首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ochratoxin A (OTA) is a mycotoxin produced by some species of Aspergillus and Penicillium verrucosum. It has been found in foods and feed all over the world. There is a great concern about OTA because it is nephrotoxic and probably, carcinogenic to humans. Most of analytical methods developed for OTA in wine, beer and other products are based on LC with fluorescence detection (LC-FLD). In the present work, various procedures for extraction and/or clean-up for determination of OTA in musts, wine and beer by LC-FLD were compared: (1) dilution with polyethylen glycol 8000 and NaHCO3 solution and clean-up an on immunoaffinity column (IAC); (2) extraction with chloroform and IAC clean-up; solid-phase extraction (SPE) on (3) reversed-phase (RP) C18; (4) RP phenylsilane and (5) Oasis HLB cartridges. SPE on phenylsilane and Oasis HLB have not been reported for OTA analysis in beverages. The same LC-FLD conditions and concentration ratio were used. The former procedure was simple, rapid and provided flat baselines, free from most impurity peaks, high OTA recoveries and quite repeatable results. RP C18 using methanol-acetic acid (99.5:0.5) as elution solvent provided good recoveries and precision, thus becoming a cheaper but interesting alternative at 0.1-1 ng/ml spiking levels. Oasis HLB cartridges were usually better than phenylsilane. Possible binding of OTA to proteins or other components was tested by acid treatment before extraction but no significant differences with controls appeared.  相似文献   

2.
Three immunoaffinity clean-up procedures to analyse ochratoxin A (OTA) in wines were compared. The direct wine clean-up with Ochraprep and OchraTest columns gave equivalent results in terms of recovery and precision if compared with the reference procedure involving a preliminary extraction of OTA with chloroform. OTA quantification limit in wine ranged from 0.020 to 0.045 microg/l. The 'on-flow' OTA emission spectrum (excitation 333 nm) showed a maximum at 460 nm and could be used to confirm the quantitative results. The analysis of 11 red and white wines gave no significant quantitative differences between the three clean-up techniques.  相似文献   

3.
Comparison of methods for the determination of ochratoxin A in wine   总被引:2,自引:0,他引:2  
Different analytical methods for the determination of ochratoxin A (OTA) in wine have been compared. Sample clean-up was based on solid-phase extraction (SPE) with (i) immunoaffinity or (ii) RP-18 sorbent materials applying different experimental protocols. The detection of OTA was accomplished with high-performance liquid chromatography (HPLC) combined either with electrospray ionisation (ESI) tandem mass spectrometry (MS-MS) or fluorescence detection (FL). Comparative method evaluation was based on the investigation of 18 naturally contaminated red wine samples originating from different European countries. The analytical results are discussed in view of the respective method validation data and the corresponding experimental protocols. In general, analytical data obtained with RP-18 SPE combined with LC-MS-MS detection and immunoaffinity extraction combined with FL offered comparable good results in the sub-ppb concentration level indicating that high selectivity of either the sample clean-up or, alternatively the detection system are equally well-suited to guarantee an accurate OTA analysis in wine.  相似文献   

4.
Some Spanish sweet wines are made from raisins, grapes dried by direct exposure to the sun after picking. This drying process can encourage ochratoxin A (OTA) formation. OTA is a mycotoxin formed by several fungi. It has been linked to nephropathy in humans, and may have a long half-life in humans. The aim of this study is to develop and to apply two procedures for the analysis of OTA in grape musts (during the raisining process) and sweet wines, respectively. Reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to fluorescence detection (FLD) was employed in both analytical methods. In grape must, the method involves the direct injection of the sample in a HPLC-FLD system without any kind of prior clean-up procedure. The complexity of the sweet wine samples requires a solid-phase extraction (SPE) clean-up on a C18 column which enables the OTA to be isolated from the matrix. The methods used were statistically validated. The validation also included the comparison of the slopes of the curve obtained with standards and the regression curves obtained by the addition of a standard. Two different studies of standard additions were conducted. One method was validated without sample preparation and it was applied to must samples. The other method was validated with SPE extraction and it was applied to sweet wine samples. Recovery was always better than 89.69%. The limit of detection (S/N = 3) and limit of quantification (S/N = 10) were established at 0.22 and 0.77 μg l−1, respectively. In general, the analytical data obtained provided good results at the sub-μg l−1 concentration level.  相似文献   

5.
We present a comparison of two sensitive methods, HPLC with fluorescence detector (HPLC/FLD) and UPLC with electrospray tandem mass spectrometry (UPLC/MS/MS), for the determination of indoleamine neurotransmitters (NTs) and their metabolites in sea lamprey plasma samples. Liquid–liquid extraction (LLE) and solid-phase extraction (SPE) were also tested for recovery and matrix effect. The recoveries of SPE determined by HPLC/FLD and UPLC/MS/MS ranged from 75 to 123% and 78 to 105%, respectively, while the recoveries of LLE ranged from 45 to 73% and 48 to 75%, respectively. SPE combined with HPLC/FLD and UPLC/MS/MS to determine the target analytes in plasma samples were validated of the sensitivity, reproducibility, accuracy and precision. Both methods exhibited excellent linearity in the range of 0.2–50 ng mL−1 for all analytes. The limits of detection (LOD) varied from 0.04 ng mL−1 to 0.13 ng mL−1 for HPLC/FLD method and 0.003 ng mL−1 to 0.02 ng mL−1 for UPLC/MS/MS method. The inter-day accuracy ranged from 82.5 to 127.0% for HPLC/FLD and 93.0 to 113.0% for UPLC/MS/MS. The inter-day precision ranged from 9.9 to 32.3% for HPLC/FLD and 5.4 to 13.2% for UPLC/MS/MS. These results demonstrated that the values obtained by both methods were within the satisfactory range and the UPLC/MS/MS method provided more accurate and precise measurements than HPLC/FLD method. The comparison is of great importance to determine the available detectors, considering the complexity and expensiveness versus quality parameters. These two methods were applied to the analysis of four important indoleamine neurotransmitter analytes (5-hydroxytryptamine, 5-hydroxyindole-3-acetic acid, tryptamine and melatonin) in sea lamprey plasma samples.  相似文献   

6.
Various solid-phase extraction (SPE) procedures for clean-up, two perfluoroacylation reagents (pentafluoropropionic anhydride (PFPA) and heptafluorobutyric anhydride (HFBA)) and two chromatographic columns (HP-1701 and HP-5) have been assessed comparatively to achieve the determination of type B trichothecenes (deoxynivalenol (DON), nivalenol (NIV), 3- and 15-acetyldeoxynivalenol (3- and 15-ADON)) in wheat grain by gas chromatography (GC)-electron-capture detection (ECD). Spiked wheat samples were extracted with acetonitrile-water (84:16, v/v). Tested SPE procedures were MycoSep 225 column, Florisil and different cartridges prepared in the laboratory with mixtures of various sorbents like alumina, Celite 545, C18, silica and charcoal. We propose MycoSep 225 column, and cartridges made with alumina-charcoal-silica and alumina-charcoal-C18 silica mixtures as clean-up procedures on the basis of recovery values (89.6, 87.3 and 86.1% for deoxynivalenol, respectively, at 1.0 mg/kg spiking level). The two last procedures are less expensive. Pentafluoropropionic anhydride was more stable against moisture and less expensive, while recoveries were similar to those obtained with heptafluorobutyric anhydride. HP-1701 column can separate 3- and 15-acetyldeoxynivalenol derivatives while HP-5 cannot, although this last column provided lower bleed and better sensitivity.  相似文献   

7.
Rodenticides are used as pest control to eradicate rodents and have emerged as new environmental contaminants due to their widespread use in domestic and urban infrastructures. In this study, we have developed and validated an analytical methodology based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of 13 anticoagulant rodenticides in wastewater. In a first step, ionization conditions were tested in electrospray mode, and positive ionization gave the highest sensitivity. Fragmentation patterns were determined and two selected reaction monitoring (SRM) transitions were selected for each compound. Using a Zorbax Eclipse XDB-C18 column and specific SRM transitions, 13 compounds were resolved. The LC-MS/MS method provided good linearity, sensitivity, intra- and inter-day precision, and good identification capabilities for these compounds in wastewaters. Thereafter miniaturized liquid–liquid extraction (LLE) and solid-phase extraction (SPE) were optimized. Oasis HLB and Strata WA SPE cartridges with methanol/dichloromethane as eluting solvents provided good recoveries and limits of detection ranged between 0.34 and 20 ng L?1, whereas LLE failed to recover some compounds. Finally, the performance of both LLE and SPE methods was evaluated by analyzing rodenticides in a set of wastewaters. Warfarin was the only detected compound at nanogram per liter level, and good agreement was observed between LLE and SPE.  相似文献   

8.
Three different clean-up methods for the analysis of deoxynivalenol in cereals and cereal-based foods are described and compared. DON was extracted with water or acetonitrile/water (84/16, v/v) and the extracts were cleaned-up by passing either through two different immunoaffinity columns (DONtest, Vicam; DONPrep, Rhone) or a charcoal/alumina column (MycoSep, Romer Labs). Determinative analysis was performed by high performance liquid chromatography (HPLC) with diode array detection (DAD) and fluorescenic detection (FLD) after post-column derivatisation. Different parameters were optimised and possible reasons for diverse results are discussed. The final method was validated and adopted to different matrices. Best results were obtained using immunoaffinity columns for clean-up in combination with HPLC-FLD detection of the DON-derivative.  相似文献   

9.
Ochratoxin A (OTA) exhibits potent nephrotoxic, carcinogenic and teratogenic effects and its maximum level in wines has been set to 2 μg L−1 by regulation. Consequently, the analytical procedures for OTA determination in wines have to be both very sensitive and reliable. In this paper, we compared two quantification methods: the stable isotope dilution assay (SIDA) and the diastereomeric dilution assay (DIDA). For this purpose, non-natural analogues of OTA were synthesized: the labeled OTA (OTA-d4) as a diastereomeric mixture for the SIDA and one non-natural OTA’s diastereomer (OTA-dia) for the DIDA. To quantify OTA in red grapes, musts or wines, the sample preparation was optimized using immunoaffinity column extraction and the analysis was performed by LC–MS/MS in Multiple Reaction Monitoring mode. A validation procedure in agreement with the International Organization of Vine and Wine recommendations was conducted. It appeared that SIDA quantification exhibited excellent sensitivity (LOD < 1 ng L−1), accuracy (recovery = 98%), repeatability (RSD < 3%) and intermediate reproducibility (RSD < 4%) compared to quantification by DIDA. Indeed, DIDA method did not provide satisfactory results demonstrating that immunoaffinity extraction is exclusively selective for the natural OTA and not for its diastereomer, which therefore cannot be considered as a good internal standard for this particular method.  相似文献   

10.
Ochratoxin A (OTA) is a mycotoxin produced by fungi species belonging to the genera Aspergillus and Penicillium being isolated in alcoholic beverages. The aim of this work is developed and applied a procedure for the analysis of OTA in wines. An analytical method based on immunoaffinity column (IAC) for clean-up, liquid chromatography with fluorescence detection (LC-FD), and LC-FD after of OTA methylation was used to determine the occurrence of OTA in wines. Recoveries of this mycotoxin spiked to red wines at 0.5 ng/ml level were >90% with an average of relative standards deviations of 4%. Furthermore, 116 wine samples from designation of origin (DO) and three samples from food stores of Valencian Community (Spain) were examined for the occurrence of OTA being the levels of this mycotoxin ranged from <0.01 to 0.76 ng/ml. Finally, the estimated daily intake of OTA in this study was 0.15 ng/kg bw per day.  相似文献   

11.
Gel-based and membrane-based flow-through immunoassay formats were investigated for rapid ochratoxin A (OTA) detection in red wine. The flow-through set-up consisted of an antibody containing gel or membrane placed at the bottom of a standard solid-phase extraction column (i.e. the flow-through column), combined with a clean-up column. Different clean-up methods were studied for red wine clarification and purification. The optimal method consisted of passing wine, diluted with an aqueous solution containing 1% polyethylene glycol (PEG 6000) and 5% sodium hydrogencarbonate, through strong anion exchange (SAX) silica. An immunoassay for OTA detection in red wine was optimized and a cut-off level at 2 μg L−1 according to EU legislation was achieved with both formats. A more significant colour difference between blank and spiked samples was observed for the gel-based assay making this superior to the membrane-based assay. The proposed rapid gel-based test was compared with a standard immunoaffinity column - high-performance liquid chromatography - fluorescent detection (IAC-HPLC-FLD) method and a good correlation of the results was obtained for naturally contaminated wine samples.  相似文献   

12.
Different extraction and clean-up techniques used before HPLC analysis were compared in order to obtain a reliable method for the quantitative determination of zearalenone (ZEA) and α-zearalenol (α-ZOL) in animal feed. Immunoaffinity clean-up was compared to C18 and Florisil column clean-up. Extracted samples were analysed by reversed-phase HPLC with fluorescence detection (λex=274 nm, λem=440 nm). A mobile phase of acetonitrile:water (50:50 (v/v)) and a flow-rate of 1.0 ml min−1 resulted in a good separation between ZEA and α-ZOL. Using immunoaffinity clean-up the linear range was between 25 and 600 μg kg−1 for ZEA and α-ZOL in maize. Intra-laboratory coefficients of variation (CV) (under repeatability conditions) were 9.16% for ZEA and 2.18% for α-ZOL. Recoveries for spiked ZEA and α-ZOL samples ranged from 89 to 110% with CVs between 5.2 and 11.2% (under within-laboratory reproducibility conditions). Using C18 and Florisil solid-phase clean-up, matrix interference was too high. Therefore, naturally contaminated animal feed samples were analysed using the developed HPLC method coupled to the immunoaffinity clean-up.  相似文献   

13.
A fluorescence polarization (FP) immunoassay, based on a monoclonal antibody and an ochratoxin A (OTA)-fluorescein tracer, has been developed for rapid screening of OTA in red wine. Wine samples were diluted with methanol and passed through aminopropyl solid-phase extraction columns prior to the FP assay. Average recoveries from samples spiked with OTA at levels of 2.0 and 5.0 ng/mL were 79% with RDS of 11% (n = 6). The limit of detection of the FP immunoassay was 0.7 ng/mL OTA, and the whole analysis was performed in less than 10 min. The assay was tested on 154 red wine samples (naturally contaminated or spiked at level ranging from 0.1 to 5.0 ng/mL) and compared with an high-performance liquid chromatography/immunoaffinity column clean-up method, showing a good correlation (r = 0.9222). Their compliance with the European regulation (2.0 ng/mL OTA maximum permitted level) was correctly assessed for 70% of the analyzed samples of red wine, whereas confirmatory analyses were required for the remaining ones with OTA levels close to the regulatory limit. No false-negative or positive results were observed using the FP immunoassay. The proposed FP assay is a useful screening method for OTA in red wines, when high throughput is required, that could also be used for white and rosé wines, which are known to contain less interfering compounds such as polyphenols.  相似文献   

14.
A simple, reliable, and low‐cost method based on molecularly imprinted polymer as a selective sorbent of SPE was proposed for the determination of ochratoxin A (OTA) in beer, red wine, and grape juice by HPLC coupled with fluorescence detection (HPLC‐FLD). Samples were diluted with water and cleaned up with an AFFINIMIP® SPE OTA column. After washing and eluting, the analyte was analyzed by HPLC‐FLD. Under the optimized conditions, LOD and LOQ for OTA were 0.025 and 0.08 ng/mL, respectively. The recoveries of OTA from beer, red wine, and grape spiked at 0.1, 2, and 5 ng/mL ranged from 91.6 to 101.7%. Furthermore, after a simple regenerated procedure, the molecularly imprinted polymer based SPE column could be reused at least 14 times to achieve more than 80% recoveries of OTA in real samples. The developed method was applied to the detection of 30 beer, red wine, and grape juice samples and only four samples were contaminated by OTA with levels below the legal limits.  相似文献   

15.
To evaluate a clean-up method of detecting ochratoxin A (OTA) by HPLC, the performances of two different clean-up columns, an immunoaffinity column and a multifuntional column were compared in an inter-laboratory study. As samples, un-contaminated wheat, corn grits, green coffee beans and naturally contaminated raisins were used. The recovery test was performed at two different concentrations of OTA (0.5 and 5.0 μg/kg) except for naturally contaminated raisins. Using the immunoaffinity column, the recovery rates, and relative standard deviations for repeatability (R.S.D.r) and reproducibility (R.S.D.R) for wheat, corn grits and green coffee beans ranged 59.0-85.8, 4.2-7.8 and 22.9-29.2%, respectively. For naturally contaminated raisins, recovery, R.S.D.r and R.S.D.R were 84.1, 1.8 and 5.1%, respectively. Using the multifunctional column, the recovery rates, R.S.D.r and R.S.D.R for wheat, corn grits and green coffee beans ranged 80.8-185.0, 0.7-6.9 and 15.2-33.9%, respectively. For naturally contaminated raisins, the recovery, R.S.D.r and R.S.D.R were 128.7, 1.1 and 3.7%, respectively. The results suggest that a multifunctional column could be used to detect OTA in wheat and corn grits at a concentration as low as 0.5 μg/kg; however, it was difficult to detect OTA in green coffee beans and raisins at such a low level. Although an immunoaffinity column could be used for all the test samples in this study from a low level to a high level, the recovery rates were lower than with a multifunctional column.  相似文献   

16.
A new and accurate method to quantify ochratoxin A (OA) in table wine has been developed. The method uses commercial immunoaffinity columns for clean-up and high-performance liquid chromatography (HPLC) with fluorescence detection for quantification of the toxin. Wine was diluted with a solution containing 1% polyethylene glycol (PEG 8000) and 5% sodium hydrogencarbonate, filtered and applied to an OchraTest immunoaffinity column. The column was washed with a solution containing sodium chloride (2.5%) and sodium hydrogencarbonate (0.5%) followed by water. OA was eluted with methanol and quantified by reversed-phase HPLC with fluorometric detection (excitation wavelength 333 nm, emission wavelength 460 nm) using acetonitrile-water-acetic acid (99:99:2) as mobile phase. Average recoveries of OA from white, rosé and red wine samples spiked at levels from 0.04 to 10 ng/ml ranged from 88% to 103%, with relative standard deviations (RSDs) between 0.2 and 9.7%. Detection limit was 0.01 ng/ml based on a signal-to-noise ratio of 3:1. The method was applied successfully to 56 samples of red (38), rosé (8), white (9) and dessert (1) wine. The levels of OA ranged from <0.01 to 7.6 ng/ml with red wines more contaminated than rosé and white wines. A good correlation (r=0.987) was found by comparative analysis of 20 naturally contaminated samples using this method and the method of Zimmerli and Dick with better recoveries of OA and better performances for the new method. Several advantages of this method with respect to the actually available methods have been pointed out, with particular reference to red wine which appears to be the most difficult to analyze.  相似文献   

17.
Ochratoxin A (OTA) is a mycotoxin (potentially carcinogenic secondary metabolite derived from fungal contamination), produced by some Aspergillus and Penicillium strains. Although present and legislated in different food sources in the human diet, the regulation for wine intake is still under discussion. The Office International de la Vigne et du Vin (OIV) recommended maximum levels in wine of 2 μg l−1. Some reports refer to OTA contamination in wines up to 15 μg l−1 and a special incidence in red wines from the southern regions of Europe and the north of Africa, but the majority of the data available are below 1 μg l−1. When working at such low concentrations, the problem of the uncertainty of the results becomes decisive towards the implementation of legal limits. In order to assess the global uncertainty associated with OTA determination in wines and widen the data set and knowledge of the situation in Portugal, 340 wines were analysed (189 Port Wine, 85 Vinho Verde and 66 wines from other regions in the country) by a high performance liquid chromatography (HPLC)-fluorescence detection (FD) method using immunoaffinity columns for clean up. OTA was detected in 69 wines by the method used, but in concentrations below 0.5 μg l−1, except for two which showed levels up to a maximum of 2.1 μg l−1. However, the global uncertainty for OTA is close to 37% for concentrations above 0.5 μg l−1, and therefore, such value can be below or exceed the OIV limit. In the vicinity of the limit of detection, 0.084 μg l−1, the global uncertainty rises exponentially to a maximum of about 70%. This can be an obstacle when discussing safety intake limits. Ethanol and glucose content did not interfere in the clean up of OTA by immunoaffinity columns.  相似文献   

18.
The aim of this work was to develop a method for the clean-up of a mycotoxin, i.e. Ochratoxin A (OTA), from cereal extracts employing a new molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE) and to compare with an immunoaffinity column. A first series of experiments was carried out in pure solvents to estimate the potential of the imprinted sorbent in terms of selectivity studying the retention of OTA on the MIP and on a non-imprinted polymer using conventional crushed monolith. The selectivity of the MIP was also checked by its application to wheat extracts. Then, after this feasibility study, two different formats of MIP: crushed monolith and micro-beads were evaluated and compared. Therefore an optimization procedure was applied to the selective extraction from wheat using the MIP beads. The whole procedure was validated by applying it to wheat extract spiked by OTA at different concentration levels and then to a certified contaminated wheat sample. Recoveries close to 100% were obtained. The high selectivity brought by the MIP was compared to the selectivity by an immunoaffinity cartridge for the clean-up of the same wheat sample. The study of capacity of both showed a significant higher capacity of the MIP.  相似文献   

19.
建立了固相萃取-高效液相色谱(SPE-HPLC)测定葡萄酒中白藜芦醇及其糖苷异构体的方法,并用此方法测定了市售的15种葡萄酒中顺反式白藜芦醇及其糖苷的含量。实验确定了葡萄酒样品中的白藜芦醇及其糖苷的固相萃取方法,通过优化萃取条件,有效地去除了葡萄酒中大量干扰成分。采用Hypersil C18柱(4.6 mm i.d.×250 mm,5μm)分离,以乙腈-水为流动相,线性梯度洗脱,用二极管阵列检测器分别于288 nm和306 nm波长下检测,4种组分分离良好,提高了分析结果的准确性。采用外标法定量,4种组分的质量浓度与其峰面积在一定的范围内有良好的线性关系,相关系数为0.9973~0.9999。4种组分的平均加标回收率为97.4%~98.8%(相对标准偏差为2.1%~3.2%),检测限为0.002~0.005 mg/L。对市售15种葡萄酒的检测结果表明,白藜芦醇作为葡萄酒中重要的生物活性成分,其含量与葡萄酒的酿造方式、葡萄品种、葡萄产地有密切的关系。该方法还可用于其他天然产物中白藜芦醇及其糖苷异构体的测定。  相似文献   

20.
Various liquid chromatographic methods used in the analysis of mycotoxins (zearalenone, trichothecenes and fumonisins) produced by Fusarium species were compared in this work. The results demonstrate the suitability of modern clean-up procedures employing multifunctional MycoSep and immunoaffinity columns although these methods are more expensive than conventional methodologies for clean-up. HPLC with both fluorescence and photodiode array detection is a suitable technique for the analysis of toxic secondary metabolites produced by Fusarium species; different derivatisation strategies have been studied to improve the sensitivity of the technique because of the low concentration of these metabolites in contaminated food. The utility of the proposed methodology was assessed in cereal cultures of various Fusarium strains.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号