首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wang CC  Chiou SS  Wu SM 《Electrophoresis》2005,26(13):2637-2642
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE.  相似文献   

2.
Kuo CY  Chiou SS  Wu SM 《Electrophoresis》2006,27(14):2905-2909
This paper describes approaches for large-volume sample stacking (LVSS) with an EOF pumpin CE for the determination of methotrexate (MTX) and its metabolites in human plasma. After pretreatment of plasma through a SPE cartridge, a large sample volume was loaded by hydrodynamic injection (3 psi, 70 s) into the capillary filled with phosphate buffer (70 mM, pH 6.0) containing 0.01% polyethylene oxide. Following removal of a large plug of sample matrix from the capillary using polarity switching (-25 kV), the separation of anionic analytes was subsequently performed without changing polarity again, achieving an improvement of sensitivity of around a 100-fold. The method was applied to therapeutic drug monitoring of MTX in one acute lymphoblastic leukemia patient. This study is one of very few applications showing the feasibility of LVSS in analysis of biological samples by CE.  相似文献   

3.
A simple method is described for simultaneous determination of six main nucleosides and bases including adenine, uracil, adenosine, guanosine, uridine and inosine in Cordyceps by capillary electrophoresis (CE). Chemometric optimization based on central composite design was employed to find the optimum resolution. The optimum factor space was defined by three parameters: buffer concentration, pH and concentration of acetonitrile as organic modifier. Resolution (Rs) was employed to evaluate the response function. A running buffer composed of 500 mM boric acid, adjusted pH to 8.6 with sodium hydroxide and 12.2% acetonitrile as modifier was found to be the most appropriate for the separation. The contents of the six components were determined by using adenosine monophosphate as an internal standard. Furthermore, hierarchical clustering analysis based on characteristics of 32 peaks in CE profiles from the tested 12 samples showed that natural and cultured Cordyceps were in different clusters. Adenosine and inosine were extracted as markers for discrimination of natural Cordyceps. The result of clustering based on the two peaks characteristics was in excellent agreement with that based on 32 peaks'. Thus, adenosine and inosine could be used as markers for quality control of natural and cultured Cordyceps.  相似文献   

4.
Iqbal J  Burbiel JC  Müller CE 《Electrophoresis》2006,27(12):2505-2517
Fast and convenient CE assays were developed for the screening of adenosine kinase (AK) inhibitors and substrates. In the first method, the enzymatic reaction was performed in a test tube and the samples were subsequently injected into the capillary by pressure and detected by their UV absorbance at 260 nm. An MEKC method using borate buffer (pH 9.5) containing 100 mM SDS (method A) was suitable for separating alternative substrates (nucleosides). For the CE determination of AMP formed as a product of the AK reaction, a phosphate buffer (pH 7.5 or 8.5) was used and a constant current (95 microA) was applied (method B). The methods employing a fused-silica capillary and normal polarity mode provided good resolution of substrates and products of the enzymatic reaction and a short analysis time of less than 10 min. To further optimize and miniaturize the AK assays, the enzymatic reaction was performed directly in the capillary, prior to separation and quantitation of the product employing electrophoretically mediated microanalysis (EMMA, method C). After hydrodynamic injection of a plug of reaction buffer (20 mM Tris-HCl, 0.2 mM MgCl2, pH 7.4), followed by a plug containing the enzyme, and subsequent injection of a plug of reaction buffer containing 1 mM ATP, 100 microM adenosine, and 20 microM UMP as an internal standard (I.S.), as well as various concentrations of an inhibitor, the reaction was initiated by the application of 5 kV separation voltage (negative polarity) for 0.20 min to let the plugs interpenetrate. The voltage was turned off for 5 min (zero-potential amplification) and again turned on at a constant current of -60 microA to elute the products within 7 min. The method employing a polyacrylamide-coated capillary of 20 cm effective length and reverse polarity mode provided good resolution of substrates and products. Dose-response curves and calculated K(i) values for standard antagonists obtained by CE were in excellent agreement with data obtained by the standard radioactive assay.  相似文献   

5.
Liu FK 《Analytica chimica acta》2011,694(1-2):167-173
In this study, gold nanoparticles (Au NPs) were separated using the reversed electrode polarity stacking mode (REPSM) of a capillary electrophoresis (CE) system for on-line enhancement prior to performing surfactant-modified CE separation. Under optimized conditions [running electrolyte buffer, sodium dodecyl sulfate (70 mM) and 3-cyclohexylamino-1-propanesulfonic acid (10 mM) at pH 10.0; applied voltage, 20 kV; operating temperature, 25°C; REPSM strategy for sample on-line concentration; REPSM applied prior to initializing separation], two parameters were varied to further enhance the concentration and separation of the Au NPs: (i) the rate of polarity switching (from -20 to +20 kV) between the REPSM and surfactant-modified CE separation modes and (ii) the length of the capillary column. At a polarity switching rate of 1333 kV min(-1) and a column length of ca. 83.5 cm, the resolution of the separation of a mixture of 5.3- and 40.1-nm Au NPs was greater than 19; in addition, the numbers of theoretical plates for the 5.3- and 40.1-nm-diameter Au NPs were greater than 15,000 and up to 1.15×10(7), respectively-the latter being extremely high. Thus, this CE-based method for separating Au NPs provided high performance in terms of separation resolution and the number of theoretical plates, both of which were improved by greater than fivefold relative to those published previously. Notably, the sensitivity enhancement factors for the 5.3- and 40.1-nm-diameter Au NPs were improved (by ca. 20- and 500-fold, respectively) relative to those obtained using conventional surfactant-modified CE separation.  相似文献   

6.
《Analytical letters》2012,45(18):2853-2867
Abstract

A capillary electrophoresis method with large volume sample stacking (CE-LVSS) has been developed and validated for the simultaneous determination of seven phenolic compounds: naringin, rutin, carnosic acid, apigenin, quercetin, morin, and chichoric acid. Optimization was carried out by response surface methodology and a set of 20 experiments helped to optimize the parameters such as the concentration of buffer, buffer pH, and applied voltage. Analytes were separated using a 50?µm diameter capillary with 56?cm effective length and an extended light path using 20?mM borate buffer at pH 9.2. The LVSS method was optimized and a three- to fivefold improvement in detectability was achieved with injection at 100 mbar for 20?s followed by polarity switching at –20?kV for 6?s. The linearity values of all seven analytes were observed in the concentration ranges from 0.5 to 50?µg/mL for CE and 0.1 to 25?µg/mL for LVSS. The limits of detection were from 0.012 to 0.241 and 0.003 to 0.086?µg/mL for CE and LVSS. The obtained limits of quantitation were within 0.041 to 0.802 for CE and 0.012 to 0.286?µg/mL for LVSS. The recoveries were between 91.1 and 109.8% and 96.3 and 108.4% for CE and LVSS, respectively. The developed method has been successfully applied for the quantitative determination of analyzed components from food samples that are important sources of these compounds.  相似文献   

7.
A fast and simple method for the direct, simultaneous detection of nitrite (NO(2) (-)) and nitrate (NO(3) (-)) in rat striatum has been developed using a capillary electrophoresis separation of low-flow push-pull perfusion samples. The method was optimized primarily for nitrite because nitrite is more important physiologically and is found at lower levels than nitrate. We obtained a complete separation of NO(2) (-) and NO(3) (-) in rat striatum within 1.5 min. Optimal CE separations were achieved with 20 mM phosphate, 2 mM cetyltrimethylammonium chloride (CTAC) buffer at pH 3.5. The samples were injected electrokinetically for 2 s into a 40 cm x 75 microm ID fused-silica capillary. The separation voltage was 10 kV (negative polarity), and the injection voltage was 16 kV (negative polarity). UV detection was performed at 214 nm. The limits of detection obtained at a signal-to-noise ratio (S/N) of 3 for nitrite and nitrate were 0.96 and 2.86 microM. This is one of the fastest separations of nitrite and nitrate of a biological sample ever reported. Interference produced by the high physiological level of chloride is successfully minimized by use of CTAC in the run buffer.  相似文献   

8.
We describe a rapid, simple, and highly efficient capillary electrophoresis (CE)-based method for the analysis of nanoparticles (NPs). In this study, we used the reversed electrode polarity stacking mode (REPSM) of CE to assess the feasibility of enhancing the detection of Au NPs and Au/Ag NPs, optimizing parameters such as the length of time for which the REPSM was applied, the concentrations of the buffer and the sodium dodecylsulfate (SDS) surfactant, and the pH. Under the optimized on-line enhancement conditions [buffer: SDS (40 mM) and 3-cyclohexylamino-1-propanesulfonic acid (CAPS; 10 mM) at pH 10.0; applied voltage: 20 kV; REPSM applied for 24s], the detection limits of the Au NPs and Au/Ag NPs increased by ca. 30- and 140-fold, respectively. In addition, when the NPs were subjected to on-line enhancement and separation by CE using diode array detection (DAD), this approach allowed chemical characterization of the NP species. Our results suggest that such CE analyses will be useful for accelerating the rates of fabrication and characterization of future nanomaterials.  相似文献   

9.
Herein, we report a new CE method to measure adenine nucleotides adenosine 5′‐triphosphate, adenosine 5′‐diphosphate, and adenosine 5′‐monophosphate in red blood cells. For this purpose, 20 mmol/L sodium acetate buffer at pH 3.80 was used as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of 25 kV and an overimposed pressure of 0.2 psi from inlet to outlet. A rapid separation of these analytes in less than 1.5 min was obtained with a good reproducibility for intra‐ and inter‐assay (CV<4 and 8%, respectively) and an excellent analytical recovery (from 98.3 to 99%). The applicability of our method was proved by measuring adenine nucleotides in red blood cells.  相似文献   

10.
Nucleotide pyrophosphatase/phosphodiesterase 1 (NPP1) is a membrane glycoprotein involved in the hydrolysis of extracellular nucleotides. Its main substrate is ATP yielding AMP and pyrophosphate. NPP1 has been proposed as a novel drug target, for diabetes type 2 and the treatment of calcium pyrophosphate dihydrate deposition disease leading to inflammatory arthritis. The monitoring of NPP1 reactions is difficult because its velocity is very slow requiring highly sensitive analytical procedures. In this study, a method of large‐volume sample stacking with polarity switching was developed, and separations were optimized. Large sample volumes were loaded by hydrodynamic injection (5 psi, 13 s) followed by removal of a large plug of sample matrix from the capillary using polarity switching (?10 kV). The stacked analytes were subsequently separated in phosphate buffer (100 mM, pH 9.2) at 20 kV. The validated method was found to be linear (R2 = 0.9927) in the concentration range of 0.05–50 μM of AMP, with high accuracy and precision. The determined LOD and LOQ of AMP were 18 nM and 60 nM, respectively. Compared to a previously reported CE procedure using sweeping technique, a fivefold improvement of sensitivity was achieved. Moreover, the new technique was faster, and reproducibility of migration times was improved (RSD value = 1.2%). Importantly, adenine nucleotide analogs and derivatives tested as NPP1 inhibitors could be completely separated from the substrate ATP and the enzymatic product AMP. The method was applied to NPP1 inhibition assays investigating nucleotide‐derived inhibitors in the presence of ATP.  相似文献   

11.
This study describes an on-line stacking CE approach by sweeping with whole capillary sample filling for analyzing five anabolic androgenic steroids in urine samples. The five anabolic steroids for detection were androstenedione, testosterone, epitestosterone, boldenone, and clostebol. Anabolic androgenic steroids are abused in sport doping because they can promote muscle growth. Therefore, a sensitive detection method is imperatively required for monitoring the urine samples of athletes. In this research, an interesting and reliable stacking capillary electrophoresis method was established for analysis of anabolic steroids in urine. After liquid–liquid extraction by n-hexane, the supernatant was dried and reconstituted with 30 mM phosphate buffer (pH 5.00) and loaded into the capillary by hydrodynamic injection (10 psi, 99.9 s). The stacking and separation were simultaneously accomplished at ?20 kV in phosphate buffer (30 mM, pH 5.0) containing 100 mM sodium dodecyl sulfate and 40 % methanol. During the method validation, calibration curves were linear (r?≥?0.990) over a range of 50–1,000 ng/mL for the five analytes. In the evaluation of precision and accuracy for this method, the absolute values of the RSD and the RE in the intra-day (n?=?3) and inter-day (n?=?5) analyses were all less than 6.6 %. The limit of detection for the five analytes was 30 ng/mL (S/N?=?5, sampling 99.9 s at 10 psi). Compared with simple MECK, this stacking method possessed a 108- to 175-fold increase in sensitivity. This simple and sensitive stacking method could be used as a powerful tool for monitoring the illegal use of doping.  相似文献   

12.
This paper describes approaches for stacking large volumes of sample solutions containing a mixture of chlorophenols and chlorophenoxyacetic acids as their anions in capillary zone electrophoresis, and compares results to standard capillary electrophoresis (CE) and normal stacking modes. In order to increase the amount of sample injected beyond the optimal conditions and maintain high resolution, the sample introduction buffer must be removed after the stacking process is completed. This is achieved by pumping the sample buffer out of the column using polarity switching. Large sample volumes are loaded by hydrodynamic injection, then stacked at the injection buffer/run electrolyte interface, followed by the removal of the large plug of low-conductivity sample matrix from the capillary column using polarity switching and finally the separation of the stacked anions in a basic buffer (pH 8.65). Around 10- and 40-fold improvement of sensitivity was achieved by normal stacking and large-volume stacking with polarity switching, respectively, when compared to the standard CE analysis. Sweeping-micellar electrokinetic capillary chromatography (MEKC) was also investigated for the purpose of comparison to the stacking technique. The method should be suitable for the analysis of these chemical compound classes in industrial chlorophenoxyacetic acid manufacture.  相似文献   

13.
Yang FQ  Li S  Li P  Wang YT 《Electrophoresis》2007,28(11):1681-1688
A CEC method is described for the simultaneous determination of 11 nucleosides and nucleobases including cytosine, uracil, uridine, hypoxanthine, 2'-deoxyuridine, inosine, guanosine, thymidine, adenine, adenosine, and cordycepin in Cordyceps using 5-chlorocytosine arabinoside as internal standard (IS). Chemometric optimization based on central composite design was employed to find the optimum conditions. The factors for optimization were defined as three parameters: voltage, pH, and concentration of ACN as organic modifier. The resolution (R(s)) between inosine and guanosine, as well as the entire run time were employed to evaluate the response function. A running buffer composed of 4 mM ammonium acetate and 2 mM triethylamine (TEA) adjusted to pH 5.3 using acetic acid, and containing 3% ACN as modifier, with gradient voltage (0-4 min: 20 kV, 4-12 min: linear gradient from 20 to 30 kV; 12-16 min: 30 kV) were found to be the optimum conditions for the separation. Separation of the 11 investigated compounds and 5-chlorocytosine arabinoside was achieved within 16 min. The contents of the 11 compounds in natural and cultured Cordyceps sinensis, and cultured Cordyceps militaris were also compared. The result showed that CEC is an efficient method for analysis of nucleosides and nucleobases in Cordyceps, which is helpful to control the quality of this valued traditional Chinese medicine.  相似文献   

14.
Zhang H  Zhou L  Chen X 《Electrophoresis》2008,29(7):1556-1564
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved.  相似文献   

15.
Determination of melatonin (MT) (N-acetyl-5-methoxytryptamine) and related indole compounds using standard capillary electrophoresis (CE) system with UV detection was investigated. Satisfactory separations of six analytes i.e. l-tryptophan (l-TRP), 5-methoxyindoleacetic acid (5-MIAA), 6-hydroxymelatonin (6-HMT), MT, serotonin (SER) and 5-methoxytryptamine (5-MTRA) were performed employing micellar electrokinetic chromatography (MEKC). The optimal background electrolytes (BGE) used for separations were 20mM tetraborate buffer (pH 9.2) and 20mM phosphate buffer (pH 3.3) when employing techniques with normal and reverse migration of micelles, respectively. Fifty millimolar sodium dodecyl sulfate (SDS) was employed as the pseudostationary phase and voltage of +/-20kV was used throughout the investigation. On-line preconcentration techniques, stacking and sweeping, were applied in order to overcome high detection limits that are a serious drawback of CE with UV detection. A comparison of used techniques, concerning enhancement factors and limits of detection (LOD), is presented. Obtained results show that the use of stacking with reverse migrating micelles (SRMM) as one of preconcentration techniques allows obtaining the lowest estimated LODs for MT at the level of 30ng/mL with injection time of 99s at 0.5psi. Estimated LODs for other analytes in these conditions were, 21, 26 and 100ng/mL for l-TRP, 5-MIAA and 6-HMT, respectively. Signals of 5-MTRA and SER obtainable only with 10s injection allowed reaching estimated LODs of 62.5 and 130ng/mL, respectively. Analysis of spiked, diluted human serum was carried out as a preliminary application illustration of developed procedure.  相似文献   

16.
A novel chiral selector, clindamycin succinate, was synthesized and first used as a chiral selector in capillary electrophoresis (CE). The chiral resolution ability of this kind of clindamycin derivation was studied by CE using some racemic drugs as model analytes. From the experimental results, it was found that both resolution and selectivity of the selector were dependent on the following parameters: concentration of chiral selectors, pH of the running buffer, temperature of the capillary column, applied voltage and organic modifier used. The results show that the chiral selector possesses high resolution toward some racemic drugs, including ofloxacin, chlorphenamine, tryptophan, propranolol, sotalol and metoprolol. Excellent chiral resolution of these tested drugs was achieved under the optimal conditions of 50 mM clindamycin succinate, 10% MeOH v/v, 50 mM Tris buffer, pH 4.0, at 22 kV and 20 °C within 25 min.  相似文献   

17.
Lin YH  Chiang JF  Lee MR  Lee RJ  Ko WK  Wu SM 《Electrophoresis》2008,29(11):2340-2347
A cation-selective exhaustive injection and sweeping micellar EKC (CSEI-Sweep-MEKC) was established to analyze morphine and its four metabolites, including codeine, normorphine (NM), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G). After SPE, the urine samples were analyzed by this CE method. The phosphate buffer (75 mM, pH 2.5) containing 30% methanol was first filled into an uncoated fused-silica capillary (40 cm, 50 microm id), then a high-conductivity buffer (120 mM phosphate, 10.3 kPa for 99.9 s) followed. The pretreated urine sample was loaded by electrokinetic injection (10 kV, 600 s). The stacking and separation were performed by using phosphate buffer (25 mM, pH 2.5) containing 22% methanol and 100 mM SDS at -20 kV, and detected at 200 nm. During method validation, calibration plots were linear (r > or = 0.998) over a range of 30-3000 ng/mL for morphine, NM, and codeine, 100-2000 ng/mL for M6G, and 80-3200 ng/mL for M3G. The LODs (S/N = 5, sampling 600 s at 10 kV) were 10 ng/mL for morphine, NM, and codeine, 35 ng/mL for M6G, and 25 ng/mL for M3G. This stacking CE method could increase 2500-fold sensitivity of codeine, when comparing with CZE. Five addicts' urine specimens were analyzed. Their results were compared with those of LC-MS-MS, and showed good coincidence. This method could be feasible for monitoring morphine and its metabolites in forensic interest and pharmacokinetic investigations.  相似文献   

18.
Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) was directly used to test some abuse drugs in human urine, including morphine (M), codeine (C), ketamine (K) and methamphetamine (MA). First, phosphate buffer (50 mM, pH 2.5) containing 30% methanol was filled into uncoated fused silica capillary (40 cm, 50 microm I.D.), then high conductivity buffer (100 mM phosphate, 6.9 kPa for 99.9 s) was followed. Electrokinetic injection (10 kV, 500 s) was used to load samples and to enhance sensitivity. The stacking step and separation were performed at -20 kV and 200 nm using phosphate buffer (25 mM, pH 2.5) containing 20% methanol and 100 mM sodium dodecyl sulfate. Using CSEI-Sweep-MEKC, the analytes could be simultaneously analyzed and have a detection limit down to ppb level. It was unnecessary to have sample pretreatments. During method validation, calibration plots were linear (r>or=0.9982) over a range of 150-3,000 ng/mL for M and C, 250-5,000 n g/mL for MA, and 50-1,000 ng/mL for K. The limits of detection were 15 ng/mL for M and C, and 5 ng/mL for MA and K (S/N=3, sampling 500 s at 10 kV). Comparing with capillary zone electrophoresis, the results indicated that this stacking method could increase 6,000-fold sensitivity for analysis of MA. Our method was applied for analysis of 28 real urine samples. The results showed good coincidence with immunoassay and GC-MS. This method was feasible for application to detect trace levels of abused drugs in forensic analysis.  相似文献   

19.
Cheng HL  Jong YJ  Li JH  Ko WK  Wu SM 《Electrophoresis》2006,27(23):4711-4716
Direct analysis of methamphetamine, amphetamine, and p-hydroxymethamphetamine in urine was achieved by cation-selective exhaustive injection and sweeping micellar EKC. A bare fused-silica capillary (40 cm, 50 microm id) was filled with phosphate buffer (80 mM, pH 3, containing 20% ACN). Then a high-conductivity buffer (100 mM phosphate, pH 3; 6.9 kPa for 2.5 min) was injected. Samples were loaded using electrokinetic injection (10 kV, 600 s) which created long zones of cationic analytes. To enhance sensitivity by sweeping, the stacking step was performed using a phosphate buffer (50 mM, pH 3, containing 20% ACN and 100 mM SDS) at -20 kV before separation by MEKC. This method was capable of detecting the analytes at ppb levels. The calibration plots were linear (r(2) >or= 0.9948) over a range of 100-5000 ng/mL for methamphetamine, and 100-2000 ng/mL for amphetamine and p-hydroxymethamphetamine. The LODs (S/N = 3) were 20 ng/mL for methamphetamine, and 15 ng/mL for amphetamine and p-hydroxymethamphetamine. The method was applied to analysis of 14 urine samples of addicts and is suitable for screening suspected samples for forensic purposes. The results showed good agreement with fluorescence polarization immunoassay and GC-MS.  相似文献   

20.
An in‐capillary 2, 2‐diphenyl‐1‐picrylhydrazyl (DPPH)‐CE‐the DAD (in‐capillary DPPH‐CE‐DAD) combined with reversed‐electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β‐CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p‐coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH‐CE‐DAD method. Sensitivity was enhanced under reversed‐electrode polarity stacking mode and 10‐ to 31‐fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in‐capillary DPPH‐CE‐DAD method combined with reversed‐electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号