首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
An efficient sample extraction and cleanup method was developed for determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) in eggs. The procedure included solvent extraction of HMX from eggs followed by cleanup using florisil and styrene-divinylbenzene (SDB) cartridges. Homogenized egg aliquots were thoroughly mixed with 10 mL acetonitrile and extracted with ultrasonication for 1 h. Each sample was centrifuged and all liquid was collected for cleanup. After concentration by N2 evaporation, each extract was cleaned by florisil and SDB cartridges to remove endogenous interfering compounds. Finally, each extract was filtered through a 0.2 μm PTFE membrane and stored for liquid chromatographic-mass spectrometric (LC-MS) analysis. Chromatographic separation was achieved on a reverse phase (RP) C18 column, with a mobile phase containing 60% methanol + 40% 1.0 mM acetic acid aqueous solution. Acetic acid was employed as mobile phase additive to form negatively charged adduct ions [M + CH3COO], and m/z = 355 was quantified by selective ion monitoring (SIM). Overall recoveries from eggs containing 10, 50, 250 and 1000 ng/g of HMX were 84.0%, 88.0%, 90.6% and 87.4%. A method detection limit (MDL) of 0.15 ng/g was achieved.  相似文献   

2.
A quantitative liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed for the analysis of the explosive, octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). In negative ionization mode, HMX forms an acetate adduct ion [M + CH(3)COO](-), m/z 355, in the presence of a small amount of acetic acid in the mobile phase. The ESI collision-induced dissociation (CID) spectrum of m/z 355 was acquired and the transitions m/z 355 --> 147 and m/z 355 --> 174 were chosen for the determination of HMX in samples. Using this quantification technique, the method detection limit was 1.57 microg/L and good linearity was achieved in the range 5-500 microg/L. This method will help to unambiguously analyze environmentally relevant concentrations of HMX.  相似文献   

3.
A new method is proposed for the chemiluminescent determination of the pesticide 3-indolyl acetic acid by means of an flow injection analysis system. The chemiluminescence emission is obtained by oxidation of the analyte with Ce (IV) in nitric acid and presence of β-cyclodextrine.The continuous-flow method allows the determination of 159 samples h−1 of 3-indolyl acetic acid in an interval of concentrations over the range 0.5-15.0 mg l−1. The limit of detection was 0.1 μg l−1 and the R.S.D. (n, 17) at 2.0 mg l−1 of the pesticide level was 2.7%. The method was applied to water samples.  相似文献   

4.
Haghighi B  Kurd SF 《Talanta》2004,64(3):688-694
A flow injection method on the basis of gas phase molecular absorption is described for the sequential determination of ammonium and nitrate. Two hundred microliters of sample solution is injected into the flow line. For ammonium determination, the sample zone is directed to a line in which reacts with NaOH (13 M) and produces ammonia. But for nitrate determination, the sample zone is passed through the on-line copperized zinc (Zn/Cu) reduction column and produces ammonium ion and in the follows ammonia. The produced ammonia in both cases is purged into the stream of N2 carrier gas. The gaseous phase is separated from the liquid phase using a gas-liquid separator and then is swept into a flow through cell, which has been positioned in the cell compartment of an UV-Vis spectrophotometer. The absorbance of the gaseous phase is measured at 194 nm. Under selected conditions for sequential analysis of ammonium and nitrate, linear relations were found between the peak heights of absorption signals and concentrations of ammonium (10-650 μg ml−1) and nitrate (20-800 μg ml−1). The limit of detections for ammonium and nitrate analysis were 8 and 10 μg ml−1, respectively. The relative standard deviations of repeated measurements of 50 μg ml−1 of ammonium and nitrate were 2.0, 2.9%, respectively. Maximum sampling rate was about 40 samples/h. The method was applied to the determination of ammonium in pharmaceutical products and the sequential determination of ammonium and nitrate in spiked water samples.  相似文献   

5.
An analytical method based on the cloud point extraction combined with high performance liquid chromatography is used for the extraction, separation and determination of four explosives; octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT) and pentaerythritol tetranitrate (PETN). These compounds are extracted by using of Triton X-114 and cetyl-trimethyl ammonium bromide (CTAB). After extraction, the samples were analyzed using a HPLC-UV system. The parameters affecting extraction efficiency (such as Triton X-114 and CTAB concentrations, amount of Na2SO4, temperature, incubation and centrifuge times) were evaluated and optimized. Under the optimum conditions, the preconcentration factor was 40 and the improvement factors of 34, 29, 61 and 42 with detection limits of 0.09, 0.14, 0.08 and 0.40 (μg L−1) were obtained for HMX, RDX, TNT and PETN, respectively. The proposed method was successfully applied to the determination of these compounds in water samples and showed recovery percentages of 97-102% with RSD values of 2.13-4.92%.  相似文献   

6.
This work reports the development of a selective, sensitive and rapid spectrofluorimetric method for the determination of reduced glutathione (GSH) in the presence of relatively high levels of cysteine (Cys) in clinical and biological samples using 1,3,5,7-tetramethyl-8-phenyl-(2-maleimide)-difluoroboradiaza-s-indacene (TMPAB-o-M). The fluorescence from TMPAB-o-M is strongly quenched by its maleimide moiety, but after reaction with thiol, the fluorescence is restored with a 350-fold intensity increase (fluorescence quantum yield from 0.002 to 0.73). In H3Cit-Na2HPO4 buffer (pH 7.40), the derivatization is completed in just 5 min under 37 °C. The linear range is 0.005-0.2 μmol L−1, with detection limit of 1.1 × 10−10 mol L−1 (signal-to-noise ratio = 3). Almost all amino acids, including Cys, impose no interference even if present at relatively high concentrations (amino acids:GSH = 100:1, Cys:GSH = 1:1, molar ratio, CGSH = 3 × 10−7 mol L−1). The sample can be used directly without further treatment after the protein is removed. The developed method is precise with a relative standard deviation (R.S.D.) lower than 5.0% (n = 6) and has been applied to the determination of GSH in human blood and pig’s liver with recoveries between 94.4 and 105.6%.  相似文献   

7.
In the present study, dissociative electron attachment (DEA) measurements with gas phase HMX, octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, C4H8N8O8, have been performed by means of a crossed electron-molecular beam experiment. The most intense signals are observed at 46 and 176 u and assigned to NO2 ? and C3H6N5O4 ?, respectively. Anion efficiency curves for 15 negatively charged fragments have been measured in the electron energy region from about 0–20 eV with an energy resolution of ~0.7 eV. Product anions are observed mainly in the low energy region, near 0 eV, arising from surprisingly complex reactions associated with multiple bond cleavages and structural and electronic rearrangement. The remarkable instability of HMX towards electron attachment with virtually zero kinetic energy reflects the highly explosive nature of this compound. Substantially different intensity ratios of resonances for common fragment anions allow distinguishing the nitroamines HMX and royal demolition explosive molecule (RDX) in negative ion mass spectrometry based on free electron capture.   相似文献   

8.
A specific and highly sensitive liquid chromatography-electrospray mass spectrometry (LC-ESI-MS) method for the direct determination of bupropion (BUP) and its main metabolite hydroxybupropion (HBUP) in rat plasma and brain microdialysate has been developed and validated. The analysis was performed on a Bonus RP C18 (100 mm × 2.1 mm i.d., 3.5 μm particles) column using gradient elution with the mobile phase consisting of acetonitrile and ammonium formate buffer (10 mM, pH 4). Plasma samples were analyzed after a simple, one-step protein precipitation clean-up with trichloroacetic acid (TCA), however clean-up for microdialysis samples was not necessary, enabling direct injection of the samples into the LC-ESI-MS system. Signals of the compounds were monitored under the multiple reaction monitoring (MRM) mode of the LC-ESI-MS (ion trap) for quantification. The precursor to product ion transitions of m/z 240-184 and m/z 256-238 were used to measure BUP and HBUP, respectively. The method was validated in both plasma and microdialysate samples, and the obtained lower limit of quantification (LLOQ) was 1.5 ng mL−1 for BUP and HBUP in both matrices. The intra- and inter-day assay variability was less than 15% for both analytes. This LC-ESI-MS method provided simple sampling, rapid clean-up and short analysis time (<9 min), applicable to the routine therapeutic monitoring and pharmacokinetic studies of BUP and HBUP.  相似文献   

9.
A rapid method has been developed for the determination of lead extracted by acetic acid from glazed ceramic surfaces by flow injection analysis without any pretreatment. An aliquot of 4% acetic acid solution, which has been kept in a teacup for 24 h in the dark, is injected into a carrier solution (1 M nitric acid) and passed through a Pb-Spec resin column. After washing the column with an ammonium nitrate solution, the lead adsorbed on the column is eluted with an ammonium oxalate solution and then merged with a 4-(2-pyridylazo)resorcinol (PAR) solution, followed by measurement of the absorbance of the lead-PAR complex at 530 nm. The detection limit, concentration giving a signal equal to three times the standard deviation of the blank signal, is 8 ng ml−1. The relative standard deviation of measurements at the 0.8 μg ml−1 level is 0.35% (n = 5). The sample throughput is 12 per hour.  相似文献   

10.
Huang KJ  Wang H  Guo YH  Fan RL  Zhang HS 《Talanta》2006,69(1):73-78
A new fluorescent probe 1,3,5,7-tetramethyl-2,6-dicarbethoxy-8-(3′,4′-diaminophenyl)-difluoroboradiaza-s-indacene (TMDCDABODIPY) has been developed to detect nitrite in meat products and vegetables. The fluorescence of TMDCDABODIPY is very weak, but when it reacts with nitrite, a strong fluorescent triazole forms in aqueous medium at room temperature, which offers the advantage of specificity and sensitivity for the determination of nitrite. The fluorescence intensity was linear over a nitrite concentration of 9-300 nmol l−1 with a detection limit of 0.21 nmol l−1 (S/N = 3). The proposed method has been used for the determination of trace nitrite in food products with the recoveries of 94.62-105.48%.  相似文献   

11.
High-performance liquid chromatography (HPLC) and fluorescence derivatization were applied for a nanogram-level N-nitrosodimethylamine (NDMA) analysis of water samples. For the analysis of N-nitrosodimethylamine, samples were first denitrosated by a mixed solution of hydrobromic acid and acetic acid to produce dimethylamine, which was derivatized with dansyl chloride for HPLC fluorescence detection. Fluorescence detection was optimized with excitation and emission wavelengths of 340 and 530 nm, respectively. pH adjustment after denitrosation was necessary to maximize fluorescence intensity with pHs in the range of 9-12. A dansyl chloride concentration of 500 mg l−1 was found to be optimal for measuring a fluorescence signal. An instrumental detection limit of 0.1 ng of NDMA was possible with fluorescence derivatization. The NDMA in water samples was extracted by continuous solid-phase extraction using Ambersorb 572. Although the determination of NDMA was variable at lower concentrations (less than 200 ng l−1), it was observed that the NDMA detection limit with this method could be lowered to a concentration of 10 ng l−1. Another benefit of this method can be found in its selectivity for NDMA. Unlike gas chromatographic (GC) methods, this method generates a distinct peak for NDMA without interference even in the complex matrix of wastewater effluents. The HPLC with fluorescence derivatization method may be applicable for determining NDMA in water and wastewater samples for various research purposes and for screening environmental samples.  相似文献   

12.
A simple method for the rapid and simultaneous analysis of dichlorvos (DDVP), malathion, carbaryl, and 2,4-dichlorophenoxy acetic acid (2,4-D) in citrus fruit, which uses flow-injection ion spray ionization tandem mass spectrometry, has been developed for the first time. The method involves the combined use of stable isotopically labeled internal standards (DDVP-d6, malathion-d10, carbaryl-d7, and 2,4-D-d5) and a multiple reaction monitoring technique. The average recoveries for the pesticides at the same concentrations as their tolerance levels (DDVP: 0.1-0.2 μg g−1; malathion: 0.5-4.0 μg g−1; carbaryl: 1.0 μg g−1; 2,4-D: 1.0-2.0 μg g−1) ranged from 90 to 119% with the relative standard deviation (R.S.D.) ranging from 1.0 to 13.1% (n = 5). Analysis time, including sample preparation and determination, was only 15 min. The present method is effective for screening DDVP, malathion, carbaryl, and 2,4-D in citrus fruit.  相似文献   

13.
14.
Coelho LH  Gutz IG 《Talanta》2006,69(1):204-209
A chemometric method for analysis of conductometric titration data was introduced to extend its applicability to lower concentrations and more complex acid-base systems. Auxiliary pH measurements were made during the titration to assist the calculation of the distribution of protonable species on base of known or guessed equilibrium constants. Conductivity values of each ionized or ionizable species possibly present in the sample were introduced in a general equation where the only unknown parameters were the total concentrations of (conjugated) bases and of strong electrolytes not involved in acid-base equilibria. All these concentrations were adjusted by a multiparametric nonlinear regression (NLR) method, based on the Levenberg-Marquardt algorithm. This first conductometric titration method with NLR analysis (CT-NLR) was successfully applied to simulated conductometric titration data and to synthetic samples with multiple components at concentrations as low as those found in rainwater (∼10 μmol L−1). It was possible to resolve and quantify mixtures containing a strong acid, formic acid, acetic acid, ammonium ion, bicarbonate and inert electrolyte with accuracy of 5% or better.  相似文献   

15.
In this work, it was developed a method for the determination of nitrite and nitrate in groundwater by high-resolution continuum source electrothermal molecular absorption spectrometry of NO produced by thermal decomposition of nitrate in a graphite furnace. The NO line at 215.360 nm was used for all analytical measurements and the signal obtained by integrated absorbance of three pixels. A volume of 20 μL of standard solution or groundwater sample was injected into graphite furnace and 5 μL of a 1% (m/v) Ca solution was co-injected as chemical modifier. The pyrolisis and vaporization temperatures established were of 150 and 1300 °C, respectively. Under these conditions, it was observed a difference of thermal stability among the two nitrogen species in the presence of hydrochloric acid co-injected. While that the nitrite signal was totally suppressed, nitrate signal remained nearly stable. This way, nitrogen can be quantified only as nitrate. The addition of hydrogen peroxide provided the oxidation of nitrite to nitrate, which allowed the total quantification of the species and nitrite obtained by difference. A volume of 5 μL of 0.3% (v/v) hydrochloric acid was co-injected for the elimination of nitrite, whereas that hydrogen peroxide in the concentration of 0.75% (v/v) was added to samples or standards for the oxidation of nitrite to nitrate. Analytical curve was established using standard solution of nitrate. The method described has limits of detection and quantification of 0.10 and 0.33 μg mL−1 of nitrogen, respectively. The precision, estimated as relative standard deviation (RSD), was of 7.5 and 3.8% (n = 10) for groundwater samples containing nitrate–N concentrations of 1.9 and 15.2 μg mL−1, respectively. The proposed method was applied to the analysis of 10 groundwater samples and the results were compared with those obtained by ion chromatography method. In all samples analyzed, the concentration of nitrite–N was always below of the limit of quantification of both the methods. The concentrations of nitrate–N varied from 0.58 to 15.5 μg mL−1. No significant difference it was observed between the results obtained by both methods for nitrate–N, at the 95% confidence level.  相似文献   

16.
Elimination of interfering substances in urine by solid phase extraction (SPE) prior to analysis resulted in 10-fold improvement in the sensitivity of atrazine mercapturate (AM) enzyme-linked immunosorbent assay (ELISA) compared to previous reports. Of the two tested SPE systems, Oasis® HLB and MCX, the mixed-mode MCX gave good recoveries (82%) of AM in spiked samples measured by ELISA, whereas the reverse-phase HLB phase was not compatible with the immunochemical method. At relatively high concentrations of urinary AM (>20 ng mL−1), sample dilution was effective enough for the elimination of interfering substances. The new liquid chromatography-mass spectrometry (LC-MS) method developed for AM utilizes online-SPE with Oasis® HLB, column switching and a stable-isotope internal standard. The limit of quantification (0.05 ng mL−1) indicates improved sensitivity compared with most previously published LC-MS methods for AM. Validation of all three methods, LC-MS, ELISA + SPE and ELISA + dilution with spiked urine samples showed good correlation between the known and measured concentrations with R2 values of 0.996, 0.957 and 0.961, respectively. When a set (n = 70 plus 12 blind duplicates) of urine samples from farmers exposed to atrazine was analyzed, there was a good agreement (R2 = 0.917) between the log normalized data obtained by ELISA + SPE and LC-MS. High correlation among the data obtained by the two tested methods and the LC-MS method by the Center of Disease Control and Prevention (CDC), together with low variability among the blind duplicates, suggests that both methods reported here would be suitable for the analysis of urinary AM as a biomarker for human exposure of atrazine.  相似文献   

17.
Olivier Vigneau 《Talanta》2009,77(5):1609-1058
The introduction of chloroform into the nebulising gas of a LC/MS electrospray interface (ESI), in a perfectly controlled way, leads to the formation of intense adducts ([M+Cl]) when a mobile phase containing HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazacyclooctane or octogen) and RDX (1,3,5-trintro-1,3,5-triazacyclohexane or hexogen) is eluted. This LC/MS method allows the direct analysis of aqueous samples containing HMX and RDX at the pictogram level without a concentration step. The method is used to determine HMX and RDX concentrations in ground water samples from a military site.  相似文献   

18.
A BODIPY-based fluorescent derivatization reagent with a hydrazine moiety, 1,3,5,7-tetramethyl-8-aminozide-difluoroboradiaza-s-indacene (BODIPY-aminozide), has been designed for aldehyde labeling. An increased fluorescence quantum yield was observed from 0.38 to 0.94 in acetonitrile when it reacted with aldehydes. Twelve aliphatic aldehydes from formaldehyde to lauraldehyde were used to evaluate the analytical potential of this reagent by high performance liquid chromatography (HPLC) on C18 column with fluorescence detection. The derivatization reaction of BODIPY-aminozide with aldehydes proceeded at 60 °C for 30 min to form stable corresponding BODIPY hydrazone derivatives in the presence of phosphoric acid as a catalyst. The maximum excitation (495 nm) and emission (505 nm) wavelengths were almost the same for all the aldehyde derivatives. A baseline separation of all the 12 aliphatic aldehydes (except formaldehyde and acetaldehyde) is achieved in 20 min with acetonitrile–tetrahydrofuran (THF)–water as mobile phase. The detection limits were obtained in the range from 0.43 to 0.69 nM (signal-to-noise = 3), which are better than or comparable with those obtained by the existing methods based on aldehyde labeling. This reagent has been applied to the precolumn derivatization followed with HPLC determination of trace aliphatic aldehydes in human serum samples without complex pretreatment or enrichment method.  相似文献   

19.
A previously elaborated capillary electrophoresis (CE) method used for the determination of glyphosate and aminomethylphosphonic acid (AMPA) was slightly modified in order to improve the sensitivity. However, detection limits attained (5 μg mL−1 for glyphosate and 4 μg mL−1 for AMPA) were still not satisfactory for analytical purposes, thus the addition of a preconcentration step before the CE analysis was proposed. AMBERLITE®IRA-900, a strong anion-exchange resin, was used to preconcentrate both analytes in environmental aqueous samples. The experimental conditions optimised in a previous work were readapted, by decreasing the eluent concentration due to CE limitations. Satisfactory results were attained when spiked ultrapure water was applied, with recoveries from 84 to 87% for glyphosate (R.S.D. < 6%) and from 85 to 98% for AMPA (R.S.D. < 5%). Enrichment factors up to 65 were achieved with this system, allowing the determination of 85 ng mL−1 of glyphosate and 60 ng mL−1 of AMPA. The extraction efficiency varied when four different natural water samples of varying conductivity were applied. Especially the strong dependence on ion concentration in samples on AMPA recovery was found. For glyphosate, good recoveries (86-99%) were obtained for samples of low and medium conductivity (0-800 μS). The effect of sample salt content on extraction efficiency was studied and a linear relationship could be established for AMPA (r2 = 0.996). An important improvement on recoveries was observed when lower volumes of sample were treated.A HPLC method with UV-vis detection and pre-column derivatisation with p-toluensulphonyl chloride was compared to the CE method. No significant differences in results were found when t- and F-statistical tests were applied.  相似文献   

20.
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5 > 166.1 for itopride and m/z 342.3 > 111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2 = 0.9999) over the studied range (0.5-1000 ng mL−1) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号