首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Solid-phase extraction (SPE) columns packed with materials based on molecularly imprinted polymers (MIPs) were used to develop selective separation and preconcentration for Ni(II) ion from aqueous solutions. SPE is more rapid, simple and economical method than the traditional liquid-liquid extraction. MIPs were used as column sorbent to increase the grade of selectivity in SPE columns. In this study, we have developed a polymer obtained by imprinting with Ni(II) ion as a ion-imprinted SPE sorbent. For this purpose, NI(II)-methacryloylhistidinedihydrate (MAH/Ni(II)) complex monomer was synthesized and polymerized with cross-linking ethyleneglycoldimethacrylate to obtain [poly(EGDMA-MAH/Ni(II))]. Then, Ni(II) ions were removed from the polymer getting Ni(II) ion-imprinted sorbent. The MIP-SPE preconcentration procedure showed a linear calibration curve within concentration range from 0.3 to 25 ng/ml and the detection limit was 0.3 ng/ml (3 s) for flame atomic absorption spectrometry (FAAS). Ni(II) ion-imprinted microbeads can be used several times without considerable loss of adsorption capacity. When the adsorption capacity of nickel imprinted microbeads were compared with non-imprinted microbeads, nickel imprinted microbeads have higher adsorption capacity. The Kd (distribution coefficient) values for the Ni(II)-imprinted microbeads show increase in Kd for Ni(II) with respect to both Kd values of Zn(II), Cu(II) and Co(II) ions and non-imprinted polymer. During that time Kd decreases for Zn(II), Cu(II) and Co(II) ions and the k′ (relative selectivity coefficient) values which are greater than 1 for imprinted microbeads of Ni(II)/Cu(II), Ni(II)/Zn(II) and Ni(II)/Co(II) are 57.3, 53.9, and 17.3, respectively. Determination of Ni(II) ion in sea water showed that the interfering matrix had been almost removed during preconcentration. The column was good enough for Ni determination in matrixes containing similar ionic radii ions such as Cu(II), Zn(II) and Co(II).  相似文献   

2.
A new Fe(III)-imprinted amino-functionalized silica gel sorbent was prepared by a surface imprinting technique for selective solid-phase extraction (SPE) of Fe(III) prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Compared with non-imprinted polymer particles, the ion-imprinted polymers (IIPs) had higher selectivity and adsorption capacity for Fe(III). The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Fe(III) was 25.21 and 5.10 mg g−1, respectively. The largest selectivity coefficient of the Fe(III)-imprinted sorbent for Fe(III) in the presence of Cr(III) was over 450. The relatively selective factor (αr) values of Fe(III)/Cr(III) were 49.9 and 42.4, which were greater than 1. The distribution ratio (D) values of Fe(III)-imprinted polymers for Fe(III) were greatly larger than that for Cr(III). The detection limit (3σ) was 0.34 μg L−1. The relative standard deviation of the method was 1.50% for eight replicate determinations. The method was validated by analyzing two certified reference materials (GBW 08301 and GBW 08303), the results obtained is in good agreement with standard values. The developed method was also successfully applied to the determination of trace iron in plants and water samples with satisfactory results.  相似文献   

3.
A novel Rh(III)-imprinted amino-functionalised silica gel sorbent was prepared by a surface imprinting technique for preconcentration and separation of Rh(III) prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Compared with the traditional solid sorbents and non-imprinted polymer particles, the ion-imprinted polymers (IIPs) had higher adsorption capacity and selectivity for Rh(III). The maximum static adsorption capacity of the imprinted and non-imprinted sorbent for Rh(III) was 29.86?mg?g?1 and 11.23?mg?g?1, respectively. The imprinted Rh(III) was removed with 2?mL of 3% thiourea?+?2?mol?L?1 HCl. The obtained imprinted particles exhibited excellent selectivity and rapid kinetics process for Rh(III). The relatively selective factor (αr) values of Rh(III)/Ru(III), Rh(III)/Au(III), Rh(III)/Pt(IV), Rh(III)/Ir(IV), Rh(III)/Pd(II) were 26.7, 39.0 29.2, 28.1, 43.7, respectively, which were greater than 1. The detection limit (3σ) of the method was 0.26?µg?L?1. The relative standard deviation of the method was 1.79% for eight replicate determination of 10?µg of Rh3+ in 200?mL water sample. The method was validated by analysing standard reference material (GBW 07293), the results obtained is in good agreement with standard values. The developed method was also successfully applied to the determination of trace rhodium(III) in geological samples with satisfactory results.  相似文献   

4.
A new Cu(II) ion-imprinted sorbent was synthesized by a surface imprinting technique and characterized by FT-IR and SEM. Compared to the non-imprinted sorbent, the Cu(II) ion-imprinted sorbent had a higher adsorption capacity and selectivity for Cu(II). The static adsorption capacity of the Cu(II) ion-imprinted sorbent and non-imprinted sorbent for Cu(II) were 84.5 and 46.5 μmol?g?1, respectively. The best selectivity coefficient over Zn(II) or Cd(II) ion was over 12. The relative selectivity coefficients of the sorbent for Cu(II) in the presence of Zn(II) and Cd(II) were 13 and 35, respectively. Furthermore, the new sorbent possessed a fast kinetics for Cu(II) sorption from aqueous solution with saturation time of <30 min, and could be used repeatedly. The standard deviation for 11 replicate determinations of 0.5 mg?L?1 Cu(II) was 0.8%. This new Cu(II) ion-imprinted sorbent can be used as an effective solid-phase extraction material for the selective preconcentration and separation of Cu(II).  相似文献   

5.
Xiaoman Jiang  Mancang Liu 《Talanta》2007,72(1):119-125
A novel and simple imprinted amino-functionalized silica gel material was synthesized by combining a surface molecular imprinting technique with a sol-gel process on the supporter of activated silica gel for solid-phase extraction-high performance liquid chromatography (SPE-HPLC) determination of bisphenol A (BPA). Non-imprinted silica sorbent was synthesized without the addition of BPA using the same procedure as that of BPA-imprinted silica sorbent. The BPA-imprinted silica sorbent and non-imprinted silica sorbent were characterized by FT-IR and the static adsorption experiments. The prepared BPA-imprinted silica sorbent showed high adsorption capacity, significant selectivity and good site accessibility for BPA. The maximum static adsorption capacity of the BPA-imprinted and non-imprinted silica sorbent for BPA was 68.9 and 34.0 mg g−1, respectively. The relatively selective factor value of this BPA-imprinted silica sorbent was 4.5. Furthermore, the difference of the retention characteristics of BPA on the C8 SPE column and BPA-imprinted silica SPE (MIP-SPE) was compared. The MIP-SPE-HPLC method showed higher selectivity to BPA than the traditional SPE-HPLC method. At last, the BPA-imprinted polymers were used as the sorbent in solid-phase extraction to determine BPA in water samples with satisfactory recovery higher than 99% (R.S.D. 3.7%).  相似文献   

6.
A surface molecular imprinting technology was developed to adsorb Ce(III) ions that showed much higher adsorption affinity and selectivity for than for other metal ions. The batch adsorption process was studied with respect to effects of pH value, residence time, temperature, and initial concentration of Ce(III) ion. The maximum adsorption capacity is 43 mg g?1 at an initial Ce(III) concentration of 300 mg L?1 and at a sorbent dosage of 1.0 g L?1. A Langmuir isotherm fits the experimental data. The imprinted sorbent exhibits a much higher separation and selectivity for the target imprinted ion than the non-imprinted polymer. Cerium ion can be desorbed with 1M hydrochloric acid solution which is also proven by scanning electron microoscopy and X-ray diffraction experiments. The limit of detection is 37 ng mL?1. The sorbent has been applied to the determination of trace cerium in different environmental samples with satisfactory results.  相似文献   

7.
Jiang N  Chang X  Zheng H  He Q  Hu Z 《Analytica chimica acta》2006,577(2):225-231
A new Ni(II)-imprinted amino-functionalized silica gel sorbent with excellent selectivity for nickel(II) was prepared by an easy one-step reaction by combining a surface imprinting technique for selective solid-phase extraction (SPE) of trace Ni(II) in water samples prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Compared with non-imprinted polymer particles, the ion-imprinted polymers (IIPs) had higher selectivity and adsorption capacity for Ni(II). The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Ni(II) was 12.61 and 4.25 mg g−1, respectively. The relatively selective factor (αr) values of Ni(II)/Cu(II), Ni(II)/Co(II), Ni(II)/Zn(II) and Ni(II)/Pd(II) were 45.99, 32.83, 43.79 and 28.36, which were greater than 1. The distribution ratio (D) values of Ni(II)-imprinted polymers for Ni(II) were greatly larger than that for Cu(II), Co(II), Zn(II) and Pd(II). The detection limit (3σ) was 0.16 ng mL−1. The relative standard deviation of the method was 1.48% for eight replicate determinations. The method was validated by analyzing two certified reference materials (GBW 08618 and GBW 08402), the results obtained is in good agreement with standard values. The developed method was also successfully applied to the determination of trace nickel in plants and water samples with satisfactory results.  相似文献   

8.
Wu G  Wang Z  Wang J  He C 《Analytica chimica acta》2007,582(2):304-310
A new type of hierarchically organic-inorganic hybrid sorbent was prepared by a double-imprinting approach for the selective separation of Hg(II) from aqueous solution. In the imprinting process, both mercury ions and surfactant micelles (cetyltrimethylammonium bromide, CTAB) were used as templates, N-[3-(trimethoxy-silyl)propyl]ethylenediamine (TPED) as functional monomer, and tetraethoxysilane (TEOS) as cross-linking agent. The mercury ions and surfactant were removed from sorbent via acid leaching and ethanol extraction, respectively. The adsorption property and selective recognition ability of the sorbents were studied by equilibrium-adsorption method. Results showed that in the presence of Cu(II) or Cd(II) the biggest selectivity coefficient of the imprinted sorbents for Hg(II) was over 100, which is much higher than those of non-imprinted sorbents. The largest relative selectivity coefficient (k′) of the ion-imprinted functionalized sorbent between Hg(II) and Cu(II) was over 300, and between Hg(II) and Cd(II) over 200. The uptake capacities and the selectivity coefficients of the hierarchically imprinted sorbent were much higher than those of the sorbent prepared without CTAB template. Furthermore, the new imprinted sorbent possessed a fast kinetics for the removal of Hg(II) from aqueous solution with the saturation time less than 5 min, and could be used repeatedly. This sorbent has been successfully applied to the separation and determination of the trace Hg(II) in real water samples and those spiked with standards. This new sorbent can be used as an effective solid-phase extraction material for the selective preconcentration and separation of Hg(II) in environmental samples.  相似文献   

9.
A new Pb(II)-imprinted amino-functionalized silica gel sorbent was synthesized by an easy one-step reaction by combining a surface imprinting technique for selective solid-phase extraction of trace Pb(II) prior to its determination by inductively coupled plasma optical emission spectrometry. The Pb(II)-imprinted amino-functionalized silica gel sorbent was characterized by Fourier transform infrared spectroscopy. Compared to non-imprinted polymer particles, the ion-imprinted polymers had higher selectivity and adsorption capacity for Pb(II). The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Pb(II) was 19.66 and 6.20 mg g?1, respectively. The largest selectivity coefficient of the Pb(II)-imprinted sorbent for Pb(II) in the presence of Cd(II) was over 450. The relative selectivity (α r) values of Pb(II)/Cd(II) were 49.3 and 46.3, which were greater than 1. The distribution ratio (D) values of Pb(II)-imprinted polymers for Pb(II) were much larger than that for Cd(II). The detection limit (3σ) was 0.20 μg L?1. The relative standard deviation was 2.0% for 11 replicate determinations. The method was validated for the analysis three certified reference materials (GBW 08301, GBW 08504, GBW 08511), and the results are in good agreement with standard values. The method was also successfully applied to the determination of trace lead in plants and water samples with satisfactory results.  相似文献   

10.
A novel dual-ligand reagent (2Z)-N,N′-bis(2-aminoethylic)but-2-enediamide, was synthesized and applied to prepare metal ion-imprinted polymers (IIPs) materials by ionic imprinted technique for selective solid-phase extraction (SPE) of trace Cd(II) from aqueous solution. In the first step, Cd(II) formed coordination linkage with the two ethylenediamine groups of the synthetic monomer. Then the complex was copolymerized with pentaerythritol triacrylate (crosslinker) in the presence of 2,2′-azobisisobutyronitrile as initiator. Subsequently, the imprinted Cd(II) was completely removed by leaching the dried and powdered materials particles with 0.5 M HCl. The obtained IIPs particles exhibited excellent selectivity for target ion. The distribution ratio (D) values of Cd(II)-IIPs for Cd(II) were greatly larger than that for Cu(II), Zn(II) and Hg(II). The relative selective factor (αr) values of Cd(II)/Cu(II), Cd(II)/Zn(II) and Cd(II)/Hg(II) were 25.5, 35.3 and 62.1. The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cd(II) was 32.56 and 6.30 mg g−1, respectively. Moreover, the times of adsorption equilibration and complete desorption were remarkably short. The prepared Cd(II)-IIPs were shown to be promising for solid-phase extraction coupled with inductively coupled plasma atomic emission spectrometry (ICP-AES) for the determination of trace Cd(II) in real samples. The precision (R.S.D.) and detection limit (3σ) of the method were 2.4% and 0.14 μg L−1, respectively. The column packed with Cd(II)-IIPs was good enough for Cd(II) separation in matrixes containing components with similar chemical behaviour such as Cu(II), Zn(II) and Hg(II).  相似文献   

11.
A novel molecularly imprinted polymers based on multiwalled carbon nanotubes synthesized by precipitate polymerization was applied as a selective sorbent for separation and determination of rhein (4,5-dihydroxyanthraquinone-2-carboxylic acid) from the root of kiwi fruit samples coupled with high performance liquid chromatography (HPLC). The molecularly imprinted polymers were prepared with methacrylic acid and 4-vinylpyridine as bifunctional monomers. The chemical structure of the molecularly imprinted polymers was characterized by Fourier transform infrared spectrometer. The equilibrium rebinding experiment and competitive adsorption experiment showed that these imprinted polymers exhibited good adsorption ability toward rhein. The Langmuir adsorption equilibrium constant, K(m) , and theoretical maximum adsorption capacity, Q(m) , were estimated to be 0.43 and 6.77 mg g(-1) , respectively. Compared with molecularly imprinted polymers prepared with methacrylic acid or 4-vinylpyridine solely, the molecularly imprinted polymers synthesized with bifunctional monomers showed enhanced molecular imprinting effect and higher adsorption capacity for the template rhein. The performances of the molecularly imprinted polymers utilized as solid phase extraction sorbent were investigated in detail. The molecularly imprinted polymers prepared by the method proposed in this work could successfully apply to extraction and determination of rhein from the root of kiwi fruit samples coupled with HPLC.  相似文献   

12.
The aim of this work was to develop a method for the clean-up of a mycotoxin, i.e. Ochratoxin A (OTA), from cereal extracts employing a new molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE) and to compare with an immunoaffinity column. A first series of experiments was carried out in pure solvents to estimate the potential of the imprinted sorbent in terms of selectivity studying the retention of OTA on the MIP and on a non-imprinted polymer using conventional crushed monolith. The selectivity of the MIP was also checked by its application to wheat extracts. Then, after this feasibility study, two different formats of MIP: crushed monolith and micro-beads were evaluated and compared. Therefore an optimization procedure was applied to the selective extraction from wheat using the MIP beads. The whole procedure was validated by applying it to wheat extract spiked by OTA at different concentration levels and then to a certified contaminated wheat sample. Recoveries close to 100% were obtained. The high selectivity brought by the MIP was compared to the selectivity by an immunoaffinity cartridge for the clean-up of the same wheat sample. The study of capacity of both showed a significant higher capacity of the MIP.  相似文献   

13.
以3-氨丙基三甲氧基硅烷为离子配体,正硅酸乙酯为交联剂,借助微波辅助加热,在二氧化硅表面快速制备Cr(Ⅲ)离子印迹聚合物,聚合时间比常规时间缩短了5倍.利用扫描电镜对印迹聚合物形貌进行了表征,结果表明,该印迹聚合物粒径分布均匀,Cr(Ⅲ)离子成功地包覆在厚度约为40nm的印迹壳层内.详细地探讨了该印迹材料的吸附性能,并利用该印迹聚合物作为固相萃取填充料,成功地用于尿样中Cr(Ⅲ)的固相萃取.  相似文献   

14.
A novel composite material of multi-walled carbon nanotubes (MWNTs)-Sudan IV molecularly imprinted polymers (MIPs) was prepared by surface molecular imprinting technique in combination with sol-gel technology. The MWNTs-MIPs were evaluated by scanning electron micrograph (SEM), Fourier transform infrared spectroscopy (FT-IR), and adsorption experiments. The results showed that the MWNTs-MIPs exhibited good selective recognition to Sudan IV. The maximum saturated binding capacity (Qmax) is 63.2 μmol g−1. Applied as sorbent, the MWNTs-MIPs were used for the determination of trace Sudan IV in chilli powder by on-line solid-phase extraction-high-performance liquid chromatography (SPE-HPLC). The results showed that an enrichment factor of 741 was achieved with a loading flow rate of 1.0 mL min−1 for sampling 50 mL. The MWNTs-MIPs provided a fast and convenience determination platform for Sudan IV in real samples.  相似文献   

15.
An ion-imprinted polymer (IIP) was obtained by copolymerization of methacrylic acid (as a functional monomer) and ethylene glycol dimethacrylate (as a crosslinking agent) in the presence of various chelators for Pt(II) ion and using 2,2??-azo-bis-isobutyronitrile as the initiator. Specifically, acetaldehyde thiosemicarbazone (AcTSn) and benzaldehyde thiosemicarbazone (BnTSn) were used as chelators. The IIPs were applied as sorbents for solid-phase extraction of Pt(II) and Pt(IV) ions from aqueous solutions. The effects of acidity and flow rate of the sample, of elution conditions and of potentially interfering ions were investigated. The imprinting effect of analyte is clearly demonstrated by the fact that only the IIP is capable of quantitative retention of Pt(II) and Pt(IV) ions. The method works best in the pH range from 0.5 to 1 and from 3.5 to 9.5. The ions can be recovered with an acidic solution of thiourea. The Pt-AcTSn polymer displays better sorption properties for the separation of analytes. The selectivity coefficients of the Pt-AcTSn and control polymers for Pt(IV) in the presence Pd(II), Rh(III), Ru(III), Al(III) and Cu(II) were calculated, and the sorbent capacity for Pt(IV) was found to be 4.56???g?g?-1. The method was successfully applied to the determination of Pt(IV) by electrothermal atomic absorption spectrometry in tap water, tunnel dust and anode slime samples.
Figure
The new ion imprinted polymers based on Pt(II)-thiosemicarbazone derivative chelates were prepared and used as solid phase extraction sorbent for selective separation of platinum. The method was successfully applied to the determination of analyte in environmental samples by electrothermal atomic absorption spectrometry  相似文献   

16.
Highly selective molecularly imprinted layer-coated silica nanoparticles for bisphenol A (BPA) were synthesized by molecular imprinting technique with a sol-gel process on the supporter of silica nanoparticles. The BPA-imprinted silica nanoparticles were characterized by fourier transform infrared spectrometer, transmission electron microscope, dynamic adsorption and static adsorption tests. The equilibrium association constant, Ka, and the apparent maximum number of binding sites, Qmax, were estimated to be 1.25 × 105 mL μmol−1 and 16.4 μmol g−1, respectively. The BPA-imprinted silica nanoparticles solid-phase extraction (SPE) column had higher selectivity for BPA than the commercial C18-SPE column. The results of the study indicated that the prepared BPA-imprinted silica nanoparticles exhibited high adsorption capacity and selectivity, and offered a fast kinetics for the rebinding of BPA. The BPA-imprinted silica nanoparticles were successfully used in SPE to selectively enrich and determine BPA from shampoo, bath lotion and cosmetic cream samples.  相似文献   

17.
A molecularly imprinted polymer (MIP) able to selectively bind triclosan (TCS) and triclocarban (TCC), commonly used antibacterial agents in many consumer products, was prepared using noncovalent molecular imprinting methods. The prepared MIP was evaluated as a selective sorbent in SPE for sample cleanup before HPLC-UV analysis of TCS and TCC in soil and biosolid samples. The MIP was also compared with commercially available C18 SPE sorbent. The molecularly imprinted SPE (MISPE) developed in this study was more efficient than C18 SPE for the cleanup of extracts of soil and biosolid samples prior to the analysis of TCC and TCS using HPLC-UV. The LOQ values for both TCC and TCS in the soil samples were determined to be 40 microg/kg; in the biosolid samples, the LOQ values were 100 and 300 microg/kg for TCC and TCS, respectively. Compared to C18 SPE, using MISPE for sample cleanup may result in a significant reduction of analytical cost, because one MIP can be reused up to 35 times and HPLC-UV instead of HPLC/MS can be used for instrumental analysis following sample cleanup by MISPE.  相似文献   

18.
A highly selective imprinted amino-functionalized silica gel sorbent was prepared by combining a surface molecular imprinting technique with a sol-gel process for on-line solid-phase extraction-HPLC determination of trace pentachlorophenol (PCP) in water samples. The PCP-imprinted amino-functionalized silica sorbent was characterized by FT-IR, SEM, nitrogen adsorption and the static adsorption experiments. The imprinted functionalized silica gel sorbent exhibited high selectivity and offered a fast kinetics for the adsorption and desorption of PCP. The prepared sorbent was shown to be promising for on-line solid-phase extraction for HPLC determination of trace levels of PCP in environmental samples. With a sample loading flow rate of 5 ml min(-1) for 2 min, an enhancement factor of 670 and a detection limit (S/N = 3) of 6 ng l(-1) were achieved at a sample throughput of five samples h(-1). The precision (RSD) for nine replicate on-line sorbent extractions of 10 microgl(-1) PCP was 3.8%. The sorbent also offered good linearity (r = 0.9997) for on-line solid-phase extraction of trace levels of PCP. The method was applied to the determination of PCP in local lake water, river water and wastewater samples.  相似文献   

19.
Zhang N  Suleiman JS  He M  Hu B 《Talanta》2008,75(2):536-543
A new chromium(III)-imprinted 3-(2-aminoethylamino) propyltrimethoxysilane (AAPTS)-functionalized silica gel sorbent was synthesized by a surface imprinting technique and was employed as a selective solid-phase extraction material for speciation analysis of chromium in environmental water samples prior to its determination by inductively coupled plasma mass spectrometry (ICP-MS). The prepared Cr(III)-imprinted silica gel shows the selectivity coefficient of more than 700 for Cr(III) in the presence of Mn(II). The static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cr(III) were 30.5 mg g(-1) and 13.4 mg g(-1). It was also found that Cr(VI) could be adsorbed at low pH by the prepared imprinted silica gel, and this finding makes it feasible to enrich and determine Cr(VI) at low pH without adding reducing reagents. The imprinted silica gel sorbent offered a fast kinetics for the adsorption and desorption of both chromium species. Under the optimized conditions, the detection limits of 4.43 pg mL(-1) and 8.30 pg mL(-1) with the relative standard deviations (R.S.D.s) of 4.44% and 4.41% (C=0.5 ng mL(-1), n=7) for Cr(III) and Cr(VI) were obtained, respectively. The proposed method was successfully applied to the speciation of trace chromium in environmental water samples. To validate the proposed method, two certified reference materials were analyzed and the determined values were in a good agreement with the certified values. The developed method is rapid, selective, sensitive and applicable for the speciation of trace chromium in environmental water samples.  相似文献   

20.
As shown in the past years, SPE based on molecularly imprinted polymers (MIPs) may provide significant enhancement of selectivity in sample preparation and analyte preconcentration. The objective of this work was the fabrication of MIPs for the specific adsorption of rutin and quercetin. The two flavonoids were used as the template molecules for the preparation of MIP phases in a self-assembly (noncovalent) approach. The produced MIPs were validated with regard to the imprinting efficiency as media for LC and SPE. The retention behavior of several flavonoid compounds was studied using as stationary phases imprinted, control nonimprinted polymers, and commercial silica-based materials. MIPs were applied as materials for the selective SPE and preconcentration of the flavonoids from white and red wine, orange juice, and tea. The collected fractions were analyzed by high-pressure LC. MIP-SPE facilitated specific analyte isolation and effective sample clean-up. The results show that molecularly imprinted SPE can be a useful tool for the simple, selective, and cost-effective pretreatment of samples containing natural antioxidants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号