首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
In this study, a simple and rapid extraction method based on the application of polypyrrole‐coated Fe3O4 nanoparticles as a magnetic solid‐phase extraction sorbent was successfully developed for the extraction and preconcentration of trace amounts of formaldehyde after derivatization with 2,4‐dinitrophenylhydrazine. The analyses were performed by high‐performance liquid chromatography followed by UV detection. Several variables affecting the extraction efficiency of the formaldehyde, i.e., sample pH, amount of sorbent, salt concentration, extraction time and desorption conditions were investigated and optimized. The best working conditions were as follows: sample pH, 5; amount of sorbent, 40 mg; NaCl concentration, 20% w/v; sample volume, 20 mL; extraction time, 12 min; and 100 μL of methanol for desorption of the formaldehyde within 3 min. Under the optimal conditions, the performance of the proposed method was studied in terms of linear dynamic range (10–500 μg/L), correlation coefficient (R2 ≥ 0.998), precision (RSD% ≤ 5.5) and limit of detection (4 μg/L). Finally, the developed method was successfully applied for extraction and determination of formaldehyde in tap, rain and tomato water samples, and satisfactory results were obtained.  相似文献   

2.
Magnetite nanoparticles incorporated into alginate beads and coated with a polypyrrole adsorbent were prepared (polypyrrole/Fe3O4/alginate bead) and used as an effective magnetic solid‐phase extraction sorbent for the extraction and enrichment of endocrine‐disrupting compounds (estriol, β‐estradiol and bisphenol A) in water samples. The determination of the extracted endocrine‐disrupting compounds was performed using high‐performance liquid chromatography with a fluorescence detector. The effect of various parameters on the extraction efficiency of endocrine disrupting compounds were investigated and optimized including the type and amount of sorbent, sample pH, extraction time, stirring speed, and desorption conditions. Under optimum conditions, the calibration curves were linear in the concentration range of 0.5–100.0 μg/L, and the limit of detection was 0.5 μg/L. The developed method showed a high extraction efficiency, the recoveries were in the range of 90.5 ± 4.1 to 98.2 ± 5.5%. The developed sorbent was easy to prepare, was cost‐effective, robust, and provided a good reproducibility (RSDs < 5%), and could be reused 16 times. The developed method was successfully applied for the determination of endocrine‐disrupting compounds in water samples.  相似文献   

3.
This work is the first study on the extraction efficiency of self‐doped polyaniline that is immobilized on the graphene‐modified magnetic nanoparticles. The new material was used as a sorbent for the magnetic solid‐phase extraction of methyl‐, propyl‐, and butylparabens. The use of graphene provides a high surface area and prevents aggregation of the nanoparticles. The self‐doped polyaniline also provides multifunctionality, high extraction capacity, and chemical stability even in the basic medium. The parabens were acetylated for determination by gas chromatography with flame ionization detection. The effects of monomer ratio, extraction solvent, sorbent amount, sample volume, desorption solvent volume, adsorption and desorption times, and sample ionic strength were optimized. Preconcentration factors obtained were from 190 to 310. The detection limits of the method were <2.8 μg/L. Linear ranges of the method were 5–2000 μg/L for propyl and butyl parabens, and 10–2000 μg/L for methyl paraben. The method was applied for the determination of the parabens in cosmetic products and extraction recoveries were 89–101% with RSDs ≤7.9%.  相似文献   

4.
A rapid dispersive micro‐solid phase extraction (D‐μ‐SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM‐41 was used as sorbent in d ‐μ‐SPE of the azole compounds from biological fluids. Important D‐μ‐SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB‐C18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile–0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v /v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1–10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra‐ and inter‐day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3–114.8%. The MCM‐41‐D‐μ‐SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis.  相似文献   

5.
In this research, a new ultrasound‐assisted dispersive micro‐solid‐phase extraction method based on N‐doped mesoporous carbon sorbent followed by high‐performance liquid chromatography equipped with diode array detector for trace measurement of 1‐hydroxypyrene as a metabolite of exposure to polycyclic aromatic hydrocarbons was optimized. Herein, the hard template method was used for the preparation of N‐doped mesoporous carbon sorbent. The prepared sorbent was characterized using the Brunauer–Emmett–Teller method, transmission electron microscopy, and elemental analysis. Parameters affecting the extraction of the target metabolite were investigated using the Box–Behnken design method. Considering optimum parameters, the plotted calibration curve for 1‐hydroxypyrene was linearly correlated with the concentration span of 0.1–50 μg/L for urine media. The accuracy of the optimized procedure was examined through the relative recovery tests on the fortified urine specimens. The relative recoveries fell between 95 and 101%. The method detection limit of the proposed procedure was also calculated to be 0.03 μg/L.  相似文献   

6.
The approach of this work was to study the capability of graphene‐based materials in the field of biological sample preparation. A polypyrrole/graphene composite was synthesized and characterized. The potential of the nanocomposite was investigated as a sorbent in dispersive solid‐phase extraction followed by high‐performance liquid chromatography with UV detection for vancomycin as a model drug. The effect of different parameters influencing extraction efficiency such as sample pH and sample volume, ionic strength, extraction time, type, and volume of desorption solvent and desorption time were investigated. A comparison study was also conducted between polypyrrole/graphene and some different novel and classic sorbents. Under optimized conditions, the calibration curve for vancomycin showed linearity in the range of 0.05–10 μg/mL. In addition, limits of detection, and quantification were 0.003 and 0.01 μg/mL, respectively. The intraday and interday relative standard deviations at a concentration of 0.05 μg/mL (n = 3) were 1.6 and 2.1%, respectively. Furthermore, the proposed method was successfully applied for the determination of vancomycin in plasma and urine samples. The relative recoveries indicated the feasibility of graphene‐based sorbents in biological sample analysis.  相似文献   

7.
A selective and sensitive method was developed based on dispersive micro‐solid‐phase extraction for the extraction of hydroquinone, resorcinol, pyrocatechol and phenol from water samples prior to high‐performance liquid chromatography with UV detection. SiO2, SiO2@MPTES, and SiO2@MPTES@Au nanoparticles (MPTES = 3‐mercaptopropyltriethoxysilane) were synthesized and characterized by scanning electronic microscopy, thermogravimetric analysis, differential thermogravimetric analysis, and infrared spectroscopy. Variables such as the amount of sorbent (mg), pH and ionic strength of sample the solution, the volume of eluent solvent (μL), vortex and ultrasonic times (min) were investigated by Plackett–Burman design. The significant variables optimized by a Box–Behnken design were combined by a desirability function. Under optimized conditions, the calibration graphs of phenol and dihydroxybenzenes were linear in a concentration range of 1–500 μg/L, and with correlation coefficients more than 0.995. The limits of detection for hydroquinone, resorcinol, pyrocatechol, and phenol were 0.54, 0.58, 0.46, and 1.24 μg/L, and the limits of quantification were 1.81, 1.93, 1.54, and 4.23 μg/L, respectively. This procedure was successfully employed to determine target analytes in spiked water samples; the relative mean recoveries ranged from 93.5 to 98.9%.  相似文献   

8.
In this work, an efficient sample preparation method termed solvent‐assisted dispersive solid‐phase extraction was applied. The used sample preparation method was based on the dispersion of the sorbent (benzophenone) into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was achieved by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre‐concentration of the butachlor, the cloudy solution was centrifuged and butachlor in the sediment phase dissolved in ethanol and determined by gas chromatography with flame ionization detection. Under the optimized conditions (solution pH = 7.0, sorbent: benzophenone, 2%, disperser solvent: ethanol, 500 μL, centrifuged at 4000 rpm for 3 min), the method detection limit for butachlor was 2, 3 and 3 μg/L for distilled water, waste water, and urine sample, respectively. Furthermore, the preconcentration factor was 198.8, 175.0, and 174.2 in distilled water, waste water, and urine sample, respectively. Solvent‐assisted dispersive solid‐phase extraction was successfully used for the trace monitoring of butachlor in urine and waste water samples.  相似文献   

9.
In this study, a hydrophilic deep eutectic solvent was synthesized as a carrier and disperser of magnetic nanoparticles based on ferrofluid and used to develop the dispersive micro‐solid‐phase extraction method. Ethylene glycol/tetramethylammonium chloride deep eutectic solvent and SiO2@Fe3O4 were used to provide the highly stable ferrofluid with strong sorbing properties without any additional stabilizer, which was employed to extract and determine morin in apple and grape juices, diluted and acidic extract of dried onion, and green tea infusion samples. The dispersibility of SiO2@Fe3O4 and prevention of its aggregation in the sample solution were improved using the deep eutectic solvent‐based ferrofluid. Also, it facilitated the fast injection of sorbent into the sample solution that led to an increase of the contact surface between the sorbent and analyte, and reduction of the extraction time and consumption of the sorbent. The important experimental parameters influencing the extraction efficiency of morin were examined. Under the optimal conditions, a linear calibration curve was obtained in the range of 3–500 µg/L with a determination coefficient of 0.9994. The limits of detection and quantification were of 0.91 and 2.98 µg/L, respectively. While an extraction recovery of 97.7% with relative standard deviation of 3.8% (interday) was obtained via three replicated measurements on a 30 µg/L of morin standard solution, the enrichment factor was 39.1. Finally, this method was successfully used to extract and preconcentrate morin in various samples, followed with their determination by high‐performance liquid chromatography with ultraviolet detection.  相似文献   

10.
In the present study, for the first time, we successfully employed zeolite/Fe3O4 as a new magnetic nanoparticle sorbent in magnetic solid‐phase extraction for determining phthalates in aqueous samples. Gas chromatography with flame ionization detection was used to detect the target analytes as a powerful instrumental analysis. Affecting parameters in the extraction process, including the amount of adsorbent, adsorption and desorption time, and volume of desorption solvent, were optimized using a response surface methodology based on central composite design. Under the optimum conditions, the linear range for dibutyl phthalate and bis(2‐ethylhexyl phthalate) was varied in the interval of 10–1700 and 10–1200 μg/L, respectively. Limits of detection were 2.80 μg/L for dibutyl phthalate and 3.20 μg/L for bis(2‐ethylhexyl phthalate). The recovery value for the extraction of target analytes was between 97 and 111%. The repeatability and reproducibility of the new proposed method were obtained: 10–13% and 13–13.5%, respectively. The increased sensitivity in using the proposed method has been demonstrated. Compared with previous methods, the new proposed method is an accurate, rapid, and reliable sample‐pretreatment method.  相似文献   

11.
Polyaniline coated cigarette filters were successfully synthesized and used as a solid‐phase extraction sorbent for the extraction and preconcentration of polycyclic aromatic hydrocarbons in water samples. The polyaniline helped to enhance the adsorption ability of polycyclic aromatic hydrocarbons on the sorbent through π–π interactions. The high porosity and large surface area of the cigarette filters helped to reduce backpressure and can be operated with high sample flow rate without loss of extraction efficiency. The developed sorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The parameters that affected the extraction efficiencies, i.e. polymerization time, type of desorption solvent and its volume, sample flow rate, sample volume, sample pH, ionic strength, and organic modifier were investigated. Under the optimal conditions, the method was linear over the range of 0.5–10 μg/L and a detection limit of 0.5 ng/L. This simple, rapid, and cost‐effective method was successfully applied to the preconcentration of polycyclic aromatic hydrocarbons from water samples. The developed method provided a high enrichment factor with good extraction efficiency (85–98%) and a relative standard deviation <10%.  相似文献   

12.
A molecularly imprinted polymer was selectively applied for solid‐phase extraction and diazinon residues enrichment before high‐performance liquid chromatography. Diazinon was thermally copolymerized with Fe3O4@polyethyleneglycol nanoparticles, methacrylic acid (functional monomer), 2‐hydroxyethyl methacrylate (co‐monomer), and ethylene glycol dimethacrylate (cross‐linking monomer) in the presence of acetonitrile (porogen) and 2,2‐azobisisobutyronitrile (initiator). Then, the imprinted diazinon was reproducibly eluted with methanol/acetic acid (9:1, v/v). The sorbent particles were characterized by X‐ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy. The comprehensive study of variables through experimental design showed that the maximum performance was achieved under these conditions: pH 7, 10 mL sample volume, 15 mg sorbent, 10 min vortex time, 5 min ultrasonic time, 200 μL methanol/acetic acid (9:1, v/v) as eluent, and 5 min desorption time. Under optimized conditions, the molecularly imprinted polymer solid‐phase extraction method demonstrated a linear range (0.02–5 g/mL), a correlation coefficient of 0.997, and 0.005 g/mL detection limit.  相似文献   

13.
In this work, an ampholine‐functionalized hybrid organic–inorganic silica sorbent was successfully used to extract melamine from a milk formula sample by a hydrophilic interaction solid‐phase extraction protocol. Primary factors affecting the extraction efficiency of the material such as extraction solvent, elution solvent, sample loading volume, and elution volume have been thoroughly optimized. Under the optimized hydrophilic solid‐phase extraction conditions, the recoveries of melamine spiked in milk formula samples ranged from 86.2 to 101.8% with relative standard deviations of 4.1–9.4% (n = 3). The limit of detection (S/N = 3) was 0.32 μg/g. The adsorption capacity toward melamine was 30 μg of melamine per grams of sorbent. Due to its simplicity, rapidity and cost effectiveness, the newly developed hydrophilic solid‐phase extraction method should provide a promising tool for daily monitoring of doped melamine in milk formula.  相似文献   

14.
A simple, sensitive, and inexpensive single drop liquid‐liquid‐liquid microextraction combined with isocratic RP‐HPLC and UV detection was developed for the determination of anti‐malaria drug, chloroquine. The target compound was extracted from alkaline aqueous sample solution (adjusted to 0.5 mol/L sodium hydroxide) through a thin layer of organic solvent membrane and back‐extracted to an acidic acceptor drop (adjusted to 0.02 mol/L phosphoric acid) suspended on the tip of a 25 μL HPLC syringe in the organic layer. This syringe was also used for direct injection after extraction. The linear range was 1–200 μg/L. The LOD and LOQ were 0.3 and 1.0 μg/L, respectively. Intra‐and inter‐day precisions were less than 2.0 and 2.3%, respectively. The real samples were successfully analyzed using the proposed method. The recoveries of spiked samples were more than 94.6%.  相似文献   

15.
Graphene‐Fe3O4 nanoparticles were prepared using one‐step solvothermal method and characterized by X‐ray diffraction, FTIR spectroscopy, scanning electron microscopy, and vibrating sample magnetometry. The results demonstrated that Fe3O4 nanoparticles were homogeneously anchored on graphene nanosheets. The as‐synthesized graphene‐Fe3O4 nanoparticles were employed as sorbent for magnetic solid‐phase extraction of sulfonamides in milk prior to capillary electrophoresis analysis. The optimal capillary electrophoresis conditions were as follows: 60 mmol/L Na2HPO4 containing 2 mmol/L ethylenediaminetetraacetic acid disodium salt and 24% v/v methanol as running buffer, separation voltage of 14 kV, and detection wavelength of 270 nm. The parameters affecting extraction efficiency including desorption solution, the amount of graphene‐Fe3O4 nanoparticles, extraction time, and sample pH were investigated in detail. Under the optimal conditions, good linearity (5–200 μg/L) with correlation coefficients ≥0.9910 was obtained. The limits of detection were 0.89–2.31 μg/L. The relative standard deviations for intraday and interday analyses were 4.9–8.5 and 4.0–9.0%, respectively. The proposed method was successfully applied to the analysis of sulfonamides in milk samples with recoveries ranging from 62.7 to 104.8% and relative standard deviations less than 10.2%.  相似文献   

16.
A graphene oxide reinforced polymeric ionic liquids monolith was obtained by copolymerization of graphene oxide doped 1‐(3‐aminopropyl)‐3‐(4‐vinylbenzyl)imidazolium 4‐styrenesulfonate monomer and 1,6‐di‐(3‐vinylimidazolium) hexane bihexafluorophosphate cross‐linking agent. Coupled to high‐performance liquid chromatography, the monolith was used as a solid‐phase microextraction sorbent to analyze several phenolic compounds in aqueous samples. Under the optimized extraction and desorption conditions, linear ranges were 5–400 μg/L for 3‐nitrophenol, 2‐nitrophenol, and 2,5‐dichlorophenol and 2–400 μg/L for 4‐chlorophenol, 2‐methylphenol, and 2,4,6‐trichlorophenol (R2 = 0.9973–0.9988). The limits of detection were 0.5 μg/L for 3‐nitrophenol and 2‐nitrophenol and 0.2 μg/L for the rest of the analytes. The proposed method was used to determine target analytes in groundwater from an industrial park and river water. None of the analytes was detected. Relative recoveries were in the range of 75.5–113%.  相似文献   

17.
A new mesoporous silica based on the sol–gel material cyanopropyltriethoxysilane (CNPrTEOS) was successfully synthesized by the hydrolysis and condensation of CNPrTEOS in the presence of ammonium solution as catalyst and methanol as solvent. It was used as a solid‐phase extraction sorbent for the simultaneous extraction of three organophosphorus pesticides, namely, polar dicrotophos and non‐polar diazinon and chlorpyrifos. Analysis was performed using high‐performance liquid chromatography with UV detection. CNPrTEOS was characterized by FTIR spectroscopy, field‐emission scanning electron microscopy and nitrogen gas adsorption. The surface area and average pore diameter of the optimum sol–gel CNPrTEOS are 379 m2/g and 4.7 nm (mesoporous), respectively. The proposed solid‐phase extraction based on CNPrTEOS exhibited good linearity in the range of 0.8–100 μg/L, satisfactory precision (1.15–3.82%), high enrichment factor (800) and low limit of detection (0.072–0.091 μg/L). The limits of detection obtained using the proposed solid‐phase extraction method are well below the maximum residue limit set by European Union and are also lower (13.6–48.5×) than that obtained by using a commercial CN‐SPE cartridge (0.98–4.41 μg/L). The new mesoporous sol–gel CNPrTEOS showed promising alternative as SPE sorbent material for the simultaneous extraction of polar and non‐polar organophosphorus pesticides.  相似文献   

18.
In this research, solvent‐assisted dispersive micro‐SPE was introduced as a simple modified technique for the determination of parabens in water and cosmetic samples. Aminopropyl‐functionalized magnetite nanoparticles (MNPs) were successfully synthesized and applied. GC with photoionization detector was used for the separation and detection of parabens. In this method, hexylacetate (15 μL) as a solvent and aminopropyl‐functionalized MNPs (5 μg) as a sorbent were added to an aqueous sample (10 mL) and then the sample was sonicated. Dispersed magnetite was collected in the bottom of the conical tube by using a strong magnet and then ACN was added as a desorption solvent. Forty microliters of this solvent was transferred into a microvial and then acetic anhydride and pyridine were added, thus derivatization was performed by acetic anhydride. After evaporation, 1 μL of derivatized sample was injected into a gas chromatograph for analysis. Several important parameters, such as kind of organic solvent, desorption solvent and volume, amount of aminopropyl‐functionalized MNPs and effect of salt addition were investigated. Under optimum conditions, the limits of detection achieved were between 50 and 300 ng/L, with RSDs (n = 5) lower than 8%. Under the optimum conditions, the enrichment factors ranged from 217 to 1253 and the extraction recoveries ranged from 10 to 62%. The recoveries were obtained for the analytes in river water and mouthwash solution and hand cream in the range of 87–103%. The advantages of proposed method are simplicity of operation, rapidity, high extraction yields, and environmental friendly character.  相似文献   

19.
An efficient on‐site extraction technique to determine carcinogenic heterocyclic aromatic amines in seawater has been reported. A micro‐solid‐phase extraction device placed inside a portable battery‐operated pump was used for the on‐site extraction of seawater samples. Before on‐site applications, parameters that influence the extraction efficiency (extraction time, type of sorbent materials, suitable desorption solvent, desorption time, and sample volume) were investigated and optimized in the laboratory. The developed method was then used for the on‐site sampling of heterocyclic aromatic amines determination in seawater samples close to distillation plant. Once the on‐site extraction completed, the small extraction device with the analytes was brought back to the laboratory for analysis using high‐performance liquid chromatography with fluorescence detection. Based on the optimized conditions, the calibration curves were linear over the concentration range of 0.05–20 μg/L with correlation coefficients up to 0.996. The limits of detection were 0.004–0.026 μg/L, and the reproducibility values were between 1.3 and 7.5%. To evaluate the extraction efficiency, a comparison was made with conventional solid‐phase extraction and it was applied to various fortified real seawater samples. The average relative recoveries obtained from the spiked seawater samples varied in the range 79.9–95.2%.  相似文献   

20.
As a novel solid‐phase extraction material, zinc sulfide nanosheets were prepared by a simple method and were used to extract flavonoids. We used scanning electron microscopy to show its nanosheet morphology and energy dispersive X‐ray spectroscopy and powder X‐ray diffraction to confirm its chemical and phase compositions. Coupled to a high‐performance liquid chromatography, the zinc sulfide nanosheets were packed into a microcolumn and were used to extract four model flavonoids to examine their extraction ability. The parameters of sample loading and elution were investigated. Under optimized conditions, the analytical method for flavonoids was established. For the method, wide linearities from 1 to 250 μg/L and low limits of detection from 0.25 to 0.5 μg/L were obtained. The relative standard deviations for single column repeatability and column to column reproducibility were less than 7.7 and 10.4%, respectively. The established method was also used to analyze two real samples and the recoveries from 88.7 to 98.2% further proved the reliability of the method. Moreover, the zinc sulfide nanosheets have good stability and that in one column can be reused for more than 50 times. This work proves that the prepared zinc sulfide nanosheets are a good candidate as the flavonoids sorbent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号