1.
Cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) is an excellent chiral selector for enantioseparation of a wide variety of chiral compounds. The monolithic chiral columns are becoming popular in liquid chromatography and capillary electrochromatography. In this work, we present the fast separation of chiral β-blockers on a CDMPC-modified zirconia monolithic column by capillary electrochromatography (CEC). The porous zirconia monolithic capillary column was prepared by using the sol-gel technology and then zirconia surface modified with CDMPC. The enantioseparations were performed in reversed-phase (RP) eluents of a phosphate solution (pH 4.4) modified with acetonitrile or alcohol. The enantioseparations of a set of eight chiral β-blockers were achieved in less than one minute. Influences of the applied voltage, column temperature, concentration of acetonitrile and the type of alcohol as the organic modifier in the mobile phase, and sample injection time on enantioseparation were investigated. CEC separations at the applied voltage of 10 kV and 15 °C in the ACN-modified mobile phase provided the best resolutions for the analytes studied. Run-to-run and day-to-day repeatabilities of the column in the RP-CEC separation were less than 1 and 2%, respectively.  相似文献   

2.
Wu R  Zou H  Fu H  Jin W  Ye M 《Electrophoresis》2002,23(9):1239-1245
The mixed mode of reversed phase (RP) and strong cation-exchange (SCX) capillary electrochromatography (CEC) based on a monolithic capillary column has been developed. The capillary monolithic column was prepared by in situ copolymerization of 2-(sulfooxy)ethyl methacrylate (SEMA) and ethylene dimethacrylate (EDMA) in the presence of porogens. The sulfate group provided by the monomer SEMA on the monolithic bed is used for the generation of the electroosmotic flow (EOF) from the anode to the cathode, but at the same time serves as a SCX stationary phase. A mixed-mode (RP/SCX) mechanism for separation of peptides was observed in the monolithic column, comprising hydrophobic and electrostatic interaction as well as electrophoretic migration at a low pH value of mobile phase. A column efficiency of more than 280,000 plates/m for the unretained compound has been obtained on the prepared monoliths. The relative standard deviations observed for t(0) and retention factors of peptides were about 0.32% and less than 0.71% for ten consecutive runs, respectively. Effects of mobile phase compositions on the EOF of the monolithic column and on the separation of peptides were investigated. The selectivity on separation of peptides in the monolithic capillary column could be easily manipulated by varying the mobile phase composition.  相似文献   

3.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

4.
硅胶电色谱分离机理的研究   总被引:1,自引:1,他引:0  
对硅胶电色谱柱的性能进行了考察,发现在水/有机溶剂流动相条件下,几乎不存在气泡问题,流动相的组成在有机溶剂浓度、电解质浓度、PH值等方面可以在较大范围变化,选用5种典型样品,对硅胶电色谱的分离机理进行了系统研究,发现有反相分离机理、正相吸附机理、离子交换机理以及电泳机理参与作用。同时考察了有机溶剂浓度、电解质浓度、PH等对分离的影响。此外,还首次提出了一种全新的电色谱模式-动态改性硅胶电色谱。  相似文献   

5.
A neutral, nonpolar monolithic capillary column was evaluated as a hydrophobic stationary phase in pressurized CEC system for neutral, acidic and basic solutes. The monolith was prepared by in situ copolymerization of octadecyl methacrylate and ethylene dimethacrylate in a binary porogenic solvent consisting of cyclohexanol/1,4‐butanediol. EOF in this hydrophobic monolithic column was poor; even the pH value of the mobile phase was high. Because of the absence of fixed charges, the monolithic capillary column was free of electrostatic interactions with charged solutes. Separations of neutral solutes were based on the hydrophobic mechanism with the pressure as the driving force. The acidic and basic solutes were separated under pressurized CEC mode with the pressure and electrophoretic mobility as the driving force. The separation selectivity of charged solutes were based on their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase, and no obvious peak tailing for basic analytes was observed. Effects of the mobile phase compositions on the retention of acidic compounds were also investigated. Under optimized conditions, high plate counts reaching 82 000 plates/m for neutral compounds, 134 000 plates/m for acid compounds and 150 000 plates/m for basic compounds were readily obtained.  相似文献   

6.
Li Y  Xiang R  Horváth C  Wilkins JA 《Electrophoresis》2004,25(4-5):545-553
A new kind of monolithic capillary column was prepared for capillary electrochromatography (CEC) with a positively charged polymer layer on the inner wall of a fused-silica capillary and a neutral monolithic packing as the bulk stationary phase. The fused-silica capillary was first silanized with 3-glycidoxypropyltrimethoxysilane (GPTMS). Polyethyleneimine (PEI) was then covalently bonded to the GPTMS coating to form an annular positively charged polymer layer for the generation of electroosmotic flow (EOF). A neutral bulk monolithic stationary phase was then prepared by in situ copolymerization of vinylbenzyl chloride (VBC) and ethylene glycol dimethacrylate in the presence of 1-propanol and formamide as porogens. Benzyl chloride functionalities on the monolith were subsequently hydrolyzed to benzyl alcohol groups. Effects of pH on the EOF mobility of the column were measured to monitor the completion of reactions. Using a column with this design, we expected general problems in CEC such as irreversible adsorption and electrostatic interaction between stationary phase and analytes to be reduced. A peptide mixture was successfully separated in counter-directional mode CEC. Comparison of peptide separations in isocratic monolithic CEC, gradient HPLC and capillary zone electrophoresis (CZE) indicated that the separation in CEC is governed by a dual mechanism that involves a complex interplay between selective chromatographic retention and differential electrophoretic migration.  相似文献   

7.
甲基丙烯酸基质的毛细管电色谱整体柱的制备与应用   总被引:1,自引:0,他引:1  
以甲基丙烯酸(MAA)为功能单体,同时又作电渗流改性剂, 乙二醇二甲基丙烯酸酯(EDMA)为交联剂,甲苯和异辛烷为致孔剂,Irgacure 1800为光引发剂,采用紫外光引发原位聚合反应制备出毛细管电色谱整体柱.对影响电渗流的因素如pH、乙腈含量及离子强度等进行了讨论.使用制备的整体柱在3种模式(加压电色谱、气压驱动和电色谱)下对7种中性物质(硫脲、苯、甲苯、乙苯、萘、联苯和菲)的混合物实现基线分离,同时还可实现酸性物质(邻羟基苯甲酸、苯甲酸、苯乳酸、扁桃酸)和碱性物质(苯胺、甲苯胺、乙酰基苯胺和N-甲基苯胺)的快速分离.  相似文献   

8.
Chen Z  Hobo T 《Electrophoresis》2001,22(15):3339-3346
A silica-based chiral monolithic column prepared by sol-gel process and chemical modification of chiral selector was used for enantioseparation of dansyl amino acids and hydroxy acids by capillary electrochromatography (CEC) and mu-high-performance liquid chromatography (mu-HPLC). L-Prolinamide was modified as a chiral selector. The chiral stationary phase (CSP), the chiral complex of Cu(II) with L-prolinamide, provides an anodic electroosmotic flow (EOF) in CEC. The EOF was found to be dependent on applied electric field strength, the pH, and the composition of mobile phases. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pore. D-Enantiomers migrated before L-enantiomers except for dansyl-(Dns)-DL-Ser. The separation efficiencies of up to 17600 (D) and 13,200 plates m(-1) (L) were achieved for the separation of DL-indole-3-lactic acid.  相似文献   

9.
A novel monolithic silica column with zwitterionic stationary phase was prepared by in-situ covalent attachment of phenylalanine to a 3-glycidoxypropyltriethoxysilane-modified silica monolith. Due to the zwitterionic nature of the resulting stationary phase, the density and sign of the net surface charge, and accordingly the direction and magnitude of electroosmotic flow in this column during capillary electrochromatography could be manipulated by adjusting the pH values of the mobile phase. CEC separations of various acidic and basic compounds were performed on the prepared column in anodic and weakly cathodic EOF modes, respectively. The peak tailing of basic compounds in CEC on a silica column could be alleviated at optimized buffer compositions. Besides the electrophoretic mechanism and weak hydrophobic interaction, weak cation- and anion-exchange interactions are also involved in the separations of acids and bases, respectively, on the zwitterionic column.  相似文献   

10.
分子印迹整体柱在高效液相色谱和电色谱手性分离中的应用   总被引:15,自引:0,他引:15  
在常规不锈钢色谱管中以甲基丙烯酸为功能单体,采用原位聚合法制备了(5S,11S)-特罗格尔碱(S-TB)的印迹整体柱。考察了流动相中添加不同量的醋酸和水对分离的影响,结合台阶梯度洗脱模式在S-TB整体柱上实现了对TB消旋体的快速分离。另外,以碱性单体2-二甲基乙基胺甲基丙烯酸酯(DAMA)为功能单体,在毛细管中采用原位聚合法制备了毛细管分子印迹整体柱,用于在毛细管电色谱(CEC)中对消旋体1,1′-联-2-萘酚(BNL)进行手性分离。结果表明,以AMA为功能单体可以制备其他酸性模板的分子印迹聚合物,从而扩大了分子印迹聚合物MIP)在CEC分离中的应用范围。  相似文献   

11.
A silica-bonded bovine serum albumin (BSA) chiral monolithic stationary phase for capillary electrochromatography(CEC) was introduced. An inorganic-organic hybrid monolithic column was firstly prepared by sol-gel chemistry with homogeneously distributed aminopropyl groups throughout the silica matrix. Then the chiral stationary phase was synthesized by the in situ covalent immobilization of BSA on the monolithic column activated with glutaraldehyde. The effects of pH value and concentration of phosphate buffer on the separation of D,L-tryptophan were investigated. The separation factor of D,L-tryptophan reached 3.37 on CEC mode.  相似文献   

12.
This work reports the preparation of monolithic zirconia chiral columns for separation of enantiomeric compounds by capillary electrochromatography (CEC). Using sol–gel technology, a porous monolith having interconnected globular-like structure with through-pores is synthesized in the capillary column as a first step in the synthesis of monolithic zirconia chiral capillary columns. In the second step, the surface of the monolith is modified by coating with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) as the chiral stationary phase to obtain a chiral column (CDMPCZM). The process of the preparation of the zirconia monolithic capillary column was investigated by varying the concentrations of the components of the sol solution including polyethylene glycol, water and acetic acid. CDMPCZM is mechanically stable and no bubble formation was detected with the applied current of up to 30 μA. The enantioseparation behavior of the CDMPCZM columns was investigated by separating a set of 10 representative chiral compounds by varying the applied voltage and pH and organic composition of the aqueous organic mobile phases.  相似文献   

13.
Fused-silica capillary columns (100 μm I.D.) englobing a porous monolithic stationary phase were prepared by in situ copolymerization of 2-ethylhexyl methacrylate, ethylene glycol dimethacrylate and 2-acrylamido-2-methylpropanesulfonic acid (AMPS) in the presence of a porogenic mixture containing 1-propanol, 1,4 butanediol and water. The influence of the monomers ratio and the porogen solvent composition as well as the content of AMPS in the polymerization mixture on column total porosity and efficiency was investigated to attain minimum HETP values for the reversed-phase capillary electrochromatography separation of bioflavonoids. For the most promising column, the van Deemter plots, in both μ-HPLC and CEC, were also evaluated. In CEC the reduced plate height was found almost constant (1.6–2.0) within the range of linear mobile phase velocity between 0.2–2.0 mm s−1. The chemical and mechanical stabilities of the monolithic column over a wide range of buffer pH (2-10) and time were satisfactory. Furthermore, the effects of mobile phase parameters, such as buffer concentration and organic modifier content, on the electroosmotic flow were studied systematically. CEC separations of standard mixtures of polyphenols, including flavonols, flavanones and flavanones-7-O-glycosides, were accomplished in less than 8 min. The CEC separation of the major flavanone glycoside constituents in the extract from a freshly squeezed grapefruit juice was also reported.  相似文献   

14.
The current popularity of capillary electrochromatography (CEC) has led to an increasing number of studies on the development and evaluation of enantioselective CEC systems. These studies clearly demonstrate that the most prominent advantage of electrically driven separation methods, the vastly increased column efficiency as compared to pressure-driven chromatography, can also be experimentally achieved for the separations of enantiomers. In analogy to high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE), several approaches have been used. The addition of a chiral selector to the mobile phase is the simplest method. Less erroneous and more elegant approaches are those that use open-tubular, conventional packed, and monolithic columns containing chiral stationary phases that stereoselectively interact with enantiomers. This review evaluates the new techniques and compares them to enantioselective HPLC and CE. Further, it describes the various concepts of enantioselective CEC and focuses on the current ‘state-of-the-art' column technology.  相似文献   

15.
王佳静  陈昭  吴玉田  范国荣 《色谱》2010,28(3):240-246
以甲基丙烯酸酯整体柱为分离柱,建立了一种快速分离、分析白芷药材提取物中的主要活性成分欧前胡素(imperatorin)、异欧前胡素(isoimperatorin)、珊瑚菜内酯(phelloptorin)和发卡二醇(falcarindiol)的毛细管电色谱(CEC)方法。在整体柱制备实验中对三元致孔剂组成成分的比例进行了系统的考察。在分离实验中对流动相的组成(包括有机相组成、缓冲液浓度和缓冲液的pH值)进行了优化。最终的优化条件为: 流动相为乙腈-20 mmol/L NaH2PO4(pH 4.95)(50:50, v/v),分离电压为-25 kV。结果表明,所制备的甲基丙烯酸酯毛细管整体柱具有良好的渗透性和重现性;4种分析物的标准曲线线性关系良好(r2>0.997),检出限均小于0.34 mg/L,加样回收率为95.18%~98.44%。该方法快速、简便、可靠。应用该方法对18个不同产地的白芷样品进行了测定,并对其药材质量进行了评价。  相似文献   

16.
Xie C  Hu J  Xiao H  Su X  Dong J  Tian R  He Z  Zou H 《Electrophoresis》2005,26(4-5):790-797
A silica-based monolithic capillary column was prepared via a sol-gel process. The continuous skeleton and large through-pore structure were characterized by scanning electron microscopy (SEM). The native silica monolith has been successfully employed in the electrochromatographic separation of beta-blockers and alkaloids extracted from traditional Chinese medicines (TCMs). Column efficiencies greater than 250 000 plates/m for capillary electrochromatography (CEC) separation of basic compounds were obtained. It was observed that retention of basic pharmaceuticals on the silica monolith was mainly contributed by a cation-exchange mechanism. Other retention mechanisms including reversed-phase and normal-phase mechanisms and electrophoresis of basic compounds also played a role in separation. A comparison of the differences between CEC and capillary zone electrophoresis (CZE) separation was also discussed.  相似文献   

17.
Dong X  Wu R  Dong J  Wu M  Zhu Y  Zou H 《Electrophoresis》2008,29(4):919-927
A hydrophilic chiral capillary monolithic column for enantiomer separation in CEC was prepared by coating cellulose tris(3,5-dimethylphenyl-carbamate) (CDMPC) on porous hydrophilic poly(acrylamide-co-N,N'-methylene-bisacrylamide) (poly(AA-co-MBA)) monolithic matrix with confine of a fused-silica capillary. The coating conditions were optimized to obtain a stable and reproducible chiral stationary phase for CEC. The effect of organic modifier of ACN in aqueous mobile phase for the enantiomer separation by CEC was investigated, and the significant influence of ACN on the enantioresolution and electrochromatographic retention was observed. Twelve pairs of enantiomers including acidic, neutral, and basic analytes were tested and nine pairs of them were baseline-enantioresolved with acidic and basic aqueous mobile phases. A good within-column repeatability in retention time (RSD = 2.4%) and resolution (RSD = 3.2%) was obtained by consecutive injections of a neutral compound, benzoin, on a prepared chiral monolithic column, while the between-column repeatability in retention time (RSD = 6.4%) and resolution (RSD = 9.6%) was observed by column-to-column examination. The prepared monolithic stationary phase showed good stability in either acidic or basic mobile phase.  相似文献   

18.
Capillary Electrochromatography (CEC) offers a rapid, economical, and efficient means for resolving nonionic compounds in the reversed phase mode on octadecylsilane (ODS) columns. A CEC optimization on a Hypersil ODS capillary column was employed to identify a suitable mobile phase for the pressure-driven (reversed phase ODS) separation of the anti-inflammatory 2-phenylmethyl-1-naphthol (DUP 654), and its related substances. The proportions of mobile phase modifiers methanol, acetonitrile, and water as well as pH were employed as variables in a stacked mixture design. Comparable response surface profiles were obtained for the CEC separations at pH 4 and pH 8. However, subtle differences were evident in the quality of separations obtained in the liquid chromatographic (LC) mode when using a specially-prepared column packed with exactly the same stationary phase as used in the CEC experiments. A mapping of the response surface for separations on a commercially available Hypersil ODS LC column revealed obvious differences. The differences indicate that the transfer of ODS based separation methods between CEC and LC involves more than simply transferring the conditions from one mode to the other.  相似文献   

19.
Dong X  Dong J  Ou J  Zhu Y  Zou H 《Electrophoresis》2006,27(12):2518-2525
A polymer-based neutral monolithic capillary column was prepared by radical polymerization of glycidyl methacrylate and ethylene dimethacrylate in a 100 mum id fused-silica capillary, and the prepared monolithic column was subsequently modified based on a ring opening reaction of epoxide groups with 1 M lysine in solution (pH 8.0) at 75 degrees C for 10 h to produce a lysine chemically bonded stationary phases in capillary column. The ring opening reaction conditions were optimized so that the column could generate substantial EOF. Due to the zwitterionic functional groups of the lysine covalently bonded on the polymer monolithic rod, the prepared column can generate cathodic and anodic EOF by varying the pH values of running buffer during CEC separation. EOF reached the maximum of -2.0 x 10(-8) m2v(-1)s(-1) and 2.6 x 10(-8) m2v(-1)s(-1) with pH of the running buffer of 2.25 and 10, respectively. As a consequence, neutral compounds, ionic solutes such as phenols, aromatic acids, anilines, and basic pharmaceuticals were all successfully separated on the column by CEC. Hydrophobic interaction is responsible for separation of neutral analytes. In addition, the electrostatic and hydrophobic interaction and the electrophoretic migration play a significant role in separation of the ionic or ionizable analytes.  相似文献   

20.
The capillary electrochromatographic (CEC) analysis of basic compounds on octadecyl-silica stationary phases (Hypersil ODS and Spherisorb ODS I) was studied. A basic drug (fluvoxamine) and one of its possible impurities were used as test compounds. With an eluent of acetonitrile-phosphate buffer (pH 7.0), the compounds could be baseline-separated; however, broad and tailing peaks were obtained. To minimise detrimental interactions with residual silanol groups, the pH of the mobile phase was lowered to 2.5, but the plate numbers were still quite low (<2.6x10(4) plates/m). Addition of a masking agent (hexylamine or triethylamine) to the mobile phase resulted in much better peak efficiencies (ca. 1x10(5) plates/m). Therefore, the influence of the amine concentration and pH of the mobile phase on the CEC performance (peak width, peak tailing, electroosmotic flow, selectivity) was investigated in detail. Highest efficiencies (2.8x10(5) plates/m) could be obtained with the Spherisorb column, while the Hypersil column offered a better selectivity. Furthermore, the results show that the residual silanol groups are (at least partly) responsible for the separation of the basic compounds and that the amount of injected sample has an unusually large effect on the peak efficiency. The usefulness of the system for impurity profiling was demonstrated with a mixture containing fluvoxamine and its stereoisomer (a possible impurity) at the 0.1% level. The general effectiveness of amine additives in CEC was illustrated by the separation of a mixture of five structurally different basic drugs yielding plate numbers in the 1x10(5)-3x10(5) plates/m range. Comparison with capillary electrophoretic analysis revealed a unique selectivity of the CEC system which is based on both electrophoretic mobility and chromatographic partitioning.  相似文献   