首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 26 毫秒
1.
研究了钛及钛合金的气体标准试样制备工艺和数据处理方案,对标准试样长期考察的结果。证明了它的准确性,稳定性是令人满意的。适用于氢氧分析仪器的校准和分析的验证。  相似文献   

2.
The thorough analysis of natural nanoparticles (NPs) and engineered NPs involves the sequence of detection, identification, quantification and, if possible, detailed characterization. In a complex or heterogeneous sample, each step of this sequence is an individual challenge, and, given suitable sample preparation, field-flow fractionation (FFF) is one of the most promising techniques to achieve relevant characterization.The objective of this review is to present the current status of FFF as an analytical separation technique for the study of NPs in complex food and environmental samples. FFF has been applied for separation of various types of NP (e.g., organic macromolecules, and carbonaceous or inorganic NPs) in different types of media (e.g., natural waters, soil extracts or food samples).FFF can be coupled to different types of detectors that offer additional information and specificity, and the determination of size-dependent properties typically inaccessible to other techniques. The separation conditions need to be carefully adapted to account for specific particle properties, so quantitative analysis of heterogeneous or complex samples is difficult as soon as matrix constituents in the samples require contradictory separation conditions. The potential of FFF analysis should always be evaluated bearing in mind the impact of the necessary sample preparation, the information that can be retrieved from the chosen detection systems and the influence of the chosen separation conditions on all types of NP in the sample. A holistic methodological approach is preferable to a technique-focused one.  相似文献   

3.
The objective of this work was to develop a sample preparation procedure for determination of the carbohydrate profiles in commercial juice samples by three principally different analytical methods: capillary electrophoresis (CE) with indirect detection, high-performance liquid chromatography (HPLC), and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The preparation and purification of juice samples prior to analysis is described. The method using Carrez reagents was found to be an efficient preparation tool for all three methods. The addition of Carrez reagents to the samples for mass analysis improved the quality of the mass spectra of oligosaccharides. The amounts of glucose, fructose, and sucrose as major carbohydrates in fruit juices measured by CE using a simple instrument are in good agreement with the HPLC values and the data declared by the producers of the juices. The results from both methods are critically evaluated and their impact for studies of authenticity is discussed. The decrease of sucrose amount during the storage of samples was explained by acid hydrolysis of this disaccharide.  相似文献   

4.
讨论了不同物理和化学制样方法对钢中氧、氮测定结果的影响。试验结果表明,物理制样采用锉刀打磨样品表面后剪切,再用乙醚清洗除去油污;化学制样先用20%盐酸溶液溶解样品表面氧化层,再用滴加了4滴30%过氧化氢的10%草酸溶液浸泡,取出后依次用水、无水乙醇浸洗,风干。用以上两种方法制样,钢标准样品中氧、氮含量测定值与标示值一致。在测定钢中氮含量时,可用乙醚清洗后直接测定,以缩短检测周期和减轻劳动强度。该研究结果可用于指导钢样品中氧、氮含量测定时样品的处理。  相似文献   

5.
UV filters are a group of compounds commonly used in different cosmetic products to absorb UV radiation. They are classified into a variety of chemical groups, such as benzophenones, salicylates, benzotriazoles, cinnamates, p-aminobenzoates, triazines, camphor derivatives, etc. Different tests have shown that some of these chemicals are absorbed through the skin and metabolised or bioaccumulated. These processes can cause negative health effects, including mutagenic and cancerogenic ones. Due to the absence of official monitoring protocols, there is an increased number of analytical methods that enable the determination of those compounds in cosmetic samples to ensure user safety, as well as in biological fluids and tissues samples, to obtain more information regarding their behaviour in the human body. This review aimed to show and discuss the published studies concerning analytical methods for the determination of organic UV filters in cosmetic and biological samples. It focused on sample preparation, analytical techniques, and analytical performance (limit of detection, accuracy, and repeatability).  相似文献   

6.
Emissions of volatiles of polymeric materials are an important parameter for materials characterisation, and gain more and more importance either by their odour activity or by other undesired behaviour. Currently, numerous methods are applied for the determination of volatiles, but all of them use gas chromatography (GC) with different detectors. The information gained by flame ionisation detection (FID) is the total emitted volatiles expressed as a sum value, but no further deeper information is provided. Additionally, due to different sample amounts, preparation, way of sampling and GC parameters, results cannot be compared to each other. Also, determination of single sum values by integrating the total area of volatiles is of little help for material development due to the lack of detailed information about chemical composition, and other methods have to be applied. Other compounds of interest such as odour-active ones turn up in only very small amounts and cannot be detected by these methods as an extensive analytical sample preparation is necessary. We compare results obtained by different sample preparation techniques used in industrial standards (VDA 277 and VDA278) to scientific alternatives such as Solid Phase Microextraction (SPME) coupled to GC with mass spectrometry (MS) and Simultaneous Distillation/Extraction SDE coupled to GC-MS to demonstrate capabilities and applicability of each method.  相似文献   

7.
This paper describes the development of various new acid sample decomposition methods, as well as an extraction (leaching) method and compares them with the “Sch?niger Combustion” technique. The methods have been developed as sample preparation techniques for iodine determination in biological materials, especially in solid samples. ICP-MS (inductively coupled plasma mass spectrometry) and a catalytic technique are employed and discussed for the final determination of iodine concentrations. Accuracy and reliability of the different analytical methods are shown in the examples of different CRMs (certified reference materials) available for iodine. The results of an interlaboratory comparison are specifically presented for the extraction (leaching) method. Received: 11 May 1998 / Revised: 14 June 1998 / Accepted: 16 June 1998  相似文献   

8.
对脉冲加热-红外吸收法测定钒铝合金中氢的分析方法进行了研究。通过实验对分析功率、称样量和校正标样等测试条件进行了讨论。实验表明钒铝合金中的氢易释放,对于AlV85样品中氢,热提取法和熔融法测定结果一致;但AlV50样品中氢,热提取法的结果略高于熔融法,故实验中选用热提取法测定钒铝合金中氢量。热提取法用0.75g金属锡作助熔剂,于4.0kW分析功率条件下测定钛标准样品中氢来确定氢工作曲线的校正系数,在1.5kW分析功率下测定钒铝合金中氢,测定结果与高频感应-热导法(用5g钢标准样品对氢的测定进行校正)结果吻合。对3个钒铝合金中氢量进行了测定,结果的相对标准偏差为2.2%~6.5%(n=8)。  相似文献   

9.
Rokuro-Kuroda  Mochizuki T 《Talanta》1981,28(6):389-393
Flow-injection methods have been developed for the determination of copper, nickel and zinc in copper-base alloys, including several types of brasses, deoxidized copper, beryllium copper and German silver. The system for copper and nickel involves the measurement of the absorbance of the copper(II) and nickel(II) aquo-complexes at 805 and 410 nm, respectively, after simple dissolution of the sample in a nitric acid-phosphoric acid mixture. The system needs no further reagents and the sample solutions can be analysed at rates of up to 280 /hr for copper (or nickel in German silver) without any carry-over. The system for zinc consists of automatic dilution of the injected sample with a thiosulphate-acetate buffer solution and the subsequent measurement of the absorbance of the zinc-Xylenol Orange complex at 568 nm. This system permits analysis rates of up to 90/hr for zinc solutions, with no carry-over. The procedures have been applied to standard copper-base alloys. The results agreed satisfactorily with the certified values. The precision ranges are 0.2-0.7% for copper and nickel and 0.5-0.8% for zinc.  相似文献   

10.
The measurement of low levels of organic compounds in environmental samples presents the researcher with a number of possible pathways to effectively obtain and analyze samples. Numerous sampling methods, sample preparation techniques, and extraction procedures are available. A number of different approaches to sampling strategy, isolation, concentration, cleanup and fractionation will be discussed. Objectives for collecting environmental samples differ from those for many other types of samples because reliable measurements at very low levels are frequently required. Often, specific analytes need to be measured at the μg/kg and even ng/kg levels in complex matrices. Advances in analytical methodology continue to lower the levels at which reliable measurements can be made. At these levels, many factors that are of little or no concern in other analytical measurements are of critical importance in influencing the outcome and reliability of environmental analyses. Analytical measurements are used for determining the composition and the quantities of analytes in the defined system at various concentration levels. Environmental analytical measurements provide data about the transportation and transformation of an environmental contraminant and for determination of its concentration in a sample.  相似文献   

11.
Differential kinetic analysis can be implemented in a multi-pumping flow system, and this was demonstrated in relation to an improved spectrophotometric catalytic determination of iron and vanadium in Fe-V alloys. The method exploited the influence of Fe(II) and V(IV) on the rate of iodide oxidation by Cr(VI) under acidic conditions; therefore the Jones reductor was needed. The sample was inserted into an acidic KI stream that acted also as carrier stream, and a Cr(VI) solution was added by confluence. Successive measurements were performed during sample passage through the detector, each one related to a different yet reproducible condition for reaction development. Data treatment involved multivariate calibration by the PLS algorithm.The proposed system is very simple and rugged, allowing about 50 samples to be run per hour, meaning 48 mg KI per determination. The first two latent variables carry ca. 94% of the analytical information, pointing out that the intrinsic dimensionality of the data set is two. Results are in agreement with inductively coupled argon plasma-optical emission spectrometry.  相似文献   

12.
Sample preparation is always the major bottleneck in analytical chemistry for the determination of pesticide residues. Different sample preparation methods have been proposed due to the wide variety of pesticides used and the inherent complexity of the matrices. In this study, different sample preparation methods including SPE, matrix solid‐phase dispersion, the quick, easy, cheap, efficient, rugged, and safe method, and a one‐step completion method were compared and evaluated for extracting pesticides from lotus seeds. Analysis was carried out using GC with electron‐capture detection. The results showed that good recoveries for tested pesticides were obtained by using Florisil in the four methods, and the extraction efficiency of the one‐step completion method was superior to the other three methods. The one‐step completion method was confirmed to have good linearity, reproducibility, stability, and recovery for the detection of 36 pesticides in lotus seed samples. The data collected from this study are expected to prove useful in regulating the concentration of the residues in lotus seeds, as well as in protecting human health from the hazards posed by these residues.  相似文献   

13.
Effectiveness of Pd/Mg chemical modifier for the accurate direct determination of zinc in marine/lacustrine sediments by graphite furnace atomic absorption spectrometry (GF-AAS) using slurry samples was evaluated. A calibration curve prepared by aqueous zinc standard solution with addition of Pd/Mg chemical modifier is used to determine the zinc concentration in the sediment. The accuracy of the proposed method was confirmed using Certified Reference Materials, NMIJ CRM 7303-a (lacustrine sediment) from National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Japan, and MESS-3 (marine sediment) and PACS-2 (marine sediment) from National Research Council, Canada. The analytical results obtained by employing Pd/Mg modifier are in good agreement with the certified values of all the reference sediment materials. Although for NRC MESS-3 an accurate determination of zinc is achieved even without the chemical modifier, the use of Pd/Mg chemical modifier is recommended as it leads to establishment of a reliable and accurate direct analytical method. One quantitative analysis takes less than 15 minutes after we obtain dried sediment samples, which is several tens of times faster than conventional analytical methods using acid digested sample solutions. The detection limits are 0.13?µg?g?1 (213.9?nm) and 16?µg?g?1 (307.6?nm), respectively, in sediment samples, when 40?mg of dried powdered samples are suspended in 20?mL of 0.1?mol?L?1 nitric acid and a 10?µl portion of the slurry sample is measured. The precision of the proposed method is 8–15% (RSD).  相似文献   

14.
针对光纤级高纯四氯化锗(99.999999%)中痕量含氢杂质吸收峰红外透过率检测(FTIR)用试样的采集,以及痕量金属杂质的电感耦合等离子体质谱法(ICP-MS)测定用试样的制备方法进行了系统研究。设计开发了用于检测痕量含氢杂质吸收峰红外透过率的样品采集实验装置,实现了含氢杂质(如—OH、—CH、HCl等)吸收峰的红外透过率在线连续测试,试样采集过程全密闭进行,避免了采样过程的二次污染,采样过程流程简短,操作简便;实验优选了在制备ICP-MS法测定痕量金属杂质用的试样过程中消除四氯化锗基体干扰、防止砷等易挥发杂质损失以及防止样品处理过程污染试样的制样方法,实现了试样制备过程二次污染源的有效控制,制样过程试剂消耗量少,制备时间短,待测元素无损失。  相似文献   

15.
Abstract

For the determination of minute amounts of elements in environmental samples combined analytical procedures are frequently employed. The combination of suitable sample preparation techniques with adequate detection methods lead to powerful analytical procedures. Decomposition methods are an important part of combined procedures for the determination of trace elements in solid samples. After a short summary of the potential sources for systematic errors two new decomposition methods are described that are suitable for the ashing of organic environmental samples. In one method the organic sample is ashed in a high-frequency excited oxygen plasma. The second method is a high pressure decomposition that permits mineralization of the sample in sealed quartz vessels with nitric acid at temperatures up to 320°C.

For both methods the ratio of sample weight to decomposition reagents is comparatively high. This makes these methods in combination with adequate detection methods suitable for the determination of elements at very low concentrations.

X-ray fluorescence spectrometry combined with adequate preconcentration methods is very well suited for the simultaneous determination of trace elements. Following a critical evaluation of various preconcentration techniques the analytical characteristics of filter paper with immobilized complexing agents are described. Particular emphasis is given to filter papers with dithiocarbamates as chelating group.  相似文献   

16.
Sample preparation frequently is considered the most critical stage of the analytical workflow. It affects the analytical throughput and costs; moreover, it is the primary source of error and possible sample contamination. To increase efficiency, productivity, and reliability, while minimizing costs and environmental impacts, miniaturization and automation of sample preparation are necessary. Nowadays, several types of liquid-phase and solid-phase microextractions are available, as well as different automatization strategies. Thus, this review summarizes recent developments in automated microextractions coupled with liquid chromatography, from 2016 to 2022. Therefore, outstanding technologies and their main outcomes, as well as miniaturization and automation of sample preparation, are critically analyzed. Focus is given to main microextraction automation strategies, such as flow techniques, robotic systems, and column-switching approaches, reviewing their applications to the determination of small organic molecules in biological, environmental, and food/beverage samples.  相似文献   

17.
Using naphthidine as an internal indicator in the titration of zinc with standard potassium ferrocyanide solutions, suitable procedures are recommended for the determination of zinc in various non-ferrous alloys and in rubber ashes. With aluminium alloys, aluminium bronzes and white metals the zinc is separated from interfering elements by hydrogen sulphide procedures, whereas with tin bronzes the separation is best accomplished by an 8-hydroxyquinoline procedure. After the solution of rubber ashes in hydrochloric acid, the major interfering elements are removed from the zinc by filtration after making the solution ammoniacal. With samples giving large precipitates with ammonia, it is necessary to redissolve them and determine the entrained traces of zinc.  相似文献   

18.
Polybrominated diphenyl ethers (PBDEs) are a group of persistent organic pollutants. They are used as flame retardants in plastics, paints, varnishes and textile materials. PBDEs pose great risk to the environment because of their high persistence and ability to get into the environment easily due to the lack of chemical bonds with the matrix of materials, to which they are added. Global research studies confirmed the occurrence of those compounds in the majority of elements of water and land environment. Analysis of PBDEs in environmental samples is one of the specific analytical methods of criteria that comprise low detection limits and high selectivity. The analysis of PBDEs in environmental samples is one of the specific analytical methods, in which the main criteria are low detection limits and high selectivity. In this article, a literature review of methods for environmental sample preparation and analysis of the PBDE content was presented. The article discusses the potential of modern extraction techniques such as: solid-phase microextraction, single-drop microextraction, dispersive liquid-liquid microextraction, microwave-assisted extraction, cloud point extraction, hollow fibre-liquid phase microextraction and others for the separation of PBDEs from environmental samples with a complex matrix. Among the methods for qualitative and quantitative determination of PBDEs, a particular focus was put on gas chromatography/mass spectrometry with various injection techniques and different types of sample ionisation.  相似文献   

19.
Rodushkin I  Axelsson MD  Burman E 《Talanta》2000,51(4):743-759
The combination of inductively coupled plasma atomic emission spectrometry and high resolution inductively coupled plasma mass spectrometry for the determination of 70 elements in coal were studied. Four microwave-assisted digestion procedures with different dissolution mixtures (nitric and hydrofluoric acids, aqua regia and hydrogen peroxide), lithium metaborate fusion with and without previous sample ashing as well as direct sampling by laser ablation (LA) have been tested. Examples of spectral interferences are given and different correction procedures are discussed. Detection limits in the low ng g(-1) range were obtained for most of the elements investigated by using high-purity reagents and by taking special care to prevent sample contamination during preparation. The precision was assessed from replicate analysis (including sample preparation) of coal samples and was found to be, as average values far all elements, 4-5% RSD and 10-15% RSD for procedures including sample digestion and LA sampling, respectively. The accuracy of the overall analytical procedures was estimated by analysis of certified reference materials and of a coal sample obtained from the Interlab Trace round robin test. Among the dissolution mixtures tested, the combination of nitric and hydrofluoric acids with hydrogen peroxide provide the best agreement with certified, recommended, literature-compiled or consensus values, though fusion is necessary to obtain quantitative recoveries for Si, Cr, Hf, W, Zr, Y. In general, results obtained by LA fall within +/-20% of those obtained after digestion.  相似文献   

20.
In this review sample preparation strategies used for crude oil digestion in last ten years are discussed focusing on further metals and non-metals determination. One of the main challenges of proposed methods has been to overcome the difficulty to bring crude oil samples into solution, which should be compatible with analytical techniques used for element determination. On this aspect, this review summarizes the sample preparation methods for metals and non metals determination in crude oil including those based on wet digestion, combustion, emulsification, extraction, sample dilution with organic solvents, among others. Conventional methods related to wet digestion with concentrated acids or combustion are also covered, with special emphasis to closed systems. Trends in sample digestion, such as microwave-assisted digestion using diluted acids combined with high-efficiency decomposition systems are discussed. On the other hand, strategies based on sample dilution in organic solvents and procedures recommended for speciation analysis are reported as well as the use of direct analysis in view of the recent importance for crude oil field. A compilation concerning sample preparation for crude oil provided by official methods as well as certified reference materials available for accuracy evaluation is also presented and discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号