首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Kim KS  Park JK 《Lab on a chip》2005,5(6):657-664
This paper describes a novel microfluidic immunoassay utilizing binding of superparamagnetic nanoparticles to beads and deflection of these beads in a magnetic field as the signal for measuring the presence of analyte. The superparamagnetic 50 nm nanoparticles and fluorescent 1 microm polystyrene beads are immobilized with specific antibodies. When target analytes react with the polystyrene beads and superparamagnetic nanoparticles simultaneously, the superparamagnetic nanoparticles can be attached onto the microbeads by the antigen-antibody complex. In the poly(dimethylsiloxane)(PDMS) microfluidic channel, only the microbeads conjugated with superparamagnetic nanoparticles by analytes consequently move to the high gradient magnetic fields under the specific applied magnetic field. In this study, the magnetic force-based microfluidic immunoassay is successfully applied to detect the rabbit IgG and mouse IgG as model analytes. The lowest concentration of rabbit IgG and mouse IgG measured over the background is 244 pg mL(-1) and 15.6 ng mL(-1), respectively. The velocities of microbeads conjugated with superparamagnetic nanoparticles are demonstrated by magnetic field gradients in microfluidic channels and compared with the calculated magnetic field gradients. Moreover, dual analyte detection in a single reaction is also performed by the fluorescent encoded microbeads in the microfluidic device. Detection range and lower detection limit can be controlled by the microbeads concentration and the higher magnetic field gradient.  相似文献   

2.
基于具有优异表面增强拉曼散射(SERS)性能的石墨烯隔离的金纳米晶(GIAN)能够在水-有机相界面自组装, 待测物分子在有机相中的分配系数较大以及GIAN能够通过π?π相互作用与待测物分子结合的优势, 构建了激光介导的待测物分子的高效富集策略, 进而实现了9,10-双苯乙炔基蒽(BPEA)分子的痕量SERS分析. 所构建的新型待测物分子高效富集策略在一定程度上避免了因“咖啡环效应”带来的信号波动, 有望为复杂体系中痕量待测物的SERS分析提供可靠的平台.  相似文献   

3.
The application of high temperature comprehensive two-dimensional (2D) liquid chromatography for quantitative characterization of chemical composition and molecular weight (MW) heterogeneities in polyolefins is demonstrated in this study by separating a physical blend of isotactic-polypropylene, ethylene-random-propylene copolymer, and high density polyethylene. The first dimension separation is based on adsorption liquid chromatography that fractionates the blend from low to high ethylene content. The second dimension is size-exclusion chromatography connected with light scattering (LS) and infrared (IR) detectors. The IR detector shows desired sensitivity and linearity for monitoring analyte concentrations in the eluent after 2D separations. In addition, the compositions of the analytes are also determined from the ratio of two IR absorbances at the specified wavelength regions, an absorbance for measuring the level of methyl groups in polyolefins and another absorbance for measuring concentration. The LS detector is used to determine absolute molecular weight of the analytes from the ratio of the light scattering signal to the IR concentration signal. The ability to obtain concentration, chemical composition, and MW of polyolefins after 2D separation provides new opportunities to discover structure-property relationships for polyolefins with complex structures/architectures.  相似文献   

4.
We report the development and application of a capillary hollow fibre membrane interface using methanol as an acceptor phase to deliver target analytes to an electrospray ionization source and a triple quadrupole mass spectrometer. Superior fluid handling systems lead to greater signal stability and membrane integrity for the continuous on‐line monitoring of polar and charged analytes in complex aqueous samples with detection limits in the parts‐per‐trillion to parts‐per‐billion range. The system can be operated in either a continuous flow or a stopped acceptor flow mode – the latter giving rise to greater sensitivity. We report detection limits, enrichment factors and signal response times for selected analytes with polydimethylsiloxane and Nafion® polymer membrane interfaces. In addition, we demonstrate the use of this interface to detect pharmaceuticals and other contaminants in natural water and artificial urine. The improved sensitivity and analytical response times of our CP‐MIMS system make it possible to continuously monitor dynamic chemical systems with temporal resolutions on the order of minutes. Presented is a comparison of the performance of CP‐MIMS versus direct infusion electrospray ionization, demonstrating the potential advantages over direct infusion for trace analyte measurements in complex, high ionic strength samples. Furthermore, by continuously flowing a reaction mixture in a closed loop over the interface, we demonstrate the use of the system as an in situ reaction‐monitoring platform for the chlorination of a model organic compound in aqueous solution. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
In this study, corn stalk was used to synthesize a magnetic adsorbent by pyrolysis together with KHCO3 as the chemical activator and iron(III) salt as the magnetic reagent. The characterization by scanning electron microscopy, transmission electron microscopy and N2 adsorption–desorption analysis showed that the magnetic carbon adsorbent had a structure of hierarchical pores with a high specific surface area. To evaluate its adsorption performance, the adsorbent was used for the extraction of carbamates pesticides (propoxur, isoprocarb and fenobucarb) from water and zucchini samples before high‐performance liquid chromatography analysis. The result showed that the adsorbent had a good adsorption capability for the analytes. Under the optimized conditions, a good linearity for the analytes existed in the range of 0.1–100.0 ng/mL for water samples and 0.5–100.0 ng/g for zucchini samples with the correlation coefficients of 0.9992–0.9998. The limits of detection for the analytes at a signal to noise ratio of 3 were 0.03 ng/mL for water samples and 0.20–0.50 ng/g for zucchini samples.  相似文献   

6.
Some of the challenges with detection of ultra-low concentrations of analytes are to achieve sufficient sensitivity of the measurement and to direct the analyte species to the sensor (electrode) surface. This review describes various strategies that are available to address these challenges: method of electrocatalytic amplification, electrochemical measurements performed in combination with electrokinetic preconcentration of analytes, ultra-sensitive analysis utilizing increased surface area and also the manipulation by the magnetic force.  相似文献   

7.
Laser‐diode thermal desorption (LDTD) is an ionization source usually coupled to triple quadrupole mass spectrometry (QqQMS) and specifically designed for laboratories requiring high‐throughput analysis. It has been observed that surface coatings on LDTD microwell plates can improve the sensitivity of the analysis of small polar molecules. The objective of the present study is to understand and quantify the effect of microwell surface coatings on signal intensity of small organic molecules of clinical, environmental, and forensic interest. Experiments showed that the peak areas of diclofenac, chloramphenicol, salicylic acid, and 11‐nor‐9‐carboxy‐Δ9‐tetrahydrocannabinol obtained by LDTD‐QqQMS increased by up to 3 orders of magnitude when using microwells coated with ethylenediaminetetraacetic acid (EDTA). Tests with different chelating agents and polytetrafluoroethylene as microwell surface coatings showed that nitrilotriacetic acid gave significantly higher peak areas for five out of the nine compounds that showed signal enhancement using chelating agents as coatings. Scanning electron microscopy studies of EDTA‐coated and uncoated microwells showed that analytes deposited in the former formed more uniform and thinner films than in the latter. The enhancement effect of surface coatings in LDTD‐QqQMS was explained mainly by the formation of homogenous and thinner layers of nanocrystals of analytes that are easier to desorb thermally than the layers formed when the analytes dry in direct contact with the bare stainless‐steel surface. Chemisorption of some analytes to the stainless‐steel surface of the microwell plate appeared to be a minor factor. Surface coatings widen the number of compounds analyzable by LDTD‐QqQMS and can also improve sensitivity and limits of detection.  相似文献   

8.
The effect of surface activity in surface-assisted laser desorption/ionization (SALDI) mass spectrometry was examined. Several surfactants, including p-tolunensulfonic acid (PTSA), sodium dodecyl sulfate and alkyltrimethylammonium bromide, were used as analytes or additives in the SALDI matrix to demonstrate the surface activity effect. The experimental results demonstrate that analytes that have good surface activity have good sensitivity. Adding suitable amounts of surfactants to the SALDI matrix can dramatically enhance the sensitivity of analytes lacking surface activity. We propose that the enhancement of analyte signals is due to the ionic interaction between ionic surfactants and analytes because non-ionic surfactant additives in the SALDI matrix do not affect the analyte signals. The detection limit of methylephedrine can be as low as 100 pg in the SALDI analysis of 0.5 M PTSA additive in the SALDI matrix. Although other surfactants can also be used as matrix additives to enhance the analyte signal, they do not improve the ion abundance as much as PTSA does.  相似文献   

9.
In this work, a low‐pressure air dielectric‐barrier discharge (DBD) ion source using a capillary with the inner diameter of 0.115 and 12 mm long applicable to miniaturized mass spectrometers was developed. The analytes, trinitrotoluene (TNT), 1,3,5‐trinitroperhydro‐1,3,5‐triazine (RDX), 1,3,5,7‐tetranitroperhydro‐1,3,5,7‐tetrazocine (HMX), pentaerythritol tetranitrate (PETN), nitroglycerine (NG), hexamethylene triperoxide diamine (HMTD), caffeine, cocaine and morphine, introduced through the capillary, were ionized by a low‐pressure air DBD. The ion source pressures were changed by using various sizes of the ion sampling orifice. The signal intensities of those analytes showed marked pressure dependence. TNT was detected with higher sensitivity at lower pressure but vice versa for other analytes. For all analytes, a marked signal enhancement was observed when a grounded cylindrical mesh electrode was installed in the DBD ion source. Among nine analytes, RDX, HMX, NG and PETN could be detected as cluster ions [analyte + NO3]? even at low pressure and high temperature up to 180 °C. The detection indicates that these cluster ions are stable enough to survive under present experimental conditions. The unexpectedly high stabilities of these cluster ions were verified by density functional theory calculation. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
Urine samples obtained from drug abusers were screened for drugs of abuse and their metabolites using DESI-MS and the results obtained were compared to results obtained from GC-MS experiments. The detected analyte classes included amphetamines, opiates, cannabinoids and benzodiazepines. The compounds detected were codeine, morphine, oxymorphone, 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol, Delta(9)-tetrahydrocannabinol, alprazolam, temazepam, oxazepam, N-desmethyldiazepam (nordiazepam) and hydroxytemazepam. Identities of all the analytes were confirmed by tandem mass spectrometry, matching MS/MS spectra with authentic standard compounds. The concentrations of the analytes in the samples were obtained from semi-quantitative GC-MS studies and were in the range of 270-22,000 ng mL(-1). The analytes could be detected by DESI even after a hundred-fold dilution indicating that the sensitivity of DESI was more than adequate for this study. Selectivity in the DESI-MS measurements for different kinds of analytes could be increased further by optimizing the spray solvent composition: the use of an entirely aqueous solvent enhanced the signal of polar analytes, such as the benzodiazepines, whereas the use of a spray solvent with a high organic content increased the signal of less polar analytes, such as codeine and morphine.  相似文献   

11.
In the past decade, Ion Mobility Spectrometry has established a very strong foot hold in medical and biological applications due to its numerous advantages including sensitivity, ruggedness and reproducibility. During the analysis of complex samples such as human breath, it is very probable that two or more analytes form peak clusters due to similar drift times and pre-separation times, thus hindering the identification of the analytes. Furthermore, such overlapping of signal makes quantification very difficult or even impossible. Resolving these peak clusters is important to enable proper identification and quantification of analytes detected for diagnosis. Hence, we designed a drift tube with variable length for investigating the influence of varying drift lengths and electric field on resolution. Peak cluster formations usually seen between acetone and the reactant ion peak, between the dimer peaks of 2-Heptanone and 4-Heptanone have been resolved with the new drift tube after optimisation. These novel drift tubes could easily negate the peak clusters often encountered when complex medical and biological samples are measured with the ion mobility spectrometer. Furthermore, the fact that these drift tubes can be altered in length thereby providing a wide range of electric fields (from 50 to 3300 V.cm−1), opens up new research options in ion motions in an electric field.  相似文献   

12.
3D plasmonic colloidosomes are superior SERS sensors owing to their high sensitivity and excellent tolerance to laser misalignment. Herein, we incorporate plasmonic colloidosomes in a microfluidic channel for online SERS detection. Our method resolves the poor signal reproducibility and inter-sample contamination in the existing online SERS platforms. Our flow system offers rapid and continuous online detection of 20 samples in less than 5 min with excellent signal reproducibility. The isolated colloidosomes prevent cross-sample and channel contamination, allowing accurate quantification of samples over a concentration range of five orders of magnitude. Our system demonstrates high-resolution multiplex detection with fully preserved signal and Raman features of individual analytes in a mixture. High-throughput multi-assay analysis is performed, which highlights that our system is capable of rapid identification and quantification of a sequence of samples containing various analytes and concentrations.  相似文献   

13.
Magnetorelaxometry measurements on suspensions of magnetic beads are demonstrated using a planar Hall effect sensor chip embedded in a microfluidic system. The alternating magnetic field used for magnetizing the beads is provided by the sensor bias current and the complex magnetic susceptibility spectra are recorded as the 2nd harmonic of the sensor response. The complex magnetic susceptibility signal appears when a magnetic bead suspension is injected, it scales with the bead concentration, and it follows the Cole-Cole expression for Brownian relaxation. The complex magnetic susceptibility signal resembles that from conventional magnetorelaxometry done on the same samples apart from an offset in Brownian relaxation frequency. The time dependence of the signal can be rationalized as originating from sedimented beads.  相似文献   

14.
The effect of liquid chromatography separation on liquid chromatography-tandem mass spectrometry (LC-MS-MS) signal response for the characterization of low-molecular-mass compounds in a complex matrix was investigated. Matrix induced signal suppression appears throughout the entire LC-MS-MS analysis of wheat forage extract, with greatest suppression occurring at early retention times. Experimental results show that co-elution of matrix components and analytes from the LC column may be most strongly attributed to column overloading rather than similar analyte and matrix retention behavior. As a result, two-dimensional (LC-LC) separation can be a highly effective approach to address signal suppression effects for the quantitative LC-MS-MS analysis of complex matrix samples.  相似文献   

15.
3D plasmonic colloidosomes are superior SERS sensors owing to their high sensitivity and excellent tolerance to laser misalignment. Herein, we incorporate plasmonic colloidosomes in a microfluidic channel for online SERS detection. Our method resolves the poor signal reproducibility and inter‐sample contamination in the existing online SERS platforms. Our flow system offers rapid and continuous online detection of 20 samples in less than 5 min with excellent signal reproducibility. The isolated colloidosomes prevent cross‐sample and channel contamination, allowing accurate quantification of samples over a concentration range of five orders of magnitude. Our system demonstrates high‐resolution multiplex detection with fully preserved signal and Raman features of individual analytes in a mixture. High‐throughput multi‐assay analysis is performed, which highlights that our system is capable of rapid identification and quantification of a sequence of samples containing various analytes and concentrations.  相似文献   

16.
In recent years, the sensor array has attracted much attention in the field of complex system analysis on the basis of its good selectivity and easy operation. Many optical colorimetric sensor arrays are designed to analyze multi-target analytes due to the good sensitivity of optical signal. In this review, we introduce the targeting analytes, sensing mechanisms and data processing methods of the optical colorimetric sensor array based on optical probes (including organic molecular probes, polymer materials and nanomaterials). The research progress in the detection of metal ions, anions, toxic gases, organic compounds, biomolecules and living organisms (such as DNA, amino acids, proteins, microbes and cells) and actual sample mixtures are summarized here. The review illustrates the types, application advantages and development prospects of the optical colorimetric sensor array to help broad readers to understand the research progress in the application of chemical sensor array.  相似文献   

17.
An electrospray interface is described that provides high sensitivity and signal stability for mass spectrometric detection of analytes in solvents with high water content including 100% water. The electrospray capillary tip section is heated close to the boiling point of the solvent. An approximately 20°C hotter airstream, with flow coaxial to the electrospray tip and codirectional to the electrospray.. is also used. With this arrangement, the analyte signal sensitivity and stability obtained with neat water is equal to that obtained with neat methanol. The heated electrospray also affords the use of a wide range of flow rates: 1–100 μL/min.  相似文献   

18.
Huang Y  Zhao S  Shi M  Liu J  Liang H 《Electrophoresis》2012,33(7):1198-1204
A facile and universal strategy for multiplexed immunoassay is proposed. The strategy is based on microchip electrophoresis (MCE) coupled with on-line magnetic separation and chemiluminescence (CL) detection. The system consisted of a microchip, an electromagnet, and a photomultiplier. The realization of multiplexed immunoassay protocol involves sampling magnetic nanoparticles (MNPs) labeled antibodies, N-(4-aminobutyl)-N-ethyl-isoluminol (ABEI) labeled antigens and free antigens in the precolumn reactor, on-line immunoreaction, capturing the MNPs-immunocomplexes, and the separation of unconjugated ABEI-labeled antigens. After on-line magnetic separation, the free ABEI-labeled antigens were transported into the separation channel, and mixed with hydrogen peroxide (H(2) O(2) ) in the presence of horseradish peroxidase in the postcolumn reactor, and producing CL emission. Using this arrangement, multiple analytes could be measured simultaneously by performing the technical operations for a single assay. As a proof-of-concept, the multiplexed immunoassay was evaluated for the simultaneous determination of five model analytes (i.e. hydrocortisone, corticosterone, digoxin, testosterone, and estriol). The results exhibited excellent precision and sensitivity, the relative standard deviations for nine times detection were lower than 4.7% for all the five components, and the detection limits of five analytes were in the range of 3.6-4.9 nM. The MCE system was validated using two human serum-based control samples containing five analytes.  相似文献   

19.
Due to their unique properties, such as programmability, ligand-binding capability, and flexibility, nucleic acids can serve as analytes and/or recognition elements for biosensing. To improve the sensitivity of nucleic acid-based biosensing and hence the detection of a few copies of target molecule, different modern amplification methodologies, namely target-and-signal-based amplification strategies, have already been developed. These recent signal amplification technologies, which are capable of amplifying the signal intensity without changing the targets’ copy number, have resulted in fast, reliable, and sensitive methods for nucleic acid detection. Working in cell-free settings, researchers have been able to optimize a variety of complex and quantitative methods suitable for deploying in live-cell conditions. In this study, a comprehensive review of the signal amplification technologies for the detection of nucleic acids is provided. We classify the signal amplification methodologies into enzymatic and non-enzymatic strategies with a primary focus on the methods that enable us to shift away from in vitro detecting to in vivo imaging. Finally, the future challenges and limitations of detection for cellular conditions are discussed.  相似文献   

20.
Cheng D  Guo Y  Hsing IM 《The Analyst》2012,137(4):999-1004
In this study, we report a new immunoassay platform based on yeast surface display technology for detection of autoantibodies involved in autoimmune diseases, e.g., systemic lupus erythematosus (SLE) and Sj?gren's syndrome (SS). The autoantigens of Ro52/SSA epitope and SmD were chosen to be displayed on the yeast surface with their respective antibodies as the analytes. By using magnetic beads modified with protein G, yeast cells bound with specific target antibody can be captured. The amount of analytes could be determined by counting the number of fluorescent yeast cells captured in a magnetic field. The platform showed promising results in the detection of SLE autoantibodies with high sensitivity and multiplex detection capability over the traditional approaches.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号