首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
Herba Epimedii (known as Yinyanghuo in China) is one of the commonly used Chinese medicines. Flavonoids are considered as its active components. In this study, a CEC method was developed for the simultaneous determination of seven flavonoids, including hexandraside E, kaempferol-3-O-rhamnoside, hexandraside F, icariin, epimedin A, B, and C, in Epimedium using baicalein as internal standard (IS). The influence of relevant parameters such as buffer concentration, pH, and proportion of ACN was investigated and optimized. Baseline separation was obtained using a Hypersil C18 capillary (3 microm, 100 microm/25 cm) with a mixture of 20 mM phosphate buffer (pH 4.0)/ACN (70:30 v/v) as mobile phase running at 30 kV and 25 degrees C in 20 min. All calibration curves showed good linearity (r2 >0.9992) within test ranges. The LOD and LOQ were lower than 8.6 and 42.8 microg/mL, respectively. The RSDs of intra- and interday for relative peak areas of seven analytes were less than 3.1 and 4.4%, and the recoveries were 95.2-103.3%. Samples of different Epimedium species were analyzed using the validated method, which is useful for quality control of Epimedium and its medical preparations.  相似文献   

2.
Norton D  Rizvi SA  Shamsi SA 《Electrophoresis》2006,27(21):4273-4287
The CEC-MS of alkyltrimethylammonium (ATMA+) ions with chain lengths ranging from C1-C18 is optimized using an internally tapered column packed with mixed mode reversed phase/strong cation exchange stationary phase. A systematic study of the CEC separation parameters is conducted followed by evaluation of the ESI-MS sheath liquid and spray chamber settings. First, the optimization of CEC separation parameters are performed including the ACN concentration, triethylamine (TEA) content, buffer pH and ammonium acetate concentration. Using 90% v/v ACN with 0.04% v/v TEA as mobile phase, the separation of longer chain C6-C18-TMA+ surfactants could be achieved in 15 min. Lowering the ACN concentration to 70% v/v provided resolution of shorter chain C1, C2-TMA+ from C6-TMA+ although the total analysis time increased to 40 min. Furthermore, variation of both the ACN and TEA content as well as ionic strength has found to significantly influence the retention of longer chain surfactants as compared to shorter chains. The optimum CEC conditions are 70% v/v ACN, 0.04% v/v TEA, pH 3.0 and 15 mM ammonium acetate. Next, the optimization of the ESI-MS sheath liquid composition is conducted comparing methanol to isopropanol followed by the use of experimental design for analysis of spray chamber parameters. Overall, the developed CEC-ESI-MS method allows quantitative and sensitive monitoring of ATMA+ from < or =10 microg/mL down to 10 ng/mL. Utilizing the optimized CEC-ESI-MS protocol, the challenging analysis of commercial sample Arquad S-50 ATMA+ containing cis-trans unsaturated and saturated soyabean fatty acid derivatives is demonstrated.  相似文献   

3.
In this work, a novel polysaccharide‐based chiral stationary phase, cellulose tris(4‐chloro‐3‐methylphenylcarbamate), also called Sepapak 4 has been evaluated for the chiral separation of amlodipine (AML) and its two impurities. AML is a powerful vasodilatator drug used for the treatment of hypertension. Capillary columns of 100 μm id packed with the chiral stationary phase were used for both nano‐LC and CEC experiments. The optimization of the mobile phase composed of ACN/water, (90:10, v/v) containing 15 mM ammonium borate pH 10.0 in nano‐LC allowed the chiral separation of AML and the two impurities, but not in a single run. With the purpose to obtain the separation of the three pairs of enantiomers simultaneously, CEC analyses were performed in the same conditions achieving better enantioresolution and higher separation efficiencies for each compound. To fully resolve the mixture of six enantiomers, parameters such as buffer pH and concentration sample injection have been then investigated. A mixture of ACN/water (90:10, v/v) containing 5 mM ammonium borate buffer pH 9.0 enabled the complete separation of the three couples of enantiomers in less than 30 min. The optimized CEC method was therefore validated and applied to the analysis of pharmaceutical formulation declared to contain only AML racemate.  相似文献   

4.
The separation of several insect oostatic peptides (IOPs) was achieved by using CEC with a strong-cation-exchange (SCX) stationary phase in the fused-silica capillary column of 75 microm id. The effect of organic modifier, ionic strength, buffer pH, applied voltage, and temperature on peptides' resolution was evaluated. Baseline separation of the studied IOPs was achieved using a mobile phase containing 100 mM pH 2.3 sodium phosphate buffer/water/ACN (10:20:70 v/v/v). In order to reduce the analysis time, experiments were performed in the short side mode where the stationary phase was packed for 7 cm only. The selection of the experimental parameters strongly influenced the retention time, resolution, and retention factor. An acidic pH was selected in order to positively charge the analyzed peptides, the pI's of which are about 3 in water buffer solutions. A good selectivity and resolution was achieved at pH <2.8; at higher pH the three parameters decreased due to reduced or even zero charge of peptides. The increase in the ionic strength of the buffer present in the mobile phase caused a decrease in retention factor for all the studied compounds due to the decreased interaction between analytes and stationary phase. Raising the ACN concentration in the mobile phase in the range 40-80% v/v caused an increase in both retention factor, retention time, and resolution due to the hydrophilic interactions of IOPs with free silanols and sulfonic groups of the stationary phase.  相似文献   

5.
The separation and simultaneous determination of caffeine, paracetamol, and acetylsalicylic acid in two analgesic tablet formulations was investigated by capillary electrochromatography (CEC). The effect of mobile phase composition on the separation and peak efficiency of the three analytes was studied and evaluated; in particular, the influence of buffer type, buffer pH, and acetonitrile content of the mobile phase was investigated. The analyses were carried out under optimized separation conditions, using a full-packed silica capillary (75 microm ID; 30.0 cm and 21.5 cm total and effective lengths, respectively) with a 5 microm C8 stationary phase. A mixture of 25 mM ammonium formate at pH 3.0 and acetonitrile (30:70 v/v) was used as the mobile phase. UV detection was at 210 nm. Good linearity was found in the range of 50-200, 20-160, and 4-20 microg/mL for acetylsalicylic acid (r2=0.9988), paracetamol (r2=0.9990) and caffeine (r2=0.9990), respectively. Intermediate precision (RSD interday) as low as 0.1-0.8% was found for retention times, while the RSD values for the peak area ratios (Aanalyte/AIS) were in the range of 1.9-2.9%. The optimized CEC method was applied to the analysis of the studied compounds present in commercial tablets.  相似文献   

6.
Lu M  Zhang L  Feng Q  Xia S  Chi Y  Tong P  Chen G 《Electrophoresis》2008,29(4):936-943
A pressure-assisted CEC (pCEC) with ESI-MS based on silica-based monolithic column was developed for rapid analysis of narcotics. Combining the extremely high permeability and separation efficiency of silica-based monolithic column with the high selectivity and sensitivity of pCEC-ESI-MS, the developed system exhibited its prominent advantages in separation and detection. A systematic investigation of the pCEC separation and ESI-MS detection parameters was performed. Experiment results showed that the optimized separation efficiency could be obtained at 8 bar assisted pressure with 25 kV separation voltage, using the solution containing 65% ACN v/v and 20 mmol/L ammonium acetate with pH 6.0 as running buffer. 3 microL/min of sheath liquid was considered as the optimized flow rate since it could provide the maximum signal intensity. Under the optimum conditions, the tested five narcotics could be completely separated within 10 min with the detection limit in the range of 2.0-80 nmol/L. The proposed method has been successfully used for detection of narcotics in real urine samples.  相似文献   

7.
A simple and rapid method for the isocratic separation and determination of carotenoids (carotenes and xanthophylls) in vegetables by CEC is described. The capillary column (100 microm ID, 25 cm effective length) was packed with 3 microm Hypersil ODS particles. The optimized mobile phase contained 60% ACN, 35% THF and 5% of a 5 mM Tris aqueous buffer of pH 8. beta-Carotene, lycopene and lutein were separated with efficiencies of 66 000-128 000 plates/m within a short time (less than 12 min for the last peak eluted, 13/13'-cis-beta-carotene). An excellent resolution of the three carotenoids, as well as partial resolution of their geometrical isomers, was achieved. Application to the determination of the analytes in carrot, tomato, spinach and corn was demonstrated.  相似文献   

8.
Chang CH  Chen CJ  Chuang YC  Her GR 《Electrophoresis》2006,27(21):4303-4311
CEC-MS has been used for the analysis of eight-triazine herbicides. It showed significantly better S/N ratio than reversed EOF CE-MS and MEKC-MS, due to the lack of a surfactant in the separation buffer. By optimizing the pH, the organic content of the running buffer, and the separation potential, optimal separation was achieved within 18 min using a running buffer of pH 7.0, containing 70% v/v ACN, and an applied voltage of 17 kV. Gradient CEC showed superior separation when compared with isocratic elution. The combination of a tapered CEC column and a low-flow interface confers several advantages including better sensitivity, low dead volume, and independent control of the conditions used for CEC separation and ESI analysis.  相似文献   

9.
Wu X  Wang L  Xie Z  Lu J  Yan C  Yang P  Chen G 《Electrophoresis》2006,27(4):768-777
An isocratic elution pressurized CEC (pCEC) system was used to separate and determine ten carbamate insecticides. It was found that introduction of the electrical field, supplementary pressure, and SDS in the proposed method greatly improved the speed, column efficiency, selectivity, and repeatability for separation and determination of carbamates. On a capillary column of 75 microm ID packed with 3 microm octadecyl silica, baseline separation and detection of ten analytes was performed by using a mobile phase consisting of 30% v/v ACN and 70% v/v of 5 mmol/L ammonium acetate (pH 6.5) containing 1 mmol/L SDS and 0.01% triethylamine (TEA). Under the optimum conditions ten carbamate insecticides could be completely separated within 20 min. For the real vegetable samples, an SPE procedure for the cleanup of matrices was carried out prior to pCEC analysis. The detection limits of 0.05-1.6 mg/kg for ten carbamates and mean recoveries of 51.3-109.2% for eight kinds of vegetable samples at different concentrations of carbamates with RSD less than 11.4% were obtained, respectively. The proposed method has been proved to be effective in the rapid analysis of carbamate residues in vegetables.  相似文献   

10.
A pressure‐assisted CEC with ESI‐MS based on poly(1‐hexadecene‐co‐trimethylolpropane trimethacrylate) monolithic column for rapid analysis of two β2‐agonists and three narcotics was established in this article. After the organic polymer‐based monolithic column was prepared by an in‐situ polymerization procedure, a systematic investigation of the pressure‐assisted CEC separation and ESI‐MS detection parameters was performed. Baseline separation of the studied analytes could be obtained using the solution containing 75% ACN v/v and 20 mmol/L ammonium acetate with pH 8.0 as running buffer, when applying separation voltage of 20 kV and assisted pressure of 5 bar. Under the optimized conditions, two β2‐agonists and three narcotics could be completely resolved and accurately determined within 15 min. Finally, the proposed method was successfully used for real urine samples detection.  相似文献   

11.
A systematic optimization of the HPLC separation of a mixture containing 11 pollutant phenols (PPs) using a Hypersil ODS (250 mm x 4.6 mm, 5 microm) column and UV-DAD detection has been carried out. The binary mobile phases used were obtained by mixing 50 mM phosphate (pH = 3.0) and methanol, ACN, or THF as organic modifiers. After selecting ACN as an organic modifier, the effects of pH and temperature on PPs separation were studied. A mobile phase of 50 mM acetate (pH = 5.0)-ACN (60:40 v/v) at 50 degrees C allowed the separation of 11 phenols but not to baseline in 17 min. To improve the performance of this separation, the following RP columns were tested: Luna C18 (2), Purospher C18, Synergi C12, Synergi Fusion C18, Gemini C18, Luna Cyano, Lichrospher C8, and Envirosep-PP (polymeric). In all the cases, the performance (analysis time, retention, selectivity, resolution, asymmetry factors, and efficiency) was evaluated. A further reoptimization of the mobile phase was carried out for all the columns by studying the ACN content and pH, with the aim of improving the above-mentioned separations and selecting the most suitable one for PPs analysis.  相似文献   

12.
In this work, the simultaneous separation of ten phenolic compounds (protocatechuic, p-coumaric, o-coumaric, vanillic, ferulic, caffeic, syringic acids, hydroxytyrosol, tyrosol and oleuropein) in extra virgin olive oils (EVOOs) by isocratic RP CEC is proposed. A CEC method was optimized in order to completely resolve all the analyzed compounds by studying several experimental parameters. The influence of the stationary phase type (C(18) and C(8) modified silica gel), buffer concentration and pH as well as the organic modifier content of the mobile phase on retention factors, selectivity and efficiency were evaluated in details. A capillary column packed with Cogent bidentate C(18) particles for 23 cm and a mobile phase composed by 100 mM ammonium formate buffer pH 3/H(2)O/ACN (5:65:30 v/v/v) allowed the baseline resolution of the compounds under study in less than 35 min setting the applied voltage and temperature at 22 kV and 20 degrees C, respectively. A study, evaluating the intra- and interday precision as well as LOD and LOQ and method linearity was developed in accordance with the analytical procedures for method validation. LODs were in the range of 0.015-2.5 microg/mL, while calibration curves showed a good linearity (r(2) >0.997). The CEC method was applied to the separation and determination of these compounds in EVOO samples after a suitable liquid-liquid extraction procedure. The mean recovery values of the studied compounds ranged between 87 and 99%.  相似文献   

13.
For Part II of our ongoing study, we present a strategy for stationary phase optimization for the capillary electrochromatographic (CEC) separation of the 12 methylated benzo[a]pyrene (MBAP) isomers. Utilizing the optimum mobile phase conditions from Part I of our study as a guide, seven commercially available stationary phases have been evaluated for their ability to separate highly hydrophobic MBAP isomers. Ranging in design from high-performance liquid chromatography (HPLC) to CEC application, each phase was slurry packed in house and tested for CEC suitability and performance. Several stationary phase parameters were investigated for their effects on MBAP separation including bonding type (monomeric or polymeric, % carbon loading, surface coverage), pore size, particle size, and type of alkyl substituent. In this manner, the present state of commercially available packings has been assessed in our laboratory. Utilizing the optimum polymeric C18-5 microm-100 A-PAH stationary phase, the effects of CEC packed bed length and capillary inside diameter (I.D.) were also evaluated. A 50 microm I.D. capillary, 25 cm packed bed length and 75% (v/v) acetonitrile, 12.5 mM Tris, pH 8.0, 20 degrees C at 30 kV, provided resolution of 11 out of 12 MBAP isomers thus showing the effectiveness of CEC for analysis of structurally similar methylated polyaromatic hydrocarbons.  相似文献   

14.
A method for the resolution of a peptides mixture including hepcidin‐25, an iron metabolism marker, was developed by CE‐ESI‐MS. Several strategies were tested to optimize peptide separation, such as the addition of cyclodextrins or organic solvents in the BGE or the use of coated capillaries. Best results in terms of resolution, symmetry and efficiency were obtained with a BGE made of 500 mM ammonium acetate pH 4.5/ACN 70:30 v/v. Using the methodology of experimental design, BGE concentration, sheath liquid composition and MS‐coupling parameters were then optimized in order to obtain the best signal intensity for hepcidin. Finally, a 225 mM BGE and a sheath liquid composed of isopropanol/water 80:20 v/v containing 0.5% v/v formic acid were selected as it constitutes the best compromise for selectivity, peak shape and sensitivity.  相似文献   

15.
The aim of this study is to develop and optimize a simple and reliable high-performance liquid chromatography (HPLC) method for the simultaneous determination of rifampicin (RIF), isoniazid (INH), and pyrazinamide (PZA) in a fixed-dose combination. The method is developed and optimized using an artificial neural network (ANN) for data modeling. Retention times under different experimental conditions (solvent, buffer type, and pH) and using four different column types (referred to as the input and testing data) are used to train, validate, and test the ANN model. The developed model is then used to maximize HPLC performance by optimizing separation. The sensitivity of the separation (retention time) to the changes in column type, concentration, and type of solvent and buffer in the mobile phase are investigated. Acetonitrile (ACN) as a solvent and tetrabutylammonium hydroxide (tBAH), used to adjust pH, have the greatest influence on the chromatographic separation of PZA and INH and are used for the final optimization. The best separation and reasonably short retention times are produced on the micro-bondapak C18, 4.6 x 250-mm column, 10 microm/125 A using ACN-tBAH (42.5:57.5, v/v) (0.0002M) as the mobile phase, and optimized at a final pH of 3.10.  相似文献   

16.
A method for the separation of twelve monomethyl-substituted benz[a]anthracene isomers using poly-(sodium undecylenic sulfate) (poly-SUS) surfactant by means of electrokinetic capillary chromatography (EKC) is described. Several parameters such as concentration of acetonitrile (ACN), pH, as well as applied voltage were studied to optimize the EKC separation. ACN at a concentration of 35% v/v, 12.5 mM phosphate-borate buffer, 30 kV with 0.5% w/v poly-SUS at a pH of 9.5 provided a resolution of a mixture of nine out of twelve methylbenz[a]anthracene (MBA) isomers in 50 min. The results of this study suggest that molecular length of MBA rather than length-to-breath ratio plays an important role in the elution order of some isomers.  相似文献   

17.
Ge L  Yong JW  Tan SN  Ong ES 《Electrophoresis》2006,27(11):2171-2181
The applicability of CZE in combination with MS and MS/MS methods for the simultaneous separation and determination of 12 cytokinins was investigated for the first time. Cytokinins were first completely separated by CZE within less than 20 min using a volatile buffer and then detected directly by MS or MS/MS. Satisfactory separation of the 12 cytokinin standards was achieved using a 25 mM ammonium formate/formic acid buffer (pH 3.4) and 3% ACN v/v with a separation voltage of 25 kV. On the basis of the resolution of the neighboring peaks, the various parameters for CZE-MS optimization, such as buffer pH value, concentration of buffer and organic modifier, applied voltage and sheath liquid, were evaluated systematically. MS/MS with multiple reaction monitoring detection was carried out to obtain sufficient selectivity and sensitivity. The combination of on-line sample stacking and CZE-MS/MS achieved a detection limit in the range of 0.05-0.18 microM for the 12 cytokinins at an S/N of 3. The optimized CZE-MS/MS method was simple, rapid, low cost, robust and highly selective. Furthermore, the developed method was successfully applied to screen for endogenous cytokinins in purified coconut water extract sample. Nine cytokinins were detected and quantified in coconut water after SPE.  相似文献   

18.
Enhanced chiral separation performance has been observed for ketoprofen enantiomers in capillary electrochromatography (CEC) with an open-tubular (OT) column prepared with a specific molecule imprinted polymer (MIP) on the innerwall of 50mum ID capillary. The column was prepared by in situ thermal polymerization inside the pretreated and silanized fused silica capillary. A specific diluted monomer mixture composed of S-ketoprofen, methacrylic acid (MAA, functional monomer), ethylene glycol dimethacrylate (EDMA, cross-linker), and 4-styrenesulfonic acid (4-SSA) dissolved in 9/1 (v/v) acetonitrile/2-propanol was used to fabricate the OT-MIP layer. 4-SSA was added to form a MIP layer capable of stable and strong electro-osmotic flow (EOF) over the pH range of this study securing CEC elution of ketoprofen having partial negative charge near the optimized pH. Various parameters such as buffer pH, organic modifier composition, salt concentration, and applied potential have been optimized for CEC chiral separation of ketoprofen enantiomers. Very good separation selectivity and efficiency were observed, thus the chromatographic resolution of ketoprofen enantiomers was as high as 10.5, and the number of theoretical plates of R-ketoprofen, 156,000/m (40,000/m for S-ketoprofen), which proves that the OT-MIP-CEC type approach is a promising strategy in MIP study.  相似文献   

19.
Extracts of Adinandra nitida leaves, known as Shiyacha in China, were analyzed by monolithic columns of capillary electrochromatography (CEC). To obtain good resolution within a short time, stepwise gradient elution of CEC was employed, and the effects of experimental parameters, such as the buffer, the gradient conditions, and the mode of injection were studied systematically. Under optimized conditions, analysis could be accomplished in 25 min on a monolithic rod of macroporous poly(butyl methacrylate-co-ethylene dimethacrylate). With two identified flavonoids, epicatechin and apigenin, as markers, a quality control method for Shiyacha and its relevant products was established. The calibration curves exhibited good linear behavior over the concentration range of two orders of magnitude. On combination with an on-line concentration technique, the detection limit of flavonoids could be decreased to 25 ng for apigenin.  相似文献   

20.
Microemulsion electrokinetic chromatography (MEEKC) coupled with a diode-array detector was developed for the simultaneous analysis of natural steroidal compounds, withanolides including withaferin A, withacnistin and iochromolide. Optimal resolution was obtained with a microemulsion consisting of 70 mM octane, 800 mM 1-butanol, 100 mM sodium dodecyl sulfate (SDS), and 10 mM phosphate-borate buffer (pH 7) using a fused-silica capillary at 25 kV and 40 degrees C. Since this technique is not compatible with mass spectrometry detection, a capillary electrochromatographic method was developed to separate the investigated withanolides. The effects of mobile phase composition and pH were systematically investigated. Complete separation was obtained with a capillary electrochromatography (CEC) Hypersil C18 bonded silica column (packed length, 25 cmx100 microm ID and 375 microm OD), packed with 3 microm particles. The mobile phase consisted of formic acid-ammonia, pH 8 / acetonitrile (40/60 v/v); the voltage was set at 25 kV and the temperature at 20 degrees C. Under these conditions, resolution of these closely related compounds, including the critical pair withacnistin and iochromolide, was achieved in less than 5 min. The separations by MEEKC and CEC were compared with that obtained by reversed-phase liquid chromatography and showed similar retention order, indicating the analogy of the retention mechanism of these techniques. To further improve specificity and sensitivity, the developed CEC method was interfaced with electrospray ionization mass spectrometry using a Teflon connection between the CEC column and a void fused-silica capillary. Finally, the described methods were applied to the qualitative analysis of withanolides in Iochroma gesnerioides plant extract.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号