相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
A program for simulation of ion trajectories in ion mobility spectrometry (IMS) instruments has been developed and incorporated into SIMION 7.0 [Int. J. Mass Spectrom. 200 (2000) 3–25]. Simulations were based on elastic collisions between ions and gas particles and conducted for an IMS drift tube. The program was validated by comparing the reduced mobility of helium ions derived from the simulation with the experimental data for helium ions in neon drift gas in low electric fields. Typical IMS parameters, including pressure, temperature, and flow rate of the drift gas were taken into account in the simulations. The program demonstrates capabilities of generating IMS spectra and predicting ion transport efficiency and separating ions. For the IMS drift tube studied, a correlation between imperfection of the electric field distribution and low resolution has been observed.  相似文献   

2.
An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.  相似文献   

3.
一种基于离子迁移谱的气相色谱检测器及其应用   总被引:2,自引:0,他引:2  
Cheng S  Chen C  Wang W  Du Y  Han F  Li L  Zhou Q  Zhang X  Li H 《色谱》2011,29(9):901-907
离子迁移谱作为气相色谱的检测器,兼有色谱的高分离能力和离子迁移谱的高灵敏度,有利于实现复杂混合物的实时在线监测。基于在色谱、离子迁移谱方面的研究基础,本实验室搭建了一套以离子迁移谱为检测器的气相色谱仪,分别对检测器的温度、总电压、尾吹气流速等参数进行了系统优化,并用于碘甲烷、1,2-二氯乙烷、四氯化碳和二溴甲烷4种卤代烃化合物的检测。实验结果表明,参数优化后的离子迁移谱检测器对碘甲烷、1,2-二氯乙烷、四氯化碳和二溴甲烷的检出限可分别达到2、0.02、1和0.1 ng,线性范围有两个数量级。离子迁移谱与气相色谱联用,其二维的分离能力可以为复杂混合物的准确定性提供更多的信息,还可以实现不同化合物的选择性检测。  相似文献   

4.
Throughput has been improved in an ion-mobility spectrometer by means of continuous ion-beam modulation and phase-resolved detection. Conventional ion-mobility spectrometry (IMS) utilizes brief packets of ions for separation in the gas phase. In contrast, this preliminary report outlines a new detection method based on phase resolution and involves monitoring the ion signal continuously, which raises the duty cycle of the instrument from approximately 1% (conventional IMS) to 50%. The greater duty cycle is shown to improve signal-to-noise ratios (S/N). However, the higher S/N levels did not translate into higher sensitivity values when calibration plots were constructed. It is demonstrated that even analytes with small differences in drift times can be modulated at frequencies that maximize the measured phase differences between ions. Phase-resolved signals can be processed with a Fourier transform and chemometric data reduction to simplify identification of the analyte from its phase spectra.  相似文献   

5.
一种微型FAIMS传感器芯片的研制   总被引:1,自引:0,他引:1  
李华  王晓浩  唐飞  张亮  杨吉  吝涛  丁力 《物理化学学报》2010,26(5):1355-1363
基于微机电系统(MEMS)技术,研制了一种微型高场非对称波形离子迁移谱(FAIMS)传感器芯片.芯片尺寸为18.8mm×12.4mm×1.2mm,由离子化区、迁移区、离子检测区组成.采用真空紫外灯离子源在大气压环境下对样品进行离子化,经过离子化区中聚焦电极的电场作用,实现离子在进入迁移区之前的聚焦,提高离子信号的强度.通过在上下玻璃上溅射Au/Cr(300nm/30nm)金属,并与厚度为200μm、采用感应耦合等离子体(ICP)工艺刻蚀的硅片键合,形成迁移区的矩形通道,尺寸为10mm×5mm×0.2mm.离子检测区为三排直径200μm、间距100μm交错排列的圆柱阵列式微法拉第筒,能同时检测正负离子.采用频率为2MHz,最大电压为364V,占空比为30%的高场非对称方波电压进行FAIMS芯片实验.以丙酮和甲苯为实验样品,载气流速80L·h-1,补偿电压从-10V到3V以0.1V的步长进行扫描,得到了丙酮和甲苯的FAIMS谱图,验证了FAIMS芯片的性能.丙酮和甲苯的FAIMS-MS实验进一步表明FAIMS系统实现了离子分离和过滤功能.  相似文献   

6.
Using a simple ion source set-up, laser desorption/ionization on silicon (DIOS) was demonstrated with the use of a custom-made drift tube ion mobility spectrometer (IMS), mounted on a commercial triple quadrupole mass spectrometer, and with an IMS equipped with a Faraday plate detector. DIOS was tested by mobility measurement of tetrapropylammonium iodide, tetrabutylammonium iodide and tetrapentylammonium iodide, whilst 2,6-di-tert- butylpyridine was used as a standard. The reduced mobilities measured for the test halides are in concordance with previously obtained ion mobility spectrometry-mass spectrometry data.  相似文献   

7.
The performance of the IMS was influenced by many parameters, like temperature, gas flow rate, etc. in the drift tube. An exact and comprehensive simulation model was very useful for the IMS design and optimization. A combined simulation model was build up for the parameters simulation in the drift tube. Based on this simulation model, the heat transfer, velocity distribution, humidity and ion transportation inside the drift tube in bidirectional flow stream was simulated, and the impact on the IMS was studied. And the simulation was also validated using an IMS constructed in our laboratory. The experiment showed that the RIP intensity weakened as the humidity increasing, but the signal intensity of NO was enhanced first, and then decreased with the humidity increasing sequentially. This can be explained from the simulation results. The simulation results showed that the distribution of the velocity and temperature was not uniformed in the drift tube. And this phenomenon was more clearly when the gas flow velocity increased. It can be seen from the simulation that the humidity in the drift tube region was smaller than the sample moisture, and the resolution of the ion mobility spectrometry will be reduced by the humidity. But in the region rich in water molecules, ultraviolet photons re-acting with acetone would be obviously decreased and fewer re-agent ions were produced owing to the strong absorption of photons by water neutrals. The results showed that the coupled field simulation model can be used to study parameters effects on the IMS.  相似文献   

8.
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two‐dimensional separation. To improve the performance of hyphenated CE‐IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 μL/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5–250 μg/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 μg/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE‐ESI‐IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra‐violet transparent compounds or none fluorescent compounds.  相似文献   

9.
In recent years, the resolving power of ion mobility instruments has been increased significantly, enabling ion mobility spectrometry (IMS) to be utilized as an analytical separation technique for complex mixtures. In theory, decreasing the drift tube temperature results in increased resolution due to decreased ion diffusion. However, the heat requirements for complete ion desolvation with electrospray ionization (ESI) have limited the reduction of temperatures in atmospheric pressure ion mobility instruments. Micro-electrospray conditions were investigated in this study to enable more efficient droplet formation and ionization with the objective of reducing drift tube temperatures and increasing IMS resolution. For small molecules (peptides), the drift tube temperature was reduced to ambient temperature with good resolution by employing reduced capillary diameters and flow rates. By employing micro-spray conditions, experimental resolution values approaching theoretically predicted resolution were achieved over a wide temperature range (30 to 250 °C). The historical heat requirements of atmospheric pressure IMS due to ESI desolvation were eliminated due to the use of micro-spray conditions and the high-resolution IMS spectra of GLY-HIS-LYS was obtained at ambient temperature. The desolvation of proteins (cytochrome c) was found to achieve optimal resolution at temperatures greater than 125 °C. This is significantly improved from earlier IMS studies that required drift tube temperatures of 250°C for protein desolvation.  相似文献   

10.
A new and fast method for measuring the diffusion coefficients of binary gas mixtures using ion mobility spectrometry (IMS) has been developed. In this method, the sample is injected as a short pulse into the flowing drift gas, forming a Gaussian concentration profile inside the drift region. This Gaussian cloud is irradiated with a fast moving swarm of electrons to create negative ions. The flash of electrons is so short that the negative ions do not move much during the exposure time. The ions then drift toward the detector, where they are collected. The collected ion signal pattern reflects the spatial distribution of the sample inside the cloud at the time of exposure. This is repeated in intervals of 300-400 ms to monitor the spatial spreading of the molecules in the drift region. Consecutive IMS spectra show the evolution of the cloud over time. The collected spectra are fit to Gaussian functions to extract diffusion coefficients. Using this method, the diffusion coefficient of O(2), CHCl(3), and C(2)H(2)Cl(2) were measured, and the results are in good agreement with the previously reported experimental data.  相似文献   

11.
In the present work we describe the principles of operation, versatility and applicability of a trapped ion mobility spectrometer (TIMS) analyzer for fast, gas-phase separation of molecular ions based on their size-to-charge ratio. Mobility-based separation using a TIMS device is shown for a series for isobar pairs. In a TIMS device, mobility resolution depends on the bath gas velocity and analysis scan speed, with the particularity that the mobility separation can be easily tuned from low to high resolution (R?>?50) in accordance with the analytical challenge . In contrast to traditional drift tube IMS analyzer, a TIMS device can be easily integrated in a mass spectrometer without a noticeable loss in ion transmission or sensitivity, thus providing a powerful separation platform prior to mass analysis.  相似文献   

12.
Ion mobility spectrometry has become the most successful and widely used technology for the detection of trace levels of nitro-organic explosives on handbags and carry on-luggage in airports throughout the US. The low detection limits are provided by the efficient ionization process, namely, atmospheric pressure chemical ionization (APCI) reactions in negative polarity. An additional level of confidence in a measurement is imparted by characterization of ions for mobilities in weak electric fields of a drift tube at ambient pressure. Findings from over 30 years of investigations into IMS response to these explosives have been collected and assessed to allow a comprehensive view of the APCI reactions characteristic of nitro-organic explosives. Also, the drift tube conditions needed to obtain particular mobility spectra have been summarized. During the past decade, improvements have occurred in IMS on the understanding of reagent gas chemistries, the influence of temperature on ion stability, and sampling methods. In addition, commercial instruments have been refined to provide fast and reliable measurements for on-site detection of explosives. The gas phase ion chemistry of most explosives is mediated by the fragile CONO(2) bonds or the acidity of protons. Thus, M(-) or M.Cl(-) species are found with only a few explosives and loss of NO(2), NO(3) and proton abstraction reactions are common and complicating pathways. However, once ions are formed, they appear to have stabilities on time scales equal to or longer than ion drift times from 5-20 ms. As such, peak shapes in IMS are suitable for high selectivity and sensitivity.  相似文献   

13.
Protonated ammonia and hydrazines (MH(+)) form complexes with ketones and the differences in masses and mobilities of the resulting ions, MH(+)(ketone)(n), are sufficient for separation in an ion mobility spectrometer at ambient pressure. The highest mass ion for any of the protonated molecules is obtained when the ketone is present at elevated concentrations in the supporting atmosphere of both the source and drift regions of the spectrometer so that an ion maintains a discrete composition and mobility. The sizes of the ion-molecule complexes were found to depend on the number of H atoms on the protonated nitrogen atom--four for ammonia, three for hydrazine, two for monomethylhydrazine, and one for 1,1-dimethylhydrazine, and the drift times of these ions were proportional to the size of the ion-molecule complex. Unexpected side products, including protonated hydrazones and azines, and associated ketone clusters, were isolated to a single drift tube containing ceramic parts and could not, from CID studies, be attributed to gas-phase ion chemistry. These findings illustrate that mobility resolution of ions in IMS and IMS/MS experiments can be enhanced through chemical modification of the supporting gas atmosphere without changes in the core ion.  相似文献   

14.
An ion mobility detector has been designed and constructed for direct axial interfacing with capillary gas chromatography. The principle advantages of this detector were the following: (1) Direct concentric introduction of the capillary column into the ionization region, eliminating peak broadening in the transfer line and improving the efficiency with which neutral molecules were swept from the detector. (2) A variable capillary insertion distance, providing a sensitivity/resolution interplay that could be modified in response to the needs of the assay. (3) An inert gas flow external to the drift cylinder, preventing atmospheric impurities from infiltrating the ultratrace detector. Qualitative and quantitative capabilities of the detector were evaluated using standard preparations of n-hexyl ether.  相似文献   

15.
Low field atmospheric pressure Ion Mobility Spectroscopy (IMS) involves the careful analysis of plasmagrams with multiple peaks which can mask one another when they are closely spaced in drift time or corresponding reduced mobility. A typical signal processing approach to decomposing overlapped peaks would be to use an orthogonal decomposition technique, but unfortunately Gaussian-like functions are not orthogonal, so no unique decomposition can be guaranteed. However, each ion species in the drift tube will arrive at the Faraday plate with a known statistical distribution determined by the IMS instrument’s drift tube design, electric field strength, reagent gas flow and other instrument-specific factors such as the ion gate function. This paper presents a straightforward algorithm for decomposing plasmagrams into distinct peaks using a subtractive technique that independently estimates the statistical parameters of each peak, rejecting spurious peaks and electrical noise. The results show that for relatively short gate times, the plasmagram peaks are nearly Gaussian-shaped, but slightly fatter and asymmetric. We show that including of the gate rise and fall times is also significant in matching the plasmagram peak shape. We also show that the diffusion effects on resolution can be attributed to combinations of non-uniform ion distributions in the reaction chamber as well as detritus effects in the drift tube. Given the known peaks statistical parameters, one can then separate overlapping peaks using a straightforward spectral subtractive technique.  相似文献   

16.
17.
Atmospheric pressure chemical ionization and ion mobility spectrometry (IMS) have traditionally been viewed as a qualitative analytical technique for identifying specific chemicals in the atmosphere. This work employs a nonlinear model based on molecular collision rate theory for quantitative modeling of chemical analyte concentrations. The collision rate between any two molecules depends on the relative populations of each chemical species in the volume of air analyzed where most collisions between ions, or neutral molecules and ions, result in no charge transfer. The rate constants for formation of product ions and consumption of source ions are estimated using empirical data over a wide concentration range for several analytes and reagent gases. The rate constants are unique to the analyte and the reagent gas as well as the sensitivity of the particular IMS instrument and provide a quantitative model to relate the mobility peak amplitudes to the analyte concentration. The rate constants can also be normalized by the reaction ion consumption rate constant to remove the IMS instrument sensitivity and provide a qualitative metric for analyte identification independent of a particular IMS instrument. A quantitative example is given for an acetic acid plume measured by a hand-held IMS detector outdoors has the plume passes. The quantitative rate constants provide a reasonable basis for estimating analyte concentration from the ion mobility spectra over a wide range of analyte concentrations.  相似文献   

18.
The ability of ion mobility spectrometry coupled with mass spectrometry (IMS-MS) to characterize biological mixtures has been illustrated over the past eight years. However, the challenges posed by the extreme complexity of many biological samples have demonstrated the need for higher resolution IMS-MS measurements. We have developed a higher resolution ESI-IMS-TOF MS by utilizing high-pressure electrodynamic ion funnels at both ends of the IMS drift cell and operating the drift cell at an elevated pressure compared with that conventionally used. The ESI-IMS-TOF MS instrument consists of an ESI source, an hourglass ion funnel used for ion accumulation/injection into an 88 cm drift cell, followed by a 10 cm ion funnel and a commercial orthogonal time-of-flight mass spectrometer providing high mass measurement accuracy. It was found that the rear ion funnel could be effectively operated as an extension of the drift cell when the DC fields were matched, providing an effective drift region of 98 cm. The resolution of the instrument was evaluated at pressures ranging from 4 to 12 torr and ion mobility drift voltages of 16 V/cm (4 torr) to 43 V/cm (12 torr). An increase in resolution from 55 to 80 was observed from 4 to 12 torr nitrogen drift gas with no significant loss in sensitivity. The choice of drift gas was also shown to influence the degree of ion heating and relative trapping efficiency within the ion funnel.  相似文献   

19.
The comparison of nanospray and microspray ionizations for detecting mixtures of compounds by ion mobility spectrometry has been investigated for sensitivity, ion transmission through a drift tube, and ion suppression effects when used as an ionization source for ambient pressure ion mobility spectrometry (IMS). Several articles have demonstrated that nano-electrospray ionization mass spectrometry (n-ESI-MS) has improved sensitivity, provides less background noise, and lower limits of detection than micro-electrospray ionization (μ-ESI) for IMS. Most importantly, data from n-ESI-MS is concentration-sensitive. Our laboratory previously published an article that observed a striking result when μ-ESI-IMS was investigated for a single compound in the positive ion mode. The data reported was mass-sensitive. In this new investigation, we have investigated mixtures, and experiments were designed to evaluate the effect of sensitivity, ion transmission and ion suppressions in μ-ESI-IMS and n-ESI-IMS. At an electrospray flow rate in the μL min−1 range, compounds with higher proton affinities responded best while at the nanospray flow rates of nL min−1, relative responses were more equal. This study observed that a decreased ESI flow rate resulted in a decreased ion signal. These trends demonstrated less sensitivity for ESI-IMS at reduced flow rates but suggest better quantification. At higher flow rates, relative ionization efficiencies were still uniform for all the components studied individually and in mixtures and sensitivity improved by about 78%. Concentration studies showed that at high concentrations, ion detection efficiencies were uniform at about 33% for all compounds studied individually and in mixtures. At low concentrations, the detection efficiency varied from 31% to 86%, depending on the proton affinity of the component in the mixture. Ion transmission through the IMS tube measured with a segmented Faraday detector that was incorporated into the IMS design indicated that most of the ion current for mixtures was transported through the IMS tube with a radius of less than 18 mm for both positive and negative ion modes.  相似文献   

20.
Benzodiazepines are a commonly abused class of drugs; requiring analytical techniques that can separate and detect the drugs in a rapid time period. In this paper, the two-dimensional separation of five benzodiazepines was shown by electrospray ionization (ESI) ion mobility spectrometry (IMS)-mass spectrometry (MS). In this study, both the two dimensions of separation (m/z and mobility) and the high resolution of our IMS instrument enabled confident identification of each of the five benzodiazepines studied. This was a significant improvement over previous IMS studies that could not separate many of the analytes due to low instrumental resolution. The benzodiazepines that contain a hydroxyl group in their molecular structure (lorazepam and oxazepam) were found to form both the protonated molecular ion and dehydration product as predominant ions. Experiments to isolate the parametric reasons for the dehydration ion formation showed that it was not the result of corona discharge processes or the potential applied to the needle. However, the potential difference between the needle and first drift ring did influence both the relative intensity ratios of the two ions and the ion sensitivity.  相似文献   