首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ABSTRACT

The influence of silanised silica fume addition on the pore size distribution and wettability of white cement paste was investigated using T1–T2 correlation nuclear magnetic resonance (NMR) relaxometry. Surface silanisation of silica fume particles was achieved by the hydrolysis reaction of APTES (3-Aminopropyltriethoxysilane) and condensation of the silanol functional groups on the surface. The methods used for characterisation of the silanised silica fume particles were scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR) and thermogravimetric analysis (TGA). By adding silanised silica fume to the cement paste, the accessibility of water molecules to the porous system becomes restricted, leading to a lower permeability in comparison with the unmodified cement paste. Differential scanning calorimetry (DSC) measurements on the cement pastes saturated with Octamethylcyclotetrasiloxane confirm also that the size of inter-C–S–H and capillary pores is not influenced by the addition of silica fume in a detectable manner.  相似文献   

2.
T2* measurements in human brain at 1.5, 3 and 7 T   总被引:1,自引:0,他引:1  
Measurements have been carried out in six subjects at magnetic fields of 1.5, 3 and 7 T, with the aim of characterizing the variation of T2* with field strength in human brain. Accurate measurement of T2* in the presence of macroscopic magnetic field inhomogeneity is problematic due to signal decay resulting from through-slice dephasing. The approach employed here allowed the signal decay due to through-slice dephasing to be characterized and removed from data, thus facilitating an accurate measurement of T2* even at ultrahigh field. Using double inversion recovery turbo spin-echo images for tissue classification, an analysis of T2* relaxation times in cortical grey matter and white matter was carried out, along with an evaluation of the variation of T2* with field strength in the caudate nucleus and putamen. The results show an approximately linear increase in relaxation rate R2* with field strength for all tissues, leading to a greater range of relaxation times across tissue types at 7 T that can be exploited in high-resolution T2*-weighted imaging.  相似文献   

3.
Water protons T1 and T2 relaxation times in samples of whole blood, obtained from healthy people and from patients affected by Macrocytic Anemia on one side and Lymphatic and Myeloid Leukemia on the other, have been measured with the FT NMR technique at 80 Mhz and at 25 °C. No significant difference with respect to the value of the spin lattice relaxation time parameter measured for the healthy control group is experimentally evident in the case of the Macrocytic Anaemia while the spin spin relaxation time increases in magnitude. On the reverse both the leukemic cases present a significant (p < 0.001) increase in the relaxation times with respect to the control group. The experimental relaxation data belonging to the anaemic case show a linear correlation with the red cells volume while that obtained for the two leukaemic cases appear linearly correlated with the total white cell numbers. From the relaxation data an estimate of the amount of water tightly bound to the white cells membrane can be determined which results roughly thirty times lower than that bound to the red cells membrane. In this work is also presented a step by step outline of the water relaxation behavior which starts with the pure water and ends with the water in the whole blood supported by relaxation experiments done on the isolated blood main components.  相似文献   

4.
Assuming dipole-dipole interaction as the dominant relaxation mechanism of protons of water molecules adsorbed onto macromolecule (biopolymer) surfaces we have been able to model the dependences of relaxation rates on temperature and frequency. For adsorbed water molecules the correlation times are of the order of 10(-5)s, for which the dispersion region of spin-lattice relaxation rates in the rotating frame R(1)(ρ)=1/T(1)(ρ) appears over a range of easily accessible B(1) values. Measurements of T(1)(ρ) at constant temperature and different B(1) values then give the "dispersion profiles" for biopolymers. Fitting a theoretical relaxation model to these profiles allows for the estimation of correlation times. This way of obtaining the correlation time is easier and faster than approaches involving measurements of the temperature dependence of R(1)=1/T(1). The T(1)(ρ) dispersion approach, as a tool for molecular dynamics study, has been demonstrated for several hydrated biopolymer systems including crystalline cellulose, starch of different origins (potato, corn, oat, wheat), paper (modern, old) and lyophilized proteins (albumin, lysozyme).  相似文献   

5.
A 48-echo pulse sequence with five different echo-spacing combinations was examined to determine how one can most effectively measure the T2 relaxation characteristics of cerebral tissue containing a long T2 component. For each scan, the first 32 echoes had an echo spacing of 10 ms, while the spacing for Echoes 33-48 (DeltaTE2) was 10, 20, 30, 40 or 50 ms. In an in vivo study using 10 normal volunteers, it was found that the resolution of T2 distribution peaks for both myelin water (approximately 20 ms) and intracellular/extracellular (IE) water (approximately 80 ms) improved as DeltaTE2 increased. The geometric mean T2 values of the main peak agreed within the error for all DeltaTE2 values. A phantom study simulated T2 relaxation distributions that are expected in the brains of patients with demyelinating diseases. For phantoms in which the T2 values of the IE and lesion (200-500 ms) water compartments were separated by at least a factor of 3, each compartment in the distribution was better resolved when DeltaTE2=40 or 50 ms. On the basis of these results, we recommend the use of extended DeltaTE2 values for imaging patients with lesions, without the risk of losing valuable short T2 information.  相似文献   

6.
The development of a 3-D, multi-nuclear continuous wave NMR imaging (CW-NMRI) system is described and its imaging capability is demonstrated on a range of materials exhibiting extremely short T(2) relaxation values. A variety of radiofrequency resonators were constructed and incorporated into a new gradient and field offset coil assembly, while the overall system design was modified to minimise microphonic noise which was present in an earlier prototype system. The chemically combined (27)Al in a high temperature refractory cement was imaged, and the CW-NMRI system was found to be sensitive to small differences in (27)Al content in these samples. The penetration of (23)Na in salt water into samples of ordinary Portland cement (OPC) was investigated, with enhanced uptake observed for samples with larger pore size distributions. The solid (13)C component in a carbonated cement sample was also imaged, as were the (7)Li nuclei in a sample of powdered Li(2)CO(3). A spatial resolution of 1mm was measured in an image of a rigid polymeric material exhibiting a principal T( *)(2) value of 16.3 micros. Finally, a high-resolution 3-D image of this rigid polymer is presented.  相似文献   

7.
The interstitial water content typically increases in the early degeneration of articular cartilage. Previously, T2 relaxation has been related to water content, yet it is known to be strongly affected by the collagen orientation. Articular cartilage plugs from the bovine patella, femur and tibia (N=20) were mapped for T1 and T2 at 9.4 T to test the ability of T1 relaxation to reflect cartilage water content. As a reference, water and proteoglycan (PG) contents were determined. Significant (P<.01) linear associations were demonstrated between the relaxation rates and tissue water content (R1: r=−.81, R2: r=−.60) and PG content (R1: r=.75). After adjustment for the tissue water content, partial correlation analysis did not show significant associations between the relaxation rates and tissue PG content. After the effect of PGs was removed, significant (P<.05) linear correlation between the relaxation rates and tissue water content (R1: r=−.48, R2: r=−.50) was observed. Thus, the spin-lattice relaxation rate is proposed to provide a biomarker for water content in articular cartilage.  相似文献   

8.
Multiecho T2 relaxation measurements to determine geometric mean T2 (GMT2) and myelin water fraction (MWF) are lengthy, resulting in increased motion artefacts from patient discomfort and reduced patient compliance. The goal of this study was to shorten the acquisition time for multiecho T2 measurements without affecting T1 weighting by varying TR across k-space. Six phantoms and 10 healthy volunteers were imaged with both a constant TR and a variable TR multiecho T2 sequence. T1 weighting was determined by TR at the center of k-space; for variable TR measurement, TR was shortened linearly from the center to the edges of k-space. Phantoms showed excellent agreement for proton density and GMT2 between constant and variable TR measurements. No significant differences were found in proton density or MWF for any of the brain structures between the two measurements. The average GMT2 over all structures between the two experiments was not significantly different. In summary, with the variable TR approach, scan time was reduced by >20%, with minimal loss of image resolution and no significant affect on proton density, MWF or GMT2.  相似文献   

9.

Objective

T2 mapping has been used widely in detecting cartilage degeneration in osteoarthritis. Several scanning sequences have been developed in the determination of T2 relaxation times of tissues. However, the derivation of these times may vary from sequence to sequence. This study seeks to evaluate the sequence-dependent differences in T2 quantitation of cartilage, muscle, fat and bone marrow in the knee joint at 3 T.

Methods

Three commercial phantoms and 10 healthy volunteers were studied using 3 T MR. T2 relaxation times of the phantoms, cartilage, muscle, subcutaneous fat and marrow were derived using spin echo (SE), multiecho SE (MESE), fast SE (FSE) with varying echo train length (ETL), spiral and spoiler gradient (SPGR) sequences. The differences between these times were then evaluated using Student's t test. In addition, the signal-to-noise ratio (SNR) efficiency and coefficient of variation of T2 from each sequence were calculated.

Results

The average T2 relaxation time was 36.38±5.76 ms in cartilage and 34.08±6.55 ms in muscle, ranging from 27 to 45 ms in both tissues. The times for subcutaneous fat and marrow were longer and more varying, ranging from 41 to 143 ms and from 42 to 160 ms, respectively. In FSE acquisition, relaxation time significantly increases as ETL increases (P<.05). In cartilage, the SE acquisition yields the lowest T2 values (27.52±3.10 ms), which is significantly lower than those obtained from other sequences (P<.002). T2 values obtained from spiral acquisition (38.27±6.45 ms) were higher than those obtained from MESE (34.35±5.62 ms) and SPGR acquisition (31.64±4.53 ms). These differences, however, were not significant (P>.05).

Conclusion

T2 quantification can be a valuable tool for the diagnosis of degenerative disease. Several different sequences exist to quantify the relaxation times of tissues. Sequences range in scan time, SNR efficiency, reproducibility and two- or three-dimensional mapping. However, when choosing a sequence for quantitation, it is important to realize that several factors affect the measured T2 relaxation time.  相似文献   

10.
The objective was to measure the effect of 100% oxygen inhalation on T1 relaxation times in skeletal muscle. Healthy volunteers were scanned using three different MRI protocols while breathing medical air and 100% oxygen. Measurements of T1 were made from regions of interest (ROIs) within various skeletal muscle groups. Dynamic data of subjects breathing a sequence of air-oxygen-air allowed the calculation of characteristic wash-in and -out times for dissolved oxygen in muscle. Contrary to previous findings, a statistically significant decrease in T1 in skeletal muscle was observed due to oxygen inhalation. We report approximate baseline characteristic values for the response of skeletal muscle to oxygen inhalation. This measurement may provide new biomarkers for evaluation of oxygen delivery and consumption in normal and diseased skeletal muscle.  相似文献   

11.
Depth and orientational dependencies of microscopic magnetic resonance imaging (MRI) T(2) and T(1ρ) sensitivities were studied in native and trypsin-degraded articular cartilage before and after being soaked in 1 mM Gd-DTPA(2-) solution. When the cartilage surface was perpendicular to B(0), a typical laminar appearance was visible in T(2)-weighted images but not in T(1ρ)-weighted images, especially when the spin-lock field was high (2 kHz). At the magic angle (55°) orientation, neither T(2)- nor T(1ρ)-weighted image had a laminar appearance. Trypsin degradation caused a depth- and orientational-dependent T(2) increase (4%-64%) and a more uniform T(1ρ) increase at a sufficiently high spin-lock field (55%-81%). The presence of the Gd ions caused both T(2) and T(1ρ) to decrease significantly in the degraded tissue (6%-38% and 44%-49%, respectively) but less notably in the native tissue (5%-10% and 16%-28%, respectively). A quantity Sensitivity was introduced that combined both the percentage change and the absolute change in the relaxation analysis. An MRI experimental protocol based on two T(1ρ) measurements (without and with the presence of the Gd ions) was proposed to be a new imaging marker for cartilage degradation.  相似文献   

12.
This study investigated the feasibility of an MRI protocol providing whole-body T2* maps at 1.5 T. Seven healthy volunteers (mean age=30.1+/-3.7, three women and four men) and two patients (both male, 53 and 46 years old) affected by transfusion-dependent anemias participated in the study. Coronally oriented images of five subsequent body levels were acquired using a fat-suppressed multiecho 2D gradient-echo sequence (12 echo times ranging from 4.8 to 76.3 ms were selected) and afterwards composed. Parametrical T2* maps of the whole body were reconstructed on a pixel-by-pixel basis. For both, healthy volunteers and patients, representative T2* values were computed from extended regions of interest (ROIs). Good-quality whole-body T2* maps were computed in all volunteers and patients. In healthy volunteers, T2* values were assessed in the cerebral white (58.5+/-4.2 ms) and gray (81.4+/-5.5 ms) matter, liver (34.3+/-7.0 ms), spleen (63.5+/-3.3 ms), kidneys (65.4+/-10.3 ms) and skeletal muscles (~30 ms). The liver presented faster relaxation rates in males as compared to females. One patient (serum ferritin concentration=927 microg/dl) showed shortened T2* values in liver (3.6+/-5.5 ms), spleen (3.1+/-4.8 ms), kidneys (11.1+/-7.1 ms) and muscles (25.1+/-3.4 ms). The second patient (serum ferritin concentration=346 microg/dl) presented reduced T2* values in liver (3.9+/-7.3 ms), spleen (20.1+/-9.8 ms) and kidneys (24.6+/-7.7 ms). The presented technique may find clinical application in the assessment of the iron burden in the entire body, and in monitoring of chelation therapies in patients treated with frequent blood transfusions.  相似文献   

13.
A prototype continuous wave MRI system operating at 7T has been used successfully to study a variety of heterogeneous materials exhibiting T2 relaxation values ranging from 10 micros to 50 ms. Two-dimensional images of a poly(methly methacrylate) (PMMA) resolution phantom (T2=38 micros) exhibited a spatial resolution of approximately 1mm at a magnetic field gradient strength of 200 mT/m. The technique was used to study the hydration, drying, and subsequent water penetration properties of cement samples made from ordinary Portland cement, and revealed inhomogeneities arising from the cure conditions. Sandstone samples from an oil reservoir in the North Sea were also studied; structure within these materials, arising from the sedimentary bed layering in the reservoir, was found to have an effect on their water transport properties. A section from a confectionery bar (T2* approximately 50-60 ms) was also imaged, and its internal structure could be clearly discerned.  相似文献   

14.
The purpose of this study was to investigate the effects of biophysical factors on the diffusion and the relaxation time T(2) independently. Certain properties of the extracellular and the intracellular space may change radically in pathological conditions resulting in water diffusion changes. A tissue model consisting of red blood cells was studied. The extra- and intracellular spaces were modified osmotically and by suspending medium concentration. Diffusion measurements were evaluated with regard to the effective medium theory. Neither the nature of the protein in the extracellular space nor an increased level of intracellular hydration caused a significant net water diffusion change in the cell suspension. The relaxation time T(2) exhibited very little dependence on the extracellular volume fraction or the concentration or the nature of the protein in the extracellular space. An increased level of intracellular hydration resulted in systematically larger T(2) values. It seems probable that increases in extracellular protein concentrations or in the extent of intracellular hydration do not play a significant role in the diffusion changes detected in pathological conditions. T(2) appears to depend on the level of hydration or the total water content but is seemingly less dependent of the concentration and the nature of the extracellular protein in our model solutions.  相似文献   

15.
Proton nuclear magnetic resonance (NMR) spin-spin relaxation and imaging have been applied to investigate white Portland cement pastes during hydration in the absence and in the presence of organic solvents. The main organic solvent investigated was methanol, alone or together with the organic waste 2-chloroaniline (2-CA), an aromatic amine representative of an important class of highly toxic compounds. For all the analysed samples, prepared with a solvent-to-cement ratio of 0.4, the decay of the echo magnetization has been fitted by adopting a model that combines an exponential component with a gaussian one. The calculated independent relaxation parameters have been discussed in terms of morphological and dynamical changes that occur during the cement hardening process and pore formation. Three kinds of water molecules: "solid-like" (chemically and physically bound), "liquid-like" (porous trapped) and "free" water, endowed with anisotropic, near isotropic and isotropic motion, respectively, were identified. Spin-echo images collected on the same samples during the hydration kinetics, allowed the changes of water and solvents spatial distribution in the porous network to be monitored, showing percolation phenomena and confirming the multimodal open channels structure of the hardened cement system. Both T(2) relaxation and imaging data indicated that a pronounced delay occurs in the cement hardening when organics are present.  相似文献   

16.
NMR relaxation time distributions of water (1)H obtained by a portable single-sided surface device have been compared with MRI internal images obtained with a laboratory imaging apparatus on the same biocalcarenite (Lecce Stone) samples during capillary water uptake. The aim of this work was to check the ability of NMR methods to quantitatively follow the absorption phenomenon under different wettability conditions of the internal pore surfaces. Stone wettability changes were obtained by capillary absorption of a chloroform solution of Paraloid PB72, a hydrophobic acrylic resin frequently used to protect monuments and buildings, through one face of each sample. Both relaxation and imaging data have been found in good quantitative agreement each other and with masses of water determined by weighing the samples. In particular the Washburn model of water capillary rise applied to the imaging data allowed us to quantify the sorptivity in both treated and untreated samples. Combining relaxation and imaging data, a synergetic improvement of our understanding of the water absorption kinetics at both pore and sample scales is obtained. Since relaxation data have been taken over the course of time without interrupting the absorption process, simply by keeping the portable device on the surface opposite to the absorption, the results show that the single-sided NMR technique is a powerful tool for in situ evaluation of water-repellent treatments frequently used for consolidation and/or protection of stone artifacts.  相似文献   

17.
Fast, high-resolution, longitudinal relaxation time (T1) mapping is invaluable in clinical and research applications. It has been shown that two spoiled gradient recalled echo (SPGR) images acquired in steady state with variable flip angles is an attractive alternative to the multi-image sets previously acquired with inversion or saturation recovery. The known sensitivity of the two-point method to transmit radiofrequency field (B1) inhomogeneity exacerbated at 3 T and above, however, mandates its combination with an additional, time-consuming and possibly specific-absorption-rate-intensive B1 measurement, preventing direct migration of the method to these fields. To address this, we introduce a method designed to be free of systematic errors caused by B1 inhomogeneity in which the value of T1 is extracted from three SPGR images acquired with echo planar imaging (EPI) readout. The precision of the T1 maps produced is found to be comparable to the two-point method, while the accuracy is greatly improved in the same time and spatial resolution. A welcome byproduct of the method is a map of B1 that can be used to correct other acquisitions in the same session. Tables of the optimal acquisition protocols are provided for several total imaging times.  相似文献   

18.
Microstructure and texture of cementitious porous materials   总被引:1,自引:0,他引:1  
We have characterized the microstructure of different cementitious materials (white and Portland cement pastes, mortars, concretes) by different magnetic resonance techniques. In particular, we show how the measurement of proton nuclear magnetic spin-lattice relaxation as a function of magnetic field strength (and hence nuclear Larmor frequency) can provide reliable information on the dynamics of proton species at the surface of CSH, the specific surface area and the pore size distribution throughout the progressive hydration of cement-based materials. The measurement does not require any drying temperature modification and is sufficiently fast to be applied continuously during the progressive hydration of the material. Coupling this method with the standard proton nuclear spin relaxation and high-resolution NMR allows us to follow the development of microscale texture within the material.  相似文献   

19.
We discuss a simple approach to enhance sensitivity for (13)C high-resolution solid-state NMR for proteins in microcrystals by reducing (1)H T(1) relaxation times with paramagnetic relaxation reagents. It was shown that (1)H T(1) values can be reduced from 0.4-0.8s to 60-70 ms for ubiquitin and lysozyme in D(2)O in the presence of 10 mM Cu(II)Na(2)EDTA without substantial degradation of the resolution in (13)C CPMAS spectra. Faster signal accumulation using the shorter (1)H T(1) attained by paramagnetic doping provided sensitivity enhancements of 1.4-2.9 for these proteins, reducing the experimental time for a given signal-to-noise ratio by a factor of 2.0-8.4. This approach presented here is likely to be applicable to various other proteins in order to enhance sensitivity in (13)C high-resolution solid-state NMR spectroscopy.  相似文献   

20.
Several single-scan experiments for the measurement of the longitudinal relaxation time (T1) are proposed. These experiments result in fast and accurate determinations of the relaxation rate, are relatively robust to pulse imperfections, and preserve information about the chemical shift. The method used in these experiments is to first encode the T1 values as a spatial variation of the magnetization and then to read out this variation either by applying a weak gradient during acquisition or by sequentially observing different slices of the sample. As a result, it is possible to reduce the time necessary to determine the T1 values by one or two orders of magnitude. This time saving comes at the expense of the signal-to-noise level of the resulting spectrum and some chemical shift resolution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号