首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
Chi Y  Xie J  Chen G 《Talanta》2006,68(5):1544-1549
The electrochemiluminescent (ECL) response of allopurinol was studied in aqueous media over a wide pH range (pH 2–13) using flow injection (FI) analysis. It was revealed that allopurinol itself had no ECL activity, but could greatly enhance the ECL of Ru(bpy)32+ in alkaline media giving rise to a sensitive FI-ECL response. The effects of experimental conditions including the mode of applied voltage signal, the potential of working electrode, pH value, the flow rate of carrier solution, and the concentration of Ru(bpy)32+ and allopurinol on the ECL intensity were investigated in detail. The most sensitive FI-ECL response of allopurinol was found at pH 12.0, where the FIA-ECL intensity showed a linear relationship with concentration of allopurinol in the range 1 × 10−8 mol L−1 to 5 × 10−7 mol L−1, and the detection limit was 5 × 10−9 mol L−1.  相似文献   

2.
Electrochemical studies of famotidine were carried out using voltammetric techniques: cyclic voltammetry, linear sweep and square wave adsorptive stripping voltammetry. The dependence of the current on pH, buffer concentration, nature of the buffer, and scan rate was investigated. The best results for the determination of famotidine were obtained in MOPS buffer solution at pH 6.7. This electroanalytical procedure enabled to determine famotidine in the concentration range 1 × 10−9–4 × 10−8 mol L−1 by linear sweep adsorptive stripping voltammetry (LS AdSV) and 5 × 10−10–6 × 10−8 mol L−1 by square wave adsorptive stripping voltammetry (SW AdSV). Repeatability, precision and accuracy of the developed methods were checked. The detection and quantification limits were found to be 1.8 × 10−10 and 6.2 × 10−10 mol L−1 for LS AdSV and 4.9 × 10−11 and 1.6 × 10−10 mol L−1 for SW AdSV, respectively. The method was applied for the determination of famotidine in urine.  相似文献   

3.
Trace amounts of nickel(II) can function as a trigger (=reaction initiator) in an autocatalytic reaction with the sodium sulfite/hydrogen peroxide system. Based on this finding, sub-μg L−1 levels of nickel(II) were determined by a time measurement using the autocatalytic reaction. The detection range using the above method was 10−9–10−5 M, the detection limit (3σ) was 8.1 × 10−10 M (0.047 μg L−1), and the relative standard deviation was 2.66% at nickel(II) concentration of 10−7 M (n = 7). This method was applied to length detection-flow injection analysis. The detection range for the flow injection analysis was 2 × 10−9–2 × 10−3 M. The detection limit (3σ) was 1.4 × 10−9 M (0.082 μg L−1), and the relative standard deviation was 1.86 at initial nickel(II) concentration of 10−6 M (n = 7).  相似文献   

4.
An adsorptive stripping voltammetric (AdSV) procedure for simultaneous determination of Ni(II) and Co(II) in the presence of nioxime as a complexing agent at an in situ plated lead film electrode was described. The Co(II) signal was enhanced by exploitation of the catalytic process in the presence of nitrite. Ni(II) and Co(II) signals are better separated than in the case of bismuth film electrodes. Calibration graphs for an accumulation time of 120 s are linear from 1 × 10−9 to 1 × 10−7 mol L−1 and from 1 × 10−10 to 5 × 10−9 mol L−1 for Ni(II) and Co(II), respectively. The proposed procedure was applied for Ni(II) and Co(II) determination in water certified reference materials.  相似文献   

5.
Wu X  Huang F  Duan J  Chen G 《Talanta》2005,65(5):1279-1285
Melatonin and some of its important derivatives were found to be able to enhance the ECL of Ru(bpy)32+ in an alkaline Britton–Robinson buffer solution. The optimum conditions for the enhanced ECL, such as the selection of applied potential mode, type of buffer solution, pH effect and effect of Ru(bpy)32+ concentration have been investigated in detail in this paper. Under the optimum conditions, the enhanced ECL is linear with the concentration of melatonin and its derivatives over the wide range, and the detection limit for these compounds was found to be in the range of 5.0 × 10−8 to 1.0 × 10−10 mol L−1. The proposed procedure was applied for the determination of drug in tablets with recoveries of 85–93%. A possible mechanism for the enhanced ECL of Ru(bpy)32+ by melatonin and its derivatives was proposed, and the relationship between molecular structure of melatonin and its derivatives and the enhanced ECL behavior was also discussed.  相似文献   

6.
Campuzano S  Pedrero M  Pingarrón JM 《Talanta》2005,66(5):1310-1319
The construction and performance under flow-injection conditions of an integrated amperometric biosensor for hydrogen peroxide is reported. The design of the bioelectrode is based on a mercaptopropionic acid (MPA) self-assembled monolayer (SAM) modified gold disk electrode on which horseradish peroxidase (HRP, 24.3 U) was immobilized by cross-linking with glutaraldehyde together with the mediator tetrathiafulvalene (TTF, 1 μmol), which was entrapped in the three-dimensional aggregate formed.

The amperometric biosensor allows the obtention of reproducible flow injection amperometric responses at an applied potential of 0.00 V in 0.05 mol L−1 phosphate buffer, pH 7.0 (flow rate: 1.40 mL min−1, injection volume: 150 μL), with a range of linearity for hydrogen peroxide within the 2.0 × 10−7–1.0 × 10−4 mol L−1 concentration range (slope: (2.33 ± 0.02) × 10−2 A mol−1 L, r = 0.999). A detection limit of 6.9 × 10−8 mol L−1 was obtained together with a R.S.D. (n = 50) of 2.7% for a hydrogen peroxide concentration level of 5.0 × 10−5 mol L−1. The immobilization method showed a good reproducibility with a R.S.D. of 5.3% for five different electrodes. Moreover, the useful lifetime of one single biosensor was estimated in 13 days.

The SAM-based biosensor was applied for the determination of hydrogen peroxide in rainwater and in a hair dye. The results obtained were validated by comparison with those obtained with a spectrophotometric reference method. In addition, the recovery of hydrogen peroxide in sterilised milk was tested.  相似文献   


7.
In this work, nickel hexacyanoferrate-modified electrode was developed to determine potassium ions in biodiesel by potentiometry. The modified electrodes exhibit a linear response to potassium ions in the concentration range of 4.0 × 10−5 to 1.0 × 10−2 mol L−1, with a detection limit of 1.9 × 10−5 mol L−1, and a near-Nernstian slope (53–55 mV per decade) at 25 °C. The method developed in this work was compared with flame photometry and the potassium concentration found in biodiesel showed that the modified electrode method gives results similar to those obtained by flame photometry.  相似文献   

8.
Fenoterol and salbutamol were determined by electrogenerated chemiluminescence (ECL) coupled with flow injection analysis (FIA), using Ru(bpy)32+ as the luminescent substance. Fenoterol and salbutamol oxidize together with the ruthenium 2,2-bipyridyl at a platinum electrode, which leads to an increase in the luminescent intensity, and this increase is proportional to the analyte concentration. For fenoterol a linear calibration curve within the range from 1.0 × 10−5 to 1.0 × 10−4 mol l−1 was obtained with a correlation coefficient of 0.998 (n = 5) and for salbutamol the linear analytical curve was also obtained in this range with a correlation coefficient of 0.995 (n = 5). The relative standard deviation was estimated as ≤2.5% for 3 × 10−5 mol l−1 for fenoterol solution and as ≤1.3% for 5.0 × 10−5 mol l−1 salbutamol solution for 15 successive injections. The limit of detection for fenoterol was 2.4 × 10−7 mol l−1 and for salbutamol was 4.0 × 10−7 mol l−1. Fenoterol and salbutamol were successfully determined in drug tablets and the soluble components of the matrix did not interfere in the luminescent emission. The results obtained using the luminescent methodology were not statistically different from those obtained by UV-spectrophotometry at 95% confidence level.  相似文献   

9.
A sensitive and rapid electrochemical method was developed for the determination of telmisartan based on the enhancement effect of sodium dodecyl benzene sulfonate (SDBS). In 0.1 mol L−1 HClO4 and in the presence of 7.5 × 10−5 mol L−1 SDBS, a well-defined and sensitive oxidation peak was observed for telmisartan at the acetylene black (AB) paste electrode. However, the oxidation peak is poor-shaped and the peak current is very low in the absence of SDBS, suggesting that SDBS shows obvious enhancement effect for the determination of telmisartan. After all the experimental parameters were optimized, a sensitive and simple electrochemical method was developed for determining telmisartan. The oxidation peak current is proportional to the concentration of telmisartan over the range from 2.5 × 10−7 to 2.0 × 10−5 mol L−1. The detection limit is 7.5 × 10−8 mol L−1 after 2 min of accumulation. This new voltammetric method was successfully used to detect telmisartan in drugs.  相似文献   

10.
Zhang BT  Zhao L  Lin JM 《Talanta》2008,74(5):1154-1159
Based on the chemiluminescence (CL) phenomena of folic acid in peroxomonosulfate-cobalt(II) system, a rapid and sensitive CL method was developed for determination of folic acid in pharmaceutical preparations and its urinary metabolism processes. Under the optimum conditions, the relative CL intensity was linear over the concentration ranging from 10−9 to 8 × 10−7 mol L−1 (R2 = 0.9991) with a detection limit as low as 6 × 10−10 mol L−1 (S/N = 3) and relative standard deviation was 2.63% for 2 × 10−8 mol L−1 folic acid (n = 11). This method has been successfully applied to the determination of folic acid in tablets and human urine. The blank CL emission was yielded owing to the formation of singlet oxygen molecular pair from the quenching experiment of 1,4-diazabicyclo[2.2.2]octane, and pterine-6-carboxylic acid might be the degradation intermediate in this system and it also acts an energy acceptor and sensitizes the chemiluminescence based on the studies of the CL and fluorescence spectra.  相似文献   

11.
An ionic liquid-type carbon paste electrode (IL-CPE) had been fabricated by replacing non-conductive organic binders with a conductive room temperature ionic liquid, 1-pentyl-3-methylimidazolium hexafluorophosphate (PMIMPF6). The electrochemical responses of calcium dobesilate were investigated at the IL-CPE and the traditional carbon paste electrode (T-CPE) in 0.05 mol L−1 H2SO4, respectively. The results showed the superiority of IL-CPE to T-CPE in terms of provision of higher sensitivity, faster electron transfer and better reversibility. A novel method for determination of calcium dobesilate was proposed. The oxidation peak current was rectilinear with calcium dobesilate concentration in the range of 8.0 × 10−7 to 1.0 × 10−4 mol L−1, with a detection limit of 4.0 × 10−7 mol L−1(S/N = 3) by differential pulse voltammetry. The proposed method was applied to directly determine calcium dobesilate in capsule and urine samples.  相似文献   

12.
A new, highly sensitive and simple kinetic method for the determination of thyroxine was proposed. The method was based on the catalytic effect of thyroxine on the oxidation of As(III) by Mn(III) metaphosphate. The kinetics of the reaction was studied in the presence of orthophosphoric acid. The reaction rate was followed spectrophotometrically at 516 nm. It was established that orthophosphoric acid increased the reaction rate and that the extent of the non-catalytic reaction was extremely small. A kinetic equation was postulated and the apparent rate constant was calculated. The dependence of the reaction rate on temperature was investigated and the energy of activation and other kinetic parameters were determined.

Thyroxine was determined under the optimal experimental conditions in the range 7.0 × 10−9 to 3.0 × 10−8 mol L−1 with a relative standard deviation up to 6.7% and a detection limit of 2.7 × 10−9 mol L−1. In the presence of 0.08 mol L−1 chloride, the detection limit decreased to 6.6 × 10−10 mol L−1. The proposed method was applied for the determination of thyroxine in tablets. The accuracy of the method was evaluated by comparison with the HPLC method.  相似文献   


13.
Flow injection visible diffuse reflectance quantitative analysis of nickel   总被引:1,自引:0,他引:1  
Flow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of nickel, precipitated in the form of dimethylglyoximate, is presented. A reflectance cell, constructed in polytetrafluoroethylene, using a LED (light emitting diode) as light source and a LDR (light dependent resistor) as detector, is described. The analytical signal (S) correlates with nickel concentration (C) between 1.6 × 10−4 and 6.6 × 10−4 mol L−1. This correlation is described by the equation S = −1.108 + 3.314 × 104C − 2.081 × 107C2 (r = 0.9996). The experimentally observed limit of detection is about 1.3 × 10−4 mol L−1, as in lower concentrations the formation of precipitate is not observed. The experimental quantitation limit is about 1.6 × 10−4 mol L−1. The mean R.S.D. (relative standard deviation) is about 2.7%. Samples containing nickel were analyzed and the results obtained in this method were compared with those of other methods using the statistical Student's t-test.  相似文献   

14.
Yu F  Li L  Chen F 《Analytica chimica acta》2008,610(2):257-262
A new spectrofluorimetric method is developed for determination of adenosine disodium triphosphate (ATP). The interactions between prulifloxacin (PUFX)–Tb3+ complex and adenosine disodium triphosphate has been studied by using UV–vis absorption and fluorescence spectra. Using prulifloxacin–Tb3+ as a fluorescence probe, under the optimum conditions, ATP can remarkably enhance the fluorescence intensity of the prulifloxacin–Tb3+ complex at λ = 545 nm and the enhanced fluorescence intensity is in proportion to the concentration of ATP. Optimum conditions for the determination of ATP were also investigated. The dynamic range for the determination of ATP is 4.0 × 10−7 to 2.0 × 10−5 mol L−1, and the detection limit (3 σ/k) is 1.7 × 10−8 mol L−1. This method is simple, practical and relatively free interference from coexisting substances and can be successfully applied to determination of ATP in real pharmaceutical samples. The mechanism of fluorescence enhancement of prulifloxacin–Tb3+ complex by ATP was also discussed.  相似文献   

15.
Wang Y  Yin X  Shi M  Li W  Zhang L  Kong J 《Talanta》2006,69(5):1240-1245
A novel electrochemical sensor with capability of probing chiral amino acids with gold nanoparticle (n-Au) labels using bovine serum albumin (BSA) as a chiral selector and subsequent signal amplification step by silver enhancement is introduced. The assay relies on the stereoselectivity of BSA embedded in ultrathin γ-alumina sol–gel film coated on the surface of the glassy carbon electrode (GCE). The recognition to the n-Au-labeled l- or d-amino acids for BSA-GCE could be monitored by the differential pulse voltammetry (DPV), while the DPV signal was greatly amplified by the anchored silver atoms on the n-Au, leading to a new way of quantitatively analysis of chiral amino acids electrochemically at sub-picomolar level. With l-tryptophan as the probe solute, the linear concentration range was from 1.33 × 10−12 to 1 × 10−9 mol L−1 and detection limit was 5 × 10−13 mol L−1. For tryptophan enantiomers, the enantioselectivity coefficient 2.3 was obtained.  相似文献   

16.
The cysteamine (CA) was bound onto surface of the pretreated glassy carbon electrode (GC) with cyclic voltammetry (CV). Gold nanoparticles were self-assembled to the electrode binding with cysteamine via strong AuS covalent bond to fabricate the nano-Au self-assembled modified electrode (nano-Au/CA/GC). The modified electrode was characterized with cyclic voltammetric and ac impedance methods. The electrochemical behavior of dopamine (DA) on the modified electrode was investigated with cyclic voltammetry and differential pulse voltammetry (DPV). A well-defined redox peaks of DA on the nano-Au/CA/GC electrode were obtained at Epa = 0.175 V and Epc = 0.146 V (vs. SCE), respectively. The peak current of DA is linear with the concentration of DA in the range of 1.0 × 10−8 mol L−1 to 2.5 × 10−5 mol L−1, with the correlation coefficient of 0.998. The detection limit is 4.0 × 10−9 mol L−1 (S/N = 3). The modified electrode exhibited an excellent reproducibility, sensibility and stability for determination of DA in the presence of high concentration AA, and can be applied to determinate dopamine injection, with satisfied result.  相似文献   

17.
Zenki M  Tanishita A  Yokoyama T 《Talanta》2004,64(5):1273-1277
Ascorbic acid (AA) could be determined in large quantities of a co-existing oxidant. The incorporation of an on-line reagent regeneration step based on redox reaction eliminates the baseline drift in the procedure. This makes it possible to adopt a circulatory flow injection method (cyclic FIA) and to determine AA repetitively. The method is based on the reduction of iron(III) to iron(II) by the analyte, the reaction of the produced iron(II) with 1,10-phenanthroline (phen) in a weak acidic medium to form a colored complex, and the subsequent oxidation reaction of iron(II) to iron(III) by the co-existing peroxodisulfate. A solution (50 ml) of 3.0×10−4 mol l−1 ferric chloride, 9.0×10−4 mol l−1 phen and 5.0×10−2 mol l−1 ammonium peroxodisulfate in acetate buffer (0.2 mol l−1, pH 4.5) is continuously circulated at a constant flow rate of 1.0 ml min−1. Into this stream, an aliquot (20 μl) of the sample solution containing AA is quickly injected by means of a six-way valve. The complex formed is monitored spectrophotometrically (at 510 nm) in the flow system. The stream then returns to the reservoir after passing through a time-delay coil (50 m). The iron(II)–(phen)3 complex is oxidized to iron(III)–(phen)3 complex by peroxodisulfate which exists excessively in the circulating reagent solution. The proposed method allows as many as 300 repetitive determinations of 15 mg l−1 AA with only 50 ml reservoir solution. The contents of AA in commercial pharmaceutical products were analyzed to demonstrate the capability of the developed system.  相似文献   

18.
Gold nanoparticles were self-assembled to the modified glassy carbon electrode (GC) with cysteamine (CA) to prepare the nano-Au/CA/GC modified electrode. The electrochemical behavior of epinephrine (EP) on the modified electrode was explored with cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Epinephrine gave a pair of redox peaks at Epa = 0.190 mV and Epc = −0.224 mV (versus SCE), respectively. The nano-Au/CA/GC modified electrode shows an excellent electrocatalytic activity for the oxidation of EP. The modified electrode could be used to determine EP in the presence of ascorbic acid (AA). The response of catalytic current with EP concentration shows a linear relation in the range of 1.0 × 10−7 to 5.0 × 10−4 mol L−1 with the correlation coefficient of 0.998. The detection limit is 4.0 × 10−8 mol L−1. The modified electrode exhibited a good reproducibility, sensitivity and stability for the determination of EP injection.  相似文献   

19.
Ling Mei  Yu Xiang  Na Li  Aijun Tong   《Talanta》2007,72(5):1717-1722
A new fluorescent probe, rhodamine B hydrazide oxalamide (RBHO), which shows very weak fluorescence, was synthesized, and its fluorescence could be substantially enhanced by the addition of copper ion. The probe shows a high selectivity and sensitivity to copper ion by forming a 1:1 complex in acetonitrile, and the chelating is reversible. Limit of detection for copper ion in acetonitrile was found to be 3.7 × 10−8 mol L−1. It was also found that copper ion could catalyze the hydrolysis of the probe in 50% (v/v) buffered (10 mM Tris–HCl, pH 7.0) water/acetonitrile giving a highly fluorescent product, and the fluorescence detection of copper ion was developed in this neutral buffered media with a detection limit of 6.4 × 10−7 mol L−1. Determination of copper ion in water and synthetic samples in the presence of different interfering metal ions was successfully carried out with the new probe RBHO.  相似文献   

20.
A detailed study for the spectrophotometric readout method for L-threonine powder, [CH3CH(OH)CH(NH2)COOH], was done. In this method, 400 mg unirradiated/irradiated L-threonine powder was dissolved in 10 ml of a solution which contains 3×10−4 mol dm−3 ferrous ammonium sulphate and 1.7×10−4 mol dm−3 xylenol orange (XO) in aerated aqueous 0.17 mol dm−3 sulphuric acid (FX). The peroxy radicals produced from irradiated threonine oxidize ferrous ions and XO forms a complex with ferric ions as well as controls the chain length of ferrous ion oxidation. The plot of absorbance at 556 nm against dose is linear in the dose range 20–400 Gy and doses down to about 1 Gy can be measured using 10-cm path cells. Response of the dosimeter is independent of irradiation temperature above 20. A dose of 50 Gy–10 kGy can be measured dissolving 50 mg threonine powder in 10 ml of a solution which contains 3×10−4 mol dm−3 ferrous ammonium sulphate and 1.3×10−4 mol dm−3 XO in aerated aqueous 0.06 mol dm−3 sulphuric acid (FX). The plot of absorbance at 552 nm against dose is non-linear. However dosimeter shows linear dose response up to 1000 Gy. Irradiated threonine powder is stable for about 3 months. The reproducibility of the method is better than ±2%. This dosimeter is very useful as transfer dosimeter for food irradiation programme.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号