首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Kole PL  Millership J  McElnay JC 《Talanta》2011,85(4):1948-1958
A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r = 0.9999) over a concentration range of 100-2000 ng mL−1. SBSE showed consistent recoveries (∼70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL−1 and 36.37 ng mL−1, respectively, however, for the experimental purposes, 100 ng mL−1 was considered as the validated LOQ (accuracy and precision at this LQC was <20%). Further, studies on various attributes of the stir bar/SBSE, showed no significant inter- and intra-stir bar variability for DIC extraction. There was no carryover effect with re-use of conditioned stir bars and for the first time, a systematic investigation on the effect of ageing of stir bars on their extraction efficiency was carried out. Results showed that, for the present study, stir bars which were used 150 times were still functional based on in-house acceptance criteria and extraction efficiency. The validated method was successfully applied to the analysis of DIC in paediatric clinical trial samples.  相似文献   

2.
A comparison of direct immersion solid-phase microextraction (DI-SPME) and stir bar sorptive extraction (SBSE) coupled to liquid chromatography (HPLC) with fluorimetric detection for the rapid analysis of resveratrol isomers is described. For DI-SPME, a polar Carbowax-template resin (CW/TPR) 50 μm fiber was the most efficient and optimum extraction conditions were 40 °C and an extraction time of 30 min, stirring in the presence of 5% (m/v) sodium chloride and 0.07 M acetate/acetic acid buffer (pH 6). Desorption was carried out using the static mode for 10 min. Linearity was obtained in the 5-150 and 2-150 ng mL−1 ranges for trans- and cis-resveratrol, with detection limits of 2 and 0.5 ng mL−1, respectively. When using SBSE, a polydimethylsiloxane (PDMS) twister provided best extraction by means of a derivatization reaction in the presence of acetic anhydride and potassium carbonate. The same time and temperature were used for the extraction step in the presence of 2.5% (m/v) sodium chloride, and liquid desorption was performed with 150 μL of a 50/50 (v/v) acetonitrile/1% (v/v) acetic acid solution in a desorption time of 15 min. Linearity was now between 0.5 and 50 ng mL−1 for trans-resveratrol with a detection limit of 0.1 ng mL−1, while cis-resveratrol could not be extracted. The proposed methods were successfully applied to determining the resveratrol isomer content of wine, must and fruit juices.  相似文献   

3.
A simple and highly sensitive method called thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 4-nonylphenol (NP) and 4-tert.-octylphenol (OP) in water samples, is described. NP and OP in samples are extracted from water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 °C) in a headspace vial. Then the extract is high sensitively analyzed by TD-GC-MS without any derivatization step. The optimum SBSE conditions are realized at an extraction time of 60 min. The detection limits are 0.02 ng ml−1 for NP and 0.002 ng ml−1 for OP. The method shows good linearity over the concentration range of 0.1-10 ng ml−1 for NP and 0.01-10 ng ml−1 for OP, and the correlation coefficients are higher than 0.999. The average recoveries of NP and OP are higher than 97% (R.S.D.: 3.6-6.2%) with correction using the added surrogate standards, 4-(1-methyl) octylphenol-d5 and deuterium 4-tert.-octylphenol. This simple, accurate, sensitive and selective analytical method may be used in the determination of trace amounts of NP and OP in tap and river water samples.  相似文献   

4.
A novel hyphenated technique, namely the combination of stir bar sorptive extraction (SBSE) with isotope dilution direct analysis in real time (DART) Orbitrap™ mass spectrometry (OT-MS) is presented for the extraction of phosphoric acid alkyl esters (tri- (TnBP), di- (HDBP), and mono-butyl phosphate (H2MBP)) from aqueous samples. First, SBSE of phosphate esters was performed using a Twister™ coated with 24 μL of polydimethylsiloxane (PDMS) as the extracting phase. SBSE was optimized for extraction pH, phase ratio (PDMS volume/aqueous phase volume), stirring speed, extraction time and temperature. Then, coupling of SBSE to DART/Orbitrap-MS was achieved by placing the Twister™ in the middle of an open-ended glass tube between the DART and the Orbitrap™. The DART mass spectrometric response of phosphate esters was probed using commercially available and synthesized alkyl phosphate ester standards. The positive ion full scan spectra of alkyl phosphate triesters (TnBP) was characterized by the product of self-protonation [M + H]+ and, during collision-induced dissociation (CID), the major fragmentation ions corresponded to consecutive loss of alkyl chains. Negative ionization gave abundant [M − H] ions for both HDnBP and H2MnBP. Twisters™ coated with PDMS successfully extracted phosphate acid esters (tri-, di- and mono-esters) granted that the analytes are present in the aqueous solution in the neutral form. SBSE/DART/Orbitrap-MS results show a good linearity between the concentrations and relative peak areas for the analytes in the concentration range studied (0.1–750 ng mL−1). Reproducibility of this SBSE/DART/Orbitrap-MS method was evaluated in terms of %RSD by extracting a sample of water fortified with the analytes. The %RSDs for TnBP, HDnBP and H2MnBP were 4, 3 and 3% (n = 5) using the respective perdeuterated internal standards. Matrix effects were investigated by matrix matched calibration standards using underground water samples (UWS) and river water samples (RWS). Matrix effects were effectively compensated by the addition of the perdeuterated internal standards. The application of this new SBSE/DART/Orbitrap-MS method should be very valuable for on-site sampling/monitoring, limiting the transport of large volumes of water samples from the sampling site to the laboratory.  相似文献   

5.
Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol–gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar−1. The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L−1 and the relative standard deviation (RSD) was 3.38% (c = 1 μg L−1, n = 7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.  相似文献   

6.
This article presents a method employing stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry for the analysis of fluoxetine in plasma samples. Ethyl chloroformate was employed as derivatizing agent producing symmetrical peaks. Parameters such as solvent polarity, time for analyte desorption, and extraction time, were evaluated. During the validation process, the developed method presented specificity, linearity (R2 > 0.99), precision (R.S.D. < 15%), and limits of quantification (LOQ) of 30 and 1.37 pg mL−1, when liquid and thermal desorption were employed, respectively. This simple and highly sensitive method showed to be adequate for the measurement of fluoxetine in typical and trace concentration levels.  相似文献   

7.
A comparison is made between static headspace analysis and stir bar sorptive extraction (SBSE) for the quantitative determination of furan. The SBSE technique was optimised and evaluated using two example food matrices (coffee and jarred baby food). The use of the SBSE technique in most cases, gave comparable results to the static headspace method, using the method of standard additions with d4-labelled furan as an internal standard. Using the SBSE method, limits of detection down to 2 ng g−1 were achieved, with only a 1 h extraction. The method was performed at ambient temperatures, thus eliminating the possibility of formation of furan during extraction.  相似文献   

8.
A fully automated cold fiber solid phase microextraction device has been developed by coupling to a GERSTEL multipurpose (MPS 2) autosampler and applied to the analysis of volatiles and semi-volatiles in aqueous and solid matrices. The proposed device was thoroughly evaluated for its extraction performance, robustness, reproducibility and reliability by gas chromatograph/mass spectrometer (GC/MS). With the use of a septumless head injector, the entire automated setup was capable of analyzing over 200 samples without any GC injector leakages. Evaluation of the automated cold fiber device was carried out using a group of compounds characterized by different volatilities and polarities. Extraction efficiency as well as analytical figures of merit was compared to commercial solid phase microextraction fibers. The automated cold fiber device showed significantly improved extraction efficiency compared to the commercial polydimethylsiloxane (PDMS) and cold fiber without cooling for the analysis of aqueous standard samples due to the low temperature of the coating. Comparing results obtained from cold fiber and commercial divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber temperature profile demonstrated that the temperature gap between the sample matrix and the coating improved the distribution coefficient and therefore the extraction amount. The linear dynamic range of the cold fiber device was 0.5 ng mL−1 to 100 ng mL−1 with a linear regression coefficient ≥0.9963 for all compounds. The limit of detection for all analytes ranged from 1.0 ng mL−1 to 9.4 ng mL−1. The newly automated cold fiber device presents a platform for headspace analysis of volatiles and semi-volatiles for large number of samples with improved throughput and sensitivity.  相似文献   

9.
Huang SD  Huang HI  Sung YH 《Talanta》2004,64(4):887-893
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the determination of triazine is described. Carbowax/templated resin (CW/TPR, 50 μm), polydimethylsiloxane/divinylbenzene (PDMS/DVB, 60 μm), polydimethylsiloxane (PDMS, 100 μm), and polyacrylate (PA, 85 μm) fibers were evaluated for extraction of the triazines. CW/TPR and PDMS/DVB fibers were selected for further study. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, desorption mode, desorption time, compositions of solvent for desorption, soaking periods and the flow rate during desorption period, extraction time, temperature, pH, and ionic strength of samples). Both CW/TPR and PDMS/DVB fibers are acceptable; a simple calibration-curve method based on simple aqueous standards can be used. The linearity of this method for analyzing standard solution has been investigated over the range 5-1000 ng mL−1 for both PDMS/DVB and CW/TPR fibers. All the correlation coefficients in the range 5-1000 ng mL−1 were better than 0.995 except Simazine and Atratone by CW/TPR fiber. The R.S.D.s range from 4.4% to 8.8 % (PDMS/DVB fiber) and from 2.4% to 7.2% (CW/TPR fiber). Method-detection limits (MDL) are in the range 1.2-2.6 and 2.8-3.4 ng mL−1 for the two fibers. These methods were applied to the determination of trazines in environmental water samples (lake water).  相似文献   

10.
A stir bar sorptive extraction-gas chromatography-mass spectrometry (SBSE-GC-MS) method for the determination of tetramethylene disulfotetramine is presented. The limits of detection (LOD) of the optimized method was 0.2 ng g−1 for extractions from water and 0.3-2.1 ng g−1 for extractions from foods. Recovery was highly matrix dependent (36-130%) and quantification required standard addition calibrations. Standard addition calibration lines had high linearity (R2 > 0.97) and replicate extractions had good reproducibility (R.S.D. = 4.4-9.8%). A comparison of the SBSE method and a previously developed headspace (HS)-solid-phase microextraction (SPME) method was performed. Generally, SBSE provided higher sensitivity with decreased analysis time.  相似文献   

11.
Chen L  Chen W  Ma C  Du D  Chen X 《Talanta》2011,84(1):104-108
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL−1 for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL−1), and detection limits were within the range 0.12-0.43 ng mL−1. The recoveries of the pyrethroids spiked in water samples at 10 ng mL−1 ranged from 83 to 112%.  相似文献   

12.
A novel sample preparation method, vial wall sorptive extraction (VWSE), which uses a vial whose internal wall is coated with polydimethylsiloxane (PDMS), was developed. The method was applied to the determination of progesterone in human serum sample. Human serum sample (0.5 mL) spiked with progesterone-13C2 was pipetted into the VWSE device and vortex mixing was performed for 30 min. Then, the serum sample was removed and the vial rinsed with purified water. Fifty microliter of methanol as liquid desorption (LD) solvent was pipetted into the VWSE device and vortex mixing was performed for 10 min. Then, the extract was analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The correlation coefficient (r) of the calibration curve over the concentration range of 0.5–200 ng mL−1 was 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.1 and 0.5 ng mL−1, respectively. The relative recoveries were 97.9% (RSD: 4.4%, n = 6) and 102.8% (RSD: 1.1%, n = 6) for progesterone spiked at 5 and 50 ng mL−1, respectively. This simple, accurate, sensitive, and selective analytical method is applicable to the trace analysis of a minute amount of sample.  相似文献   

13.
Silicone rods with a diameter of 1 mm and 10 mm long were used to extract polycyclic aromatic hydrocarbons (PAHs) from water samples and for the rapid screening of highly contaminated waste material. The rods were placed in a 15 ml glass vial for the extraction of the analytes, which involved shaking (300 min−1) the sample for 3 h. After extraction the rods were placed into 250 μl inserts of 2 ml vials filled with 100 μl of an acetonitrile-water mixture (4:1) and desorption was performed with sonication for 10 min. Then the PAHs were determined using LC and fluorescence detection. Recoveries of the rod extraction ranged between 62 and 97% and the detection limits were between 0.1 and 1.2 ng l−1. These results are comparable with those of stir bar sorptive extraction (SBSE). Although the rods are reusable, their low price means they can be discarded if contaminated, eliminating the need for expensive cleaning. One disadvantage compared to SBSE is the longer extraction time needed to reach equilibrium.  相似文献   

14.
Three preconcentration techniques including solid phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and stir-bar sorptive extraction (SBSE) have been optimized and compared for the analysis of six hypolipidaemic statin drugs (atorvastatin, fluvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin) in wastewater and river water samples by high performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry (HPLC/Q-TOF-MS). Parameters that affect the efficiency of the different extraction methods such as solid phase material, sample pH and elution solvent in the case of SPE; the type and volume of the extracting and dispersive solvent, pH of sample, salt addition and number of extraction steps in the case of DLLME; and the stirring time, pH of sample, sample volume and salt addition for SBSE were evaluated. SPE allowed the best recoveries for most of the analytes. Pravastatin was poorly extracted by DLLME and could not be determined. SBSE was only applicable for lovastatin and simvastatin. However, despite the limitations of having poorer recovery than SPE, DLLME and SBSE offered some advantages because they are simple, require low organic solvent volumes and present low matrix effects. DLLME required less time of analysis, and for SBSE the stir-bar was re-usable. SPE, DLLME and SBSE provided method detection limits in the range of 0.04-11.2 ng L−1, 0.10-17.0 ng L−1 for 0.52-2.00 ng L−1, respectively, in real samples. To investigate and compare their applicability, SPE, DLLME and SBSE procedures were applied to the detection of statin drugs in effluent wastewater and river samples.  相似文献   

15.
The determination of a group of eighteen pollutants in waters, including polycyclic aromatic hydrocarbons and substituted phenols, is conducted in direct-immersion solid-phase microextraction (SPME) using the polymeric ionic liquid (PIL) poly(1-vinyl-3-hexadecylimidazolium) bis[(trifluoromethyl)sulfonyl]imide as a novel coating material. The performance of the PIL fiber coating in the developed IL-SPME-gas chromatography (GC)–mass spectrometry (MS) method is characterized by average relative recoveries of 92.5% for deionized waters and 90.8% for well waters, average precision values (as relative standard deviations, RSD%) of 11% for deionized waters and 12% for well waters, using a spiked level of 5 ng mL−1. The detection limits oscillate from 0.005 ng mL−1 for fluoranthene to 4.4 ng mL−1 for 4-chloro-3-methylphenol, when using an extraction time of 60 min with 20 mL of aqueous sample. The extraction capabilities of the PIL fiber have been compared with the commercial SPME coatings: polydimethylsyloxane (PDMS) 30 μm, PDMS 100 μm and polyacrylate (PA) 85 μm. The PIL fiber is superior to the PDMS 30 μm for all analytes studied. A qualitative study was also carried out to compare among the nature of the coating materials by normalizing the coating thickness. The PIL material was shown to be more efficient than the PDMS material for all analytes studied. The PIL coating was also adequate for nonpolar analytes whereas the PA material was more sensitive for polar compounds.  相似文献   

16.
This paper describes the validation of a method for the determination of 24 priority substances from the European Framework Directive in estuarine and sea water using the new extraction technique known as stir bar sorptive extraction (SBSE), followed by thermal desorption using capillary gas chromatography-mass spectrometry. We studied linearity, detection and quantitation limits and accuracy (which includes determination of trueness and precision). Using the lack-of-fit method we tested linearity in the 0-200 ng L−1 range for all the priority substances. The detection and quantification limits were less than 5 and 10 ng L−1, respectively, for most of the compounds studied. Precision was assessed by variance analysis (ANOVA) and relative standard values of less than 10% were obtained for repeatability and less than 15% for intermediate precision. The recovery percentages in spiked estuarine and sea water were close to 100%. Finally, for quality control of the method (stability of precision and accuracy through time), we developed a method for calculating Shewhart control charts based on the information obtained in the validation process.  相似文献   

17.
A carbon monolith was synthesized via a polymerization–carbonization method, styrene and divinylbenzene being adopted as precursors and dodecanol as a porogen during polymerization. The resultant monolith had bimodal porous substructure, narrowly distributed nano skeleton pores and uniform textural pores or throughpores. The carbon monolith was directly used as an extracting fiber, taking place of the coated silica fibers in commercially available solid-phase microextraction device, for the extraction of phenols followed by gas chromatography–mass spectrometry. Under the studied conditions, the calibration curves were linear from 0.5 to 50 ng mL−1 for phenol, o-nitrophenol, 2,4-dichlorophenol and p-chlorophenol. The limits of detection were between 0.04 and 0.43 ng mL−1. The recoveries of the phenols spiked in real water samples at 10 ng mL−1 were between 85% and 98% with the relative standard deviations below 10%. Compared with the commercial coated ones (e.g. PDMS, CW/DVB and DVB/CAR/PDMS), the carbon monolith-based fiber had advantages of faster extraction equilibrium and higher extraction capacity due to the superior pore connectivity and pore openness resulting from its bimodal porous substructure.  相似文献   

18.
A new and sensitive analytical method based on the recently developed approach termed stir bar-sorptive dispersive microextraction (SBSDME) using a magnetic CoFe2O4@SiO2–nylon 6 composite as sorbent material is presented for the extraction of hydrophilic organic compounds. The simultaneous determination of four hydrophilic UV filters in environmental water samples has been chosen as a model analytical application due to the increasing awareness regarding the occurrence of sunscreen residuals in natural waters. The developed SBSDME approach combines the principles and benefits of stir bar sorptive extraction (SBSE) and dispersive solid phase extraction (DSPE) but allows for lower extraction time and easier post-extraction treatment. Moreover, most importantly, it enables the use of new magnetic materials that affords higher versatility and can be tailored to the needs of the analysis. The main experimental parameters involved in the SBSDME process (i.e. composite amount, extraction time, pH, ionic strength, desorption solvent and desorption time) were evaluated to provide the best enrichment factors. Under the optimized conditions, the method was successfully validated showing good linearity, enrichment factors between 105 and 145 depending on the analyte, limits of detection and quantification in the low ng mL−1 range (1.6–2.9 ng mL−1 and 5.4–9.6 ng mL−1, respectively) and good intra- and inter-day repeatability (RSD < 13%). The developed method was applied to the analysis of water samples of different origin (sea, river and swimming pool). Relative recovery values ranged between 90 and 115%, thus showing that the matrices under consideration do not affect the extraction process.  相似文献   

19.
The hollow fiber-based stirring extraction bar liquid–liquid microextraction was applied to the extraction of hormones, including 17-α-ethinylestradiol, 17-α-estradiol, estriol, 17-β-estradiol, estrone, 17-α-hydroxyprogesterone, medroxyprogesterone, progesterone and norethisterone acetate, in milk. The present method has the advantages of both hollow fiber-liquid phase microextraction and stirring bar sorptive extraction. The stirring extraction bar was used as both the stirring bar of microextraction, and extractor of the analytes, which can make extraction, clean-up and concentration be carried out in one step. When the extraction was completed, the stirring extraction bar was easy isolated from the extraction system with the magnet. Several experimental parameters, including the type of extraction solvent, the number of hollow stirring extraction bar, extraction time, stirring speed, ionic strength, and desorption conditions were investigated and optimized. The analytes in the extract were derived and determined by gas chromatography mass spectrometry. Under optimal experimental conditions, good linearity was observed in the range of 0.20–20.00 ng mL−1. The limits of detection and quantification were in the range of 0.02–0.06 ng mL−1 and 0.07–0.19 ng mL−1, respectively. The present method was applied to the analysis of milk samples, and the recoveries of analytes were in the range of 93.6–104.6% with the relative standard deviations ranging from 1.6% to 6.2% (n = 5). The results showed that the present method was a rapid and feasible method for the determination of hormones in milk samples.  相似文献   

20.
Polyclonal antibody (PAb) with broad-specificity for O,O-diethyl organophosphorus pesticides (OPs) against a generic hapten, 4-(diethoxyphosphorothioyloxy)benzoic acid, was produced. The obtained PAb showed high sensitivity to seven commonly used O,O-diethyl OPs in a competitive indirect enzyme-linked immunosorbent assay (ciELISA) using a heterologous coating antigen, 4-(3-(diethoxyphosphorothioyloxy)phenylamino)-4-oxobutanoic acid. The 50% inhibition value (IC50) was 348 ng mL−1 for parathion, 13 ng mL−1 for coumaphos, 22 ng mL−1 for quinalphos, 35 ng mL−1 for triazophos, 751 ng mL−1 for phorate, 850 ng mL−1 for dichlofenthion, and 1301 ng mL−1 for phoxim. The limit of detection (LOD) met the ideal detection criteria of all the seven OP residues. A quantitative structure-activity relationship (QSAR) model was constructed to study the mechanism of antibody recognition using multiple linear regression analysis. The results indicated that the frontier-orbital energies (energy of the highest occupied molecular orbital, EHOMO, and energy of the lowest unoccupied molecular orbital, ELUMO) and hydrophobicity (log of the octanol/water partition coefficient, log P) were mainly responsible for the antibody recognition. The linear equation was log(IC50) = −63.274EHOMO + 15.985ELUMO + 0.556 log P − 25.015, with a determination coefficient (r2) of 0.908.  相似文献   