1.
To reduce the size and the weight of heat exchangers, vortex generators (VGs) were punched on fin surface to improve the fin heat transfer performance. This paper is focused on the optimal fin spacing for three-row flat tube bank fin mounted with VGs. The results show, for commonly used fin materials and fin thickness, the optimal fin spacing is about 2 mm in industrial application for the configuration of tube bank fin studied.  相似文献   

2.
This paper presents results of the experimental study conducted on heated horizontal rectangular fin array under natural convection. The temperature mapping and the prediction of the flow patterns over the fin array with variable fin spacing is carried out. Dimensionless fin spacing to height (S/H) ratio is varied from 0.05 to 0.3 and length to height ratio (L/H) = 5 is kept constant. The heater input to the fin array assembly is varied from 25 to 100 W. The single chimney flow pattern is observed from 8 to 12 mm fin spacing. The end flow is choked below 6 mm fin spacing. The single chimney flow pattern changes to sliding or end flow choking at 6 mm fin spacing. The average heat transfer coefficient (ha) is very small (2.52–5.78 W/m2 K) at 100 W for S = 5–12 mm. The ha is very small (1.12–1.8 W/m2 K) at 100 W for 2–4 mm fin spacing due to choked fin array end condition. The end flow is not sufficient to reach up to central portion of fin array and in the middle portion there is an unsteady down and up flow pattern resulting in sliding chimney. The central bottom portion of fin array channel does not contribute much in heat dissipation for S = 2–4 mm. The ha has significantly improved at higher spacing as compared to lower spacing region. The single chimney flow pattern is preferred from heat transfer point of view. The optimum spacing is confirmed in the range of 8–10 mm. The average heat transfer results are compared with previous literature and showed similar trend and satisfactory agreement. An empirical equation has been proposed to correlate the average Nusselt number as a function of Grashof number and fin spacing to height ratio. The average error for this equation is ?0.32 %.  相似文献   

3.
In the present study, the potential of rectangular fins with 30° and 90° angle and 10 mm offset from the horizontal direction for heat transfer enhancement in a plate fin heat exchanger is numerically evaluated with conjugated heat transfer approach. The rectangular fins are mounted on the flat plate channel. The numerical computations are performed by solving a steady, three-dimensional Navier–Stokes equation and an energy equation by using Fluent software program. Air is taken as working fluid. The study is carried out at Re = 400 and inlet temperatures, velocities of cold and hot air are fixed as 300, 600 K and 1.338, 0.69 m/s, respectively. Colburn factor j versus Re design data is presented by using Fluent. The results show that the heat transfer is increased by 10 % at the exit of channel with fin angle of 30° when compared to channel without fin for counter flow. The heat transfer enhancement with fins of 30° and 90° for different values of Reynolds number with 300, 500 and 800 and for varying fin heights, fin intervals and also temperature distributions of fluids on the top and bottom surface of the channel are investigated for parallel and counter flow.  相似文献   

4.
The steady-state natural convection heat transfer from aluminum vertical rectangular fins extending perpendicularly from vertical rectangular base was investigated experimentally. Thirty different fin configurations were tested. Experiments were performed for fin lengths of 250 and 340 mm. Fin thickness was kept fixed at 3 mm. Fin height and fin spacing were varied from 5 to 25 mm and 5.75 to 85.5 mm, respectively. Five heat inputs ranging from 25 to 125 W were supplied for all fin configurations, hence; the base-to-ambient temperature differences were measured in order to evaluate the heat transfer rates from fin arrays. The results of experiments have shown that the convective heat transfer rate from fin arrays depends on geometric parameters and base-to-ambient temperature difference. The separate roles of fin height, fin spacing and base-to-ambient temperature difference were investigated. It was found that, for a given base-to-ambient temperature difference, the convective heat transfer rate from fin arrays takes on a maximum value as a function of fin spacing and fin height and an optimum fin spacing value which maximizes the convective heat transfer rate from the fin array is available for every fin height. These measurements were to extend data obtained earlier from aluminum fin-arrays using the same experimental system and method (Yüncü and Güvenç in Heat Mass Transfer 37:409–416, 2001). Data collated from earlier and present work cover the range of fin spacing from 4.5 to 85.5 mm. The fin length range was from 100 to 340 mm, the fin height from 5 to 25 mm and the number of fins per array 3 to 34. The range of base-to-ambient temperature difference was quite extensive, from 30 to 150 K. These results indicate that the optimum fin spacing is between 6.1 and 11.9 mm, for the fin arrays employed in the earlier and present work. A scale analysis is performed in order to estimate the order-of-magnitude of optimum fin spacing at a given fin length and base-to-ambient temperature difference. From the scale analysis, correlations to evaluate the optimum fin spacing value and the corresponding maximum convective heat transfer rate at a given fin length and base-to-ambient temperature difference were obtained.  相似文献   

5.
In this paper, the semi-dimpled slit fin is proposed and the characteristics of heat transfer and fluid flow are analyzed based on the orthogonal experiment design method. A serial studies on the effects of fin pitch, arrangement of semi-dimple, dimple radius on heat transfer and flow characteristics of semi-dimpled slit fin are investigated. The computational results show fin pitch (Fp) has significantly effected on the performance of heat transfer and fluid flow, the influence of arrangement of semi-dimple, the dimple radius (R) and the opening direction of semi-dimples dwindle. At the same time, compared to the general semi-dimpled slit fin, the heat transfer coefficient and JF factors of the optimized fin increase by 10.7–25.1 and 2.6–7.7 %, respectively. When Re ≤ 1,521, the overall performance of slit fin is better than that of optimized fin; while Re > 1,521, the overall performance of optimized fin is better than that of slit fin. Finally, the performance evaluation plot of enhanced heat transfer of heat exchanger is applied to analyze the optimized fin, it can be seen that optimization fin have better heat transfer performance under the same power consumption.  相似文献   

6.
Tube bank fin heat exchanger is one of the most compact heat exchangers, and it is widely used in industry equipments. The flat tube bank fin heat exchangers with vortex generators (VGs) have significant good heat transfer performance, and are used as radiators of locomotive. Here, we study heat transfer enhancement of a new fin where VGs are mounted on both surfaces of the fin. The heat transfer performance of this pattern is evaluated by a numerical method, and the results are compared with those obtained, under identical mass flow rate, when the VGs are mounted only on one surface of the fin. The results reveal that using this new pattern the height of VGs can be reduced and still obtain satisfactory heat transfer enhancement, while the pressure drop is reduced. The results also reveal that if VGs on one surface of the fin is determined, the locations where VGs are mounted on other surface of the same fin are very important, with configurations studied in this paper, depending on the value of Reynolds number, there exists an optimum location with which best heat transfer performance can be obtained.  相似文献   

7.
The results obtained from naphthalene sublimation heat/mass analogy experiments in selecting the optimum geometrical parameters of tube bank fin heat exchanger with fins mounted with vortex generators are compared with the results obtained from the condensing experiments of the real heat exchangers with vortex generators punched out on the fins. The results declare that VGs pouched or mounted on fin surfaces have only limited effects on heat transfer performance in the studied configurations; naphthalene sublimation method can be used to select fin patterns with reasonable reliability.  相似文献   

8.
This paper presents a new predictive model of droplet flow and heat transfer from molten salt droplets in a direct contact heat exchanger. The process is designed to recover heat from molten CuCl in a thermochemical copper–chlorine (Cu–Cl) cycle of hydrogen production. This heat recovery occurs through the physical interaction between high temperature CuCl droplets and air. Convective heat transfer between droplets and air is analyzed in a counter-current spray flow heat exchanger. Numerical results for the variations of temperature, velocity and heat transfer rate are presented for two cases of CuCl flow. The optimal dimensions of the heat exchanger are found to be a diameter of 0.13 m, with a height of 0.6 and 0.8 m, for 1 and 0.5 mm droplet diameters, respectively. Additional results are presented and discussed for the heat transfer effectiveness and droplet solidification during heat recovery from the molten CuCl droplets.  相似文献   

9.
In the present study, a whole heat exchanger with a hydraulic diameter of 2.3 mm is tested, which is a minichannel heat exchanger according to the Kandlikar classification. This is a louvered fin and flat tube heat exchanger currently used in car cooling systems, also known as radiator. A glycol-water mixture (60/40 in volume) circulates through the tubes at flows ranging from 100 to 7800 l/h and at a supply temperature of 90 °C. This fluid is cooled with ambient air at a temperature of 20 °C and at frontal air velocities varying between 0.5 and 7 m/s. The thermohydraulic performance of the heat exchanger is compared with the classical correlations given in the literature for the heat transfer and the friction factor calculation. On the glycol-water side the heat exchanger is characterized for Reynolds numbers from 30 to 8000. A first comparison is carried out with the correlations available in the literature with a purely predictive model by obtaining a predictive value with a systematic under prediction lower than 10%. In a second step a semi-empirical model is considered to identify the experimental heat transfer coefficients for this application.  相似文献   

10.
The fin efficiency in a heat exchanger element that is a simplification of one row in a tube-and-fin heat exchanger was theoretically examined within wide ranges of the affecting variables: the conventional fin efficiency and the isothermal effectiveness of the heat exchanger. These variables are suggested for use also in the further studies. An analytical solution can be found for the case of a constant heat transfer coefficient. The ambient temperature variation alone decreases the fin efficiency less than 4%. The local heat transfer coefficient obtained from the numerical fluid flow simulations is strongly affected by the fin properties because the thermal boundary conditions for the fluid flow changes. On a poorly conducting fin surface the heat transfer coefficient in front of the fin base is much larger than on an isothermal fin because the heat flux is increasing in the flow direction. At low fin efficiencies this compensates for the decrease in fin efficiency due to ambient temperature variation.  相似文献   

11.
In the present study, the heat transfer characteristics in dry surface conditions of a new type of heat exchanger, namely a helically coiled finned tube heat exchanger, is experimentally investigated. The test section, which is a helically coiled fined tube heat exchanger, consists of a shell and a helical coil unit. The helical coil unit consists of four concentric helically coiled tubes of different diameters. Each tube is constructed by bending straight copper tube into a helical coil. Aluminium crimped spiral fins with thickness of 0.5 mm and outer diameter of 28.25 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Ambient air is used as a working fluid in the shell side while hot water is used for the tube-side. The test runs are done at air mass flow rates ranging between 0.04 and 0.13 kg/s. The water mass flow rates are between 0.2 and 0.4 kg/s. The water temperatures are between 40 and 50°C. The effects of the inlet conditions of both working fluids flowing through the heat exchanger on the heat transfer coefficients are discussed. The air-side heat transfer coefficient presented in term of the Colburn J factor is proportional to inlet-water temperature and water mass flow rate. The heat exchanger effectiveness tends to increase with increasing water mass flow rate and also slightly increases with increasing inlet water temperature.  相似文献   

12.
In this work, we present the numerical results of the average heat transfer coefficients, $ \overline{{h_{\varphi } }} $ , over a circular plane fin in a finned-tube bundle for both aligned and staggered arrangements as well as the fin efficiency and the heat flux dissipated from the whole fin. The study covers a wide range of Reynolds number (2 × 103–3 × 104), for three different positions of the finned tube inside the heat exchanger. The temperature distribution on the fins surfaces was obtained experimentally using infrared thermography technique. The predicted values of the heat transfer coefficient were obtained numerically using the finite element method in conjunction with the conjugate gradient algorithm and the measured temperatures.  相似文献   

13.
Three dimensional numerical studies were performed for laminar heat transfer and fluid flow characteristics of wavy fin heat exchangers with elliptic/circular tubes by body-fitted coordinates system. The simulation results of circular tube were compared with the experiment data, then circular and elliptic (e = b/a = 0.6) arrangements with the same minimum flow cross-sectional area were compared. A max relative heat transfer gain of up to 30% is observed in the elliptic arrangement, and corresponding friction factor only increased by about 10%. The effects of five factors on wavy fin and elliptic tube heat exchangers were examined: Reynolds number (based on the smaller ellipse axis, 500  4000), eccentricity (b/a, 0.6  1.0), fin pitch (Fp/2b, 0.05  0.4), fin thickness (Ft/2b, 0.006  0.04) and tube spanwise pitch (S1/2b, 1.0  2.0). The results show that with the increasing of Reynolds number and fin thickness, decreasing of the eccentricity and spanwise tube pitch, the heat transfer of the finned tube bank are enhanced with some penalty in pressure drop. There is an optimum fin pitch (Fp/2b = 0.1) for heat transfer, but friction factor always decreases with increase of fin pitch. And when Fp/2b is larger than 0.25, it has little effects on heat transfer and pressure drop. The results were also analyzed from the view point of field synergy principle. It was found that the effects of the five factors on the heat transfer performance can be well described by the field synergy principle.  相似文献   

14.
Air-side heat transfer and friction characteristics of five kinds of fin-and-tube heat exchangers, with the number of tube rows (N = 12) and the diameter of tubes (Do = 18 mm), have been experimentally investigated. The test samples consist of five types of fin configurations: crimped spiral fin, plain fin, slit fin, fin with delta-wing longitudinal vortex generators (VGs) and mixed fin with front 6-row vortex-generator fin and rear 6-row slit fin. The heat transfer and friction factor correlations for different types of heat exchangers were obtained with the Reynolds numbers ranging from 4000 to 10000. It was found that crimped spiral fin provides higher heat transfer and pressure drop than the other four fins. The air-side performance of heat exchangers with the above five fins has been evaluated under three sets of criteria and it was shown that the heat exchanger with mixed fin (front vortex-generator fin and rear slit fin) has better performance than that with fin with delta-wing vortex generators, and the slit fin offers best heat transfer performance at high Reynolds numbers. Based on the correlations of numerical data, Genetic Algorithm optimization was carried out, and the optimization results indicated that the increase of VG attack angle or length, or decrease of VG height may enhance the performance of vortex-generator fin. The heat transfer performances for optimized vortex-generator fin and slit fin at hand have been compared with numerical method.  相似文献   

15.
In the present study, the effects of fin thickness on the heat transfer and friction characteristics of fin-and-tube heat exchangers having herringbone wavy fin configuration are experimentally investigated. The experimental apparatus consists essentially of a well insulated open wind tunnel and herringbone wavy fin-and-tube heat exchangers made from aluminium plate finned, copper tube. Air and water are used to be working fluids in air-side and tube-side, respectively. A total of 10 samples of the fin-and-tube heat exchangers are tested. The experimental procedures are conducted by keeping the inlet water temperature at a pre-selected value, adjusting the water volumetric flow rate at a specific value and varying the air velocity. The results are presented as plots of the Colburn factor and friction factor against the Reynolds number based on the fin collar outside diameter (ReDc). From the results, it is found that for number of tube rows (N) = 2, the Colburn factor increases with increasing fin thickness. For N 4, the Colburn factor decreases with increasing fin thickness when ReDc < 1800, and increases with increasing fin thickness when ReDc > 2500. The friction factor increases with increasing fin thickness when fin pitch (Fp) 1.81 mm.  相似文献   

16.
A combination of uniform-thickness annular fins evenly spaced on a tube is a common extended-surface heat exchanger configuration. An analytical model is developed and is verified by comparing total heat transfer predicted by the model to available experimental data. A direct-pattern search technique is applied to the model to optimize the fin/ tube geometry. Optimum dimensions and spacing of fins are established to provide the maximum free convection heat transfer from a fin/tube combination. The optimum arrangement is dependent on fin thermal conductivity, tube diameter, volume of fin material per unit length of tube, and temperature difference between the tube and the surrounding air. Calculated results indicate that a fin in the optimum fin/tube system is shorter and thicker than an isolated fin optimized for minimum material (with no consideration of the effects of fin spacing).  相似文献   

17.
The thermal contact resistance is a principal parameter interfering with heat transfer in a fin–tube heat exchanger. However, the thermal contact resistance in the interface between tubes and fins has not been clearly investigated. The objective of the present study is to examine the thermal contact conductance for various fin–tube heat exchangers with tube diameter of 9.52 mm and to find a correlation between the thermal contact conductance and effective factors such as expansion ratio, fin type, fin spacing and hydrophilic coating. In this study, experiments have been conducted only to measure heat transfer rate between hot and cold water. To minimize heat loss to the ambient air by the natural convection fin–tube heat exchangers have been placed in an insulated vacuum chamber. Also, a numerical scheme has been employed to calculate the thermal contact conductance with the experimental data. As a result, a new correlation including the influences of expansion ratio, slit of fin and fin coating has been introduced, and the portion of each thermal resistance has been estimated in the fin–tube heat exchangers with 9.52 mm tube.  相似文献   

18.
An experimental investigation of flow boiling heat transfer in a commercially available microfin tube with 9.52 mm outer diameter has been carried out. The microfin tube is made of copper with a total fin number of 55 and a helix angle of 15°. The fin height is 0.24 mm and the inner tube diameter at fin root is 8.95 mm. The test tube is 1 m long and is electrically heated. The experiments have been performed at saturation temperatures between 0 and −20°C. The mass flux was varied between 25 and 150 kg/m2s, the heat flux from 15,000 W/m2 down to 1,000 W/m2. All measurements have been performed at constant inlet vapour quality ranging from 0.1 to 0.7. The measured heat transfer coefficients range from 1,300 to 15,700 W/m2K for R134a and from 912 to 11,451 W/m2K for R404A. The mean heat transfer coefficient of R134a is in average 1.5 times higher than for R404A. The mean heat transfer coefficient has been compared with the correlations by Koyama et al. and by Kandlikar. The deviations are within ±30% and ±15%, respectively. The influence of the mass flux on the heat transfer is most significant between 25 and 62.5 kg/m2s, where the flow pattern changes from stratified wavy flow to almost annular flow. This flow pattern transition is shifted to lower mass fluxes for the microfin tube compared to the smooth tube.  相似文献   

19.
In this study, experimental and simulation studies of the evaporation heat transfer coefficient and pressure drop of R-134a flowing through corrugated tubes are conducted. The test section is a horizontal counter-flow concentric tube-in-tube heat exchanger 2.0 m in length. A smooth tube and corrugated tubes with inner diameters of 8.7 mm are used as the inner tube. The outer tube is made from a smooth copper tube with an inner diameter of 21.2 mm. The corrugation pitches used in this study are 5.08, 6.35, and 8.46 mm. Similarly, the corrugation depths are 1, 1.25, and 1.5 mm, respectively. The results show that the maximum heat transfer coefficient and pressure drop obtained from the corrugated tube are up to 22 and 19 % higher than those obtained from the smooth tube, respectively. In addition, the average difference of the heat transfer coefficient and pressure drop between the simulation model and experimental data are about 10 and 15 %, respectively.  相似文献   

20.
Three-dimensional laminar fluid flow and heat transfer over a four-row plate-fin and tube heat exchanger with electrohydrodynamic (EHD) wire electrodes are studied numerically. The effects of different electrode arrangements (square and diagonal), tube pitch arrangements (in-line and staggered) and applied voltage (VE=0–16 kV) are investigated in detail for the Reynolds number range (based on the fin spacing and frontal velocity) ranging from 100 to 1,000. It is found that the EHD enhancement is more effective for lower Re and higher applied voltage. The case of staggered tube pitch with square wire electrode arrangement gives the best heat transfer augmentation. For VE=16 kV and Re = 100, this study identifies a maximum improvement of 218% in the average Nusselt number and a reduction in fin area of 56% as compared that without EHD enhancement.  相似文献   