首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The variation of natural convection heat transfer from an isothermal horizontal cylinder confined between two adiabatic walls of constant height is investigated by Mach-Zehnder interferometry technique. This paper focuses on the chimney effect due to the vertical position changes of cylinder (Y) located between two walls with a constant distance of W measuring 1.5 cylinder diameter. The cylinder’s local and average Nusselt numbers are determined for ratio of vertical position to its diameter ranging from Y/D = (0 to 10), and the Rayleigh number ranging from 3.5 × 103 to 1.4 × 104. There is an optimum distance between the walls in which the Nusselt number is maximum. Results are indicated with a single correlation which gives the average Nusselt number as a function of the ratio of vertical position to cylinder diameter and the Rayleigh number. The experimental data shows that there is an optimum vertical position for the cylinder at which the Nusselt number has a maximum value at each Rayleigh number. This optimal vertical position is derived from the correlation and is presented by an equation. The value of the optimum vertical position increases as the Rayleigh number increases.  相似文献   

2.
Steady state two-dimensional free convection heat transfer from a horizontal, isothermal cylinder in a horizontal array of cylinders consists of three isothermal cylinders, located underneath a nearly adiabatic ceiling is studied experimentally. A Mach–Zehnder interferometer is used to determine thermal field and smoke test is made to visualize flow field. Effects of the cylinders spacing to its diameter (S/D), and cylinder distance from ceiling to its diameter (L/D) on heat transfer from the centered cylinder are investigated for Rayleigh numbers from 1500 to 6000. Experiments are performed for an inline array configuration of horizontal cylinders of diameters D = 13 mm. Results indicate that due to the nearly adiabatic ceiling and neighboring cylinders, thermal plume resulted from the centered cylinder separates from cylinder surface even for high L/D values and forming recirculation regions. By decreasing the space ratio S/D, the recirculation flow strength increases. Also, by decreasing S/D, boundary layers of neighboring cylinders combine and form a developing flow between cylinders. The strength of developing flow depends on the cylinders Rayleigh number and S/D ratio. Due to the developing flow between cylinders, the vortex flow on the top of the centered cylinder appears for all L/D ratios and this vortex influences the value of local Nusselt number distribution around the cylinder.Variation of average Nusselt number of the centered cylinder depends highly on L/D and the trend with S/D depends on the value of Rayleigh number.  相似文献   

3.
Air-side heat transfer and friction characteristics of five kinds of fin-and-tube heat exchangers, with the number of tube rows (N = 12) and the diameter of tubes (Do = 18 mm), have been experimentally investigated. The test samples consist of five types of fin configurations: crimped spiral fin, plain fin, slit fin, fin with delta-wing longitudinal vortex generators (VGs) and mixed fin with front 6-row vortex-generator fin and rear 6-row slit fin. The heat transfer and friction factor correlations for different types of heat exchangers were obtained with the Reynolds numbers ranging from 4000 to 10000. It was found that crimped spiral fin provides higher heat transfer and pressure drop than the other four fins. The air-side performance of heat exchangers with the above five fins has been evaluated under three sets of criteria and it was shown that the heat exchanger with mixed fin (front vortex-generator fin and rear slit fin) has better performance than that with fin with delta-wing vortex generators, and the slit fin offers best heat transfer performance at high Reynolds numbers. Based on the correlations of numerical data, Genetic Algorithm optimization was carried out, and the optimization results indicated that the increase of VG attack angle or length, or decrease of VG height may enhance the performance of vortex-generator fin. The heat transfer performances for optimized vortex-generator fin and slit fin at hand have been compared with numerical method.  相似文献   

4.
Experiments were performed to investigate the effect of duct height on heat transfer enhancement of a surface affixed with arrays (7 × 7) of short rectangular plate fins of a co-rotating type pattern in the duct. An infrared imaging system is used to measure detailed distributions of the heat transfer at the endwall along with the fin base. An infrared camera of TVS 8000 with 160 × 120 point In–Sb sensor was used to measure the temperature distributions in order to calculate the local heat transfer coefficients of the representative fin regions. Pressure drop and heat transfer experiments were performed for a co-rotating fin pattern varying the duct height from 20?50 mm. The friction factor calculated from the pressure drop shows that comparatively larger friction occurs for the smaller duct cases and the friction factor slowly decreases with increasing Reynolds number. The effect of duct height on the area-averaged heat transfer results show that heat transfer initially increases with duct height and then finally decreases with increasing the duct height. Detailed heat transfer analysis and iso-heat transfer coefficient contour gives a clear picture of heat transfer characteristics of the overall surface. The relative performance graph indicates that a 25 mm duct is the optimum duct height for the highest thermal performance. In addition, a significant thermal enhancement, 2.8?3.8 times the smooth surface, can be achieved at lower Reynolds number with a co-rotating fin pattern in the duct.  相似文献   

5.
This paper presents a numerical study of the conjugate heat transfer (natural convection, surface thermal radiation and conduction) in a square cavity with turbulent flow. The cavity has one vertical isothermal wall, two horizontal adiabatic walls and one vertical semitransparent wall with a selective coating applied to the inner side to control the solar radiation transmission. Later on the semitransparent wall is replaced with another one without the selective coating. The mathematical model for the turbulent flow in the cavity was solved using the finite volume method. The system had the following conditions: the uniform temperature in the isothermal wall was 21 °C, the external ambient temperature was fixed at 35 °C and on the semitransparent wall the direct normal solar irradiation of 750 W/m2 was considered constant. The Rayleigh number was varied in the range of 109 ? Ra ? 1012 by changing the lengths of the cavity from 0.70 m to 6.98 m, respectively. The results show that, even though the air temperature of the cavity with the solar control film coating semitransparent wall (case A) is higher compared with the one without solar film coating (case B), the total amount of heat going through the cavity is lower compared to the one going through the cavity without solar control film. The total amount of energy transferred to the air in cavity for the case A was 41.98% less than for the case B. A set of correlations for the Nusselt number was obtained for both cases considering the conjugate heat transfer.  相似文献   

6.
Free convection heat transfer from an isothermal horizontal cylinder in the presence of DC positive corona discharge with a blade edge emitter electrode has been studied experimentally and numerically. A Mach–Zehnder interferometer was used to determine the local Nusselt numbers. The effect of corona discharge on heat transfer from the cylinder was investigated at Rayleigh numbers in the range between 1500 and 5000. To find the details of the flow patterns and to further verify the experimental results, numerical simulations were also performed. It was found that the numerical results are in good agreement with experimental data. By increasing the applied voltage up to 15.5 kV, the corona discharge generates a recirculation zone around the blade and below the lower stagnation point of the cylinder. The effect of the recirculation zone becomes stronger near the breakdown voltage (17 kV) and it is responsible for a local decrease in the cooling of the cylinder around the lower stagnation point. The results indicate that corona discharge has a significant effect on the average Nusselt number at lower Rayleigh numbers whereas it has smaller effect at higher Rayleigh numbers.  相似文献   

7.
Numerical investigation is made for three-dimensional fluid flow and convective heat transfer from an array of solid and perforated fins that are mounted on a flat plate. Incompressible air as working fluid is modeled using Navier–Stokes equations and RNG based k ? ? turbulent model is used to predict turbulent flow parameters. Temperature field inside the fins is obtained by solving Fourier’s conduction equation. The conjugate differential equations for both solid and gas phase are solved simultaneously by finite volume procedure using SIMPLE algorithm. Perforations such as small channels with square cross section are arranged streamwise along the fin’s length and their numbers varied from 1 to 3. Flow and heat transfer characteristics are presented for Reynolds numbers from 2 × 104 to 4 × 104 based on the fin length and Prandtl number is taken Pr = 0.71. Numerical computations are validated with experimental studies of the previous investigators and good agreements were observed. Results show that fins with longitudinal pores, have remarkable heat transfer enhancement in addition to the considerable reduction in weight by comparison with solid fins.  相似文献   

8.
Natural convection heat transfer in an inclined fin attached square enclosure is studied both experimentally and numerically. Bottom wall of enclosure has higher temperature than that of top wall while vertical walls are adiabatic. Inclined fin has also adiabatic boundary conditions. Numerical solutions have been done by writing a computer code in Fortran platform and results are compared with Fluent commercial code and experimental method. Governing parameters are Rayleigh numbers (8.105 ≤ Ra ≤ 4 × 106) and inclination angle (30° ≤ and ≤ 120°). The temperature measurements are done by using thermocouples distributed uniformly at the wall of the enclosure. Remarkably good agreement is obtained between the predicted results and experimental data. A correlation is also developed including all effective parameters on heat transfer and fluid flow. It was observed that heat transfer can be controlled by attaching an inclined fin onto wall.  相似文献   

9.
In this paper, we studied the convective heat transfer from a stream-wise oscillating circular cylinder. Two dimensional numerical simulations are conducted at Re = 100–200, A = 0.1–0.4 and F = fo/fs = 0.2–3.0 with the aid of the lattice Boltzmann method. In particular, detailed attentions are paid on the extensive numerical results elucidating the influence of oscillation frequency, oscillation amplitude and Reynolds number on the time-average and RMS value of the Nusselt number. Over the ranges of conditions considered herein, the heat transfer characteristics are observed to be influenced in an intricate manner by the value of the oscillation frequency (F), oscillation amplitude (A) and Reynolds number (Re). Firstly, the heat transfer is enhanced when the cylinder oscillates stream-wise with small amplitude and low frequency, while it will be reduced by large amplitude and high frequency. Secondly, the average Nusselt number (Nu (ave)) decreases against the increasing value of oscillation frequency, while the RMS value of the Nusselt number, Nu (RMS), displays an opposite trend. Third, we obtained a similar frequency effect on the heat transfer over the range of Reynolds numbers investigated in this paper. In addition, detailed analyses on phase portraits, energy spectrum are also made.  相似文献   

10.
This paper presents a numerical study of three-dimensional laminar mixed convection within a liquid flowing on a horizontal channel heated uniformly from below. The upper surface is free and assumed to be flat. The coupled Navier–Stokes and energy equations are solved numerically by the finite volume method taking into account the thermocapillary effects (Marangoni effect). When the strength of the buoyancy, thermocapillary effects and forced convective currents are comparable (Ri  O(1) and Bd = Ra/Ma  O(1)), the results show that the development of instabilities in the form of steady longitudinal convective rolls is similar to those encountered in the Poiseuille–Rayleigh–Bénard flow. The number and spatial distribution of these rolls along the channel depend on the flow conditions. The objective of this work is to study the influence of parameters, such as the Reynolds, Rayleigh and Biot numbers, on the flow patterns and heat transfer characteristics. The effects of variations in the surface tension with temperature gradients (Marangoni effect) are also considered.  相似文献   

11.
Natural convective heat transfer from an isothermal inclined cylinder with a square cross-section which have an exposed top surface and is, in general, inclined at an angle to the vertical has been numerically and experimentally studied. The cylinder is mounted on a flat adiabatic base plate, the cylinder being normal to the base plate. The numerical solution has been obtained by solving the dimensionless governing equations subject to the boundary conditions using the commercial cfd solver, FLUENT. The flow has been assumed to be symmetrical about the vertical center-plane through the cylinder. Results have only been obtained for Prandtl number of 0.7. Values of inclination angle between 0° and 180° and a wide range of Rayleigh number and the dimensionless cylinder width, W = w/h, have been considered. The effects of Dimensionless widths, Rayleigh numbers, and inclination angles on the mean Nusselt number for the entire cylinder and for the mean Nusselt numbers for the various surfaces that make up the cylinder have been examined. Empirical equations for the heat transfer rates from the entire cylinder have been derived.  相似文献   

12.
Experiments are carried out with air as the test gas to obtain the surface convective heating rate on a missile shaped body flying at hypersonic speeds. The effect of fins on the surface heating rates of missile frustum is also investigated. The tests are performed in a hypersonic shock tunnel at stagnation enthalpy of 2 MJ/kg and zero degree angle of attack. The experiments are conducted at flow Mach number of 5.75 and 8 with an effective test time of 1 ms. The measured stagnation-point heat-transfer data compares well with the theoretical value estimated using Fay and Riddell expression. The measured heat-transfer rate with fin configuration is slightly higher than that of model without fin. The normalized values of experimentally measured heat transfer rate and Stanton number compare well with the numerically estimated results.  相似文献   

13.
An experimental study in an open-ended vertical channel is carried out in order to describe the fluid dynamics and heat transfer of transient free convection inside a vertical rib-roughened channel asymmetrically heated at various uniform heat fluxes (650, 700, and 780 W/m2) corresponding to various modified Rayleigh numbers (3.65 × 106, 3.93 × 106 and 4.4 × 106). Two ribs are symmetrically located on each wall. The investigations focused more specifically on the influence of the ribs positions inside the channel and the modified Rayleigh number (Ra*) both in steady-state regime and during the transitional phase occurring just after the start of the heating on the flow structure and the heat transfer performance. The results showed the appearance of large-scale flow instabilities which will develop and propagate until the development of the pocket-like vortex (reversed flow). Also, the formation and breakup of recirculation eddies, vortex banishment, besides that a separation and shifting of the boundary layer from one wall to another are identified. The best position of the ribs for heat extraction depends on the magnitude of the Rayleigh number. In that case, the top position is the optimal position for the small and the moderate modified Rayleigh numbers.  相似文献   

14.
In the work an approach to avoid a circumferential temperature distribution existing during nucleate pool boiling on a horizontal cylinder within low heat flux densities is presented. The idea of the approach is local heat transfer enhancement by a porous layer application on a part of the heating surface. An experiment on nucleate pool boiling heat transfer from horizontal cylinders to saturated R141b and water under atmospheric pressure is reported. Experiments have been conducted using stainless steel tubes with the outside diameter between 8 mm and 23 mm with the active length of 250 mm. The outside surface of the tubes was smooth or partially coated with a porous metallic layer. In particular, measurements of inside circumferential temperature distribution have been performed.  相似文献   

15.
A computational study of heat transfer from rectangular cylinders is carried out. Rectangular cylinders are distinguished based on the ratio of the length of streamwise face to the height of the cross-stream face (side ratio, R). The simulations were performed to understand the heat transfer in a flow field comprising separation, reattachment, vortex shedding and stagnation. The Partially-Averaged Navier–Stokes (PANS) modeling approach is used to solve the turbulent flow physics associated and the wall resolve approach is used for the near wall treatment because of the flow separation involved. The simulations were performed using a finite volume based opensource software, OpenFOAM, at Reynolds number (Re) = 22,000 for rectangular cylinder at constant temperature kept in an air stream. Two critical side ratios were obtained, R = 0.62 and 3.0. At R = 0.62, the maximum value of the drag coefficient (Cd) = 2.681 was observed which gradually reduced by 54% at R = 4.0. The base pressure coefficient and global Nusselt number also attained the maximum value at R = 0.62 and from R = 2.5 to 3.0 a sharp discontinuous increase by 140% in the Strouhal number was observed. At R = 0.62, it was observed that the separated flow reattaches at the trailing edge after rolling over the side face and therefore increases the overall Nusselt number. The phase averaging was also performed to analyze the unsteady behavior of heat transfer.  相似文献   

16.
Effects of peripherally-cut twisted tape insert on heat transfer, friction loss and thermal performance factor characteristics in a round tube were investigated. Nine different peripherally-cut twisted tapes with constant twist ratio (y/W = 3.0) and different three tape depth ratios (DR = d/W = 0.11, 0.22 and 0.33), each with three different tape width ratios (WR = w/W = 0.11, 0.22 and 0.33) were tested. Besides, one typical twisted tape was also tested for comparison. The measurement of heat transfer rate was conducted under uniform heat flux condition while that of friction factor was performed under isothermal condition. Tests were performed with Reynolds number in a range from 1000 to 20,000, using water as a working fluid. The experimental results revealed that both heat transfer rate and friction factor in the tube equipped with the peripherally-cut twisted tapes were significantly higher than those in the tube fitted with the typical twisted tape and plain tube, especially in the laminar flow regime. The higher turbulence intensity of fluid in the vicinity of the tube wall generated by the peripherally-cut twisted tape compared to that induced by the typical twisted tape is referred as the main reason for achieved results. The obtained results also demonstrated that as the depth ratio increased and width ratio decreased, the heat transfer enhancement increased. Over the range investigated, the peripherally-cut twisted tape enhanced heat transfer rates in term of Nusselt numbers up to 2.6 times (turbulent regime) and 12.8 times (laminar regime) of that in the plain tube. These corresponded to the maximum performance factors of 1.29 (turbulent regime) and 4.88 (laminar regime).  相似文献   

17.
The natural convection on metallic foam-sintered plate at different inclination angles was experimentally studied. Seven copper foam samples with different pore densities (10–40 pore per inch), porosities (0.90–0.95), and aspect ratios (the ratio of foam thickness to sample length, 0.1–0.5) were measured at inclination angles of 0° (vertical orientation), 15°, 30°, 45°, 60°, 75°, 90° (horizontal orientation). The heat conduction and natural convection inside the foam both contributed to the total heat transfer. Although, the form and viscous drag, which are influenced by permeability and viscous friction in the thermal boundary layer respectively, tend to suppress the natural convection, the heat transfer was finally enhanced by the foam sintered surface due to large surface area extension. Optimum inclination range 60–75° corresponding to maximum average Nu number was found in the heat flux range of 600–1800 W/m2. The sintered foam surface with lower porosity and pore density was recommended for heat transfer enhancement. Particularly, the sample with porosity 0.9, pore density of 10 PPI, aspect ratio of 0.5 offered the highest average Nu number among the studied samples. An empirical correlation for modified Nusselt number at isoflux boundary condition considering the foam morphology parameter and inclination angle was proposed within deviation ±15% between the correlation and the experimental data.  相似文献   

18.
A non-similar boundary layer analysis is presented to study the flow, heat and mass transfer characteristics of non-Darcian mixed convection of a non-Newtonian fluid from a vertical isothermal plate embedded in a homogeneous porous medium with the effect of Soret and Dufour and in the presence of either surface injection or suction. The value of the mixed-convection parameter lies between 0 and 1. In addition, the power-law model is used for non-Newtonian fluids with exponent n < 1 for pseudoplastics n = 1 for Newtonian fluids and n > 1 for dilatant fluids. Furthermore, the coordinates and dependent variables are transformed to yield computationally efficient numerical solutions that are valid over the entire range of mixed convection, from the pure forced-convection limit to the pure free-convection limit, and the whole domain of non-Newtonian fluids, from pseudoplastics to dilatant fluids. The numerical solution of the problem is derived using a Runge–Kutta integration scheme with Newton–Raphson shooting technique. Distributions for velocity, temperature and concentration, as well as for the rate of wall heat and mass transfer, have been obtained and discussed for various physical parametric values.  相似文献   

19.
20.
This investigation had multiple goals. One goal was to obtain definitive information about the heat transfer characteristics of co-axial impinging jets, and this was achieved by measurements of the stagnation-point, surface-distribution and average heat transfer coefficients. These results are parameterized by the Reynolds number Re which ranged from 5000 to 25,000, the dimensionless separation distance between the jet exit and the impingement plate H/D (4–12), and the ratio of the inner diameters of the inner and outer pipes d/D (0–0.55). The d/D = 0 case corresponds to a single circular jet. The other major goal of this work was to quantify the velocity field of co-axial free jets (impingement plate removed). The velocity-field study included both measurements of the mean velocity and the turbulence intensity.It was found that the variation of the stagnation-point heat transfer coefficient with d/D attained a maximum at d/D = 0.55. Furthermore, the variation of the local heat transfer coefficient across the impingement surface was more peaked for d/D = 0 and became flatter with decreasing d/D. This suggests that for cooling a broad expanse of surface, co-axial jets of high d/D are preferable. On the other hand, for localized cooling, the single jet (d/D = 0) performed the best. In general, for a given Reynolds number, a co-axial jet yields higher heat transfer coefficients than a single jet. Off-axis velocity peaks were encountered for the jets with d/D = 0.105. The measurements of turbulence intensity yielded values as high as 18%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏