首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel, simple, and rapid reversed‐phase vortex‐assisted liquid–liquid microextraction coupled with high‐performance liquid chromatography has been introduced for the extraction, clean‐up, and preconcentration of amygdalin in oil and kernel samples. In this technique, deionized water was used as the extracting solvent. Unlike the reversed‐phase dispersive liquid–liquid microextraction, dispersive solvent was eliminated in the proposed method. Various parameters that affected the extraction efficiency, such as extracting solvent volume and its pH, vortex, and centrifuging times were evaluated and optimized. The calibration curve shows good linearity (r2 = 0.9955) and precision (RSD < 5.2%) in the range of 0.07–20 μg/mL. The limit of detection and limit of quantitation were 0.02 and 0.07 μg/mL, respectively. The recoveries were in the range of 96.0–102.0% with relative standard deviation values ranging from 4.0 to 5.1%. Unlike the conventional extraction methods for plant extracts, no evaporative and re‐solubilizing operations were needed in the proposed technique.  相似文献   

2.
Notoginsenoside Fc, a protopanaxadiol‐type saponin, shows multi‐pharmacological activities. Chemical stability evaluation plays a crucial role in drug development. In this study, the forced degradation behavior of Notoginsenoside Fc was investigated under hydrolytic and oxidative conditions. A specific ultra high performance liquid chromatography with quadrupole time‐of‐flight mass spectrometry was developed for the separation, identification, and characterization of the degradation products of Notoginsenoside Fc. Fifty potential degradation products were formed via deglycosylation, dehydration, hydration, isomerization, side‐chain cleaving, oxidation, and superoxidation. Notoginsenoside Fc was subjected to different pH solutions, temperatures, and time periods to assess its stability. A sensitive ultra high performance liquid chromatography‐tandem mass spectrometry was developed for the quantification of Notoginsenoside Fc, notoginsenoside ST‐4, notoginsenoside Ft1, and relative quantification of notoginsenoside Ft2, 20(R)‐notoginsenoside Ft2, notoginsenoside SFt3, and notoginsenoside SFt4. The assay was linear over the concentration range (R> 0.997) with the lowest limit of quantification of 0.02 μg/mL for Notoginsenoside Fc, Notoginsenoside ST‐4, and Notoginsenoside Ft1. The intra‐day precision, inter‐day precision, and accuracy of the three analytes were within accepted levels. The degradation kinetics of Notoginsenoside Fc in pH 1 and 3 solutions fits to first‐ and second‐order kinetics, respectively. The degradation of Notoginsenoside Fc is pH‐, temperature‐, and time‐dependent.  相似文献   

3.
A new liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of trifolirhizin, (–)‐maackiain, (–)‐sophoranone, and 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran from Sophora tonkinensis in rat plasma using chlorpropamide as an internal standard. Plasma samples (50 μL) were prepared using a simple deproteinization procedure with 150 μL of acetonitrile containing 100 ng/mL of chlorpropamide. Chromatographic separation was carried out on an Acclaim RSLC120 C18 column (2.1 × 100 mm, 2.2 μm) using a gradient elution consisting of 7.5 mM ammonium acetate and acetonitrile containing 0.1% formic acid (0.4 mL/min flow rate, 7.0 min total run time). The detection and quantitation of all analytes were performed in selected reaction monitoring mode under both positive and negative electrospray ionization. This assay was linear over concentration ranges of 50–5000 ng/mL (trifolirhizin), 25–2500 ng/mL ((–)‐maackiain), 5–250 ng/mL ((–)‐sophoranone), and 1–250 ng/mL 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran) with a lower limit of quantification of 50, 25, 5, and 1 ng/mL for trifolirhizin, (–)‐maackiain, (–)‐sophoranone, and 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran, respectively. All the validation data, including the specificity, precision, accuracy, recovery, and stability conformed to the acceptance requirements. The results indicated that the developed method is sufficiently reliable for the pharmacokinetic study of the analytes following oral administration of Sophora tonkinensis extract in rats.  相似文献   

4.
A novel and reliable method for determination of five triazole fungicide residues (triadimenol, tebuconazole, diniconazole, flutriafol, and hexaconazol) in traditional Chinese medicine samples was developed using dispersive solid‐phase extraction combined with ultrasound‐assisted dispersive liquid–liquid microextraction before ultra‐high performance liquid chromatography with tandem mass spectrometry. The clean up of the extract was conducted using dispersive solid‐phase extraction by directly adding sorbents into the extraction solution, followed by shaking and centrifugation. After that, a mixture of 400 μL trichloromethane (extraction solvent) and 0.5 mL of the above supernatant was injected rapidly into water for the dispersive liquid–liquid microextraction procedure. The factors affecting the extraction efficiency were optimized. Under the optimum conditions, the calibration curves showed good linearity in the range of 2.0–400 (tebuconazole, diniconazole, and hexaconazole) and 4.0–800 ng/g (triadimenol and flutriafol) with the regression coefficients higher than 0.9958. The limit of detection and limit of quantification for the present method were 0.5–1.1 and 1.8–4.0 ng/g, respectively. The recoveries of the target analytes ranged from 80.2 to 103.2%. The proposed method has been successfully applied to the analysis of five triazole fungicides in traditional Chinese medicine samples, and satisfactory results were obtained.  相似文献   

5.
A method based on ultrasound‐assisted liquid–liquid extraction and high‐performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound‐assisted liquid–liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R2 > 0.9962 over a concentration range of 1–100 μg/L) and repeatability (relative standard deviation < 6.3%). Furthermore, the detection limit (S/N = 3) of the method were ranged from 0.02 to 0.13 μg/L and the quantification limit (S/N = 10) ranged from 0.07 to 0.35 μg/L. Finally, the proposed method was applied to spiked samples and satisfactory results were achieved. These results indicate that ultrasound‐assisted liquid–liquid extraction coupled with high‐performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.  相似文献   

6.
Sun protection is an important part of our lives. UV filters are widely used to absorb solar radiation in sunscreens. However, excess UV filters constitute persistent groups of organic micropollutants present in the environment. An environmentally friendly ionic‐liquid‐based up‐and‐down shaker‐assisted dispersive liquid?liquid microextraction device combined with ultra‐performance liquid chromatography coupled with photodiode‐array detection has been developed to preconcentrate three UV filters (benzophenone, 2‐hydroxy‐4‐methoxybenzophenone, 2,2′‐dihydroxy‐4‐methoxybenzophenone) from field water samples. In this method, the optimal conditions for the proposed extraction method were: 40 μL [C8MIM][PF6] as extraction solvent and 200 μL methanol as disperser solvent were used to extract the UV filters. After up‐and‐down shaking for 3 min, the aqueous solution was centrifuged at 5000 rpm speed, then using microtube to collect the settled extraction solvent and using ultra‐performance liquid chromatography for further analysis. Quantification results indicated that the linear range was 2–1000 ng/mL. The LOD of this method was in the range 0.2–1.3 ng/mL with r2 ≥ 0.9993. The relative recovery in studies of different types of field water samples was in the range 92–120%, and the RSD was 2.3–7.1%. The proposed method was also applied to the analysis of field samples.  相似文献   

7.
Shuanghuanlian oral liquid, a traditional Chinese medicine preparation, is a mixture of three herbs (Flos Lonicerae, Radix Scutellariae and Fructus Forsythiae). In this study, the quantitative analysis of three main active compounds, chlorogenic acid, forsythin and baicalin in samples from different manufacturers was performed rapidly by high‐performance liquid chromatography coupled with photodiode array detection followed by Contour Projection coupled to stepwise regression treatment of the obtained three‐dimensional spectra in which the partial overlap between adjacent target components existed. The method was validated for linearity (R>0.9940), precision (RSD<1.25%), recovery (92.20–102.50%), limit of detection (0.01–0.02 μg/mL) and limit of quantification (0.03–0.07 μg/mL). The results indicated that the combination of the three‐dimensional spectra of traditional Chinese medicine and Contour Projection‐stepwise regression offered an accurate, simple, low‐cost and eco‐friendly way for the rapid quantitative analysis of Shuanghuanlian oral liquid samples.  相似文献   

8.
PCK3145 is a synthetic peptide, derived from the Prostate Secreted Protein 94 (PSP94), with promising in vitro and animal in vivo results in prostate cancer. The aim of the present study was to develop and validate a fast and robust ultra‐high‐performance liquid chromatography with ultraviolet detection for the determination of PCK3145 in human plasma which would be suitable for the assessment of PCK3145 stability to proteolytic degradation. Following protein precipitation, chromatographic separation was carried out on an Aeris Peptide C18 column with mobile phase consisting of acetonitrile–water at a flow‐rate of 0.50 mL/min. The calibration curve was linear over the range 0.50–20.00 μg/mL. Intra‐ and inter‐day percentage relative standard deviation and relative error were ≤10%. The limit of detection and the lower limit of quantification were 0.15 and 0.50 μg/mL, respectively. Recovery of PCK3145 from human plasma was ≥96%. The peptide presented high stability in whole blood and in human plasma (>98% intact peptide after 24 h incubation at 37°C in human plasma), which represents a distinctive advantage in the therapeutic use of the compound. This is the first validated UHPLC method for the determination of PCK3145 reported, and it was successfully applied in the study of the proteolytic stability of PCK3145 in human plasma ex vivo. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
A high‐performance liquid chromatography (HPLC) method for assay of d ‐Lys6–GnRH contained in a microemulsion‐type formulation is described. The peptide is extracted from the microemulsion matrix and quantified using a two‐step gradient method. Separation from microemulsion compounds and potential peptide oxidation products was achieved on a Jupiter C18 column at 40°C, using a gradient of 10–35% CH3CN for peptide elution. The correlation of peak intensity measured at 220 nm and peptide concentration was linear over the range 2.5–60 µg/mL with a correlation coefficient of 0.9997 and a y‐intercept not significantly different from zero (p > 0.05). Intraday and interday variability of the assay was less than 5% for multiple injections of samples containing 7.5, 30 and 60 µg/mL. The lower limit of quantitation was calculated to be 0.38 µg/mL, and the lower limit of detection was 0.13 µg/mL. The assay was applied to samples that were stressed under physiological conditions (37°C, pH 7.4) over 4 days. Three degradation peaks were well resolved from the parent peptide, demonstrating the selectivity of the assay. Off‐line MALDI TOF mass spectrometry was applied to identify these degradation species as oxidation products of the peptide. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

11.
New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute‐filter‐and‐shoot protocol utilizing propan‐2‐ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes.  相似文献   

12.
A high‐throughput and environmentally friendly method based on 96‐well plate thin‐film microextraction was established to determine 14 fungicides in grapes and grape juice using liquid chromatography–tandem mass spectrometry. The thin‐film microextraction optimized method consisted of 60 min of extraction at pH 6.0 with the addition of sodium chloride (2–5%). Acetonitrile/water in the ratio of 8:2 was used for desorption analytes for 60 min. Evaluation of different extractive phases showed that polyacrylonitrile–polystyrene–divinylbenzene was the optimum coating. The linearity of the method was good in the range of 0.01–0.5 μg/mL for 14 fungicides with determination coefficients (R2) from 0.990 to 0.999, which indicated good linearity for both the grape juice and grape matrixes. The limit of detection was in the range of 0.002–0.01 μg/mL. The limit of quantitation was in the range of 0.01 mg/kg according to the minimum fortified level. The average absolute recoveries of the 14 fungicides ranged from 75.0 to 118.3%. The intraday relative standard deviation (n = 4) and interday relative standard deviation (n = 4) were 5.6–13.0% and 1.6–6.4%, respectively. This study showed that this method can be used for analyzing 96 samples in parallel, and the sample preparation time was approximately 2.0 min per sample. In addition, this approach offers a green and low‐cost sample pretreatment technique for future analyses.  相似文献   

13.
Kang‐Ai injection, which is composed of Astragali Radix, Ginseng Radix et Rhizoma, and kushenin, is extensively used in China as an adjuvant therapy for many types of cancer and chronic hepatitis B. In the present study, 47 herbal compounds (11 alkaloids, 8 astragalosides, and 28 ginsenosides), were detected in Kang‐Ai injection by ultra‐high‐performance liquid chromatography coupled to quadrupole time‐of‐flight tandem mass spectrometry, of which 31 were identified using authentic standards. Additionally, a practical ultra‐high‐performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry method was employed for simultaneous quantitative detection (31 available compounds), and relative quantitative detection (16 unavailable compounds) within 10 min. The limit of detection and limit of quantification was 0.11‐2.22 and 0.53‐11.08 ng/mL, respectively. Altogether, content levels of each compound ranged from 0.03 to 9835.57 μg/mL. Furthermore, chemometric analysis indicated oxymatrine, astragaloside IV, ginsenosides Rg1 and Re, and matrine had the greatest effect on concentration fluctuation. Therefore, we suggested these five compounds should be monitored during the manufacturing process. This method can be applied to provide crucial chemical profiles and quality assessments for Kang‐Ai injection, guaranteeing the safety, effectiveness, and controllability of the drug in clinics.  相似文献   

14.
In Asian countries, sesame seed oil unsaponified matter is used as a natural food additive due to its associated antioxidant effects. We determined and purified the primary lignans sesamin and sesamolin in sesame seed oil unsaponified matter using reversed‐phase liquid chromatography coupled with photodiode array and tandem mass spectrometry and high‐speed countercurrent chromatography. Calibration curves showed good correlation coefficients (r2 > 0.999, range 0.08 and/or 0.15 to 5 μg/mL) with a limit of detection (at 290 nm) of 0.02 μg/mL for sesamin and 0.04 μg/mL for sesamolin. Sesame seed oil unsaponified matter contained 2.82% sesamin and 2.54% sesamolin, respectively. Direct qualitative analysis of sesamin and sesamolin was achieved using quadrupole mass spectrometry with positive‐mode electrospray ionization. Pure (>99%) sesamin and sesamolin standards were obtained using high‐speed countercurrent chromatographic purification (hexane/ethyl acetate/methanol/water; 7:3:7:3). An effective method for determining and purifying sesamin and sesamolin from sesame seed oil unsaponified matter was developed by combining these separation techniques for standardized food additives.  相似文献   

15.
A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid–liquid microextraction based on the solidification of floating organic drops and determined by high‐performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket–Burman design and Box–Behnken design. The optimized values were: 58 μL of 1‐decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high‐performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0–1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2–0.4 and 0.1–0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples.  相似文献   

16.
Ultra‐performance convergence chromatography, which integrates the advantages of supercritical fluid chromatography and ultra high performance liquid chromatography technologies, is an environmentally friendly analytical method that uses dramatically reduced amounts of organic solvents. An ultra‐performance convergence chromatography method was developed and validated for the quantification of decursinol angelate and decursin in Angelica gigas using a CSH Fluoro‐Phenyl column (2.1 mm × 150 mm, 1.7 μm) with a run time of 4 min. The method had an improved resolution and a shorter analysis time in comparison to the conventional high‐performance liquid chromatography method. This method was validated in terms of linearity, precision, and accuracy. The limits of detection were 0.005 and 0.004 μg/mL for decursinol angelate and decursin, respectively, while the limits of quantitation were 0.014 and 0.012 μg/mL, respectively. The two components showed good regression (correlation coefficient (r2) > 0.999), excellent precision (RSD < 2.28%), and acceptable recoveries (99.75–102.62%). The proposed method can be used to efficiently separate, characterize, and quantify decursinol angelate and decursin in Angelica gigas and its related medicinal materials or preparations, with the advantages of a shorter analysis time, greater sensitivity, and better environmental compatibility.  相似文献   

17.
A novel stability‐indicating reversed phase ultra‐high performance liquid chromatography (UPLC) coupled photodiode array gradient method was developed for determination of the nifedipine and related compounds. Furthermore, based on the chromatographic conditions and forced degradation studies performed through the development of the related substances method a UPLC isocratic method was validated for the determination of the assay of this active substance. An Acquity Shield RP18 (50 × 3.0 mm 1.7 µm) column was used for separation of nifedipine and its five potential impurities within 11 min, which is 5‐fold less than the official method. A mobile phase consisting of 10 mm ammonium formate (pH 4.5) and methanol, delivered at a flow rate 0.5 mL/min, was employed to achieve a minimum resolution of 2.0 for all consecutive pairs of compounds. The precision value expressed as percentage relative standard deviation for method repeatability and reproducibility was <5.0%. The recoveries for all the related compounds were in the range of 99–105.0%. Linearity was found to be acceptable over the concentration range of 0.25–1.5 µg/mL for nifedipine and its impurities. The limit of quantification for nifedipine was 0.05 µg/mL, which is much less than the European Pharmacopoeia method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Ultra‐high‐pressure extraction combined with high‐speed counter‐current chromatography was employed to extract and purify wedelolactone and isodemethylwedelolactone from Ecliptae Herba. The operating conditions of ultra‐high‐pressure extraction were optimized using an orthogonal experimental design. The optimal conditions were 80% aqueous methanol solvent, 200 MPa pressure, 3 min extraction time and 1:20 (g/mL) solid–liquid ratio for extraction of wedelolactone and isodemethylwedelolactone. After extraction by ultra‐high pressure, the extraction solution was concentrated and subsequently extracted with ethyl acetate; a total of 2.1 g of crude sample was obtained from 100 g of Ecliptae Herba. A two‐phase solvent system composed of petroleum ether–ethyl acetate–methanol–water (3:7:5:5, v/v) was used for high‐speed counter‐current chromatography separation, by which 23.5 mg wedelolactone, 6.8 mg isodemethylwedelolactone and 5.5 mg luteolin with purities >95% were purified from 300 mg crude sample in a one‐step separation. This research demonstrated that ultra‐high‐pressure extraction combined with high‐speed counter‐current chromatography was an efficient technique for the extraction and purification of coumestans from plant material.  相似文献   

19.
An ultra‐high‐performance liquid chromatography–tandem mass spectrometry (UHPLC‐MS/MS) method for the analysis of cefazolin and cefalothin in human plasma (total and unbound), urine and peritoneal dialysate has been developed and validated. Total plasma concentrations are measured following protein precipitation and are suitable for the concentration range of 1–500 µg/mL. Unbound concentrations are measured from ultra‐filtered plasma acquired using Centrifree® devices and are suitable for the concentration range of 0.1–500 µg/mL for cefazolin and 1–500 µg/mL for cefalothin. The urine method is suitable for a concentration range of 0.1–20 mg/mL for cefazolin and 0.2–20 mg/mL for cefalothin. Peritoneal dialysate concentrations are measured using direct injection, and are suitable for the concentration range of 0.2–100 µg/mL for both cefazolin and cefalothin. The cefazolin and cefalothin plasma (total and unbound), urine and peritoneal dialysate results are reported for recovery, inter‐assay precision and accuracy, and the lower limit of quantification, linearity, stability and matrix effects, with all results meeting acceptance criteria. The method was used successfully in a pilot pharmacokinetic study with patients with peritoneal dialysis‐associated peritonitis, receiving either intraperitoneal cefazolin or cefalothin. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
Although aflatoxins contamination in feedstuff is a well‐known problem, and hence these residues are controlled in poultry products, there is scarce information regarding the presence of these toxic substances in aquaculture fish, facilities that use several feedstuff for fish breeding. A simple, rapid, and sensitive method has been therefore developed for aflatoxins (B1, B2, G1, and G2) assessment in aquaculture products by combining ultrasound probe‐assisted extraction and vortex‐assisted liquid–liquid microextraction as a sample pretreatment, and high‐performance liquid chromatography‐tandem mass spectrometry as a separation/detection system. Aflatoxins were extracted from fish flesh/liver with a 60:40 acetonitrile/aqueous phosphate buffer (pH 7.0) mixture before preconcentration and clean‐up by vortex‐assisted liquid–liquid microextraction under the following optimized conditions: 5.0 mL of fish extract at pH 7.0 and NaCl at 0.5% (w/v), 400 μL of chloroform as extracting solvent, and vortex shaking at 2000 rpm for 1 min. The proposed method is shown to be precise and accurate, and the limit of quantitations (from 0.20 to 1.10 μg kg?1) were lower than the value established by the European Commission Regulation for aflatoxins in foodstuff. Results have shown that fish flesh is free of aflatoxins, but aflatoxins B2 and G1 were quantified in fish liver.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号