首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new electrochemical sensor based on Poly(Isoleucine) modified glassy carbon electrode decorated with platinum nanoparticles (Pt/Poly(Isoleucine)/GCE) was developed for sensitive individual and simultaneous determination of hydroquinone (HQ) and catechol (CC). Scanning electron microscopy (SEM), Electrochemical impedance spectroscopy (EIS), Cyclic voltammetry (CV) and Differential pulse voltammetry (DPV) were performed in order to characterize the Pt/Poly(Isoleucine)/GCE nanocomposite. For simultaneous determination of HQ and CC, Pt/Poly(Isoleucine)/GCE showed wide linear range between the 0.01–100.0 μM. The detection limits were 0.006 μM for HQ and 0.005 μM for CC. The Pt/Poly(Isoleucine)/GC electrode exhibited good sensitivity and reliability in the simultaneous electroanalysis of two isomers in PBS of pH 7.5. The modified electrode was used to detect the isomers in naturel samples.  相似文献   

2.
A novel carbon paste electrode modified with nanosized mesoporous MCM-41 was prepared, and used as an electrochemical sensor to study the electro oxidation of levodopa (LD), carbidopa (CD) and their mixtures. Using differential pulse voltammetry (DPV), a highly selective and simultaneous determination of LD and CD has been explored at the modified electrode. The electrochemical sensor displayed a good resolving function for the overlapping voltammetric responses of LD and CD into two separate peaks with a potential difference of 370 mV. DPV peak currents of LD increased linearly with concentration over the 0.13 μM to 1250.00 μM range and exhibited a detection limit of 0.072 μM. Also, the proposed electrochemical sensor was used for the determination of LD and CD in some real samples, using the standard addition method.  相似文献   

3.
This paper describes the simultaneous determination of ascorbic acid (AA), norepinephrine (NE) and uric acid (UA) using a graphene modified glassy carbon electrode (GME) in pH 4.0 phosphate buffer solution. The electrochemical behaviors of AA, NE and UA at a bare glassy carbon electrode (GCE) and the GME were studied by cyclic voltammetry. Bare GCE failed to resolve the voltammetric signals of AA, NE and UA in a mixture, whereas the GME not only resolved their voltammetric signals, but also exhibited excellent electrocatalytic activity towards their electrochemical oxidation. The oxidation peak currents of AA, NE and UA were linearly proportional to their concentrations over the range of 1.0.0–1000.0, 0.6–45.0 and 1.0–100.0 μM, respectively, and their detection limits were 1.2, 0.10 and 0.60 μM, respectively, The modified electrode is of excellent sensitivity and selectivity, and has been satisfactorily used for the simultaneous determination of AA, NE and UA in their ternary mixture.  相似文献   

4.
The present work demonstrates that simultaneous determination of adrenalin (AD) and paracetamol (PAR) can be performed on single‐walled carbon nanotube/chitosan/ionic liquid modified glassy carbon electrode (SWCNT‐CHIT‐IL/GCE). The electro‐oxidations of AD and PAR were investigated with cyclic voltammetry (CV), differential pulse voltammetry (DPV) and also chronoamperometry (CA) methods. DPV experiments showed that the oxidation peak currents of AD and PAR are proportional to the corresponding concentrations over the 1–580 μmol/L and 0.5–400 μmol/L ranges, respectively. The RSD at a concentration level of 15 μmol/L AD and 15 μmol/L PAR were 1.69% and 1.82%, respectively. Finally the modified electrode was used for simultaneous determination of AD and PAR in real samples with satisfactory results.  相似文献   

5.
Three reduced graphene oxide nanocomposites were employed to achieve the simultaneous electrochemical determination of multi-drugs including acetaminophen (ACTM), carbendazim (CB) and ciprofloxacin (CFX). All nanocomposite modified electrodes showed improved current responses for three drugs. Notably cauliflower-like platinum nanoparticles decorated reduced graphene oxide modified electrode (or Pt−RGO/GCE) exhibited the best performance in terms of electrochemical stability. Using Pt−RGO/GCE, the linear detect ranges of 30–120 μM, 25–115 μM and 10–25 μM, and detection limit values of 3.49, 2.96, and 1.53 μM were achieved for ACTM, CB and CFX respectively. The electrode was further used for the successful determination of above drugs in tap and river water using differential pulse voltammetry. From the obtained results, we believe that Pt-RGO/GCE is highly promising for the fabrication of robust electrochemical sensors for simultaneously determining ACTM, CB and CFX or similar types of drugs in the future.  相似文献   

6.
《Analytical letters》2012,45(10):1525-1536
Magnetic chitosan microspheres (MCMS) and thionine were incorporated in a modified electrode for the simultaneous sensitive determination of dopamine (DA) and uric acid (UA). Due to the unique properties of the MCMS and the electron mediation of thionine, this modified electrode showed excellent electrocatalytic oxidation toward dopamine and uric acid with a large separation of peak potentials and a significant enhancement of peak currents. However, the electrochemical behavior of ascorbic acid may be depressed at the modified electrode. Differential pulse voltammetry was used for the simultaneous sensitive determination of dopamine and uric acid in the presence of excess ascorbic acid at this modified electrode. The current responses showed excellent linear relationships in the range of 2–30 µM and 9–100 µM for dopamine and uric acid, respectively. The detection limits were estimated to be 0.5 µM and 2.3 µM for dopamine and uric acid, respectively. In addition, this modified electrode showed excellent repeatability, good stability, and satisfactory reliability, thus indicating potential for the practical applications.  相似文献   

7.
A novel ZnS nanoparticle‐modified carbon paste electrode (ZnSNP‐MCPE) was fabricated and used to study the electrooxidation of thioridazine (TR) using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The determination conditions, such as accumulation time, pH of solution, and modifier amount were optimized. The mechanism of the electrooxidation process on the surface of the modified electrode was studied electrochemically. A linear range of 0.1–36.0 µM with detection limit of 65.0 nM was obtained for TR. In a mixture containing TR and olanzapine (OLZ), the DPV peaks of two compounds can be well separate from each other with a potential difference of 425 mV. Finally, this method was successfully applied to determinate the TR content in real samples.  相似文献   

8.
The redox response of a modified carbon nanotube paste electrode of ferrocenedicarboxylic acid was investigated. Cyclic voltammetry, differential pulse voltammetry, and chronoamperometry were used to investigate the electrochemical behavior of levodopa (LD) at modified electrode. Under the optimized conditions (pH 5.0), the modified electrode showed high electrocatalytic activity toward LD oxidation; the overpotential for the oxidation of LD was decreased by more than 190 mV, and the corresponding peak current increased significantly. Differential pulse voltammetric peak currents of LD increased linearly with its concentrations at the range of 0.04 to 1,100 μM, and the detection limit (3σ) was determined to be 12 nM. The diffusion coefficient ( D = 9.2 ×10 - 6cm2/s ) \left( {D = {9}.{2} \times {1}{0^{ - {6}}}{\hbox{c}}{{\hbox{m}}^2}/{\hbox{s}}} \right) and transfer coefficient (α = 0.49) of LD were also determined. Mixture of LD, NADH, and tryptophan (TRP) can be separated from one another by differential pulse voltammetry. These conditions are sufficient to allow determination of LD, NADH, and TRP both individually and simultaneously. The modified electrode showed good reproducibility, remarkable long-term stability, and especially good surface renewability by simple mechanical polishing. The results showed that this electrode could be used as an electrochemical sensor for determination of LD, NADH, and TRP in real samples such as urine and water samples.  相似文献   

9.
A modified electrode was prepared by modification of the carbon paste electrode (CPE) with a nanostructured material. This nanostructure with electrocatalytic activity was synthesized by combination of poly pyrrole and copper oxide nanoparticles (PPy/CuO). The structure and morphology of PPy/CuO was studied. The fabricated modified electrode (CPE‐PPy/CuO) exhibited an excellent electrocatalytic activity toward levodopa (L‐DOPA) and uric acid (UA) oxidation because of high conductivity, low electron transfer resistance and catalytic effect. The CPE‐PPy/CuO had a lower overvoltage and enhanced electrical current with respect to the bare CPE for both L‐DOPA and UA. Also, the modified electrode showed a good resolution for the overlapped anodic peaks of L‐DOPA and UA. This electrode was used for the successful simultaneous determination of L‐DOPA and UA. The electrochemical sensor responded to L‐DOPA and UA in the concentration range of 0.050–1200 μM and 0.040–2000 μM, respectively. The detection limits were obtained by differential pulse voltammetry as 15 nM for L‐DOPA and 20 nM for UA. Finally, the proposed electrode was used for determination of L‐DOPA and UA in real samples using standard addition method.  相似文献   

10.
A Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop-casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5–200 μM with differential pulse voltammetry (DPV) and the detection limit was 0.051 μM. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determination of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations.  相似文献   

11.
A new chemically modified electrode is constructed based on multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) for simultaneous determination of acetaminophen (ACT) and mefenamic acid (MEF) in aqueous buffered media. The measurements were carried out by application of differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA) methods. Application of DPV method showed that the linear relationship between oxidation peak current and concentration of ACT and MEF were 1 μM to 145 μM, and 4 μM to 200 μM, respectively. The analytical performance of this sensor has been evaluated for detection of ACT and MEF in human serum, human urine and a pharmaceutical preparation with satisfactory results.  相似文献   

12.
Dopamine-melanin colloidal nanospheres (Dpa-melanin CNDs)–graphene composites-modified glassy carbon electrode (GCE) was prepared by a simple procedure and then successfully used to simultaneously determine guanine and adenine. Scanning electron microscopy (SEM) images and transmission electron microscopy (TEM) were used to characterize the morphology of the Dpa-melanin CNSs–graphene composite. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the electrode modifying process. Differential pulse voltammetry (DPV) was used to study the electrocatalytic activity toward the electrochemical oxidation of guanine and adenine. The modified electrode exhibited enhanced electrocatalytic behavior and good stability for the simultaneous determination of guanine and adenine compared with bare GCE. The electrochemical biosensor exhibited wide linear range of 0.5 to 150 μM with detection limit of 0.05 and 0.03 μM for guanine and adenine detection (S/N?=?3), respectively. Furthermore, the biosensor showed high sensitivity, good selectivity, good reproducibility, and long-term stability to guanine and adenine detection. At the same time, the fabricated electrode was successfully applied for the determination of guanine and adenine in denatured DNA samples with satisfying results. These results demonstrated that Dpa-melanin CNSs–graphene composite was a promising substrate for the development of high-performance electrochemical biosensor.  相似文献   

13.
Simultaneous determination of a neurotransmitter, dopamine (DA), and ascorbic acid (AA) is achieved at neutral pH on a chitosan incorporating cetyltrimethylammonium bromide (CTAB) modified glassy carbon (GC) electrode. Differential pulse voltammetry (DPV) technique was used to investigate the electrochemical response of DA and AA at a glassy carbon electrode modified with chitosan incorporating CTAB. An optimum 6.0 mmol L?1 of CTAB together with 0.5 wt% of chitosan was used to improve the resolution and the determination sensitivity. In 0.1 mol L?1 aqueous phosphate buffer solution of pH 6.8, the chitosan‐CTAB modified electrode showed a good electrocatalytic response towards DA and AA. The anodic peak potential of DA shifted positively, while that of AA shifted negatively. Thus, the difference of the anodic peaks of DA and AA reached 0.23 V, which was enough to separate the two anodic peaks very well. The presented method herein could be applied to the direct simultaneous determination of DA and AA without prior treatment. The anodic peak currents (Ipa) of DPV are proportional to DA in the concentration range of 8 μM to 1000 μM, to that of AA 10 μM to 2000 μM, with correlation coefficients of 0.9930 and 0.9945, respectively. The linear range is much wider than previously reported.  相似文献   

14.
The electrooxidation of dopamine (DA), uric acid (UA) and their mixture on a gold electrode modified by a self-assembled monolayer of 2-(3,4-dihydroxyphenyl)-1,3-dithialone has been studied by cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV). CV was used to investigate the redox properties of the modified electrode at various scan rates and the apparent charge transfer rate constant (k(s)), and transfer coefficient (α) were calculated. The mediated oxidation of DA at the modified electrode under the optimum condition (pH = 7.0) in CV occurs at a potential about 220 mV less positive than that of the unmodified gold electrode. The values of electron transfer coefficients (α), catalytic rate constant (k) and diffusion coefficient (D) were calculated for DA, using electrochemical methods. DPV exhibited a linear dynamic range over the concentration range of 0.2-250.0 μM and a detection limit (3σ) of 0.07 μM for DA. The modified electrode was used for simultaneous determination of DA and UA by DPV. The results showed that the electrode is highly efficient for the catalytic electrooxidation of DA and UA, leading to a remarkable peak resolution (~350 mV) for two compounds. The electrode was used for the determination of DA in an injection sample.  相似文献   

15.
The electrocatalytic oxidation of nicotinamide adenine dinucleotide (NADH) was studied on nanoTiO2 modified sol‐gel electrode, using cyclic voltammetry, chronoamperometry and differential pulse voltammetry as diagnostic techniques. It is demonstrated that TiO2 nanoparticles on sol‐gel network catalyze the oxidation of NADH in the absence of any electron transfer mediators. Effect of various parameters such as pH, scan rate, TiO2 percentage on the response of modified electrode was studied. In addition, scanning electron microscopy (SEM) was used to characterize the surface morphology of the spots. A dynamic range between 0.5–50 μM with detection limit of 0.35 μM was obtained with DPV studies. This method was successfully used for determination of NADH in cucumber cotyledons samples. The electrode showed relatively good stability over more than 2 months.  相似文献   

16.
Single‐walled carbon nanotubes (SWCNTs) were immobilized on glassy carbon (GC) electrode by drop casting The resulting modified electrode (represented as GC/SWCNTs) efficiently oxidizes acetaminophen (AC), dopamine (DA) and pyridoxine (PY) by decreasing the respective oxidation potentials and increasing peak currents in comparison to bare GC electrode. The extent of lowering of overpotentials is in the order of AC>PY>DA, in agreement with the order of decrease in the HOMO‐LUMO energy gap (ΔE) of these analytes, as determined from Density Functional Theory (DFT) calculations. DFT calculations further reveal that due to the interaction of the analytes on the SWCNT(10,10) there is a negative charge density transfer (higher probability of electron transfer, lower ΔE value) to the frontier molecular orbitals of the analytes, which eases their oxidation. Since AC, DA and PY oxidize distinctly at distinct potential values, the present SWCNTs modified electrodes could be used to simultaneously determine them. Cyclic voltammetry, differential pulse voltammetry and amperometry techniques are utilized to understand the electrochemical characteristics of the analytes (AC, DA and PY) and subsequent sensing of them at the GC/SWCNTs electrode. The electrode is then applied to the determination of AC as a case study. Sensitivity, detection limit and linear calibration range for the AC are found to be 7.9 μA μM?1 cm?2, 1.1 μM and 2.0–100.0 μM, respectively. The increased electroactive surface area of the GC/SWCNTs increases the oxidation peak currents and hence increases the sensitivity of the determination.  相似文献   

17.
《Electroanalysis》2017,29(6):1618-1625
An electrochemical sensor was developed based on gold nanoparticles incorporated in mesoporous MFI zeolite for the determination of purine bases. Au nanoparticles (AuNPs) were incorporated into the mesoporous MFI zeolite (AuNPs/m‐MFI) by post‐grafting reaction. The composite materials were characterized by transmission electron microscopy (TEM), X‐ray photoelectron spectroscopy (XPS) and electrochemical methods. Au nanoparticles with a size of 5‐20 nm are uniformly dispersed in the pores of mesoporous MFI zeolite. And the morphology of MFI zeolite can be perfectly kept after pore expansion and Au nanoparticles incorporation. The electrocatalytic oxidation of purine bases (guanine and adenine in DNA) is investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The surface‐confined Au nanoparticles provide the good catalytic activity for oxidation of purine bases. The simultaneous detection of guanine and adenine can be achieved at AuNPs/m‐MFI composites modified glassy carbon electrode (GCE). The electrochemical sensor based on AuNPs/m‐MFI exhibits wide linear range of 0.5–500 μM and 0.8–500 μM with detection limit of 0.25 and 0.29 μM for guanine and adenine, respectively. Moreover, the electrochemical sensor is applied to evaluation of guanine and adenine in herring sperm DNA samples with satisfactory results.  相似文献   

18.
A new voltammetric method for simultaneous determination of caffeine and pyridoxine present in different types of commercial energy drinks has been developed. This electroanalytical method is based on anodic oxidation of these biologically active nitrogen‐containing heterocycles at glassy carbon electrode covered with thin layer of sulfonated fluoropolymer Nafion® using differential pulse voltammetry in 0.1 M Britton‐Robinson buffer of pH 4.5 at potential step 5 mV, potential amplitude 70 mV, and scan rate 50 mV/s. Linear ranges for caffeine and pyridoxine determination were 63.1–600 μM and 7.5–200 μM with the detection limits of 18.9 and 2.2 μM, respectively. It was validated using high‐performance liquid chromatography with spectrophotometric detection. Obtained results have shown that voltammetric approach is very simple and low‐cost analytical method which can be used for routine determination of caffeine and pyridoxine in energy drinks.  相似文献   

19.
《Electroanalysis》2006,18(24):2458-2466
A promising electrochemical biosensor was fabricated by electrochemical grafting of ribonucleic acid (RNA) at 1.8 V (vs. SCE) on glassy carbon electrode (GCE) (denoted as RNA/GCE), for simultaneous detection of dopamine (DA) and uric acid (UA) with coexistence of excess amount of ascorbic acid (AA). The electrode was characterized by X‐ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The RNA modified layer on GCE exhibited superior catalytic ability and anionic exclusive ability in comparison with the DNA modified electrode. Three separated anodic DPV peaks were obtained at 0.312, 0.168 and ?0.016 V for UA, DA and AA, respectively, at the RNA/GCE in pH 7.0 PBS. In the presence of 2.0 mM AA, a linear range of 0.37 to 36 μM with a detection limit of 0.2 μM for DA, and in the range of 0.74 to 73 μM with a detection limit of 0.36 μM for UA were obtained. The co‐existence of 5000 fold AA did not interfere with the detection of DA or UA. The modified electrode shows excellent selectivity, good sensitivity and good stability.  相似文献   

20.
A new, simple and low cost voltammetric method for the determination of cefpirome in pharmaceutical preparations has been developed using multiwalled carbon nanotube modified glassy carbon electrode (MWCNT), which showed stable response with enhanced selectivity and sensitivity over the bare glassy carbon electrode. A multiwalled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE) is used for the simultaneous determination of cefpirome by differential pulse voltammetry and square wave voltammetry. Results indicated that cathodic peak of cefpirome is greatly improved at MWCNT modified GC electrode as compared with the bare GC electrode showing excellent electrocatalytic activity towards cefpirome reduction. Linear calibration curves are obtained over the concentration range 100-600 μg mL(-1) in Britton Robinson buffer at pH 4.51 with limit of detection (LOD) and limit of quantification (LOQ) are 0.647 μg mL(-1) and 2.159 μg mL(-1) using SWV and 5.540 μg mL(-1) and 18.489 μg mL(-1) using DPV, respectively. The described method is rapid and can be successfully applied for the determination of cefpirome in bulk form and pharmaceutical formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号