首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 890 毫秒
1.
The present work reports the development of a methodology for the direct determination of lead in high saline waters derived from petroleum exploration employing electrothermal atomic absorption spectrometry with permanent Ir-W and HF as modifiers. These waters, so-called produced waters, have complex composition containing several types of organic and inorganic substances. In order to attain best conditions (highest analytical signal besides lowest background) for the methodology studies about the effect of several variables and the convenient calibration strategy were performed. Also, the efficiency of other modification approaches was evaluated. At best conditions, pyrolysis and atomization temperature were 800 and 2200 °C, respectively, when the modifiers cited above were utilized. Obtained results indicate that, in this kind of sample, lead can be determined by standard addition method or employing external calibration with standard solutions prepared in 0.8 mol l−1 NaCl medium. In order to evaluate the accuracy of the procedure, a recovery test was performed with six spiked samples of produced waters. The detection limit, quantification limit and the relative standard deviation in 0.8 mol l−1 NaCl were also calculated and the values are 1.5 μg l−1, 5.0 μg l−1 and 5.0% (at 10 μg l−1 level), respectively.  相似文献   

2.
This present work reports the development and evaluation of a method for the direct determination of manganese in waters extracted during petroleum exploitation by Electrothermal Atomic Absorption Spectrometry (ET AAS) using Ir-W as permanent modifier. These waters, usually called produced waters, contain a wide range of organic and inorganic substances and are characterized by their high salinity. In order to achieve suitable experimental conditions for the method application, studies about the effect of operational variables (chemical modifier, pyrolysis and atomization temperatures) were performed, as well as the establishment of convenient calibration strategy. The best results were verified when the temperatures of pyrolysis and atomization were 1000 °C and 2300 °C, respectively, and using Ir-W as permanent modifier. The results showed that manganese can be determined by the standard addition method or employing external calibration with standard solutions prepared in the same salinity of the samples (with NaCl). Three real samples with salinities varying between 74 and 84‰ were successfully analyzed by the developed procedure. The limits of detection and quantification were 0.24 and 0.80 μg L−1, respectively, in purified water, and 0.34 and 1.1 μg L−1, respectively, in 0.4 mol L−1 NaCl medium (approximately 23‰ salinity).  相似文献   

3.
In this work, methodologies were developed to determine aluminum (Al), cadmium chromium and lead in drinking water by electrothermal atomic absorption spectrometry using permanent modifiers. No use of modifier, iridium, ruthenium, rhodium and zirconium (independently, 500 μg) were tested to each one analyte through the pyrolysis and atomization temperatures curves. As the matrix is very simple, did not had occurred problems with the background for all metals. The best results obtained for cadmium and chromium was with the use of rhodium permanent modifier. For lead and aluminum, the best choice was the use of zirconium. The selection for the modifier took into account the sensitivity, form of the absorption pulse and low atomization temperature (what contributes to elevate the useful life of the graphite tube). For aluminum using zirconium permanent, the best pyrolysis and atomization temperatures were respectively, of 1000 and 2500 °C with a characteristic mass (1% of absorbance, mo) of 19 pg (recommended of 20 pg). For cadmium, with use of rhodium the best temperatures for the pyrolysis and atomization were respectively of 400 and 1100 °C, with a symmetrical peak and with a mo of 1.0 pg (recommended of 1.0 pg). For chromium with rhodium permanent, the best temperatures for pyrolysis and atomization were respectively of 1000 and 2200 °C, with symmetrical peak and mo of 5.3 pg (recommended of 5.5 pg). For lead with zirconium permanent, the best temperatures for pyrolysis and atomization were of 700 and 2400 °C, with symmetrical peak and with mo of 30 pg (recommended of 20 pg). Water samples spiked with each one of the metals in four different levels inside of the acceptable values presented recoveries always close to 100%. The detection limits were of 0.1 μg l−1 for cadmium; 0.2 μg l−1 for chromium; 0.5 μg l−1 for lead and 1.4 μg l−1 for aluminum.  相似文献   

4.
Flores AV  Pérez CA  Arruda MA 《Talanta》2004,62(3):619-626
In the present paper, lithium was determined in river sediment using slurry sampling and electrothermal atomic absorption spectrometry (ET AAS) after L’vov platform coating with zirconium (as a permanent chemical modifier). The performance of this modifier and its distribution on the L’vov platform after different heating cycles were evaluated using synchrotron radiation X-ray fluorescence (SRXRF) and imaging scanning electron microscopy (SEM) techniques. The analytical conditions for lithium determination in river sediment slurries were also investigated and the best conditions were obtained employing 1300 and 2300 °C for pyrolysis and atomization temperatures, respectively. In addition, 100 mg of sediment samples were prepared using 4.0 mol l−1 HNO3. The Zr-coating permitted lithium determination with good precision and accuracy after 480 heating cycles using the same platform for slurry samples. The sediment samples were collected from five different points of the Cachoeira river, São Paulo, Brazil. The detection and quantification limits were, respectively, 0.07 and 0.23 μg l−1.  相似文献   

5.
Hsiang MC  Sung YH  Huang SD 《Talanta》2004,62(4):791-799
A simple method was developed for the direct and simultaneous determination of arsenic (As), manganese (Mn), cobalt (Co), and nickel (Ni) in urine by a multi-element graphite furnace atomic absorption spectrometer (Perkin-Elmer SIMAA 6000) equipped with the transversely heated graphite atomizer and longitudinal Zeeman-effect background correction. Pd was used as the chemical modifier along with either the internal furnace gas or a internal furnace gas containing hydrogen and a double stage pyrolysis process. A standard reference material (SRM) of Seronorm™ Trace Elements in urine was used to confirm the accuracy of the method. The optimum conditions for the analysis of urine samples are pyrolysis at 1350 °C (using 5% H2 v/v in Ar as the inter furnace gas during the first pyrolysis stage and pure Ar during the second pyrolysis stage) and atomization at 2100 °C. The use of Ar and matrix-free standards resulted in concentrations for all the analytes within 85% (As) to 110% (Ni) of the certified values. The recovery for As was improved when mixture of 5% H2 and 95% Ar (v/v) internal furnace gas was applied during the first step of a two-stage pyrolysis at 1350 °C, and the found values of the analytes were within 91-110% of the certified value. The recoveries for real urine samples were in the range 88-95% for these four elements. The detection limits were 0.78 μg l−1 for As, 0.054 μg l−1 for Mn, 0.22 μg l−1 for Co, and 0.35 μg l−1 for Ni. The upper limits of the linear calibration curve are 60 μg l−1 (As); 12 μg l−1 (Mn); 12 μg l−1 (Co) and 25 μg l−1 (Ni), respectively. The relative standard deviations (R.S.D.s) for the analysis of SRM were 2% or less. The R.S.D.s of a real urine sample are 1.6% (As), 6.3% (Mn), 7.0% (Ni) and 8.0% (Co), respectively.  相似文献   

6.
A flow-batch system was developed for the determination of Fe(III) in estuarine waters with high variability in salinity. The method is based on the catalytic effect of iron(III) on the oxidation rate of N,N-dimethyl-p-phenylenediammonium dichloride (DmPD) by hydrogen peroxide and the formed product is spectrophotometrically monitored at 554 nm. A controlled addition of sodium chloride to every assayed sample is accomplished for in-line individual salinity matching.The proposed system processes about 30 samples h−1 and yields reproducible results. Relative standard deviations were estimated as <1.5% after 10 injections of typical samples (10.0-50.0 μg l−1 Fe; ca. 0.5 mol l−1 Cl). Synthetic samples (15.0 μg l−1 Fe; 0.25-1.0 mol l−1 NaCl) were efficiently processed, and no significant differences in results were found at a probability level of 99.7%. The method works for the full range of salinities. Only 120 μg DmPD are consumed per determination. The analytical curve is linear up to about 60 μg l−1 Fe (r>0.999; n=5) and the detection limit is 5 μg l−1 Fe. Results are in agreement with graphite furnace atomic absorption spectrometry.  相似文献   

7.
A flow system was coupled to a graphite furnace with a platform coated with tungsten-rhodium permanent chemical modifier for in-line separation and preconcentration of copper by employing a minicolumn loaded with 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18-bonded silica fixed in the tip of the autosampler arm. Elution was made by sampling 35 μl of 0.50 mol l−1 HCl with further delivering into a coated platform. Remarkable improvements in both selectivity and sensitivity were observed. Copper(II) was effectively separated from solutions containing up to 20 g l−1 Na+; 10 g l−1 K+, Ca2+ and Mg2+; 1.0 g l−1 Fe3+ and Zn2+. For a sample flowing at 3.0 ml min−1 and a loading of 60 s, the detection limit was estimated as 5 ng l−1 Cu(II) at the 99.7% confidence level, and an enrichment factor of 33 was calculated. Coefficient of variation was estimated as 4% for a 0.30 μg l−1 copper solution (n=20). The W-Rh permanent chemical modifier was used to improve system stability, analytical performance and atomizer lifetime. More than 1500 firings were carried out with the same atomizer without significant variations in sensitivity and precision. On account of the reagent immobilization, its consumption was lower than 0.2 μg per determination. In addition, TAN purification was unnecessary.  相似文献   

8.
A method was developed for the determination of selenium in human milk using electrothermal atomic absorption spectrometry. The use of chemical modifiers as well as their implications during the pyrolysis step was examined. The chemical modifiers that were studied were Zr, Ir as well as the mixed modifier Zr-Ir. The Ir modifier stabilized selenium at 1000 °C, Zr at 800 °C, while the mixed modifier at 1200 °C. The effect of modifier mass was studied and was found that better results are achieved with addition of 2 μg Zr and 2 μg Ir. The characteristic masses of selenium in the presence of Zr, Ir and the mixed modifier were found to be 73.3, 18.0 and 14.7 pg, respectively, while the corresponding limits of detection were found 2.0, 0.50 and 0.41 μg l−1. Consequently better results were obtained with the mixed modifier. The developed method was applied for the determination of selenium in human milk, which was digested with a HNO3 + H2O2 mixture in a microwave oven. The limit of detection of the method was 1.37 μg l−1, the characteristic mass, m0, was 48.8 pg and the repeatability was less than 5% as R.S.D.(%). Matrix matched calibration was used. Recoveries were estimated to be 93-105%. The method was applied to breast milk of Greek women (n = 9) and the Se content was found to be in the range 16.7-42.6 μg l−1 with mean value 27.4 ± 5.5 μg l−1.  相似文献   

9.
A simple and robust time-based on-line sequential injection system for trace mercury determination via cold vapour atomic absorption spectrometry (CVAAS), employing a new integrated gas-liquid separator (GLS), which in parallel operates as reactor, was developed. Sample and reductant are sequentially loaded into the GLS while an argon flow delivers the released mercury vapour through the atomic absorption cell. The proposed method is characterized by the ability of successfully managing variable sample volume up to 30 ml in order to achieve high sensitivity. For 20 ml sample volume, the sampling frequency is 25 h−1. The calibration curve is linear over the concentration range 0.05-5.0 μg l−1 of Hg(II), the detection limit is cL = 0.02 μg l−1, and the relative standard deviation is sr = 2.6% at 1.0 μg l−1 Hg(II) level. The performance of the proposed method was evaluated by analyzing certified reference material and applied to the analysis of natural waters and biological samples.  相似文献   

10.
Acar O 《Talanta》2005,65(3):672-677
Cadmium, copper and lead in soils, sediments and spiked sea water samples have been determined by electrothermal atomic absorption spectrometry (ETAAS) with Zeeman effect background corrector using NH4NO3, Sc, Pd, Sc + NH4NO3, Pd + NH4NO3, Sc + Pd and Sc + Pd + NH4NO3 as chemical modifiers. A comprehensive comparison was made among the modifiers and without modifier in terms of pyrolysis and atomization temperatures, atomization and background absorption profiles, characteristic masses, detection limits and accuracy of the determinations. Sc + Pd + NH4NO3 modifier mixture was found to be preferable for the determination of analytes in soil and sediment certified and standard reference materials, and sea water samples because it increased the pyrolysis temperature up to 900 °C for Cd, 1350 °C for Cu and 1300 °C for Pb. Optimum masses of mixed modifier components found are 20 μg Sc + 4 μg Pd + 8 μg NH4NO3. Characteristic masses of Cd, Cu and Pb obtained are 0.6, 5.3 and 15.8 pg, respectively. The detection limits of Cd, Cu and Pb were found to be 0.08, 0.57 and 0.83 μg l−1, respectively. Depending on the solid sample type, the percent recoveries were increased up to 103% for Cd, Cu and Pb by using the proposed modifier mixture. The accuracy of the determination of analytes in the sea water samples was also increased.  相似文献   

11.
The direct determination of P in biodiesel by high-resolution continuum source graphite furnace atomic absorption spectrometry has been investigated. A slow drying stage proved to be essential for good repeatability. Optimization was performed by a D optimal planning. The atomization temperature and modifier composition were the most relevant parameters. Thus, using a mixture of Pd (30 μg) and Mg(NO3)2 (20 μg) as the modifier, previously deposited onto the platform of the graphite tube and dried, a five step drying stage, and pyrolysis and atomization temperatures of 1000 and 2700 °C, respectively, a limit of detection of 0.5 μg g− 1 was obtained. The analysis of biodiesel of different origins confirmed that external calibration with organic P standard solutions, diluted in P-free biodiesel, could be used. In this way, excellent agreement between the found and expected results was observed in the analysis of an ANP interlaboratorial exercise sample.  相似文献   

12.
This paper proposes a method for the determination of lead in aluminum and magnesium antacids employing electrothermal atomic absorption spectrometry (ET AAS). The pyrolysis and atomization temperatures established during the optimization step were 700 and 2200 °C, respectively, using phosphate as the chemical modifier. Under these conditions, a characteristic mass of 25 pg, and limits of detection and quantification of 0.40 and 1.35 μg L−1, respectively were obtained. Some experiments demonstrated that the calibration can be performed employing the external calibration technique using aqueous standards. The precision expressed as relative standard deviation (RSD %) was 4.03% for an antacid sample with lead concentrations of 284.5 μg L−1. The proposed method was applied for the determination of lead in five antacid samples acquired in Salvador City, Brazil. The lead content was varied from 87 to 943 μg g−1. The samples were also analyzed after complete dissolution by inductively coupled plasma mass spectrometry (ICP-MS). No statistical difference was observed between the results obtained by both of the procedures performed.  相似文献   

13.
The use of a permeation liquid membrane system for the preconcentration and separation of nickel in natural and sea waters and subsequent determination by atomic absorption spectroscopy is presented. 2-Hydroxybenzaldehyde N-ethylthiosemi-carbazone (2-HBET) in toluene is used as the active component of the liquid membrane. A study strategy based on a simplex design has been followed. Several chemical and physical parameters were optimized. Maximum permeation coefficient was obtained at a feed solution pH of 9.4, 0.3 mol l−1 of HNO3 in the stripping solution and 1.66 mmol l−1 of 2-HBTE in toluene as carrier. The precision of the method was 4.7% at 95% significance level and a detection limit of 0.012 μg l−1 of nickel was achieved. The preconcentration procedure showed a linear response within the studied concentration range from 3 to 500 μg l−1 of Ni in the feed solution. The method was validated with different spiked synthetic seawater and certified reference water samples: TMDA-62 and LGC 6016, without matrix interferences and showing good concordance with the certified values, being the relative errors −5.9% and −2.2%, respectively. Under optimal conditions, the average preconcentration yield for real seawater samples was 98 ± 5%, with a nickel preconcentration factor of 20.83 and metal concentrations ranging between 2.8 and 5.4 μg l−1.  相似文献   

14.
This work assesses for the first time the potential of natural Kaolinite as adsorptive material for preconcentration of metal traces. Manganese is quantitatively retained by 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) on thermal modified Kaolinite by column method in pH range of 8.5-10.0 at flow rate of 2 ml min−1. Manganese was removed from column with 5.0 ml of H2SO4 4 mol l−1 and determined by flame atomic absorption spectrometric at 279.5 nm. In this case, 0.l μg of manganese can be concentrated from 800 ml of aqueous sample (where concentration is as low as 0.125 μg l−1). Detection limit is 4.3 μg l−1 (3 δbl m−1) and analytical curve is linear in the 0.02-10 mg l−1 in final solution with correlation coefficient 0.9997 and relative standard deviation for eight replicate determination of 5 μg of manganese in final solution is 0.71%. The interference of a large number of anions and cations has been studied in detail to optimize the conditions and method was successfully applied for determination of manganese in complex materials.  相似文献   

15.
A sensitive and selective method was developed for the determination of traces of manganese in urine using on-line electrochemical preconcentration followed by flame atomic absorption spectrometry detection. A home made flow-through polypropylene cell (4.5 cm long × 0.8 cm diameter filled with glass marbles) with an effective inner volume of 0.5 ml containing a working and a counter electrode, both of glassy carbon and a Pt pseudo reference electrode was located in a flow injection manifold specially designed for the purpose of this work. The manganese was deposited from buffer solution of NH3/NH4Cl at pH 9.00 through an oxidizing process at a current of 400 mA during 7 min. A flow of HCl 0.1 mol l−1 at 4 ml min−1 through the cell, chemically dissolved the deposit. A small portion (15 μl) of the concentrate was introduced in a continuously flowing system by means of a timing device and was then carried to the detector for the manganese quantification. All electrochemical and spectroscopic variables as well as possible interferences in both systems were systematically studied. The relative standard deviations for ten consecutive measurements of manganese solutions of 2.0 and 20 μg l−1 were of 2.3 and 1.5%, respectively, while for a sample processed five times was less then 5%. The accuracy of the developed procedure was evaluated by adding known amounts of manganese standard to urine samples and following the whole procedure. Recoveries within the range 97.2-102.8% were obtained. To further prove the accuracy, a Seronorm Trace Elements in Urine, Batch 403125 sample with a reported concentration of 13 μg Mn l−1 was also analyzed. The experimental value obtained was of 12.7 ± 0.1 μg l−1, which does not differ significantly from the reported amount (p < 0.05). A preconcentration factor of 40, a linear range between 0.015 and 60 μg l−1 and a limit of detection of 15 ng l−1 permitted the determination of manganese in real urine samples from non-exposed subjects in the range 0.5-2.8 μg l−1.  相似文献   

16.
Correia PR  Oliveira PV 《Talanta》2005,67(1):46-53
The effectiveness of internal standardization for simultaneous atomic absorption spectrometry (SIMAAS) was investigated for As and Se determination in urine. Co and Sn were selected as internal standard (IS) candidates based on the evaluation of some physico-chemical parameters related to the atomization. Correlation graphs, plotted from the normalized absorbance signals (n = 20) of internal standard (axis y) versus analyte (axis x), precision, and accuracy of the analytical results were the supportive parameters to choose Co as the most appropriate IS. The urine samples were diluted 1 + 2 to 1.0% (v/v) HNO3 + 80 μg L−1 Co2+. The mixture 20 μg Pd + 3 μg Mg was used as chemical modifier and the optimized temperatures for pyrolysis and atomization steps were 1400 and 2300 °C, respectively. The characteristic masses for As (47 ± 1 pg) and Se (72 ± 2 pg) were estimated from the analytical curves. The detection limits (n = 20, 3δ) were 1.8 ± 0.1 and 2.6 ± 0.1 μg L−1 for As and Se, respectively. The reliability of the entire procedure was checked with the analysis of certified reference material from Sero AS(Seronorm™ Trace Elements in Urine). The obtained results showed the matrix interference disallowed the instrument calibration with aqueous standards. The best analytical condition was achieved when matrix-matched standards were used in combination with Co as IS, which improved the recoveries obtained for As. Under this experimental condition, eight urine samples were analysed and spiked with 10 and 25 μg L−1 As and Se. The mean recoveries were 96 ± 6% (10 μg L−1 As), 95 ± 6% (25 μg L−1 As), 101 ± 7% (10 μg L−1 Se), and 97 ± 4% (25 μg L−1 Se).  相似文献   

17.
In the present work, thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was employed for Cu and Zn determination in bovine milk and fruit juice samples without any pretreatment. TS-FF-AAS system was optimized and a sample volume of 300 μl was injected into the carrier stream (0.014 mol l−1 HNO3 at a flow rate of 0.4 ml min−1), and it was introduced into a hot Ni tube. The detection limits obtained for Cu and Zn in aqueous solution were 2.2 and 0.91 μg l−1, respectively, and 3.2 μg l−1 for Cu in a medium containing water-soluble tertiary amines. The relative standard deviations varied from 2.7 to 4.2% (n=12). Sample preparation was carried out by simple dilution in water or in water-soluble tertiary amines medium. Accuracy was checked by performing addition-recovery experiments as well as by using reference materials (whole milk powder, non-fat milk powder, and infant formula). Recoveries varied from 97.7 to 105.3% for Cu and Zn. All results obtained for reference materials were in agreement with certified values at a 95% confidence level.  相似文献   

18.
An analytical procedure for determination of As(III) and As(V) in soils using sequential extraction combined with flow injection (FI) hydride generation atomic fluorescence spectrometry (HG-AFS) was presented. The soils were sequentially extracted by water, 0.6 mol l−1 KH2PO4 solution, 1% (v/v) HCl solution and 1% (w/v) NaOH solution. The arsenite (As(III)) in extract was analyzed by HG-AFS in the medium of 0.1 mol l−1 citric acid solution, then the total arsenic in extract was determined by HG-AFS using on-line reduction of arsenate with l-cysteine. The concentration of arsenate (As(V)) was calculated by the difference. The optimum conditions of extraction and determination were studied in detail. The detection limit (3σ) for As(III) and As(V) were 0.11 and 0.07 μg l−1, respectively. The relative standard deviation (R.S.D.) was 1.43% (n=11) at the 10 μg l−1 As level. The method was applied in the determination of As(III) and As(V) of real soils and the recoveries of As(III) and As(V) were in the range of 89.3-118 and 80.4-111%, respectively.  相似文献   

19.
A.S. Alves Ferreira 《Talanta》2007,72(3):1223-1229
This paper deals on the determination of Strychnine, a potent and dangerous pesticide and the analytical procedure is based on the photo-induced chemiluminescence of the pesticide by means of the Multicommutation continuous-flow methodology. Small segments of the pesticide solution were sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. The required time of UV irradiation was obtained by stopped-flow during 150 s; then, the resulting solution formed alternated segments with the oxidizing solution containing 5 × 10−3 mol l−1 Ce(IV) in 0.6 mol l−1 nitric acid. The calibration range, from 2 μg l−1 to 50 mg l−1, resulted in a linear behaviour over the range 25 μg l−1 to 20 mg l−1 and fitting the equation: I = 4706x + 624 with a correlation coefficient of 0.9955. The limit of detection was 2 μg l−1 and the sample throughput 15 h−1. After testing the influence of a large series of potential interferents, the method was applied to different kinds of samples.  相似文献   

20.
A three-phase liquid microextraction procedure for the determination of mercury at low concentrations is discussed. To the aqueous sample placed at pH 7 by means of a phosphate buffer, 0.002% (m/v) 1-(2-pyridylazo)-2-naphthol (PAN) is incorporated, and the mixture submitted to microextraction with a hollow-fiber impregnated with toluene and whose lumen contains a 0.05 mol L−1 ammonium iodide solution. The final measurement of the extract is carried out by electrothermal atomic absorption spectrometry (300 °C and 1100 °C for the calcination and atomization temperatures, respectively). The pyrolytic graphite atomizer is coated electrolytically with palladium. An enrichment factor of 270, which results in a 0.06 μg L−1 mercury for the detection limit is obtained. The relative standard deviation at the 1 μg L−1 mercury level is 3.2% (n = 5). The reliability of the procedure is verified by analyzing waters as well as six certified reference materials.  相似文献   