain sensitivity of 0.00013 nm/με can be neglected. Furthermore, as only the common single-mode fiber (SMF) is required during the fabrication process, the proposed device is cost effective and has good practicability in the optical sensing systems.  相似文献   

2.
Yage Zhan  Jun Luo  Hua Wu  Muhuo Yu 《Optik》2012,123(7):637-640
An all-fiber high resolution optical fiber grating concentration sensor has been studied theoretically and experimentally. A long period grating is used as the sensor head and a wavelength matched fiber Bragg grating is used as an interrogator to convert wavelength into intensity encoded information for interrogation. A concentration resolution of 0.104 g/L for NaCl solution is realized in experiment. The all-fiber sensor system, with the sensor head and the interrogator being all optical fiber components, is suitable for far-distance monitoring. The sensor system is with multifunction and can be used for temperature monitoring. A temperature resolution of 0.013 °C has realized in experiment.  相似文献   

3.
We report a temperature sensor based on a Bragg grating written in a benzil dimethyl ketal (BDK) doped multimode (MM) polymer optical fiber (POF) for the first time to our knowledge. The thermal response was further analyzed in view of theory and experiment. In theory, with the order of the reflected mode increasing from 1st to 60th order, for MM silica fiber Bragg grating (FBG) the temperature sensitivity will increase linearly from 16.2 pm/°C to 17.5 pm/°C, while for MM polymer FBG the temperature sensitivity (absolute value) will increase linearly from ?79.5 pm/°C to ?104.4 pm/°C. In addition, temperature sensitivity of MM polymer FBG exhibits almost 1 order larger mode order dependence than that of MM silica FBG. In experiment, the Bragg wavelength shift will decline linearly as the temperature rises, contrary to that of MM silica FBG. The temperature sensitivity of MM polymer FBG is ranged from ?0.097 nm/°C to ?0.111 nm/°C, more than 8 times that of MM silica FBG, showing great potential used as a temperature sensor.  相似文献   

4.
In this paper, two hybrid multimode/single mode fiber FabryPérot (FP) cavities were compared. The cavities fabricated by chemical etching are presented as high temperature and strain sensors. In order to produce this FP cavity a single mode fiber was spliced to a graded index multimode fiber with 62.5 μm core diameter. The FabryPérot cavities were tested as a high temperature sensor in the range between room temperature and 700 °C and as strain sensors. A reversible shift of the interferometric peaks with temperature allowed to estimate a sensitivity of 0.75 ± 0.03 pm/°C and 0.98 ± 0.04 pm/°C for the sensor A and B respectively. For strain measurement sensor A demonstrated a sensitivity of 1.85 ± 0.07 pm/μ? and sensor B showed a sensitivity of 3.14 ± 0.05 pm/μ?. The sensors demonstrated the feasibility of low cost fiber optic sensors for high temperature and strain.  相似文献   

5.
A novel method for simultaneous measurement of refractive index and temperature based on a small core and cladding diameters thinned fiber Mach–Zehnder interferometer (MZI) using singlemode-multimode-thinned-multimode-singlemode (SMTMS) fiber structure is proposed. Experiments indicate that the selected two interference orders have sensitivities of ?16.1936 nm/RIU and 0.0534 nm/°C, and ?23.0473 nm/RIU and 0.0575 nm/°C, respectively, among RI range from 1.3325–1.3720 and temperature range from 22 °C–82 °C. We can thus use the coefficient matrix of these two peaks to simultaneously determine the surrounding refractive index and temperature. The fabrication is easy, safe and cost effective, includes only the fusion splicing, making the device properly attractive for practical sensor applications.  相似文献   

6.
A high performance multiplexed fiber-optic sensor consisted of diaphragm-based extrinsic Fabry–Perot interferometer (DEFPI) and fiber Bragg grating (FBG) is proposed. The novel structure DEFPI fabricated with laser heating fusion technique possesses high sensitivity with 5.35 nm/kPa (36.89 nm/psi) and exhibits ultra-low temperature dependence with 0.015 nm/°C. But the ultra-low temperature dependence still results in small pressure measurement error of the DEFPI (0.0028 kPa/°C). The designed stainless epoxy-free packaging structure guarantees the FBG to be only sensitive to temperature. The temperature information is created to calibrate the DEFPI's pressure measurement error induced by the temperature dependence, realizing effectively temperature self-compensation of the multiplexed sensor. The sensitivity of the FBG is 10.5 pm/°C. In addition, the multiplexed sensor is also very easy to realize the pressure and the temperature high-precise high-sensitive simultaneous measurement at single point in many harsh environmental areas.  相似文献   

7.
We present large-area, edge-emitting, photonic-crystal (PC) distributed-feedback (DFB) quantum cascade lasers (QCLs) emitting at λ∼7.6 μm and operating up to a heat sink temperature of 80 °C. The lasers use the anticrossing of index- and Bragg-guided dispersions of rectangular lattice to control the optical mode in the wafer plane. Single-mode operation with a high signal-to-noise ratio of about 20 dB and narrow beam divergence of 6.2° was obtained. A high peak power of 630 mW at 20 °C and still more than 160 mW at 60 °C was observed. Such a high performance single-mode device is very important to expand the potential applications in the long-wave infrared range.  相似文献   

8.
《Radiation measurements》2009,44(2):158-162
Optical fibers have been proposed as dosimeters in both diagnostic and radiotherapy applications. A commercial germanium (Ge)-doped silica fiber with a 50 μm core diameter which showed good thermoluminescence (TL) properties was selected for this study. The radiation sources used were a high dose rate brachytherapy iridium-192, MV photon and MeV electron beams from a linear accelerator. The coating of the fiber was chemically removed and then annealed at 400 °C for 1 h prior to irradiation. After irradiation, the fiber was read on a Harshaw Model 3500 TLD reader. The optical fiber had one well-defined glow peak at 327 ± 2 °C at all the radiotherapy energies. The dose response was linear within the clinical relevant dose for all these energies. Reproducibility was mainly within 4–6% (one standard deviation) for high energy photons and electrons. The fiber was found to be energy independent within the MV photon energy range. At room temperature the fading up until 1 month was around 6% which was within the 6% uncertainty of the sensitivity calibration of the fiber. Re-using the fiber four times did not significantly alter the sensitivity factor. The optical fiber was found to be dose rate as well as angular independent. Central axis depth dose curves of both 10 MV photons and 12 MeV electrons using the fiber showed relatively good agreement to standard depth dose curves in water within 4%. The Ge-doped fiber is a promising TL dosimeter but improvements have to be made to reduce the reproducibility within 3% for high energy photons and electrons.  相似文献   

9.
B. Sardari  R. Asadi  K. Abbasian  A. Rostami 《Optik》2012,123(4):286-290
High-birefringence fiber loop mirrors (Hi-Bi FLM) are interested in a variety of applications such as temperature and strain sensors, but their serious limitation is their structure length, in the order of several meters, for application in optical integrated devices. In this paper, we have used electromagnetically induced transparency (EIT) phenomena to reduce the length of Hi-Bi FLM to below 50 μm, where 3-level nanocrystals (QDs) are doped in Hi-Bi FLM to realize EIT conditions. EIT phenomenon amplifies refractive index differences of slow and fast axes of Hi-Bi FLM, so that the length of FLM to obtain required phase difference is reduced. This proposed sensor can measure temperature and strain simultaneously with 62.5 pm/°C and 0.3 μm, respectively.  相似文献   

10.
We propose a hydrostatic pressure sensor based on a gold-coated thin-core fiber modal interferometer (TCFMI). A thin-core fiber is spliced to a single mode fiber forming a single-end fiber modal interferometer (FMI) due to the core mismatch and the fiber end reflection. Relative reflection spectra of TCFMIs based on thin-core fibers with different lengths are investigated. The TCFMI is gold-coated to enhance the optical reflectivity, which also results in the ripple of the relative reflection spectra of TCFMI. A high hydrostatic pressure sensor test system is proposed and the performance of the pressure sensor has been experimentally investigated. A pure-ripple-shift measurement method is used to achieve the demodulation of the sensor. The proposed pressure sensor has a sensing range up to 40 MPa and a sensitivity of 44.8 pm/MPa.  相似文献   

11.
In this work, a self-heating type optical fiber flowmeter with high sensitivity was proposed. The core-offset fiber structures were employed to couple a part of signal light into the fiber cladding layer, and the other part of light still propagated in the core layer. The intermodal interference between the two parts of light happened when the cladding modes were coupled back into core layer. Meanwhile, the high power laser was also introduced into fiber to heat the silver film coated on the surface of the cladding layer. When the cool gas flow passed, the temperature of the sensor probe decreased due to the heat transfer process. Because of the thermo-optic effect in the fiber, interference spectrum could be shifted when the temperature was changed. The experimental results showed the resolution of the proposed sensor was 2×10−2 m/s in the region of 0–8 m/s. The highest sensitivity could achieve 1537 pm/(m/s).  相似文献   

12.
In this work, an advanced multifunctional optical switch based on multimode fibers is proposed. It can work as a 3 × 1 optical multiplexer/combiner, a 2 × 2 optical switch, a variable optical attenuator and a variable optical power splitter. All these functionalities can be developed in the same device without any hardware modification, only by using the proper ports and control electronics.The proposed switch has been developed for being used in the visible and near infrared wavelength range: 450–650 nm for optical fiber automobile applications, 650–850 nm for home broadband applications; and 850–1300 nm for multimode fiber access networks. Up to three different types of twisted nematic liquid crystal cells have been designed and fabricated for fulfilling these different wavelength ranges as part of the proposed device.The multifunctional switch has been implemented and experimentally tested. Crosstalk usually better than ? 15 dB at 532 nm, 660 nm and 850 nm, in any state has been measured. Switching is achieved at voltage levels of 4 Vrms. Fiber to fiber insertion losses when operating as a 2 × 2 optical switch, range from 10 to 15 dB within 200 nm wavelength range; with a non-optimized optics for collimation and coupling.  相似文献   

13.
We propose and demonstrate a fiber in-line Mach–Zehnder interferometer using thin-core fibers. This in-line interferometer is composed of a short section of thin-core fiber inserted between two single mode fibers (SMF), and demonstrated as a strain and temperature sensor in this study. A strain sensitivity of ?1.83 pm/με with a measurement range of 0?2000 με, and the temperature sensitivity of ?72.89 pm/°C with a temperature variation of 50 °C are achieved. We also discussed that the influence of strain and temperature change on the relative power ratios among the excited cladding modes in thin-core fibers.  相似文献   

14.
We fabricated an electronically controlled polymer optical fiber cleaver, which uses a razor-blade guillotine and provides independent control of fiber temperature, blade temperature, and cleaving speed. To determine the optimum cleaving conditions of microstructured polymer optical fibers (mPOFs) with hexagonal hole structures we developed a program for cleaving quality optimization, which reads in a microscope image of the fiber end-facet and determines the core-shift and the statistics of the hole diameter, hole-to-hole pitch, hole ellipticity, and direction of major ellipse axis. For 125 μm in diameter mPOFs of the standard polymer PMMA we found the optimum temperatures to be 77.5 °C for both blade and fiber. For 280 μm in diameter mPOFs of the humidity insensitive polymer TOPAS® (grade 8007) the optimum temperature was 40° for both blade and fiber. A 100 μm thick flat-edge blade was found to minimize the core-shift by the cleaving to only 298 nm or 5% of the pitch for the PMMA mPOF at the optimal temperature.  相似文献   

15.
We propose a refractometric sensor based on micro/nanofiber Bragg grating (MNFBG). The refractive index (RI) sensing performance dependence on the fiber radius and Bragg grating period of the sensor, as well as the temperature cross-sensitive effect, is investigated theoretically. The simulation results demonstrate that 400 nm-radius MNFBG has a linear response to RI ranging from 1.3 to 1.39 with a sensitivity as high as 992.7 nm/RIU and half temperature cross-sensitivity of normal FBG. A maximum sensitivity of up to 1200 nm/RIU and an outstanding RI resolution of 8.3 × 10-6 can be achieved. MNFBG has high potential in various types of optical fiber sensor applications.  相似文献   

16.
《Current Applied Physics》2010,10(2):487-497
An infrared diagnosis device provides two-dimensional images and patient-oriented results that can be easily understood by the inspection target by using infrared cameras. However, this device has disadvantages such as large size, high price, and inconvenient maintenance. In this regard, this study has proposed a small diagnosis device for body heat using a single infrared sensor and implementing an infrared detection system using a single infrared sensor and an algorithm that represents thermography using the obtained data on the temperature of the point source. The developed system had a temperature resolution of 0.1 °C and reproducibility of ±0.1 °C. The accuracy was 90.39% at the error bound of ±0 °C and 99.98% at that of ±0.1 °C. To evaluate the proposed algorithm and system, the infrared images of the camera method were compared. To verify the device’s clinical applicability, thermal images with clinical meaning were obtained from a patient who had lesions.  相似文献   

17.
The performance of a simple sensor system prepared using gold (Au)-deposited glass rods of 1 to 4 mm in diameter with a deposition length of 100 mm based on surface plasmon resonance (SPR) is presented. The sensor properties of the Au-deposited glass rods of 2 mm in diameter with deposition lengths of 10 to 100 mm are also presented. The sensor system consists of a light-emitting diode (LED) as the light source and a photodiode (PD) as the detector. The response curves and sensor properties of the Au-deposited glass rod with a Au film thickness of 45 nm obtained by using three LEDs with yellowish green (563 nm), red (660 nm), and infrared (940 nm) emissions were investigated. The results were compared with those of a corresponding Au-deposited optical fiber sensor with a core diameter of 0.2 mm. Though the sensitivity, response, and detection limit of the Au-deposited glass rod sensor are lower than those of the optical fiber sensor, the fabrication and handling of the Au-deposited glass rod sensor are easier because of the robustness. Since the dielectric constant of Au changes with the light wavelength, the sensor properties of both the Au-deposited glass rod sensor and the optical fiber sensor depend strongly on the wavelength of the incident light and can be controlled by changing the LED emission wavelength. This sensor system is a new SPR-based refractometer with easy construction and operation. Ethanol concentrations in various spirits were measured with this SPR-based refractometer and the results agreed well with those measured with an Abbe refractometer.  相似文献   

18.
A novel curvature sensor based on optical fiber Mach–Zehnder interferometer (MZI) is demonstrated. It consists of two spherical-shape structures and a long-period grating (LPG) in between. The experimental results show that the shift of the dip wavelength is almost linearly proportional to the change of curvature, and the curvature sensitivity are −22.144 nm/m−1 in the measurement range of 5.33–6.93 m−1, −28.225 nm/m−1 in the range of 6.93–8.43 m and −15.68 nm/m−1 in the range of 8.43–9.43 m−1, respectively. And the maximum curvature error caused by temperature is only −0.003 m−1/°C. The sensor exhibits the advantages of all-fiber structure, high mechanical strength, high curvature sensitivity and large measurement scales.  相似文献   

19.
Filter-free ultra-wideband (UWB) doublet pulse generation is experimentally demonstrated in the optical domain based on cross-gain modulation (XGM) in semiconductor optical amplifier (SOA) and UWB-over-fiber technology is implemented by exploiting dispersion-induced pulse broadening effect in single-mode fiber (SMF). In our proposed system, the SOA generates a polarity-inversed Gaussian pulse train with respect to the injected one through the XGM. After a piece of SMF, the bandwidth of polarity-reversed Gaussian pulse broadens due to the induced dispersion. After the combination of the two light waves with a suitable time delay between them, UWB pulse is obtained. The key parameters for UWB pulse, including central frequency, 10 dB bandwidth, as well as fractional bandwidth are experimentally obtained with 8 GHz, 9.9 GHz and 123% respectively. The generated UWB doublet pulse conforms with the UWB definition of Federal Communications Commission (FCC).  相似文献   

20.
The influence of temperature on optical measurements has been studied for determining fat and protein contents in complex food systems. A model system consisting of mixtures of fat, protein, water and emulsion was developed to create an imitation of complex food systems. The changes in optical properties of the system from 25 °C to 40 °C were measured in the wavelength from 1100 nm to 1670 nm. Irregular changes as a whole were founded and therefore a statistical method was needed to correct the temperature effect. A method called global robust temperature calibration model is proposed and the correction effect was validated. The results indicated that it can significantly reduce the temperature effect on optical measurement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号