首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Summary.  A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of iodide. The method is based on the catalytic effect of iodide on the reaction of triflupromazine (TFP) with H2O2. The reaction is followed spectrophotometrically by tracing the oxidation product at 498 nm within 1 min after addition of H2O2. The optimum reaction conditions are TFP (0.4 × 10−3 M), H2SO4 (1.0M), H3PO4 (2.0M), and H2O2 (1.6M) at 30°C. Following this procedure, iodide can be determined with a linear calibration graph up to 4.5 ng ċ cm−3 and a detection limit of 0.04 ng ċ cm−3, based on the 3 Sb criterion. The method can also be applied to the determination of iodate and periodate ions. Determination of as little as 0.2, 1.0, 2.0, and 4.0 ng ċ cm−3 of I, IO3 -, or IO4 - in aqueous solutions gave an average recovery of 98% with relative standard deviations below 1.6% (n = 5). The method was applied to the determination of iodide in Nile river water and ground waters as well as in various food samples after alkaline ashing treatment. The method is compared with other catalytic spectrophotometric procedures for iodide determination. Received January 19, 2001. Accepted (revised) March 12, 2001  相似文献   

2.
Summary.  A highly selective, sensitive, and simple catalytic method for the determination of molybdenum in natural and waste waters was developed. It is based on the catalytic effect of Mo(VI) on the oxidation of 2-aminophenol with H2O2. The reaction is monitored spectrophotometrically by tracing the oxidation product at 430 nm after 10 min of mixing the reagents. Addition of 800 μg · cm−3 EDTA conferred high selectivity; however, interfering effects of Au(III), Cr(III), Cr(VI), and Fe(III) had to be eliminated by a reduction and co-precipitation procedure with SnCl2 and Al(OH)3. Mo(VI) shows a linear calibration graph up to 11.0 ng · cm−3; the detection limit, based on the 3S b-criterion, is 0.10 ng · cm−3. The unique selectivity and sensitivity of the new method allowed its direct application to the determination of Mo(VI) in natural and waste waters. Received April 11, 2001. Accepted (revised) June 18, 2001  相似文献   

3.
 In the present work, rutin (3,3′ ,4′ ,5,7-pentahydrohyflavone-3-rhamnoglucoside) was determinated via a complexing reaction with a titanyloxalate anion. K2[TiO(C2O4)2] and rutin react in 50% ethanol forming a 1:2 complex in a pH range from 4.00 to 11.50, in which the TiO(C2O4)2 2− ion is linked to rutin through the 4-carbonyl and 5-hydroxyl group. The thermodynamic stability constant log β2 0 of the complex is determined to 10.80 at pH = 6.50. The change of the standard Gibbs free energy Δ G0 amounts to −61 kJċ mol−1, indicating that the process of complex formation is spontaneous. The optimal conditions for the spectrophotometric determination of microconcentrations of rutin are at pH=6.40 and λ= 430 nm, where the complex shows an absorption maximum with a molar absorption coefficient a 430=(60±2)ċ103 dm3ċ mol−1ċ cm−1. The method is applied rutin determination from tablets.  相似文献   

4.
Summary.  In the present work, rutin (3,3′ ,4′ ,5,7-pentahydrohyflavone-3-rhamnoglucoside) was determinated via a complexing reaction with a titanyloxalate anion. K2[TiO(C2O4)2] and rutin react in 50% ethanol forming a 1:2 complex in a pH range from 4.00 to 11.50, in which the TiO(C2O4)2 2− ion is linked to rutin through the 4-carbonyl and 5-hydroxyl group. The thermodynamic stability constant log β2 0 of the complex is determined to 10.80 at pH = 6.50. The change of the standard Gibbs free energy Δ G0 amounts to −61 kJċ mol−1, indicating that the process of complex formation is spontaneous. The optimal conditions for the spectrophotometric determination of microconcentrations of rutin are at pH=6.40 and λ= 430 nm, where the complex shows an absorption maximum with a molar absorption coefficient a 430=(60±2)ċ103 dm3ċ mol−1ċ cm−1. The method is applied rutin determination from tablets. Received January 4, 2000. Accepted (revised) February 17, 2000  相似文献   

5.
A new spectrofluorimetric method was developed for the determination of trace amounts of coenzyme A (CoA). In the presence of periodic acid (H5IO6), CoA can remarkably enhance the fluorescence intensity of the Tb3+–ciprofloxacin (CIP) complex at 545 nm in a buffer solution at pH 5.4; the enhanced fluorescence intensity of the Tb3+ ion is proportional to the concentration of CoA. The optimal conditions for the determination of CoA were also investigated. The linear range and the detection limit for the determination of CoA were 6.08 × 10−6–1.64 × 10−5 and 2.1 × 10−8 mol L−1, respectively. This method is simple, practical and relatively free of interference from coexisting substances, and can be successfully applied to assess CoA in injection and biological samples. Moreover, the enhancement mechanism of the fluorescence intensity of the CoA–Tb3+–CIP system in the presence of H5IO6 is also discussed.  相似文献   

6.
A new H2O2 biosensor was fabricated on the basis of nanocomposite films of hemoglobin (Hb), silver nanoparticles (AgNPs), and multiwalled carbon nanotubes (MWNTs)–chitosan (Chit) dispersed solution immobilized on glassy carbon electrode (GCE). The immobilized Hb displayed a pair of well-defined and reversible redox peaks with a formal potential (E θ′) of −22.5 mV in 0.1 M pH 7.0 phosphate buffer solution. The apparent heterogeneous electron transfer rate constants (k s) in the Chit–MWNTs film was evaluated as 2.58 s−1 according to Laviron’s equation. The surface concentration (Γ*) of the electroactive Hb in the Chit–MWNTs film was estimated to be (2.48 ± 0.25) × 10−9 mol cm−2. Meanwhile, the Chit–MWNTs/Hb/AgNPs/GCE demonstrated excellently electrocatalytical ability to H2O2. Its apparent Michaelis–Menten constant (K Mapp) for H2O2 was 0.0032 mM, showing a good affinity. Under optimal conditions, the biosensors could be used for the determination of H2O2 ranging from 6.25 × 10−6 to 9.30 × 10−5 mol L−1 with a detection limit of 3.47 × 10−7 mol L−1 (S/N = 3). Furthermore, the biosensor possessed rapid response to H2O2 and good stability, selectivity, and reproducibility.  相似文献   

7.
 Microwave digestion reduction-aeration and pyrolysis combined with cold vapour atomic absorption and cold vapour atomic fluorescence are compared for the determination of total mercury in several biological and environmental matrices. The biological samples were digested in a mixture of HNO3/H2O2, the environmental samples in a mixture of HNO3/HClO4. After reduction with SnCl2, the mercury was collected by two-stage gold amalgamation. After microwave digestion reduction-aeration, detection limits of 1.4 ng g−1 and 0.6 ng g−1 were obtained for cold vapour atomic absorption spectrometry (CVAAS) and cold vapour atomic fluorescence spectrometry (CVAFS), respectively, for 250 mg of environmental samples. For biological samples (500 mg) the detection limits were 0.7 ng g−1 (CVAAS) and 0.4 ng g−1 (CVAFS). After pyrolysis, detection limits of 3.5 ng g−1 and 1.6 ng g−1 for CVAAS and CVAFS, respectively, were obtained for a 10 mg sample. Pyrolysis can only be applied when the organic content of the sample is not too high. Accurate results were obtained for 8 certified reference materials of both environmental and biological origin. In addition, a real sludge sample was analysed. Author for correspondence. E-mail: richard.dams@rug.ac.be Received September 18, 2002; accepted December 3, 2002 Published online May 5, 2003  相似文献   

8.
Sensitive fluorescent probes for the determination of hydrogen peroxide and glucose were developed by immobilizing enzyme horseradish peroxidase (HRP) on Fe3O4/SiO2 magnetic core–shell nanoparticles in the presence of glutaraldehyde. Besides its excellent catalytic activity, the immobilized enzyme could be easily and completely recovered by a magnetic separation, and the recovered HRP-immobilized Fe3O4/SiO2 nanoparticles were able to be used repeatedly as catalysts without deactivation. The HRP-immobilized nanoparticles were able to activate hydrogen peroxide (H2O2), which oxidized non-fluorescent 3-(4-hydroxyphenyl)propionic acid to a fluorescent product with an emission maximum at 409 nm. Under optimized conditions, a linear calibration curve was obtained over the H2O2 concentrations ranging from 5.0 × 10−9 to 1.0 × 10−5 mol L−1, with a detection limit of 2.1 × 10−9 mol L−1. By simultaneously using glucose oxidase and HRP-immobilized Fe3O4/SiO2 nanoparticles, a sensitive and selective analytical method for the glucose detection was established. The fluorescence intensity of the product responded well linearly to glucose concentration in the range from 5.0 × 10−8 to 5.0 × 10−5 mol L−1 with a detection limit of 1.8 × 10−8 mol L−1. The proposed method was successfully applied for the determination of glucose in human serum sample.  相似文献   

9.
 The kinetics of the CrO(O2)2 formation by H2O2 and Cr2O7 2− in aqueous acidic media was measured at 293 ± 2 K in a pH range between 2.5 and 3.3. Using the stopped-flow method with rapid scan UV-VIS detection, the rate law of the formation of CrO(O2)2 was determined. For the media HClO4, HNO3 and CH3COOH, the reaction order in the Cr2O7 2− concentration was found to be 0.5. For [H2O2] as well as for [H+], the reaction was first order in all acids used. In HCl and H2SO4 media the reaction was first order in Cr2O7 2−. At T = 293 ± 2 K the rate constant for the formation of Cr(O)(O2)2 was found to be (7.3 ± 1.9) · 102 M−3/2 s−1 in HClO4.  相似文献   

10.
We report quantitative infrared spectra of vapor-phase hydrogen peroxide (H2O2) with all spectra pressure-broadened to atmospheric pressure. The data were generated by injecting a concentrated solution (83%) of H2O2 into a gently heated disseminator and diluting it with pure N2 carrier gas. The water vapor lines were quantitatively subtracted from the resulting spectra to yield the spectrum of pure H2O2. The results for the ν6 band strength (including hot bands) compare favorably with the results of Klee et al. (J Mol. Spectrosc. 195:154, 1999) as well as with the HITRAN values. The present results are 433 and 467 cm-2 atm−1 (±8 and ±3% as measured at 298 and 323 K, respectively, and reduced to 296 K) for the band strength, matching well the value reported by Klee et al. (S = 467 cm−2 atm−1 at 296 K) for the integrated band. The ν1 + ν5 near-infrared band between 6,900 and 7,200 cm−1 has an integrated intensity S = 26.3 cm−2 atm−1, larger than previously reported values. Other infrared and near-infrared bands and their potential for atmospheric monitoring are discussed.  相似文献   

11.
Summary.  The kinetics of the CrO(O2)2 formation by H2O2 and Cr2O7 2− in aqueous acidic media was measured at 293 ± 2 K in a pH range between 2.5 and 3.3. Using the stopped-flow method with rapid scan UV-VIS detection, the rate law of the formation of CrO(O2)2 was determined. For the media HClO4, HNO3 and CH3COOH, the reaction order in the Cr2O7 2− concentration was found to be 0.5. For [H2O2] as well as for [H+], the reaction was first order in all acids used. In HCl and H2SO4 media the reaction was first order in Cr2O7 2−. At T = 293 ± 2 K the rate constant for the formation of Cr(O)(O2)2 was found to be (7.3 ± 1.9) · 102 M−3/2 s−1 in HClO4. Corresponding author. E-mail: grampp@ptc.tu-graz.ac.at Received January 30, 2002; accepted (revised) June 5, 2002  相似文献   

12.
It is observed that Ag(I) catalyzes the rate of substitution of phenylhydrazine (PhNHNH2) into hexacyanoferrate(II), producing a cherry red colored complex, [Fe(CN)5PhNHNH2]3−. The reaction was monitored at 488 nm leading to the formation of the complex under the conditions: [Fe(CN)6]4− (5.0 × 10−3 mol dm−3), PhNHNH2 (2.0 × 10−3 mol dm−3), temperature (25 ± 0.1 °C), pH (2.8 ± 0.02), and ionic strength, I (0.02 mol dm−3), (KNO3). Under optimum conditions, absorbance at fixed times (A t ) is linearly related to Ag(I) in the concentration range 10.79–97.08 ng cm−3, in the presence of several diverse ions. The highest percentage error and relative standard deviations in the entire range of Ag(I) determination are found to be 2.5% and 0.16, with a detection limit of 8.75 ng cm−3 of silver(I). The experimental accuracies expressed in terms of percentage recoveries are in the range of 97.87–102.50. The method was successfully applied for the determination of Ag(I) in a few synthetic samples and found to be in good agreement with those obtained from atomic absorption spectrophotometry (AAS). The validity of the proposed method has also been tested for Ag(I) determination in spiked drinking water samples. The present catalytic kinetic method (CKM) is highly sensitive, selective, reproducible, and inexpensive. A review of recently published catalytic spectrophotometric methods for determination of Ag(I) has also been presented for comparison.  相似文献   

13.
A method to fabricate poly(3,4-ethylene dioxythiophene)-poly(4-styrene sulfonate)-Meldola Blue (PEDOT-PSS-MDB)-modified electrodes had been disclosed. Firstly, the PEDOT-PSS-film-modified electrode was electrochemically prepared. Then, the PEDOT-PSS was treated as a matrix to immobilize electroactive mediator, Meldola Blue (MDB), by means of an electrostatic interaction to form the proposed film, PEDOT-PSS-MDB. Electrochemical properties of the proposed film exhibited surface confinement and pH dependence. The PEDOT-PSS-MDB electrode could electrocatalytically reduce hydrogen peroxide (H2O2) with a low overpotential and showed a linear response to H2O2 in the concentration range of 5 to 120 μM, detection limit of 0.1 μM, and sensitivity of 353.9 μA mM−1 cm−2 (S/N = 3). By comparison, the electrocatalytic activity of PEDOT-PSS-MDB electrode was found superior to that of PEDOT-PSS and MDB-PSS electrodes. It also has competitive potential as compared with other mediators, through the use of HRP to determine H2O2. Moreover, the potential interferents such as ascorbic acid, dopamine, uric acid, and glucose were also studied for H2O2 determination by the proposed film.  相似文献   

14.
The polarographic behavior of thiamethoxam (a neonicotinoid insecticide) was studied by direct current and differential pulse polarography. Depending on the pH thiamethoxam exhibited one or two well-defined cathodic polarographic waves. The characteristics of the electrode reaction were investigated and it was found that at pH > 5.0 the target molecule captures four electrons in the first step, and two in the second. Based on the reduction behavior of the target molecule on the mercury electrode, a differential pulse polarographic method was elaborated for the rapid determination of thiamethoxam at pH 8.0. With the optimized method, a linear response for thiamethoxam was found in the concentration range of 31.1 − 470 ng cm−3, the relative standard deviation did not exceed 1.6%, and the detection and quantitation limits were found to be 9.3 ng cm−3 and 31.1 ng cm−3, respectively. The method was applied to the determination of thiamethoxam in commercial formulations and real samples (potato and maize). The procedure is simple, fast, sensitive, and compares well with comparative spectrophotometric and chromatographic (HPLC/DAD) methods.  相似文献   

15.
The chemiluminescence (CL) of peracetic acid (PAA) in alkaline medium is very weak but is strongly enhanced after the addition of dihydralazine sulfate (DHZS). Based on this phenomenon, a simple, rapid and highly sensitive flow-injection CL method for the determination of DHZS was developed. The CL emission was linearly related to the DHZS concentration in the range of 20–4000 ng mL−1 with a detection limit (3σ) of 1.2 ng mL−1. As a preliminary application, the proposed method was successfully applied to the determination of DHZS in pharmaceutical preparations; the recovery of DHZS in human urine was between 96.5% and 102.2%. A detailed CL mechanism was proposed and singlet molecular oxygen (1O2) was suggested to be produced in the CL reaction process.  相似文献   

16.
Human flavin-containing monooxygenases are the second most important class of drug-metabolizing enzymes after cytochromes P450. Here we report a simple but functional and stable enzyme-electrode system based on a glassy carbon (GC) electrode with human flavin-containing monooxygenase isoform 3 (hFMO3) entrapped in a gel cross-linked with bovine serum albumin (BSA) by glutaraldehyde. The enzymatic electrochemical responsiveness is characterised by using well-known substrates: trimethylamine (TMA), ammonia (NH3), triethylamine (TEA), and benzydamine (BZD). The apparent Michaelis–Menten constant (KM) and apparent maximum current (Imax) are calculated by fitting the current signal to the Michaelis–Menten equation for each substrate. The enzyme-electrode has good characteristics: the calculated sensitivity was 40.9 ± 0.5 mA mol−1 L cm−2 for TMA, 43.3 ± 0.1 mA mol−1 L cm−2 for NH3, 45.2 ± 2.2 mA mol−1 L cm−2 for TEA, and 39.3 ± 0.6 mA mol−1 L cm−2 for BZD. The stability was constant for 3 days and the inter-electrode reproducibility was 12.5%. This is a novel electrochemical tool that can be used to investigate new potential drugs against the catalytic activity of hFMO3.  相似文献   

17.
Nano-Al2O3 was doped in poly(acrylonitrile-co-methyl methacrylate) (P(AN-co-MMA)), and polyethylene(PE)-supported P(AN-co-MMA)/nano-Al2O3 microporous composite polymer electrolyte (MCPE) was prepared. The performances of the prepared MCPE for lithium ion battery use, including ionic conductivity, electrochemical stability, interfacial compatibility, and cyclic stability, were studied by scanning electron spectroscopy, linear sweep voltammetry, and electrochemical impedance spectroscopy. It is found that the nano-Al2O3 significantly affects the MCPE performances. Compared to the MCPE without any nano-Al2O3, the MCPE with 10 wt.% nano-Al2O3 reaches its best performances. Its ionic conductivity is improved from 2.0 × 10−3 to 3.2 × 10−3 S cm−1, its decomposition potential is enhanced from 5.5 to 5.7 V (vs Li/Li+), and its interfacial resistance on lithium is reduced from 520 to 160 Ω cm2. Thus, the battery performance is improved.  相似文献   

18.
This paper describes the use of an aluminum electrode plated by metallic palladium and modified by Prussian blue (PB/Pd-Al) in the electrocatalytic reduction of hydrogen peroxide (H2O2). The effect of pH on the electroreduction of H2O2 on the modified electrode is investigated and a simple irreversible reduction pathway is suggested. The electroreduction kinetics including transfer coefficient α, potential-dependent charge transfer rate constants k f, and diffusion coefficient D are estimated by means of forced hydrodynamic voltammetry using a rotating disk PB/Pd-Al electrode. The mean values obtained for kinetics are 0.38, 10−2 cm−1, and 7.6 × 10−6 cm2 s−1, respectively. The long-term stability of the modifying layers on the Al substrate was studied.  相似文献   

19.
Summary.  Oxo peroxo glycolato complexes of vanadium(V) (M 2[V2O2(O2)2(C2H2O3)2nH2O (n=0, 1; M=NBu4 + (1), K+ (2), NH4 + (3), Cs+ (4), NPr4 + (5)) as well as (NBu4)2[V2O4(C2H2O3)2]ċ H2O (6) have been prepared and characterized by spectroscopic methods. X-Ray structure analysis of 1 revealed the presence of dinuclear [V2O2(O2)2(C2H2O3)2]2− anions with a (chemical structure) bridging core and six coordinated vanadium(V) atoms in a distorted pentagonal pyramidal array. Received July 12, 1999. Accepted (revised) October 28, 1999  相似文献   

20.
 Oxo peroxo glycolato complexes of vanadium(V) (M 2[V2O2(O2)2(C2H2O3)2nH2O (n=0, 1; M=NBu4 + (1), K+ (2), NH4 + (3), Cs+ (4), NPr4 + (5)) as well as (NBu4)2[V2O4(C2H2O3)2]ċ H2O (6) have been prepared and characterized by spectroscopic methods. X-Ray structure analysis of 1 revealed the presence of dinuclear [V2O2(O2)2(C2H2O3)2]2− anions with a (chemical structure) bridging core and six coordinated vanadium(V) atoms in a distorted pentagonal pyramidal array.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号