首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Liang AH  Zhou SM  Jiang ZL 《Talanta》2006,70(2):444-448
Based on resonance scattering (RS) effect of rhodamine dye association particles, a new resonance scattering method for the determination of hydroxyl free radical from Fenton reaction was developed. In HCl-NaAc buffer solution, the OH of Fenton reaction oxidized the excess I to I3. The I3 combined, respectively, with rhodamine B (RhB), butyl rhodamine B (b-RhB), rhodamine 6G (RhG) and rhodamine S (RhS) to form association particles that exhibit stronger resonance scattering effect at 420 nm and 610 nm. However, the RS peak at about 610 nm was interfered with its synchronous fluorescence peak at 580 nm for RhB, 580 nm for b-RhB, 560 nm for RhG and 560 nm for RhS, respectively. The concentration of H2O2 in the range of 0.648-21.6 μmol/L, 0.423-13.0 μmol/L, 0.216-13.0 μmol/L and 0.092-13.0 μmol/L was linear to its resonance scattering intensity at 420 nm. Its detection limit was 0.15 μmol/L, 0.10 μmol/L, 0.092 μmol/L and 0.044 μmol/L, H2O2, respectively. This RhS RS method was applied to selection of the antioxidant, with satisfactory results.  相似文献   

2.
CdS quantum dots (QDs) modified with l-cysteine has been prepared by one step. They are water-soluble and biocompatible. To improve CdS QDs stability and interaction between silver ion and functionalized CdS QDs in aqueous solution, some amounts of fresh l-cysteine were added to functionalized CdS solution. Based on the characteristic fluorescence enhancement of CdS QDs at 545 nm by silver ions in the presence of some amounts of fresh l-cysteine, simultaneously, a gradual red shift of fluorescence emission bands of CdS QDs from 545 to 558 nm was observed. A simple, rapid, sensitive and specific detection method for silver ion was proposed. Under optimum conditions, the fluorescence intensity of CdS QDs is linearly proportional to silver concentration from 2.0 × 10−8 to 1.0 × 10−6 mol/L with a detection limit of 5.0 × 10−9 mol/L. In comparison with single organic fluorophores, functionalized CdS quantum dots are brighter, more stable against photobleaching, and don’t suffer from blinking. Furthermore, owing to the fluorescence enhancement effect of CdS QDs by silver ion, the proposed method showed lower detection blank and higher sensitivity. Possible fluorescence enhancement mechanism was also studied.  相似文献   

3.
Response surface methodology (RSM) was applied to the optimization of on-line solid-phase extraction (SPE) parameters, and an automated system of on-line SPE coupled with high-performance liquid chromatography (HPLC) with fluorescence detection was developed for the determination of puerarin and daidzein in human serum. The human serum sample of 50 μL was injected into a conditioned C18 SPE cartridge, and the matrix was washed out with acetonitrile-KH2PO4-triethylamine buffer (0.01 M, pH 7.4) (3:97, v/v) for 3 min at a flow rate of 0.25 mL/min. Then the target analytes were eluted and transferred to the analytical column. A chromatographic gradient elution was programmed with the mobile phase consisting of acetonitrile and KH2PO4-triethylamine buffer, and the analytes were determined with a fluorescence detector at excitation wavelength of 350 nm and emission wavelength of 472 nm, respectively. The proposed method presented good linear relations (0.85-170 μg/mL for puerarin and 0.2-40 μg/mL for daidzein), satisfactory precision (RSD < 8%), and accredited recovery (92.5-107.8%).  相似文献   

4.
Zuo Y  Wang C  Van T 《Talanta》2006,70(2):281-285
A simple, fast, sensitive and accurate reversed-phase ion-pair HPLC method for simultaneous determination of nitrite and nitrate in atmospheric liquids and lake waters has been developed. Separations were accomplished in less than 10 min using a reversed-phase C18 column (150 mm × 2.00 mm i.d., 5 μm particle size) with a mobile phase containing 83% 3.0 mM ion-interaction reagent tetrabutylammonium hydroxide (TBA-OH) and 2.0 mM sodium phosphate buffer at pH 3.9 and 17% acetonitrile (flow rate, 0.4 mL/min). UV light absorption responses at 205 nm were linear over a wide concentration range from 100 μg/mL to the detection limits of 10 μg/L for nitrite and 5 μg/L nitrate. Quantitation was carried out by the peak area method. The relative standard deviation for the analysis of nitrite and nitrate was less than 3.0%. This method was applied for the simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples collected in southeast Massachusetts. Nitrate was found being present at 4.79-5.99 μg/mL in dew, 1.20-2.63 μg/mL in rain, 0.32-0.60 μg/mL in snow and 0.12-0.23 μg/mL in lake water. Nitrite was only a minor species in dew (0.62-0.83 μg/mL), rain (<0.005-0.14 μg/mL), snow (0.021-0.032 μg/mL) and lake water (0.12-0.16 μg/mL). High levels of nitrite and nitrate observed in dew water droplets may constitute an important source of hydroxyl radicals in the sunny early morning.  相似文献   

5.
Capillary electrophoresis (CE) coupled with fiber-optic light-emitting diode-induced fluorescence detection has been developed for the separation of tyrosine (Tyr) enantiomers. R(−)-4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl)-2,1,3-benzoxadiazole was used as a chiral fluorescence tagged reagent for derivatization of Tyr. The effect of pH, running buffer concentration and applied voltage on enantioselectivity has been investigated. The optimum CE conditions are 15 mmol/L borate running buffer (pH 10.5) and 14-kV applied voltage. Good reproducibility was obtained with coefficient of variation (n = 7) of migration time and peak area less than 0.2 and 2.0%, respectively. The limits of detection of d- and l-Tyr derivatives were 2.9 and 2.2 μmol/L (S/N = 3), respectively. The proposed method has been successfully applied to the determination of Tyr in a commercial amino acid oral solution.  相似文献   

6.
A simple and efficient dual preconcentration method of on-column liquid–liquid–liquid microextraction (LLLME) coupled with base stacking was developed for capillary zone electrophoresis (CZE) in this paper. Four N-methyl carbamates were used as target compounds to evaluate the enrichment means. The carbamates in sample solutions (donor phase) were extracted into a dodecanol phase immobilized on a porous hollow fiber, hydrolyzed and back extracted into 0.20 μL running buffer (acceptor phase) of 30 mmol/L methylamine hydrochloride (pH 11.6) containing 0.5 mmol/L tetradecyltrimethylammonium bromide inside the hollow fiber, stacked further with 0.5 mol/L NaOH injected at −10 kV for 60 s, and separated by CZE. Analytical parameters affecting the LLLME, base stacking and CZE were investigated, including sample solution volume, pH and temperature, extraction time, stirring rate, buffer component, buffer pH, NaOH concentration, stacking time, etc. The enrichment factors of the carbamates were higher than 1100. The relative standard deviation (RSD) of peak height and limits of detection (LODs) were 4.5–5.5% (n = 6) and 2–4 ng/mL (S/N = 3) for standard solutions, respectively. The proposed method was applied to the analysis of vegetable and fruit samples with the RSD less than 6.0% (n = 3) and LODs of 6–10 ng/g (S/N = 3). The calibration solutions were prepared by diluting the stock solutions with blank sample solutions, and the calibration concentrations ranged from 0.012 to 1.0 μg/mL (r > 0.9951). The analytical results demonstrated that the LLLME coupled with base stacking was a simple, convenient and reliable on-column sample pretreatment method for the analysis of anionic analytes in CZE.  相似文献   

7.
Altered levels of aminothiols in biological fluids are thought to be an important risk indicator for several diseases, and reliable methods for the accurate determination of aminothiols concentrations in plasma are thus required. In this paper ammonium 5-bromo-7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-BF) is proposed as a convenient fluorogenic derivatizating reagent for the determination of aminothiols (cysteine, cysteinylglycine, homocysteine and glutathione) by HPLC with fluorescence detection. The reactions of SBD-BF with aminothiols at room temperature are about three-times faster than those of ammonium 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (the most frequently employed reagent) at 60 °C. The derivatives of SBD-BF with cysteine, cysteinylglycine, homocysteine and glutathione are easily separated by HPLC and their calibration curves show excellent linearity over the range 0.05–20 μmol/L with excellent r2 values for all analytes. SBD-BF reacts with thiols under mild conditions, i.e. at 25 °C over about 30 min, and is proposed as a suitable fluorogenic reagent for thiol derivatization to be introduced in analytical clinical chemistry. The detection limits of Cys, Cys-Gly, Hcy and GSH at a signal-to-noise ratio of 5 were 0.1 μM for Cys, 0.01 μM for Cys-Gly and Hcy, and 0.02 μM for GSH. Furthermore, validation parameters of the proposed method are quite satisfactory. As an application of this method the determination of thiol derivatives in human plasma was carried out on a number of samples.  相似文献   

8.
Yinhuan Li  Weifen Niu 《Talanta》2007,71(3):1124-1129
A flow injection chemiluminescence method was described for the determination of four phenothiazine drugs, namely, chlorpromazine hydrochloride, perphenazine hydrochloride, fluphenazine hydrochloride and thioridazine hydrochloride. Strong Chemiluminescence (CL) signal was produced when above-mentioned drug was injected into the mixed stream of luminol with KMnO4. The linear ranges of the method were 0.0020-1.0 μg/mL chlorpromazine hydrochloride, 0.0040-3.0 μg/mL perphenazine hydrochloride, 0.0020-5.0 μg/mL fluphenazine hydrochloride and 0.0050-1.0 μg/mL thioridazine hydrochloride. The detection limits were 0.4 ng/mL chlorpromazine hydrochloride, 0.7 ng/mL perphenazine hydrochloride, 2 ng/mL fluphenazine hydrochloride and 0.7 ng/mL thioridazine hydrochloride. The proposed method was applied to the determination of chlorpromazine hydrochloride in injections and in mental patient's urine samples and the satisfactory results were achieved. The possible CL reaction mechanism was also discussed briefly.  相似文献   

9.
Chang W  Ono Y  Kumemura M  Korenaga T 《Talanta》2005,67(3):646-650
A microchip-based method was developed for on-line determination of trace sulfur dioxide (SO2) in air. Gaseous SO2, which diffused through the porous glass materials on the microchip, was absorbed into an absorption solution of triethanolamine (TEA) as sulfite ions and reacted with N-(9-acridinyl)maleimide (NAM), which was used as a fluorescent reagent. The fluorescence of NAM-sulfite in micro-fluidic channel was detected. The calibration curve of sulfite ions in the range of 1.5-30 μmol/L (SO2 3-60 ppbv) showed a linear relation R2 = 0.995, and the relative standard deviation (R.S.D.) was 1.9% for 10 μmol/L sulfite ions in five measurements. The entire measurement procedure was achieved by the integrated microchip, and the consumption of reagents was drastically reduced. It was satisfactory to apply this method to determine on-line the SO2 level in the air.  相似文献   

10.
Xiaojia Huang  Dongxing Yuan 《Talanta》2007,72(4):1298-1301
A simplified and rapid determining/identifying method for residual sulfonamides (SAs) in milk by using Ether-type stationary phase, which made in our lab, was presented. The target analytes were extracted by mixing with ethanol-acetic acid (97:3, v/v) followed by centrifugation. The procedure used a Ether-type C8 column, isocratic elution with acetonitrile-water (5:95, v/v), and a photo-diode array detector. The linear range of determination was 50-10,000 μg/L for sulfanilamide and 100-10,000 μg/L for sulfadiazine, sulfamerazine, sulfamethazine. Average recoveries of four SAs (spiked 0.5, 1.0 and 1.5 μg/mL) ranged from 80.1% to 87.6%, with relative standard deviations between 3.4% and 5.8%. The total time and solvent required for the analysis of one sample were <15 min and <1.0 mL of ethanol and 0.6 mL of acetonitrile, respectively. The developed procedure was nearly harmless to the human and environment.  相似文献   

11.
Based on the enhancement of chemiluminescence (CL) of luminol-hydrogen peroxide-gold nanoparticles system by fluoroquinolones (FQs), a novel and rapid CL method is reported for the determination of FQs derivatives. Under the optimum conditions, the CL intensity is proportional to the concentration of FQs derivative in solution. The corresponding linear regression equations are established over the range of 0.08-1.28 μg/mL for norfloxacin, 0.013-1.32 μg/mL for ciprofloxacin, 0.014-1.4 μg/mL for lomefloxacin, 0.029-1.46 μg/mL for fleroxacin, 0.02-1.0 μg/mL for ofloxacin and 0.01-1.44 μg/mL for levofloxacin, respectively. The limits of detection (S/N = 3) are 3.2, 9.5, 7.0, 9.0, 8.0, and 8.0 ng/mL with the relative standard deviation (n = 11) 4.3, 1.5, 1.9, 1.3, 1.6 and 2.1% for norfloxacin, ciprofloxacin, lomefloxacin, fleroxacin, ofloxacin and levofloxacin, respectively. This proposed method has been applied to detect FQs derivatives in human urine successfully.  相似文献   

12.
Abraham Joy 《Talanta》2009,80(1):231-235
Methods for the detection and estimation of diphosgene and triphosgene are described. These compounds are widely used phosgene precursors which produce an intensely colored purple pentamethine oxonol dye when reacted with 1,3-dimethylbarbituric acid (DBA) and pyridine (or a pyridine derivative). Two quantitative methods are described, based on either UV absorbance or fluorescence of the oxonol dye. Detection limits are ∼4 μmol/L by UV and <0.4 μmol/L by fluorescence. The third method is a test strip for the simple and rapid detection and semi-quantitative estimation of diphosgene and triphosgene, using a filter paper embedded with dimethylbarbituric acid and poly(4-vinylpyridine). Addition of a test solution to the paper causes a color change from white to light blue at low concentrations and to pink at higher concentrations of triphosgene. The test strip is useful for quick on-site detection of triphosgene and diphosgene in reaction mixtures. The test is easy to perform and provides clear signal readouts indicative of the presence of phosgene precursors. The utility of this method was demonstrated by the qualitative determination of residual triphosgene during the production of poly(bisphenol-A carbonate).  相似文献   

13.
This work assesses the potential of a new adsorptive material, Amberlyst 36, for the separation and preconcentration of trace manganese(II) from various media. It is based on the sorption of manganese(II) ions onto a column filled with Amberlyst 36 cation exchange resin, followed by the elution with 5 mL of 3 mol/L nitric acid and determination by flame atomic absorption spectrometry (FAAS) without interference of the matrix. Different factors including pH of sample solution, sample volume, amount of resin, flow rate of sample solution, volume and concentration of eluent, and matrix effects for preconcentration were investigated. Good relative standard deviation (3%) and high recovery (>95%) at 100 μg/L and high enrichment factor (200) and low analytical detection limit (0.245 μg/L) were obtained. The adsorption equilibrium was described well by the Langmuir isotherm model with maximum adsorption capacity of 88 mg/g of manganese on the resin. The method was applied for the manganese determination by FAAS in tap water, commercial natural drinking water, commercial treated drinking water and commercial tea bag sample. The accuracy of the method is confirmed by analyzing the certified reference material (tea leaves GBW 07605). The results demonstrated good agreement with the certified values.  相似文献   

14.
Dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography with fluorescence detector was applied for the determination of alkylphenols and their short-chained ethoxylates in water samples. Development of DLLME procedure included optimisation of some important parameters such as kind and volume of extracting and dispersing solvents. Under optimised conditions 50 μL of trichloroethylene in 1.5 mL of acetone were rapidly injected into 5 mL of a water sample. After centrifuging the organic phase containing the analytes was taken for evaporation with a gentle nitrogen purge and reconstituted to 50 μL of acetonitrile. The aliquot of this solution was analysed with the use of HPLC. For octylphenol (OP) and octylphenol ethoxylates (OPEOs) linearity was satisfactory in the range 8–1000 μg L−1 and for nonylphenol (NP) and nonylphenol ethoxylates (NPEOs) linearity was in the range from 50 to about 3000 μg L−1. Limit of quantitation was 0.1 μg L−1 for OP and OPEOs and 0.3 μg L−1 for NP and NPEOs. Satisfactory recoveries between 66 and 79% were obtained for environmental samples. The results showed that DLLME is a simple, rapid and sensitive analytical method for the preconcentration of trace amounts of alkylphenols and their ethoxylates in environmental water samples.  相似文献   

15.
An ion-pairing reversed-phase liquid chromatography–mass spectrometry (IP-RP-LC–MS) was developed for the determination of nucleotides, nucleosides and their transformation products in Cordyceps. Perfluorinated carboxylic acid, namely pentadecafluorooctanoic acid (PDFOA, 0.25 mM), was used as volatile ion-paring agent and a reversed-phase column (Agilent ZORBAX SB-Aq column) was used for the separation of three nucleotides namely uridine-5′-monophosphate (UMP, 0.638–10.200 μg/mL), adenosine-5′-monophosphate (AMP, 0.24–7.80 μg/mL) and guanosine-5′-monophosphate (GMP, 0.42–13.50 μg/mL), seven nucleosides including adenosine (0.55–8.85 μg/mL), guanosine (0.42–6.75 μg/mL), uridine (0.33–10.50 μg/mL), inosine (0.21–6.60 μg/mL), cytidine (0.48–15.30 μg/mL), thymidine (0.20–6.30 μg/mL) and cordycepin (0.09–1.50 μg/mL), as well as six nucleobases, adenine (0.22–6.90 μg/mL), guanine (0.26–4.20 μg/mL), uracil (0.38–12.15 μg/mL), hypoxanthine (0.13–4.20 μg/mL), cytosine (0.39–12.45 μg/mL) and thymine (0.26–8.25 μg/mL) with 5-chlorocytosine arabinoside as the internal standard. The overall LODs and LOQs were between 0.01–0.16 μg/mL and 0.04–0.41 μg/mL for the 16 analytes, respectively. The contents of 16 investigated compounds in natural and cultured Cordyceps were also determined and compared after validation of the developed IP-RP-LC-MS method. The transformations of nucleotides and nucleosides in Cordyceps were evaluated based on the quantification of the investigated compounds in three extracts, including boiling water extraction (BWE), 24 h ambient temperature water immersion (ATWE) and 56 h ATWE extracts. Two transformation pathways including UMP → uridine → uracil and GMP → guanosine → guanine were proposed in both natural Cordyceps sinensis and cultured Cordyceps militaris. The pathway of AMP → adenosine → inosine → hypoxanthine was proposed in natural C. sinensis, while AMP → adenosine → adenine in cultured C. militaris. However, the transformation of nucleotides and nucleosides was not found in commercial cultured C. sinensis.  相似文献   

16.
Zhang M  Zhang Z  Yuan D  Feng S  Liu B 《Talanta》2011,84(2):443-450
An automatic gas-phase molecular absorption spectrometric (GPMAS) system was developed and applied to determine nitrite and total nitrate in water samples. The GPMAS system was coupled with a UV-light emitting diode photodiode (UV-LED-PD) based photometric detector, including a 255 nm UV-LED as the light source, a polyvinyl chloride (PVC) tube of 14 cm as the gas flow cell, and an integrated photodiode amplifier to measure the transmitted light intensity. The UV-LED-PD detector was compact, robust, simple and of low heat production, comparing with detectors used in other GPMAS works. For nitrite measurement, citric acid was used to acidify the sample, and ethanol to catalyze the quantitative formation of NO2. The produced NO2 was purged with air flow into the UV-LED-PD detector, and the gaseous absorbance value was measured. The total nitrate could be determined after being reduced to nitrite with a cadmium column. Limits of detection for nitrite and nitrate were 7 μmol/L and 12 μmol/L, respectively; and linear ranges of 0.021-5 mmol/L for nitrite and 0.036-4 mmol/L for nitrate were obtained. Related standard deviations were 1.81% and 1.08% for nitrite and nitrate, respectively, both at 2 mmol/L. The proposed method has been applied to determine nitrite and total nitrate in some environmental water samples.  相似文献   

17.
We developed a sensitive and useful method for the determination of five fluoroquinolones (FQs), enoxacin, ofloxacin, ciprofloxacin, norfloxacin, and lomefloxacin in environmental waters, using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These compounds were analysed within 7 min by high-performance liquid chromatography (HPLC) using a CAPCELL PAK C8 column and aqueous ammonium formate (pH 3.0, 5 mM)/acetonitrile (85/15, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection. In order to optimize the extraction of FQs, several in-tube SPME parameters were examined. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow-rate of 150 μL/min, using a Carboxen 1010 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r ≥ 0.997) was obtained in the concentration range from 0.1 to 10 ng/mL for all compounds examined. The limits of detection (S/N = 3) of the five FQs ranged from 7 to 29 pg/mL. The in-tube SPME method showed 60-94-fold higher sensitivity than the direct injection method (5 μL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface waters and wastewaters were collected from the area around Asahi River, and ofloxacin was detected in wastewater samples of a sewage treatment plant and other two hospitals at 17.5-186.2 pg/mL. The recoveries of FQs spiked into river water were above 81% for a 0.1 or 0.2 ng/mL spiking concentration, and the relative standard deviations were below 1.9-8.6%.  相似文献   

18.
Oguma K  Suzuki T  Saito K 《Talanta》2011,84(5):1209-1214
A flow injection method has been developed for the determination of uranium in seawater combining the on-line preconcentration with spectrophotometric detection. An aliquot (10 mL) of the seawater sample adjusted to pH 5.5 was injected into the analytical system and uranium was adsorbed on the column packed with styrene-divinylbenzene copolymer resin (Bio-Beads SM-2) modified with dodecylamidoxime which showed high selectivity to uranium. Uranium was then eluted with 0.01 M hydrochloric acid and detected spectrophotometrically after the reaction with Chlorophosphonazo III. Interference from calcium and strontium was masked with cyclohexanediaminetetraacetic acid added to the chromogenic reagent solution. The sample throughput, the detection limit (3σ), and the preconcentration factor were 23 per hour, 0.13 μg/L, and 20, respectively, when the sample injection volume was kept at 10 mL. The precision at the 2 μg/L level was less than 4% (RSD). The proposed method was applied to the determination of uranium in the seawater samples collected off the Boso peninsula, Japan and the uranium concentration was found to be ca. 3 μg/L, which is close to the literature data. The yield of the recovery test ranged from 95% to 99%.  相似文献   

19.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

20.
A wall-free detection method based on liquid junction in a capillary gap was proposed for laser-induced fluorescence (LIF) of capillary electrophoresis (CE). The capillary gap of the wall-free cell was fabricated by etching a 10-mm × 50-μm I.D. fused-silica capillary to obtain a polyimide coating sleeve, decoating about 6 mm at one end of both 50 μm I.D. separation and liquid junction capillary, inserting the treated capillary ends into the coating sleeve oppositely, fixing the capillaries with a gap distance of 140 μm by epoxy glue and removing the coating sleeve by burning. The theoretical model, experimental results and wall-free cell images indicated that the gap distance and applied voltage were main influence factors on the wall-free detection. Since the wall-free cell increased the absorption light path and avoided the stray light from the capillary wall, it improved the ratio of signal to noise and limit of detection (LOD) of CE-LIF. Three flavin compounds of riboflavin (RF), flavin mononucleotide sodium (FMN) and flavin adenine dinucleotide disodium (FAD) were used to evaluate the wall-free detection method. Compared with on-column cell, the LODs of the wall-free cell were improved 15-, 6- and 9-fold for RF, FMN and FAD, respectively. The linear calibration concentrations of the flavins ranged from 0.005 to 5.0 μmol/L. The column efficiency was in the range from 1.0 × 105 to 2.5 × 105 plates. The wall-free detection of CE-LIF was applied to the analysis of the flavins in spinach and lettuce leaves.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号