首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For pharmacokinetic and toxicokinetic purpose a simple HPLC-UV method has been developed and validated for the estimation of DRF-4848, a novel COX-2 inhibitor in rat plasma. A liquid-liquid extraction was used to extract DRF-4848 and internal standard (IS, DRF-4367) from rat plasma. The analysis was performed on a C(18) column with UV detection at 285 nm. The isocratic mobile phase, 0.01 M potassium dihydrogen ortho phosphate (pH 3.2) and acetonitrile (50:50, v/v) was run at a flow rate of 1 mL/min. The retention times of DRF-4848 and IS were 6.8 and 11.2 min, respectively. Absolute recovery for analyte and IS was >80% from rat plasma. A linear response was observed over a concentration range 0.1-20 microg/mL. The lower limit of quantification (LLOQ) of DRF-4848 was 0.1 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.1, 0.3, 8.0 and 15.0 microg/mL, were in the range 1.74-8.70% relative standard deviation (RSD) and 0.75-8.43% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.29-116.51% of the nominal values. Analyte and IS were stable in the battery of stability studies viz., benchtop, autosampler, long-term and freeze/thaw cycles.  相似文献   

2.
In the present study, a rapid and simple high-performance liquid chromatographic (HPLC) assay for determination of puerarin in rat cortex was developed. The analysis was carried out on a Zorbax SB-C18 column with mobile phase acetonitrile-0.5% aqueous phosphoric acid (11:89, v/v). The detection was by UV at 252 nm. The calibration curve for puerarin was linear (r=0.9999) over the concentration range 0.516-206.250 microg/mL. The limit of detection was 0.206 microg/mL (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) was 0.516 microg/mL. Stability studies showed that puerarin was stable at temperatures of 4 degrees C in methanol for at least 30 days. The intra- and inter-day assays of puerarin from rat cortex were less than 2.5% at concentration range 0.516-206.250 microg/mL and good overall recoveries (97.4-101.7%) were found at same concentrations. The method was applied to determine the pharmacokinetic parameters and the time course of puerarin in rat cortex, following a single dosage of intravenous administration of flavonoids from Puerariae radix at 32 mg/kg of puerarin to male Wistar rats.  相似文献   

3.
A rapid and sensitive high-performance liquid chromatographic (HPLC) method is developed for the determination of tetramethylpyrazine phosphate, an antiplatelet aggregation agent, in 100 microL of dog plasma. Sample preparations are carried out by deproteinization with an internal standard (carbamazepine) solution in acetonitrile. An aliquot of the supernatant (20 microL) is directly injected into an HPLC apparatus with methanol-phosphate buffer (0.01M, pH 3.0) (62:38, v/v) as the mobile phase at a flow rate of 1.0 mL/min. Separation is performed with a C18 column at 30 degrees C. The peak is detected using a UV detector set at 279 nm. The capacity factors are 1.48 for tetramethylpyrazine phosphate and 2.09 for carbamazepine, with a total run time of 10 min. The calibration curve is linear in the 0.2-50-microg/mL range. The limit of detection is 0.05 microg/mL. Mean recoveries are 92.6-98.1%. The within- and between-day variation coefficients are less than 4.9% and 7.5%, respectively. The present method has been successfully used to provide pharmacokinetic data after oral administration of tetramethylpyrazine phosphate pulsincap capsules and immediate-release tablets to dogs.  相似文献   

4.
A validated reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the determination of bergenin in rat plasma. Bergenin in rat plasma was extracted with methanol, which also acted as a deproteinization agent. Chromatographic separation of bergenin was performed on a C(18) column, with a mobile phase of methanol-water (22:78, v/v) at a flow-rate of 0.8 mL/min and an operating temperature of 40 degrees C, and UV detection was set at 220 nm. The calibration curve was linear over the range 0.25-50 microg/mL (r = 0.9990) in rat plasma. The limit of quantification was 0.25 microg/mL using a plasma sample of 100 microL. The extraction recoveries were 83.40 +/- 6.02, 81.49 +/- 2.40 and 72.51 +/- 2.64% at concentrations of 0.5, 5 and 50 microg/mL, respectively. The intra-day and inter-day precision and accuracy were validated by relative standard deviation (RSD%) and relative error (RE%), which were in the ranges 3.74-9.91 and -1.6-8.0%. After intravenous administration to rats at the dose of 11.25 mg/kg, the plasma concentration-time curve of bergenin was best conformed to a two-compartment open model. The main pharmacokinetic parameters indicated that bergenin exhibited a wide distribution and moderate elimination velocity in rat.  相似文献   

5.
A reversed-phase high-performance liquid chromatographic (HPLC) assay for calycosin-7-O-beta-D-glucopyranoside in rat plasma and urine with solid-phase extraction (SPE) was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) at a flow rate of 1.0 mL/min. Detection was set at 280 nm. The limit of quantitation of calycosin-7-O-beta-D-glucopyranoside was 0.2 microg/mL in both plasma and urine. The standard curve was linear from 0.2 to 10.0 microg/mL in plasma, and 0.2 to 5.0 microg/mL in urine. Both intra- and inter-day precision of the calycosin-7-O-beta-d-glucopyranoside were determined and their RSD did not exceed 10%. The method was successfully applied to the analysis of samples obtained from a basic pharmacokinetic study, in which calycosin-7-O-beta-d-glucopyranoside was administered orally to rats.  相似文献   

6.
A fast and selective HPLC method for assaying amphotericin B in biological samples was developed and validated. The chromatographic separation was achieved in less than 12 min on a reverse-phase C(18) column using an acetonitrile-acetic acid-water (52:4.3:43.7, v/v/v) mixture as mobile phase. The flow rate was 1 mL/min and the effluent was monitored at 406 nm. A linear response over the concentration range 0.1-10.0 microg/mL was obtained. Intra-day and inter-day RSDs were below 5% for all the sample types. This new HPLC method was applied to assay amphotericin B in plasma and several tissue samples such as kidney, liver, spleen and bone marrow. Application of this method to pharmacokinetic studies in mice and dog is provided.  相似文献   

7.
A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and 365 nm for mangiferin in plasma and urine, respectively. The limit of quantitation (LOQ) of mangiferin was 0.6 microg/mL in plasma, and 0.48 microg/mL in urine. The standard curve was linear from 0.6 to 24 microg/mL in plasma, and 0.48 to 24 microg/mL in urine, both intra- and inter-day precision of the mangiferin were determined and their RSD did not exceed 10%. The method provides a technique for rapid analysis of mangiferin in rat plasma and urine, which can be used in pharmacokinetic studies.  相似文献   

8.
A simple and sensitive high-performance liquid chromatography (HPLC) method has been developed for the determination of chlorogenic acid (3-O-caffeoyl-D-quinic acid) in plasma and applied to its pharmacokinetic study in rabbits after administration of Flos Lonicerae extract. Plasma samples are extracted with methanol. HPLC analysis of the extracts is performed on a C(18) reversed-phase column using acetonitrile-0.2% phosphate buffer (11:89, v/v) as the mobile phase. The UV detector is set at 327 nm. The standard curves are linear in the range 0.0500-1.00 microg/mL (r = 0.9987). The mean extraction recovery of 85.1% is obtained for chlorogenic acid. The interday precision (relative standard deviation) ranges from 5.0% to 7.5%, and the intraday precision is better than 9.0%. The limit of quantitation is 0.0500 microg/mL. The plasma concentration of chlorogenic acid shows a C(max) of 0.839 +/- 0.35 microg/mL at 34.7 +/- 1.1 min and a second one of 0.367 +/- 0.16 microg/mL at 273.4 +/- 39.6 min.  相似文献   

9.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of rhein with 100 microL human plasma using celecoxib as an internal standard (IS). The API-4,000 Q-Trap LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of rhein and IS from human plasma with acetonitrile, which yielded consistent recoveries of 36.01 and 65.85% for rhein and IS, respectively. The total chromatographic run time was 5.0 min and the elution of rhein and IS occurred at approximately 1.60 and 3.96 min, respectively. The resolution of peaks was achieved with 0.01 m ammonium acetate (pH 6.0):acetonitrile:methanol (30:58:12, v/v) on an Inertsil ODS-3 column. The method was proved to be accurate and precise at a linearity range of 0.005-5.00 microg/mL with a correlation coefficient (r) of >or=0.995. The lower limit of quantitation was 0.005 microg/mL. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. Rhein was found to be stable in the battery of stability studies. The application of the assay to pre-clinical pharmacokinetic studies confirmed the utility of the assay to derive pharmacokinetic parameters.  相似文献   

10.
A technique involving rapid sampling of cephaloridine in rat blood was achieved using a combination of microdialysis and sensitive microbore liquid chromatography. A microdialysis probe was inserted into the jugular vein/right atrium of a Sprague-Dawley rat. Then after a real-time collection of the analyte by microdialysis, the dialysate was automatically injected into a liquid chromatographic system via an on-line injector. Following a 2 h stabilization period after the surgical procedure, cephaloridine (20 mg/kg, i.v.) was then administered via the femoral vein. Isocratic elution of cephaloridine was carried out with a mobile phase containing methanol-20 mM monosodium phosphate (25:75, v/v, pH 5.5), and the flow rate of the mobile phase was 0.05 mL/min within 10 min. Intra- and inter-assay accuracy and precision of the assay were each less than 10%. The in vivo recovery of the cephaloridine from the microdialysate was 49.7 +/- 8.0% and 42.4 +/- 8.4% for 0.5 and 1 microg/mL standards (n = 6), respectively. Based on the pharmacokinetic analysis, the elimination half-life was 32.2 +/- 8.6 min by cephaloridine administration (20 mg/kg, i.v., n = 6).  相似文献   

11.
A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

12.
A high-performance liquid chromatography method with fluorescence detection (HPLC-FLD) for the determination of levofloxacin in human plasma is described. Neutralized with phosphate buffer (pH 7.0), the sample (0.1 mL) was extracted with dichlormethane (1 mL). After voltex-mixing and centrifuged at 3000g for 6 min at 4 degrees C, the upper aqueous layer was aspirated using a micro vacuum pump and the organic layer was directly transferred to a clean test tube without pipetting. The organic solvent was evaporated and the residues were reconstituted with the mobile phase. Levofloxacin and terazosin (internal standard, IS) were chromatographically separated on a C(18) column with a mobile phase containing phosphate buffer (pH 3.0, 10 mm), acetonitrile and triethylamine (76:24:0.076, v/v/v) at a flow rate of 1 mL/min. The analytes were detected using fluorescence detection at an excitation and emission wavelength of 295 and 440 nm, respectively. The linear range of the calibration curves was 0.0521-5.213 microg/mL for levofloxacin with a lower limit of quantitation (0.0521 microg/mL). The retention times of levofloxacin and terazosin were 2.5 and 3.1 min, respectively. Within- and between-run precision was less than 12 and 11%, respectively. Accuracy ranged from -6.3 to 4.5%. The recovery ranged from 86 to 89% at the concentrations of 0.0521, 0.5213 and 5.213 microg/mL. The present HPLC-FLD method is sensitive, efficient and reliable. The method described herein has been successfully used for the pharmacokinetic and bioequivalence studies of a levofloxacin formulation product after oral administration to healthy Chinese volunteers.  相似文献   

13.
张荣  刘昌辉  王宁生  宓穗卿 《色谱》2008,26(1):80-83
建立了一种快速、高效的以睾酮作为探针药物评价细胞色素P450 3A4(CYP3A4)酶活性的高效液相色谱-紫外检测方法。采用的色谱柱为Phenomenex C18柱(4.6 mm×150 mm,5 μm),梯度洗脱,流速1.0 mL/min,紫外检测波长245 nm,柱温30 ℃。睾酮与大鼠肝微粒体温孵后,过已活化好的C18固相萃取小柱,收集甲醇洗脱液,于37 ℃水浴中通N2吹干,用50%甲醇复溶后进样分析测定。研究结果表明,6β-羟基睾酮的 保留时间为11.60 min,线性范围为0.5~32 μg/mL,最低检出质量浓度为0.02 μg/mL,提取率为88.41%~92.73%,方法的回收率为99.07%~101.30%;睾酮的保留时间为19.27 min,线性范围为0.5~40 μg/mL,最低检出质量浓度为0.01 μg/mL,提取率为89.59%~92.66%,方法的回收率为96.50%~98.03%。两者的日内、日间相对标准偏差均小于10%,温孵体系中的其他内源性物质不干扰测定。该方法快速、稳定、灵敏度高,适合体外睾酮及其代谢物6β-羟基睾酮的测定,可应用于体外CYP3A4酶活性的评价及酶动力学的研究。  相似文献   

14.
A simple HPLC technique for determining mitragynine levels in serum was developed. The separation system consisted of a C18 column heated to 35 degrees C, a methanol-water (80:20, v/v) mobile phase, a flow rate of 0.8 mL/min and detection in the ultraviolet at 225 nm. Mitragynine, with a retention time of 10.09 min, was well resolved from any interferences in human serum and the internal standard peak. The calibration curve was linear from 0.1 to 10 microg/mL (r = 0.9995). Extraction of mitragy-nine from alkalinized serum using diethyl ether gave a high recovery (>or=85%). The intra- and inter-day precisions of the method were 4.29-5.88%RSD and 7.06-8.45%RSD, respectively. The accuracy ranged from -9.54 to +0.67%DEV. The limit of detection was 0.03 microg/mL and the lower limit of quantification was 0.1 microg/mL. Mitragynine in the stock solution was stable during 30 days of storage at 4 degrees C. This method was successfully applied to determine the pharmacokinetic characteristics of mitragynine levels in the serum of rats after it was administered orally.  相似文献   

15.
Dimethyl benzoylphenyl urea (BPU) inhibited tubulin polymerization, caused microtubule depolymerization in vitro and demonstrated activity against solid tumors. BPU is being tested in phase I clinical trials. A rapid and specific method using LC/UV has been developed for quantitation of BPU in human heparin-containing plasma to perform pharmacokinetic and pharmacodynamic studies. BPU is extracted from plasma into acetonitrile:n-butyl-chloride using paclitaxel as the internal standard and separated on a Waters Symmetry C18 (3.9 x 150 mm, 5 microm) column with acetonitrile-water mobile phase (70:30, v/v) using isocratic flow at 1 mL/min for a run time of 5 min. Ultraviolet detection was utilized and performed at 225 nm for BPU and paclitaxel. The retention times were 1.9 min for paclitaxel and 4.1 min for BPU. Calibration curves were generated over the range of 0.01-10 microg/mL with coefficient of determination of > 0.99. The values for within-day and between-day precision were < or = 17.0% at the LLOQ and < or = 7.4% at the low, medium and high quality controls; accuracy was +/- 5.4%. Following administration of BPU 320 mg as a weekly oral dose to a patient with advanced solid tumor malignancies, the maximum plasma concentration was 2 micro g/mL and concentrations were quantifiable up to 168 h after administration. The lower limit of quantitation of 0.01 microg/mL allows for successful measurement of plasma concentrations in patients.  相似文献   

16.
An analytical method based on high-performance liquid chromatographic (HPLC) with ultraviolet (UV) detection was developed for determination of scopolin in rat plasma using aesculin as internal standard (IS). After protein precipitation of plasma sample with methanol, the supernatant was directly injected and analyzed. Chromatographic separation was achieved on a C18 column using methanol and distilled water (22:78, v/v) containing 0.2% (v/v) glacial acetic acid as mobile phase with a column temperature of 30 degrees C. The UV detector was set at 338 nm. The calibration curve was linear over the range of 0.105-13.125 microg/mL with a correlation coefficient of 0.9998. The retention times of aesculin and scopolin were 10.4 and 12.8 min, respectively. The recoveries for plasma samples of 0.105, 4.725 and 13.125 microg/mL were 91.08, 95.30 and 96.10%, respectively. The RSD of intra- and inter-day assay variations was less than 7.35%. The lower limit of detection was 0.03 microg/mL .This HPLC assay is a simple, sensitive and accurate and was successfully applied to the pharmacokinetic study of scopolin in rats.  相似文献   

17.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of rosuvastatin (RST), a novel, synthetic and potent HMG-CoA inhibitor in rat plasma. The assay procedure involved simple liquid-liquid extraction of RST and internal standard (IS, ketoprofen) from a small plasma volume directly into acetonitrile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). Mobile phase consisting of 0.05 m formic acid and acetonitrile (55:45, v/v) was used at a flow rate of 1.0 mL/min for the effective separation of RST and IS. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 240 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of RST and IS were 8.6 and 12.5 min, respectively. The standard curve for RST was linear (r2 > 0.999) in the concentration range 0.02-10 microg/mL. Absolute recoveries of RST and IS were 85-110 and >100%, respectively, from rat plasma. The lower limit of quantification (LLOQ) of RST was 0.02 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.02, 0.06, 1.6 and 8.0 microg/mL, were in the range 7.24-12.43% relative standard deviation (RSD) and 2.28-10.23% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.05-112.17% of the spiked nominal values. Both analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. RST was found to be stable for a period of 30 days on storage at -80 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.  相似文献   

18.
Li H  He J  Liu Q  Huo Z  Liang S  Liang Y  Ito Y 《Chromatographia》2011,73(1-2):171-175
A simple, selective and sensitive reversed-phase high performance liquid chromatography method for simultaneous analysis of hydrochlorothiazide and reserpine in human urine was developed and subjected to primary pharmacokinetic study. After a simple protein precipitation using methanol and extraction with ethyl acetate, the analytes were separated on an Elite C(18) column at a flow rate of 0.8 mL min(-1). The mobile phase was composed of acetonitrile (A) and 0.2% ammonium chloride solution (B) for a gradient elution starting at A:B at 30:70, v/v for 0~6 min, linearly raising the percent of A from 30% to 50% (6~9 min) and ending at 50:50, v/v (9~25 min). The standard curves were linear over the range of 0.05-20 μg mL(-1) for hydrochlorothiazide and 0.02-5.0 μg mL(-1) for reserpine, respectively (r > 0.999). The limit of detection (LOD) and the limit of quantification (LOQ) were 5.5 ng mL(-1) and 18.2 ng mL(-1) for hydrochlorothiazide, and 7.1 ng mL(-1) and 23.6 ng mL(-1) for reserpine, respectively. The recoveries for both analytes were above 89.0±1.35%. The intra-day and inter-day precision for hydrochlorothiazide were less than 1.91% and 1.38%, and those for reserpine were below 1.61% and 2.64%, respectively. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy, and it was employed successfully for the simultaneous determination of hydrochlorothiazide and reserpine in human urine samples.  相似文献   

19.
In this study a dynamic headspace method was developed to measure the carbon isotope values of dissolved chlorinated ethenes at microg/L concentrations. A gas chromatograph/combustion/isotope ratio mass spectrometer (GC/C/IRMS) was modified to include a headspace extraction system followed by a cryogenic trap. Extracting headspace from a 160 mL vial with 80 mL of aqueous solution and 40 g of NaCl for 8-12 min resulted in accurate and reproducible delta13C values for trichloroethene (TCE) and cis-1,2-dichloroethene (cDCE) at concentrations of 50-75 microg/L. Based on these results a conservative lower limit of quantitation of 38 microg/L can be calculated for these compounds. For more volatile compounds such as tetrachloroethene (PCE) and vinyl chloride (VC), field data analyzed using this method indicate a lower limit of quantitation in the tens of microg /L range.  相似文献   

20.
Simultaneous determination of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) in rat blood and brain microdialysates by high-performance liquid chromatography with fluorescence detection (HPLC-FL) was developed. Microdialysates were directly subjected to derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl). The DIB-derivatives of MDMA, MDA and the internal standard, 1-methyl-3-phenylpropylamine (MPPA), were isocratically separated on an ODS column using a mixture of 50 mm phosphate buffer (pH 7.0)-acetonitrile-methanol-2-propanol (50:45:5:2, v/v/v/v %) as an eluent at a flow rate of 1.5 mL/min. The calibration curves of MDA and MDMA spiked to blood and brain microdialysates were linear over the ranges 2.5-500 and 5.0-1000 ng/mL, respectively. The detection limits of MDA and MDMA were 1.2 and 4.2 for blood and 1.3 and 4.8 ng/mL for brain, respectively. Additionally, the intra- and the inter-assay precisions were lower than 5.6% for the blood and brain microdialysates (n = 4). The proposed method was successfully applied for the monitoring of MDMA and its metabolite MDA in rat blood and brain microdialysates, and the pharmacokinetic parameters of MDMA and MDA in the microdialysates after administration of MDMA (5 mg/kg, i.p.) with or without caffeine (20 mg/kg, i.p.) were evaluated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号