An integrated solid-phase spectrophotometry–FIA method is proposed for simultaneous determination of the mixture of saccharin (1,2-benzisothiazol-3(2H)-one-1,1-dioxide; E-954) (SA) and aspartame (N-l-α-aspartyl-l-phenylalanine-1-methyl ester; E-951) (AS). The procedure is based on on-line preconcentration of AS on a C18 silica gel minicolumn and separation from SA, followed by measurement, at λ=210 nm, of the absorbance of SA which is transiently retained on the adsorbent Sephadex G-25 placed in the flow-through cell of a monochannel FIA setup using pH 3.0 orthophosphoric acid–dihydrogen phosphate buffer, 3.75×10–3 mol L−1, as carrier. Subsequent desorption of AS with methanol enables its determination at λ=205 nm. With a sampling frequency of 10 h−1, the applicable concentration range, the detection limit, and the relative standard deviation were from 1.0 to 200.0 μg mL−1, 0.30 μg mL−1, and 1.0% (80 μg mL−1, n=10), respectively, for SA and from 10.0 to 200.0 μg mL−1, 1.4 μg mL−1, and 1.6% (100 μg mL−1, n=10) for AS. The method was used to determine the amounts of aspartame and saccharin in sweets and drinks. Recovery was always between 99 and 101%. The method enabled satisfactory determination of blends of SA and AS in low-calorie and dietary products and the results were compared with those from an HPLC reference method.  相似文献   

2.
A simple and rapid flow-injection spectrophotometric method for the determination of iron(III) and total iron is proposed. The method is based on the reaction between iron(III) and O-acetylsalicylhydroxamic acid (AcSHA) in a 2 % methanol solution resulting in an intense violet complex with strong absorption at 475 nm. Optimum conditions for the determination of iron(III) and the interfering ions were tested. The relative standard deviation for the determination of 5 μg L−1 iron(III) was 0.85 % (n = 10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 0.5 μg L−1, both based on the injection volumes of 20 μL. The method was successfully applied in the determination of iron(III) and total iron in water and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F and also by the AAS method.  相似文献   

3.
A highly sensitive and very simple spectrophotometric flow-injection analysis (FIA) method for the determination of iron(III) at low concentration levels is presented. The method is based on the measurement of absorbance intensity of the red complex at 410 nm formed by iron(III) and diphenylamine-4-sulfonic acid sodium salt (DPA-4-SA). It is a simple, highly sensitive, fast, and low cost alternative method using the color developing reagent DPA-4-SA in acetate buffer at pH 5.50 and the flow-rate of 1 mL min−1 with the sample throughput of 60 h−1. The method provided a linear determination range between 5 μg L−1 and 200 μg L−1 with the detection limit (3S) of 1 μg L−1 of iron(III) using the injection volume of 20 μL. FIA variables influencing the system performance were optimized. The amount of iron(III) and total iron in river and seawater samples was successfully determined. Repeatability of the measurements was satisfactory at the relative standard deviation of 3.5 % for 5 determinations of 10 μg L−1 iron(III). The accuracy of the method was evaluated using the standard addition method and checked by the analysis of the certified material Std Zn/Al/Cu 43 XZ3F.  相似文献   

4.
A simple, selective and sensitive kinetic method for the determination of nitrite in water was developed. The method is based on the catalytic effect of nitrite on the oxidation of methylene blue (MB) with bromate in a sulfuric acid medium. During the oxidation process, absorbance of the reaction mixture decreases with the increasing time, inversely proportional to the nitrite concentration. The reaction rate was monitored spectrophotometrically at λ = 666 nm within 30 s of mixing. Linear calibration graph was obtained in the range of 0.005–0.5 μg mL−1 with a relative standard deviation of 2.09 % for six measurements at 0.5 μg mL−1. The detection limit was found to be 0.0015 μg mL−1. The effect of different factors such as acidity, time, bromate concentration, MB concentration, ionic strength, and order of reactants additions is reported. Interference of the most common foreign ions was also investigated. The optimum experimental conditions were: 0.38 mol L−1 H2SO4, 5 × 10.4 mol L−1 KBrO3, 1.25 × 10.5 mol L−1 MB, 0.3 mol L−1 sodium nitrate, and 25°C. The proposed method was conveniently applied for the determination of nitrite in spiked drinking water samples.  相似文献   

5.
This paper reports silica gel loaded with p-tert-butylcalix[8]arene as a new solid phase extractor for determination of trace level of uranium. Effective extraction conditions were optimized in column methods prior to determination by spectrophotometry using arsenazo(III). The results showed that U(VI) ions can be sorbed at pH 6 in a mini-column and quantitative recovery of U(VI) (>95–98%) was achieved by stripping 0.4 mol L−1 HCl. The sorption capacity of the functionalized sorbent is 0.072 mmol uranium(VI) g−1 modified silica gel. The relative standard deviation and detection limit were 1.2% (n = 10) for 1 μg uranium(VI) mL−1 solution and 0.038 μg L−1, respectively. The method was employed to the preconcentration of U(VI) ions from spiked ground water samples.  相似文献   

6.
A simple and fast flow injection fluorescence quenching method for the determination of iron in water has been developed. Fluorimetric determination is based on the measurement of the quenching effect of iron on salicylic acid fluorescence. An emission peak of salicylic acid in aqueous solution occurs at 409 nm with excitation at 299 nm. The carrier solution used was 2 × 10−6 mol L−1 salicylic acid in 0.1 mol L−1 NH4+/NH3 buffer solution at pH 8.5. Linear calibration was obtained for 5–100 μg L−1 iron(III) and the relative standard deviation was 1.25 % (n = 5) for a 20 μL injection volume iron(III). The limit of detection was 0.3 μg L−1 and the sampling rate was 60 h−1. The effect of interferences from various metals and anions commonly present in water was also studied. The method was successfully applied to the determination of low levels of iron in real samples (river, sea, and spring waters).  相似文献   

7.
A satisfactory method was described for separation and preconcentration of ultratrace amounts of fluoride ions enriched by zirconia (ZrO2) as an inorganic ion exchanger. Fluoride ions can be adsorbed rapidly and selectively on zirconia from an acidic solution (pH 4.8) then reversibly desorbed by increasing pH up to 13. A flow system consisting of a column packed with zirconia impregnated on cellulose fibers and an ion-selective electrode was used for the determination of fluoride. The RSD was found to be 1.6% and the detection limit defined by S/N = 3 was 3 × 10−9 mol L−1. The interference effects of various ions, such as nitrate, sulfate, halides, alkaline, and alkaline earth ions, which may be found in the environmental water, were studied, and it was found that they were tolerated even at high concentrations. The method was applied to determine fluoride in drinking water, which contains ultratrace amounts of fluoride. The concentration of fluoride was found to be 42 μg L−1, which is confirmed by spiking 2 μmol fluoride to the drinking water with a recovery of 99%. Published in Russian in Zhurnal Analiticheskoi Khimii, 2006, Vol. 61, No. 2, pp. 179–183. The text was submitted by the authors in English.  相似文献   

8.
In this work, the hyphenation of the multisyringe flow injection analysis technique with a 100-cm-long pathlength liquid core waveguide has been accomplished. The Cl/Hg(SCN)2/Fe3+ reaction system for the spectrophotometric determination of chloride (Cl) in waters was used as chemical model. As a result, this classic analytical methodology has been improved, minimizing dramatically the consumption of reagents, in particular, that of the highly biotoxic chemical Hg(SCN)2. The proposed method features a linear dynamic range composed of two steps between (1) 0.2–2 and (2) 2–8 mg Cl L−1, thus extended applicability due to on-line sample dilution (up to 400 mg Cl L−1). It also presents improved limits of detection and quantification of 0.06 and 0.20 mg Cl L−1, respectively. The coefficient of variation and the injection throughput were 1.3% (n = 10, 2 mg Cl L−1) and 21 h−1. Furthermore, a very low consumption of reagents per Cl determination of 0.2 μg Hg(II) and 28 μg Fe3+ has been achieved. The method was successfully applied to the determination of Cl in different types of water samples. Finally, the proposed system is critically compared from a green analytical chemistry point of view against other flow systems for the same purpose.  相似文献   

9.
A new method for the determination of nitrobenzene (NB) by differential pulse voltammetry (DPV) based on an adsorptive stripping technique was developed. Cyclic voltammetry (CV) was used in a comparative investigation into the electrochemical reduction of NB at a glassy carbon electrode (GCE). With this electrode, the sharp peak of NB appeared at −0.71 V (vs. Ag/AgCl). The experimental parameters were optimized. Studies on the effect of pH on the peak height and peak potential were carried out over the pH range ca. 9.0–11.5 with sodium carbonate/sodium hydrogen carbonate buffer solution. A solution of pH 9.9 was chosen as analytical medium. Cathodic peak currents were found to be linearly related to the concentration of NB over the range ca. 12.3–1.23 × 104 μg L−1 with relative standard deviations of ca. 3.26–6.75%. The detection limit of NB in water was 5.42 μg L−1. The interference of organic and inorganic species on the voltammetric response was also studied. The proposed method was applied to the determination of NB in wastewater samples with an average recovery of ca. 95.9–102.4%.  相似文献   

10.
A simple micellar liquid chromatographic technique for deltamethrin determination was developed and validated. The method provided to be suitable for deltamethrin determination in pediculicide shampoo. Kromasil C18 column (150 mm×4.6 mm, 5 μm) and mobile phase −0.12 M sodium dodecyl sulfate with 9% (v/v) 1-butanol were used for deltamethrin separation. Detection wavelength was 265 nm. The retention time was about 15 min. Different validation parameters were evaluated. The specificity of the method was demonstrated. Linearity was established in the range 10–40 μg L−1. The limits of detection and quantitation were 1.06 and 3.22 μg mL−1, respectively. The method showed excellent accuracy (100.6%) and precision (repeatability) gave a relative standard deviation of less than 1%. The influence of the various method parameters (robustness study) was also studied.  相似文献   

11.
Summary Two procedures, based on large-volume injection with a programmed-temperature vaporizer (PTV), have been developed for the determination of several triazine and organophosphorus pesticides. The use of PTV for injection in gas chromatography (GC) has enabled the introduction of up to 200 μL sample extract into the GC, thus increasing the sensitivity of the method. PTV injection has been combined off-line with two different microextraction procedures—liquid-liquid partition and solid-phase extraction. A simple and rapid off-line liquid-liquid microextraction procedure (5 mL water/1 mL methyltert-butyl ether) was applied to surface water samples spiked at levels between 0.01 and 5μg L−1. Recoveries of the overall procedure were >80% and the precision was better than 15%. Detection limits were <30 ngL−1 from 200-μL injections in GC-NPD analysis of triazines and GC-FPD analysis of organophosphorus pesticides. Off-line automated solid-phase extraction with C18 cartridges has been applied to water samples (50 mL) spiked at 0.01, 0.1 and 1 μg L−1. The overall procedure was satisfactory (recoveries >80% and coefficients of variation <12%) and the limits of detection ranged from 1 to 9 ng L−1. Finally, several surface water samples were anlysed, and triazine herbicides were detected at concentrations of approx. 0.1–0.2 μg L−1. The results were similar to those obtained by conventional solvent extraction then GC-MSD after splitless injection of 2 μL.  相似文献   

12.
The use of malonic acid as a complexing agent has enabled a new method to be devised to allow the determination of magnesium to be made using miniaturised isotachophoresis. Using a leading electrolyte of 10 mmol L−1 caesium hydroxide and 2 mmol L−1 malonic acid at pH 5.1 gave the method a high specificity towards magnesium. Investigations using a poly(methyl methacrylate) chip device with an integrated conductivity detector showed that no interference from calcium, strontium, barium and sodium should occur. The method was found to be linear over the range of magnesium concentrations from 0.625 to 75 mg L−1 and the limit of detection was calculated to be 0.45 mg L−1. Separations were demonstrated with water samples but the procedure should also be applicable to more complex sample matrices such as inorganic explosive residues, blood or urine.  相似文献   

13.
Speciation analysis of Sb(III) and Sb(V) in a soil sample was performed through extraction and on-line isotope dilution concentration determination after a chromatographic separation. The total Sb concentration found in a through traffic contaminated soil sample was (4.17 μg g−1, 0.3 μg g−1 SD, n=6). It was determined using ICP-MS after soil digestion using the sodium peroxide sintering method. The optimized extraction procedure for speciation analysis was carried out using 100 mmol L−1 citric acid at pH 2.08 by applying an ultrasonic bath for 45 min at room temperature. The effects of citric acid concentration (0–500 mmol L−1), pH (1–6), and temperature (30–60°C) on inorganic antimony species distribution in the examined sample were studied and optimized. The separation of Sb(III) and Sb(V) was achieved using an anion exchange column (PRP-X100) and 10 mmol L−1 EDTA and 1 mmol L−1 phthalic acid at pH 4.5 as a mobile phase. The eluent from the HPLC was mixed with an enriched (94.2%) 123Sb spike solution that was pumped by a peristaltic pump with a constant flow rate (0.5 mL min−1) in a three-way valve. The blend passed directly to the Conikal nebulizer of the ICP-MS. By using the above extraction procedure and methodology, 43.2% Sb(V) (2.9% RSD, n=3) and 6.0% Sb(III) (1.3% RSD, n=3) of total Sb found in the sample could be detected. The detection limits achieved by the proposed method were 20 ng L−1 and 65 ng L−1 for Sb(V) and Sb(III), respectively. The precision, evaluated by using RSD with 100 ng L−1 calibration solutions, was 2.7% and 3.2% (n=6) for Sb(V) and Sb(III), respectively, in aqueous solutions.  相似文献   

14.
Summary An ion-chromatographic procedure is described for the determination of selenium (VI) at μg L−1 level in the presence of anions and heavy metal ions. Maximum permissible concentrations and effects from each interfering substance were investigated for the Se concentration range 12.5–1,000 μg L−1. The method, optimized for the detection of SeO 4 2− , gives results suitable for speciation analysis. Total selenium can be determined after complete conversion to selenate ion by oxidation with KMnO4. The detection limit of selenium is 4.8 μg L−1 (0.96 ng for 200 μL sample). Paper presented at the 41st Pittsburgh Conference, New York, March 5–9, 1990.  相似文献   

15.
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h−1. Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 μL s−1. For a concentration range between 0.010 and 0.25 mg L−1, the current (i p, μA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L−1): i p = (−20.5 ± 0.3)C paraquat − (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 μg L−1, respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.  相似文献   

16.
Z. Chen  B. Li  M. Miao  G. Yang  J. Yin  Q. Su 《Mikrochimica acta》2005,152(1-2):93-97
In this paper, 4-hydroxy-1-naphthalthiorhodanine (HNTR) was synthesized, and a new method for the simultaneous determination of palladium, platinum and rhodium ions as metal-HNTR chelates was developed using rapid column high-performance liquid chromatography combined with on-line enrichment. The palladium, platinum and rhodium ions were pre-column derivatized with HNTR to form colored chelates. The Pb-HNTR, Pt-HNTR and Rh-HNTR chelates could be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column [ZORBAX Stable Bound, 4.6 × 10 mm, 1.8 μm] with a buffer solution of 0.05 mol L−1 sodium acetate-acetic acid (pH 4.0) as mobile phase. After enrichment, and by switching the six-ports switching valve, the retained chelates were back-flushed by mobile phase and traveling towards the analytical column. Separation of these chelates on the analytical column [ZORBAX Stable Bound, 4.6 × 50 mm, 1.8 μm] was satisfactory with 68% acetonitrile (containing 0.05 mol L−1 of pH 4.0 sodium acetate-acetic acid buffer salt and 0.1% of tritonX-100) as mobile phase. Palladium, platinum and rhodium were separated completely within 2 min. The detection limits (S/N = 3) of palladium, platinum and rhodium are 1.2 ng L−1, 1.5 ng L−1 and 1.8 ng L−1, respectively. This method was applied to the determination of palladium, platinum and rhodium in water, urine and soil samples with good results.  相似文献   

17.
This paper described the determination of p-nitroaniline in a double organic substrate oscillating system of tartrate-acetone-Mn2+-KBrO3-H2SO4. Under the optimum conditions, temperature was chosen as a control parameter to design the bifurcation point and proposed a convenient method for determination of p-nitroaniline. Results showed that the system consisting of 3.5 mL 0.06 mol L−1 tartrate, 4.0 mL 0.7 mol L−1 H2SO4, 1.5 mL 1.5×10−4 mol L−1 MnSO4, 4.0 mL 0.4 mol L−1 acetone and 7.0 mL 0.05 mol L−1 KBrO3 was very sensitive to the surrounding at 33.5°C. A good linear relationship between the potential difference and the negative logarithm concentration of p-nitroaniline was obtained to be in the range of 2.50×10−7∼3.75×10−5 mol L−1 with a lower detection limit of 2.50×10−8 mol L−1.   相似文献   

18.
Estrone is one of the important potential endocrine-disrupting compounds, and the sensitive and reliable analytical methods for the determination of estrone are required for the assurance of human health. In this paper, using estrone as template molecule, 3-aminopropyltriethoxysilane as function monomer, and tetraethoxysilicane as cross-linker, a highly selective molecularly imprinted microsphere was synthesized by surface molecular imprinting technique combined with a sol–gel process. The imprinted material was characterized by the Fourier transform infrared and static adsorption experiments, and the results showed that it exhibited good recognition and selective ability for estrone. A novel method for separation and determination of trace estrone in environmental sample was developed using on-line molecularly imprinted solid-phase extraction coupled to high-performance liquid chromatography. With a sample loading flow rate of 2.6 mL min−1 for a 9.6-min extraction, the enrichment factor obtained by the slopes of the linear portion in comparison with the direct injection of 10 μL standard sample solution was 1,045. The detection limit (S/N = 3) was 5.7 ng L−1, and the relative standard deviations for nine replicate extractions of 5.0 μg L−1 estrone was less than 10.0%. This method was evaluated for quantitative determination of estrone in well and lake water samples spiked at two levels (0.5 and 1.0 μg L−1) with recoveries ranging from 86% to 95%.   相似文献   

19.
Summary A reversed-phase liquid chromatographic method with sodium dodecylsulphate-n-propanolwater as mobile phase has been used to separate and determine six water-soluble vitamins in twelve minutes. The analytical characteristics linear range, sensitivity, detection limits, and precision were evaluated. The lowest detection limits were those of nicotinic acid (not usually present in pharmaceutical products), 0.7 mgL−1, nicotinamide, 1.3 mg L−1, and pyridoxine, 1.4 mg L−1. When the method was applied to the determination of the vitamins in pharmaceutical samples the values found agreed with those on the labels.  相似文献   

20.
A simple and reliable method has been established for determination of cis and trans-1,3-dichloropropene (1,3-DCP) in water by headspace solid-phase microextraction (HS-SPME) then GC–ECD. An experimental design with two steps was performed to determine the best experimental conditions for extraction of the 1,3-DCP isomers. First, a 26−2 fractional factorial design was conducted to screen for significant conditions. Second, a central composite design (CCD) was performed to optimise the variables. The best experimental extraction conditions were: polydimethylsiloxane–divinylbenzene (PDMS–DVB)-coated fibre, 20-min extraction time, 12 °C extraction temperature, 300 g L−1 NaCl, and 20 mL headspace volume in 40-mL vial. Under these conditions the method detection limit (MDL) was 0.5 ng L−1 for cis-1,3-DCP and 1.0 ng L−1 for trans-1,3-DCP. The method quantification limit (MQL) was 1.2 ng L−1 for cis-1,3-DCP and 3.0 ng L−1 for trans-1,3-DCP. For both isomers the relative standard deviation (RSD) for analysis of 50 ng L−1 or 0.5 μg L−1 of the isomer mixture was less than 8%. When the proposed method was applied to surface (river) water and tapwater samples from Gipuzkoa province (Spain) the target analytes were not detected. The method was also used to investigate the presence of the isomers in leachates from agricultural soil. A mixed solution was added to samples of two different soils and 1,3-DCP isomers were quantified in leachate obtained from the samples.  相似文献   