1.
A flow analysis method with on-line sample digestion/minicolumn preconcentration/flame atomic absorption spectrometry is described for the determination of trace metals in urine. First, urine sample was on-line ultrasound-assisted digested exploiting the stopped-flow mode, and then the metals were preconcentrated passing the pre-treated sample through a minicolumn containing a chelating resin. A home-made minicolumn of commercially available imminodiacetic functional group resin, Chelite Che was used to preconcentrate trace metals (Cu, Fe, Mn and Ni) from urine. The proposed procedure allowed the determination of the metals with detection limits of 0.5, 1.1, 0.8 and 0.8 μg L−1, for Cu, Fe, Mn and Ni, respectively. The precision based on replicate analysis was less than ±10.0%, and the enrichment factor obtained was between 21.3 (Mn) and 44.1 (Ni), for sample volumes between 2.5 and 5.0 mL, and an eluent volume of 110 μL. This procedure was applied for determination of metals in urine of workers exposed to welding fumes and urine of unexposed persons (urine control).  相似文献   

2.
In this work, bamboo charcoal (BC) was used as a sorbent for on-line solid phase extraction (SPE) coupling with flame atomic absorption spectrometry (AAS) for trace copper and zinc determination in environmental and biological samples. Under the optimum pH of 5.5 (for Zn) and 7.0 (for Cu), trace copper and zinc were effectively adsorbed on the microcolumn and the retained cations were efficiently eluted with HCl or HNO3 with an appropriate concentration and flow rate for on-line AAS determination. With a sample loading time of 60 s at a sample flow rate of 7.6 mL min?1, the enhancement factors of 39 (for Cu) and 30 (for Zn) and detection limits (3σ) of 0.60 µg L?1 (for Cu) and 0.36 µg L?1 (for Zn), respectively, were achieved. The sample throughput was 45 h?1. At the level of 20 µg L?1of Cu(II) and Zn(II), the precision (RSD, n?=?11) were found to be 0.26% and 1.6%, respectively. The proposed method has been successfully applied to the determination of copper and zinc in environmental and biological samples.  相似文献   

3.
Three automated flow-injection systems are proposed for the determination of traces of manganese(II), lead and copper(II) in waters. The first system utilizes the catalytic effect of manganese(II) on the oxidation of N,N-diethylaniline by potassium periodate at pH 6.86–7.10 (30°C) and is used for spectrophotometric determination at 475 nm in the range 0.02–1.00 μg1?1; the system involves reagent injection and stopped flow. The determination of lead in the range 0.7–100 μg1?1 is based on spectrophotometric detection of the lead 4/(2-pyridylazo)resorcinol complex at 525 nm after on-line preconcentration of the sample (5–50 ml) on a minicolumn filled with Chelex-100 or Dowex 1-X8 resin. A potentiometric flow-injection system with a copper ion-selective electrode is applied for the determination of 0.5–1000 μg 1?1 copper(II) after on-line preconcentration of 50–500 ml of sample on Chelex-100 resin. The procedures are tested on synthetic and real water samples, including sea water and waste-waters.  相似文献   

4.
A flow-injection system is developed for Cu, Mn and Zn partitioning in seawater by flame atomic absorption spectrometry. The first approach is where the trace metal species are fractionated in situ, but analysis is performed by using a flow injection manifold in the laboratory. This operational mode is used for the determination of the dissolved labile metallic fraction and is based on the elution of this fraction from a minicolumn packed with a chelating resin containing iminodiacetic acid groups (Serdolit Chelite Che) loaded in situ with the sample. The second is used for the determination of total dissolved concentrations of trace metals. This last mode is based on the retention/preconcentration of total dissolved metals on the chelating resin after on-line sonolysis of seawater samples acidified with diluted nitric acid to breakdown the metal-organic matter complexes. The figures of merit for Cu, Mn and Zn determinations in both fractions are given and the obtained values are discussed. The fractionation scheme is applied to the analysis of coastal seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Mn and Zn are mainly in the labile fraction, while Cu was mainly present in the organic fraction.  相似文献   

5.
A novel dual-syringe flow injection (DSFI) on-line column preconcentration system coupled to flame atomic absorption spectrometry (FAAS) has been developed for automatic trace metal determination in natural waters and biological samples. The proposed method was based on the on-line retention of Cd(II), Pb(II), Cu(II), Co(II) and Ni(II) ions onto the surface of a strong cation exchanger resin named HyperSepSCX, in a readily exchangeable micro-cartridge format and subsequent elution with HCl (2?mol?L?1) prior to flame atomization. The sorbent and the micro-cartridge exhibited high long term chemical and mechanical stability with fast kinetics for all analytes. All main chemical and hydrodynamic factors affecting the performance of the proposed method were studied thoroughly. For 15.0?mL sample volume, the enhancement factors were calculated as 92, 97, 93, 99 and 77 for Cd(II), Pb(II), Cu(II), Co(II) and Ni(II) respectively and the detection limits (3?s) were in the range between 0.14 and 2.1?µg?L?1. The precision (RSD) obtained was lower than 3.3% for all five metal ions with a sample throughput of 12?h?1. The developed method was evaluated by analyzing certified reference materials and spiked environmental natural water samples.  相似文献   

6.
A rapid and simple on-line method is described for the determination of Au(III) in various samples. The method is based on the sorption of gold(III) on Lewatit MonoPlus TP207 chelating resin including the iminodiacetate group, which is used as sorbent material and packed in a minicolumn. The chemical variables such as the pH of the sample solution, eluent type, interfering ions and concentrations of reagents, and instrumental variables such as sample loading volume, reagents flow rates, and tubing length, which affect the efficiency of the method were studied and optimised. Au(III) was sorbed on the chelating resin, from which it could be eluted with 3 mol L?1 HCl, and then introduced directly to the nebuliser-burner system of FAAS. The limit of detection of the method was 0.2 µg L?1 while the relative standard deviation was <4.0% for 20 µg L?1 Au(III) concentration. The preconcentration factor was found to be 106 while the optimised sample volume was 15.3 mL. The accuracy of the method was verified by analysing the certified reference material. The developed method was applied successfully for the determination of gold in different samples with satisfactory results.  相似文献   

7.
《Analytical letters》2012,45(4):632-646
A new solid phase extraction method based on the application of polyaniline as the sorbent and calmagite as the anionic chelating agent is reported for selective preconcentration of trace copper, prior to its determination by microsample injection system-flame atomic absorption spectrometry. The parameters that influence the extraction and chelate formation were optimized. The copper was retained on a polyaniline minicolumn at pH 4.0 and eluted with 2.0 mL of 3.0 mol L?1 nitric acid. Under the optimum conditions, the limit of detection, the relative standard deviation, and the preconcentration factor were 1.98 µg L?1, less than 5.4%, and 50 to 200, respectively. The method was validated through the analysis of certified reference water samples and standard addition measurements. Quantitative recoveries between 93.4% and 103.5% were obtained. The method was successfully applied to the determination of copper in water.  相似文献   

8.
A new sorbent – salen impregnated silica gel – was prepared and characterised for application as a minicolumn packing for flow-injection on-line preconcentration of cadmium(II). The system was coupled with flame atomic absorption spectrometer (FI-FAAS). The optimal pH for Cd(II) sorption was in the range of 7.4–8.8 and nitric acid (1%, v/v) was efficient as eluent. Sorption was most effective within the sample flow rate up to 7?mL?min?1. Sorption capacity of the sorbent found in a batch procedure was 26.3?µmol?g?1 (2.95?mg?g?1). Enrichment factor (EF) and limit of detection (LOD) obtained for 120-second loading time were 113 and 0.26?µg?L?1, respectively. The sorbent stability in the working conditions was proved for at least 100 preconcentration cycles. The evaluated method was applied to Cd(II) determination in various water samples.  相似文献   

9.
A simple and efficient liquid-phase microextraction technique was developed using ultrasound-assisted emulsification solidified floating organic drop microextraction combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of iron and copper in real samples. 2-Mercaptopyridine n-oxide was used as chelating agent and 1-dodecanol was selected as extraction solvent. The factors influencing the complex formation and extraction were optimized. Under optimum conditions, an enrichment factor of ~13 was obtained for both iron and copper from only 6.7 mL of aqueous phase. The analytical curves were linear between 40–800 and 20–1,200 μg L?1 for iron and copper respectively. Based on three SD of the blank, the detection limits were 8.6 and 4.1 μg L?1 for iron and copper respectively. The relative SDs for ten replicate measurements of 500 μg L?1 of metal ions were 2.9 and 1.2 for iron and copper respectively. The proposed method was successfully applied for determination of iron and copper in environmental waters and some food samples including chess, rice, honey and powdered milk. Finally, method validation was made using rock certified reference material. A student’s t test indicated that there was no significant difference between experimental results and certified values.  相似文献   

10.
A method was developed for the on-line determination of palladium in complex matrices with flame atomic absorption spectrometry (FAAS) using Amberlite XAD-16 resin functionalized with 2-[2-(5-thiol-1,3,4-thiadiazolyl)]-azonaphthol (TTAN) reagent. Optimum experimental conditions such as pH of sample, type of eluent, amount of resin, volumes of sample and eluent solution, flow rates of sample and eluent, and effect of interfering ions were established. A 0.1?mol?L?1 thiourea solution in 0.5?mol?L?1 HCl was used as the eluent and subsequently transportation the analyte ions into the nebulizer–burner system for atomization. The synthesized chelating resin material showed excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates without significant losses of retention efficiency. The detection limit of the method was 1.5?µg?L?1 while the relative standard deviation (RSD%) was 2.4% at 0.1?mg?L?1 Pd(II) level. The developed method was successfully applied to the determination of palladium in the catalytic converter and water samples.  相似文献   

11.
《Analytical letters》2012,45(11):2285-2295
Abstract

Multi‐walled carbon nanotubes (MWNTs) were used as sorbent for flow injection (FI) on‐line microcolumn preconcentration coupled with flame atomic absorption spectrometry (FAAS) for determination of trace cadmium and copper in environmental and biological samples. Effective preconcentration of trace cadmium and copper was achieved in a pH range of 4.5–6.5 and 5.0–7.5, respectively. The retained cadmium and copper were efficiently eluted with 0.5 mol L?1 HCl for on‐line FAAS determination. The MWNTs packed microcolumn exhibited fairly fast kinetics for the adsorption of cadmium and copper, permitting the use of high sample flow rates up to at least 7.8 mL min?1 for the FI on‐line microcolumn preconcentration system without loss of the retention efficiency. With a preconcentration time of 60 sec at a sample loading flow rate of 4.3 mL min?1, the enhancement factor was 24 for cadmium and 25 for copper at a sample throughput of 45 h?1. The detection limits (3σ) were 0.30 and 0.11 µg L?1 for Cd and Cu, respectively. The precision (RSD) for 11 replicate measurements was 2.1% at the 10‐µg L?1 Cd level and 2.4% at the 10‐µg L?1 Cu level. The developed method was successfully applied to the determination of trace Cd and Cu in a variety of environmental and biological samples.  相似文献   

12.
The aim of this study was to develop an analytical methodology for the determination of the herbicide pendimethalin in river waters in the towns of Turvo and Meleiro in the southern region of Santa Catarina State, Brazil. The method, based on solid phase microextraction (SPME) followed by separation and detection by gas chromatography (GC) and electron capture detection (ECD), respectively, was optimised and validated. The limits of detection (LOD) and quantification (LOQ) of 0.02 and 0.06?µg?L?1, respectively, and recovery values in the range of 86.2 (±11.5)% to 103.4 (±9.5)% were obtained. It was verified that 53 river water samples showed contamination by pendimethalin at levels that ranged from 0.06 to 0.38?µg?L?1.  相似文献   

13.
《Analytical letters》2012,45(1-3):271-283
A flow injection system is proposed for catalytic kinetic spectrophotometric determination of trace iron(II + III). The involved reaction is based on the catalytic effect of iron(III) on oxidation reaction of xylenol orange by potassium bromate to form a blue-violet complex. Iron(II) is also determined, being oxidized to iron(III) by potassium bromate. The calibration graph is linear in the range of 0.02–10.0 µg l?1 and 10.0–1100 µg l?1. The relative standard deviation is 1.5% for 4.0 µg l?1 iron(III) and 2.3% for 60.0µg l?1 iron(III) (n = 11). The presented system was applied successfully to the determination of iron in natural waters.  相似文献   

14.
A novel inhibition-based glucose oxidase (GOx) biosensor for environmental chromium(VI) detection is described. An electropolymerized aniline membrane has been prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx is cross-linked by glutaraldehyde. The mechanism of the redox reaction on the electrode and the performance of the sensor are studied. The sensor's response to glucose decreases when it is inhibited by chromium(VI), with a lower detection limit of 0.49?µg?L?1, and the linear response range is divided into two parts, one of which is 0.49–95.73?µg?L?1 and the other is 95.73?µg?1 to8.05?mg?L?1. The enzyme membrane is shown to be completely reactivated after inhibition, retaining 90% activity over more than forty days. Interference to chromium(VI) determination from lead(II), copper(II), cadmium(II), chromium(III), cobalt(II), tin(II) and nickel(II) is found to be minimal, while high concentrations of mercury(II) and silver(I) may interfere with the determination of trace chromium(VI). The sensor has been used for chromium(VI) determination in soil samples with good results.  相似文献   

15.
A dynamic ultrasound-assisted extraction procedure utilizing diluted nitric acid was developed for the determination of copper, iron, manganese and zinc in human hair taken from workers in permanent contact with a polluted environment. The extraction unit of the dynamic ultrasound-assisted extraction system contains a minicolumn into which a specified amount of hair (5–50 mg) is placed. Once inserted into the continuous manifold, trace metals were extracted at 3 mL min−1 with 3 mol L−1 nitric acid under the action of ultrasound for 2 min for zinc and 3 min for copper, iron and manganese determination, and using an ultrasonic water-bath temperature of 70 °C for zinc and 80 °C for copper, iron and manganese determination. The system permits the direct analysis of hair and yields concentrations with relative standard deviations of <3% (n = 11). The applicability of the procedure was verified by analysing human hair samples from workers exposed to welding fumes, and its accuracy was assessed through comparison with a conventional sample dissolution procedure and the use of a certified reference material (BCR 397, human hair).  相似文献   

16.
Mercury-based screen-printed electrodes (SPE) combined with square-wave anodic stripping voltammetry (SWASV) techniques for the analysis of copper, cadmium, lead, and zinc in different water samples have been applied. The detection system has been implemented in a flow cell and different experimental conditions have been tested in view of its application for in-situ monitoring. In particular, an acetate buffer together with a low chloride concentration (0.025?M NaCl) provided best performance and reproducible results. Additionally, the flow system was validated for the first time in terms of limits of detection, linearity, repeatability and recovery. Limits of detection of 2.8?µg?L?1, 4.1?µg?L?1, and 7.5?µg?L?1 for cadmium, lead and copper respectively and repeatabilities lower than 10% (as RSD) were found. Good recoveries have been obtained for the three cations and in particular for copper, even in the presence of zinc. Finally, the method has shown its efficiency for the rapid screening of lead, cadmium and copper contained in both natural waters and wastewater samples.  相似文献   

17.
We describe the analytical performance of a hybrid material composed of SiO2, Al2O3 and TiO2. It was prepared by a sol–gel process and can act as an adsorbent in the continuous-flow enrichment of copper. A minicolumn was packed with the material, copper ions are adsorbed at pH 9.13, then eluted with 1.0?mol?L?1 nitric acid, and determined by FAAS. The material was characterized by infrared spectroscopy, scanning electron and energy dispersive spectroscopy, energy dispersive X-ray fluorescence analysis, powder X-ray diffraction, and specific surface area analysis. No significant interference was observed for most ions in up to copper/interferent ratios of 1:100 and of 1:500 in case of Ca(II), Ba(II), and Mg(II). The breakthrough capacity is 1.4?mg?g?1 under dynamic conditions. The limits of detection and of quantification are 0.50 and 1.4?μg?L?1, respectively, and the calibration plot is linear in the range from 5.0 to 245.0?μg?L?1 (r?=?0.999). The relative standard deviation is 3.20 (for n?=?7 and at a Cu(II) concentration of 10?μg?L?1). The method was applied to the determination of trace copper ions in water, vegetable and alcohol fuel samples.
Figure
We describe the analytical performance of the hybrid material composed of SiO2, Al2O3 and TiO2. It was prepared by a sol–gel process and can act as an adsorbent in the continuous-flow enrichment of copper. The method was applied to the determination of trace copper ions in water, vegetable and alcohol fuel samples.  相似文献   

18.
A new chelating sorbent has been developed using Amberlite XAD-2 resin anchored with pyrocatechol through –N=C– group. This sorbent, characterised by elemental analysis and infrared (IR) spectra, was used as packing for the minicolumn in an on-line system preconcentration system for cadmium, cobalt, copper and nickel determination. Metal ions were sorbed in the minicolumn, from which it could be eluted directly to the nebulizer–burner system of the flame atomic absorption spectrometer (FAAS). Elution of all metals from minicolumn can be made with 0.50 mol L 1 HCl or HNO3. The enrichment factors obtained were 16 (Cd), 24 (Co), 15 (Cu) and 19 (Ni), for 60 s preconcentration time, and 39 (Cd), 69 (Co), 36 (Cu) and 41 (Ni), if used 180 s preconcentration time. Under the optimum conditions, the proposed procedure allowed the determination of cadmium, cobalt, copper and nickel with detection limits of 0.31, 0.32, 0.39 and 1.64 μg L 1, respectively, when used preconcentration periods of 180 s. The accuracy of the developed procedure was sufficient and evaluated by the analysis of the certified reference materials NIST 1515 apple leaves and NIST 1570a spinach leaves. The method was applied to the analysis of food samples (spinach, black tea and rice flour).  相似文献   

19.
A new and simple column-solid-phase extraction method has been developed to separate and preconcentrate trace cobalt in water and soil prior to its determination by flame atomic absorption spectrometry (FAAS). Different factors such as pH of sample solution, sample volume, amount of resin, flow rate of aqueous solution, volume and concentration of eluent, and matrix effects for preconcentration were optimized. Under optimized experimentally established conditions, an analytical detection limit of 0.44?µg?L?1, precision (RSD) of 1.9%, enrichment factor of 200, and capacity of resin of 82?mg?g?1 were obtained. The method was applied for cobalt determination by FAAS in tap water, natural drinking water, soil, and roadside dust samples. The accuracy of the method is confirmed by analysing standard reference material (Montana Soil, SRM 2711).  相似文献   

20.
The simultaneous determination of Zn and Cu by anodic stripping voltammetry (ASV) is prone to errors due to the formation of Cu‐Zn intermetallic compounds. The main aim of this work was to study the possibility of simultaneous determination of Zn and Cu, together with Hg and Pb, using a mercury‐free solid gold microwire electrode. The multi‐element detection was carried out by differential pulse anodic stripping voltammetry (DPASV), in a chloride medium (0.5 M NaCl) under moderate acid conditions (HCl 1.0 mM) in the presence of oxygen, where the gold microwire electrode was used as stationary or vibrating working electrode during the deposition step. Under these conditions, no formation of Cu‐Zn intermetallic compounds were found for concentrations usually determined in surface waters. In addition, quantification of Zn and Cu, together with Hg and Pb, can be performed in a wide range of concentrations (about two orders of magnitude) using the same sample, in a very short period of time. The detection limits for Cu, Hg, Pb and Zn, using a vibrating electrode and 30 s of deposition time, were 0.2 µg L?1 for Hg, 0.3 µg L?1 for Pb and 0.4 µg L?1 for Zn and Cu, respectively. The proposed DPASV methods were successfully applied to the determination of Cu, Hg, Pb, and Zn in a certified reference fresh water, river, tap and coastal sea waters. These results proved the applicability and versatility of the proposed methods for the analysis of different water matrices and showed that a gold microwire electrode is a suitable choice to determine simultaneously Zn and Cu.  相似文献   