首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Regular vertical aircraft sampling has been performed in the lower troposphere above Griffin Forest, near Aberfeldy, Perthshire, UK (56 degrees 37'N, 3 degrees 47'W), between February 2003 and May 2004, for analysis of O2/N2, CO2 and delta13C of CO2. We sampled flasks between 800 and 3100 m above sea level. The peak-to-peak amplitude of the seasonal cycle of O2/N2 decreases from 171 per meg at 800 m to 113 per meg at 3100 m. Furthermore, the seasonal cycle is shifted from low to high altitudes with a lag of about 1 month. The same features are observed for CO2 with a decrease in the peak-to-peak amplitude of the seasonal cycle from 17.6 ppm at 800 m to 11.4 ppm at 3100 m. The vertical profiles show decreasing O2/N2 ratios in summer and increasing O2/N2 ratios in wintertime with increasing sampling height, due to surface exchange of oxygen with the land biosphere and the ocean. The O2:CO2 exchange ratios of the vertical profiles vary between -1.5 and -2.4 mol O2/mol CO2.  相似文献   

2.
A compact fiber-optic diode laser spectrometer for the measurement of CO and CO(2) gas concentrations in the near infrared around 1580 nm is described. By use of a balanced receiver to suppress diode laser intensity noise a sensitivity of 6.4 x 10(-7) at 1 Hz system bandwidth was achieved. At a reduced pressure of 80 hPa this equals to a detection limit of 5.1 ppm CO and 9.1 ppm CO(2) with 1m absorption path length. The observed line shapes of the 2f wavelength modulation spectroscopy (WMS) scheme are analyzed theoretically and experimentally. Accurate measurements of magnitude and phase of the diode laser frequency and intensity modulation responses were found critically for modeling the observed line shapes. In situ measurements of gas dissociation processes inside of a medium-power carbon dioxide laser are presented as an application example.  相似文献   

3.
An analytical technique was developed to analyze light non-methane hydrocarbons (NMHC), including ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane, n-hexane, isoprene, benzene and toluene from whole air samples collected in 2.5l-glass flasks used by the National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Global Monitoring Division (NOAA ESRL GMD, Boulder, CO, USA) Cooperative Air Sampling Network. This method relies on utilizing the remaining air in these flasks (which is at below-ambient pressure at this stage) after the completion of all routine greenhouse gas measurements from these samples. NMHC in sample aliquots extracted from the flasks were preconcentrated with a custom-made, cryogen-free inlet system and analyzed by gas chromatography (GC) with flame ionization detection (FID). C2-C7 NMHC, depending on their ambient air mixing ratios, could be measured with accuracy and repeatability errors of generally < or =10-20%. Larger deviations were found for ethene and propene. Hexane was systematically overestimated due to a chromatographic co-elution problem. Saturated NMHC showed less than 5% changes in their mixing ratios in glass flask samples that were stored for up to 1 year. In the same experiment ethene and propene increased at approximately 30% yr(-1). A series of blank experiments showed negligible contamination from the sampling process and from storage (<10 pptv yr(-1)) of samples in these glass flasks. Results from flask NMHC analyses were compared to in-situ NMHC measurements at the Global Atmospheric Watch station in Hohenpeissenberg, Germany. This 9-months side-by-side comparison showed good agreement between both methods. More than 94% of all data comparisons for C2-C5 alkanes, isoprene, benzene and toluene fell within the combined accuracy and precision objectives of the World Meteorological Organization Global Atmosphere Watch (WMO-GAW) for NMHC measurements.  相似文献   

4.
In this paper we present an automated system for simultaneous measurement of CO(2) concentration, delta(13)C and delta(18)O from small (<1 mL) air samples in a short period of time (approximately 1 hour). This system combines continuous-flow isotope ratio mass spectrometry (CF-IRMS) and gas chromatography (GC) with an inlet system similar to conventional dual-inlet methods permitting several measurement cycles of standard and sample air. Analogous to the dual-inlet method, the precision of this system increases with the number of replicate cycles measured. The standard error of the mean for a measurement with this system is 0.7 ppm for the CO(2) concentration and 0.05 per thousand for the delta(13)C and delta(18)O with four replicate cycles and 0.4 ppm and 0.03 per thousand respectively with nine replicate cycles. The mean offset of our measurements from NOAA/CMDL analyzed air samples was 0.08 ppm for the CO(2) concentration, 0.01 per thousand for delta(13)C and 0.00 per thousand for delta(18)O. A specific list of the parts and operation of the system is detailed as well as some of the applications for micrometeorological and ecophysiological applications.  相似文献   

5.
The ionisation efficiencies of N2O vs. CO2 as well as their ratios were measured in detail introducing clean N2O and CO2 into the electron impact ion source of an isotope ratio mass spectrometer. Changes in the ionisation efficiency ratio (IER) were found for different electron energy settings and compared with the ratios of literature ionisation cross-section values for pure N2O and CO2. To establish the influence of mixtures of N2O and CO2 in a mass spectrometer, artificial air mixtures were prepared by mixing different amounts of N2O and CO2 from well-calibrated spike cylinders with CO2-free air. The mixing ratios varied from 8-512 ppb for N2O and from 328-744 ppm for CO2. With these mixtures the effects of varying N2O concentrations on apparent CO2 isotope ratios in air samples were determined. After applying a mass balance correction the delta13C results were consistent within small error margins. The data seemed almost independent from a particular choice for the IER of N2O vs. CO2 in the correction algorithm. For delta18O a small effect of the ionisation efficiency ratio of N2O vs. CO2 was found. Several sets of calculations were made varying the IER between 0.88 and 0.62. The dependence of delta18O was the smallest with an adopted IER of 0.68-0.72 in the mass balance correction equation for isotopic analysis of CO2 in air. For high-precision measurements of the CO2 stable isotope ratios in air samples a careful assessment of the mass spectrometer performance is necessary. Different ion sources, even different ion source settings, alter the IER of N2O vs. CO2 which is used in the N2O correction algorithm. Preferably, the specific mass spectrometric behaviour should be established with clean N2O/CO2 mixtures or with air mixtures covering a larger range of N2O concentrations.  相似文献   

6.
A fast response, open path tunable diode laser absorption spectroscopy H2O/CO2 gas analyzer suitable for eddy correlation concentration measurements in near surface turbulent environments is presented. The turbulent temperature characteristics, analysis theory, analysis methods, design structure and specifications of this dual laser analyzer are described. A fiber connected optical head with folded optical path is used to extend the resolution to ppb levels for H2O at 1.3964 microm and CO2 at 2.014 microm. The Fourier (discrete cosine) transform absorbance ratio analysis methods are outlined along with the modifications for temperature and pressure measurements in turbulent flows. Synthesis of the reference absorbance function using measured temperature, pressure and the Hitran parameters is extended with incorporation of the Hitran parameters n, gamma temperature exponent and E', lower state energy. Additionally, the mole fraction equation developed for this Hitran model is presented and an absolute calibration technique is outlined along with methods of calibration retention. Simulation results on mole fraction estimations and errors are presented for synthetic temperature and laser noise processes and are used to verify the specifications.  相似文献   

7.
Low-pressure adsorption of carbon dioxide and nitrogen was studied in both acidic and copper-exchanged forms of SSZ-13, a zeolite containing an 8-ring window. Under ideal conditions for industrial separations of CO(2) from N(2), the ideal adsorbed solution theory selectivity is >70 in each compound. For low gas coverage, the isosteric heat of adsorption for CO(2) was found to be 33.1 and 34.0 kJ/mol for Cu- and H-SSZ-13, respectively. From in situ neutron powder diffraction measurements, we ascribe the CO(2) over N(2) selectivity to differences in binding sites for the two gases, where the primary CO(2) binding site is located in the center of the 8-membered-ring pore window. This CO(2) binding mode, which has important implications for use of zeolites in separations, has not been observed before and is rationalized and discussed relative to the high selectivity for CO(2) over N(2) in SSZ-13 and other zeolites containing 8-ring windows.  相似文献   

8.
We have developed an automated, continuous-flow isotope ratio mass spectrometry (CF-IRMS) system for the analysis of delta(13)C, delta(18)O, and CO(2) concentration (micromol mol(-1)) ([CO(2)]) from 2 mL of atmospheric air. Two replicate 1 mL aliquots of atmospheric air are sequentially sampled from fifteen 100 mL flasks. The atmospheric sample is inserted into a helium stream and sent through a gas chromatograph for separation of the gases and subsequent IRMS analysis. Two delta(13)C and delta(18)O standards and five [CO(2)] standards are run with each set of fifteen samples. We obtained a precision of 0.06 per thousand, 0.11 per thousand, and 0.48 micromol mol(-1) for delta(13)C, delta(18)O, and [CO(2)], respectively, by analyzing fifty 100 mL samples filled from five cylinders with a [CO(2)] range of 275 micromol mol(-1). Accuracy was determined by comparison with established methods (dual-inlet IRMS, and nondispersive infrared gas analysis) and found to have a mean offset of 0.00 per thousand, -0.09 per thousand, and -0.26 micromol mol(-1) for delta(13)C and delta(18)O, and [CO(2)], respectively.  相似文献   

9.
Elevated-temperature pressure swing adsorption is a promising technique for producing high purity hydrogen and controlling greenhouse gas emissions. Thermodynamic analysis indicated that the CO in H_2-rich gas could be controlled to trace levels of below 10 ppm by in situ reduction of the CO_2 concentration to less than 100 ppm via the aforementioned process. The CO_2 adsorption capacity of potassiumpromoted hydrotalcite at elevated temperatures under different adsorption(mole fraction, working pressure) and desorption(flow rate, desorption time, steam effects) conditions was systematically investigated using a fixed bed reactor. It was found that the CO_2 residual concentration before the breakthrough of CO_2 mainly depended on the total amount of purge gas and the CO_2 mole fraction in the inlet syngas.The residual CO_2 concentration and uptake achieved for the inlet gas comprising CO_2(9.7 mL/min) and He(277.6 mL/min) at a working pressure of 3 MPa after 1 h of Ar purging at 300 mL/min were 12.3 ppm and0.341 mmol/g, respectively. Steam purge could greatly improve the cyclic adsorption working capacity, but had no obvious benefit for the recovery of the residual CO_2 concentration compared to purging with an inert gas. The residual CO_2 concentration obtained with the adsorbent could be reduced to 3.2 ppm after 12 h of temperature swing at 450 °C. A new concept based on an adsorption/desorption process, comprising adsorption, steam rinse, depressurization, steam purge, pressurization, and high-temperature steam purge, was proposed for reducing the steam consumption during CO/CO_2 purification.  相似文献   

10.
Trace organometallic intermediates arising from complex organic syntheses are usually quite difficult to detect spectroscopically. In situ FTIR and in situ NMR are the only techniques that are used with any regularity for such studies. In this contribution, high-pressure in situ Raman spectroscopic measurements were performed for the rhodium catalyzed hydroformylation of 3,3-dimethylbut-1-ene using Rh4(CO)12 as catalyst precursor at 298 K – a reaction extensively studied previously by more sensitive in situ FTIR. The Raman spectroscopic measurements were analyzed using the band-target entropy minimization (BTEM) algorithm. As expected, the pure component spectra of dissolved CO, 3,3-dimethylbut-1-ene, and 4,4-dimethylpentanal were easily recovered. In addition, the pure component spectra of the precursor Rh4(CO)12 and the intermediate RCORh(CO)4 (R = (CH3)3CCH2CH2) were successfully reconstructed – even though the mean concentrations of both species were on the order of 150 ppm. The BTEM estimate of the Raman spectrum of RCORh(CO)4 is reported for the first time. This Raman spectrum is consistent with the DFT predicted spectrum. This study represents the first combined application of Raman spectroscopy and BTEM analysis to a homogeneously catalyzed metal-mediated reaction. The potential and limitations of this general approach are discussed.  相似文献   

11.
In spite of extensive efforts, even the most experienced laboratories dealing with isotopic measurements of atmospheric CO2 still suffer from poor inter-laboratory consistency. One of the complicating factors of these isotope measurements is the presence of N2O, giving rise to mass overlap in the isotope ratio mass spectrometer (IRMS). The aim of the experiment reported here has been twofold: first, the re-establishment of the correction for 'mechanical' interference of N2O in the IRMS, along with its variability and drift, and the best way to quantitatively determine the correction factors. Second, an investigation into secondary effects, i.e. the influence of N2O admitted with the CO2 sample on the "cross contamination" between sample and (pure CO2) working gas. To make the suspected effects better detectable, isotopically enriched CO2 gas with different concentrations of N2O has been measured for the first time. No evidence of secondary effects was observed, from which we conclude that N2O is not a major player in the inter-laboratory consistency problems. Still, we also found that the determination of the 'mechanical' N2O correction needs to be very carefully determined for each individual IRMS, and should be periodically re-determined. We show that the determination of the correction should be performed using CO2/N2O mixtures with concentration ratios around that of the atmosphere, as the extrapolation from pure gas end member behaviour will give erroneous results due to non-linearities. For our IRMS, a VG SIRA series II, we find a correction of 0.23 per thousand for delta45CO2 and 0.30 per thousand for delta46CO2 of atmospheric samples, (with 0.85 per thousand mixing ratio). This implies that the relative ionisation efficiency (E) value associated with this machine is 0.75.  相似文献   

12.
A mobile laboratory was developed to administer a controlled flow of (13)C labelled CO(2) at ambient concentrations ( approximately 350 ppm) in the field. The stable isotope delivery (SID) system consists of an isotope-mixing unit with flow control to a series of 12 independent labelling chambers. In-line CPU controlled infrared gas analysers allow automated measurement of chamber CO(2) concentrations and gas flow management. A preliminary experiment was established on an upland pasture located at the NERC Soil Biodiversity experimental site, Sourhope, UK, in August 1999. The objective of this investigation was to determine the magnitude of pulse-derived C incorporation into a typical upland plant community. To achieve this, the SID system was deployed to pulse-label vegetation with CO(2) enriched with (13)C (50 atom %) at ambient concentrations ( approximately 350 ppm) on two consecutive days in August 1999. Samples of headspace CO(2), shoot and root were taken on four occasions over a period of 28 days after (13)C labelling. These materials were then prepared for (13)C/(12)C ratio determination by continuous-flow/combustion/isotope ratio mass spectrometry (CF-C-IRMS). Results showed that pulse derived CO(2)-C was assimilated at a rate of 128 +/- 32 microg g shoot-C hour(-1). Dynamic samplings showed that pulse-derived (13)C concentrations in the labelled plant tissues declined by 77.4 +/- 6% after 48 hours. The rapid decline in (13)C concentrations in plant matter was the result of C loss from the plant in the form of respired CO(2) and root exudates, and dilution by subsequent unlabelled C assimilates. This novel system offers considerable potential for in situ tracer investigations.  相似文献   

13.
Synthesis of Sn(IV) and La(III) based nanocomposites has been effectuated. According to the data obtained by XRD and TPR-H2 methods, it is supposed that La in nanocompites is located in amorphous La2Sn2O7 segregation. The effect of La(III) on the adsorption properties of SnO2 surface and concentration of chemisorbed oxygen was determined. Sensor properties of obtained materials towards 10 ppm of CO in air were studied by in situ DC conductance measurements. It is shown that La introduction allows to increase sensor response of SnO2 during CO detection in air.  相似文献   

14.
A continuous-flow isotope-ratio mass spectrometer (CF-IRMS, custom-made GasBenchII and Delta(plus)Advantage, ThermoFinnigan) was installed on a grassland site and interfaced with a closed-path infrared gas analyser (IRGA). The CF-IRMS and IRGA were housed in an air-conditioned travel van. Air was sampled at 1.5 m above the 0.07-m tall grassland canopy, drawn through a 17-m long PTFE tube at a rate of 0.25 L s(-1), and fed to the IRGA and CF-IRMS in series. The IRMS was interfaced with the IRGA via a stainless steel capillary inserted 0.5 m into the sample air outlet tube of the IRGA (forming an open split), a gas-tight pump, and a sample loop attached to the eight-port Valco valve of the continuous-flow interface. Air was pumped through the 0.25-mL sample loop at 10 mL s(-1) (a flushing frequency of 40 Hz). Air samples were analysed at intervals of approx. 2.8 min. Whole system precision was tested in the field using air mixed from pure CO2 and CO2-free air by means of mass flow controllers. The standard deviation of repeated single measurements was 0.21-0.07 per thousand for delta13C and 0.34-0.14 per thousand for delta18O of CO2 in air with mixing ratios ranging between 200-800 micromol mol(-1). The CO2 peak area measured by the IRMS was proportional to the CO2 mixing ratio (r2 = 1.00), allowing estimation of sample air CO2 mixing ratio from IRMS data. A 1-day long measurement cycle of CO2, delta13C and delta18O of air sampled above the grassland canopy was used to test the system for Keeling plot applications. Delta18O exhibited a clear diurnal cycle (4 per thousand range), but short-term (1-h interval) variability was small (average SD 0.38 per thousand). Yet, the correlation between delta18O and CO2 mixing ratio was relatively weak, and this was true for both the whole data set and 1-h subsets. Conversely, the delta13C of all 541 samples measured during the 25.2-h interval fitted well the Keeling regression (r2 = 0.99), yielding an intercept of -27.40 per thousand (+/-0.07 per thousand SE). Useful Keeling regressions (r2 > 0.9, average r2 = 0.96) also resulted from data collected over 1-h intervals of the 12-h long twilight and dark period. These indicated that 13C content of ecosystem respiration was approx. constant near -27.6 per thousand. The precision of the present system is similar to that of current techniques used in ecosystem studies which employ flask sampling and a laboratory-based CF-IRMS. Sampling (and measurement) frequency is greatly increased relative to systems based on flask sampling, and sampling time (0.025 s per sample) is decreased. These features increase the probability for sampling the entire CO2 range which occurs in a given time window. The system obviates sample storage problems, greatly minimises handling needs, and allows extended campaigns of high frequency sampling and analysis with minimal attendance.  相似文献   

15.
Reaction kinetics measurements of the water-gas shift reaction were carried out at 373 K on Pt/Al2O3 in vapor phase to investigate the effects of CO, H2, and H2O partial pressures. Results of in situ ATR-IR studies conducted in vapor phase under similar conditions suggest that the Pt surface coverage by adsorbed CO is high (approximately 90% of the saturation coverage), leading to a negligible effect of the CO pressures on the rate of reaction. The negative reaction order with respect to the H2 pressure is caused by the increased coverage of adsorbed H atoms, and the fractional positive order with respect to the water pressure is consistent with non-equilibrated H2O dissociation on Pt. Results of in situ ATR-IR studies carried out at 373 K show that the presence of liquid water leads to a slight decrease in the Pt surface coverage by adsorbed CO (approximately 80% of the saturation coverage) when the CO partial pressure is the same as in the vapor-phase studies. The rate of the WGS reaction in the presence of liquid water is comparable to the rate under complete vaporization conditions when other factors (such as CO partial pressure) are held constant. Reaction kinetics measurements of methanol reforming were carried out at 423 K over a total pressure range of 1.36-5.84 bar. In situ ATR-IR studies were conducted at 423 K to determine the Pt surface coverage by adsorbed CO in completely vaporized methanol feeds and in aqueous methanol solutions. The decomposition of methanol is found to be slower during the reforming of methanol in liquid phase than in vapor phase, which leads to a lower rate of hydrogen production in liquid phase (0.08 min(-1) at 4.88 bar) than in vapor phase (0.23 min(-1) at 4.46 bar). The lower reaction order with respect to methanol concentration observed for vapor-phase versus liquid-phase methanol reforming (0.2 versus 0.8, respectively) is due to the higher extent of CO poisoning on Pt for reforming in vapor phase than in liquid phase, based on the higher coverage by adsorbed CO observed in completely vaporized methanol feeds (55-60% of the saturation coverage) than in aqueous methanol feed solutions (29-40% of the saturation coverage).  相似文献   

16.
Remote sensing of CO(2) requires high-fidelity reference data of spectral line parameters to be successful. The 6360 cm(-1) region is commonly used by satellites, field campaigns, and point-source gas sensors because it contains well-characterized and relatively isolated transitions of appropriate line strengths for atmospheric applications. However, the presence of gases other than CO(2), N(2), and O(2) can be a source of uncertainty for atmospheric measurements. Near 6360 cm(-1), there are numerous H(2)O and HDO transitions. Water makes up approximately 1-4% of Earth's lower atmosphere and can interfere with remote sensing measurements by (1) appearing as a direct spectral interference or (2) acting as a foreign broadener for CO(2) lines. The primary goal of this work was to quantify H(2)O broadening of CO(2) through precision spectroscopy measurements on the R16e transition at 6359.967 cm(-1) and its two nearest neighbors. A secondary goal was to assess the accuracy of H(2)O reference line parameters in the HITRAN 2008 database for spectrally removing typical levels of moisture from air samples containing approximately 400 ppm of CO(2).  相似文献   

17.
The application of (13)C/(12)C in ecosystem-scale tracer models for CO(2) in air requires accurate measurements of the mixing ratios and stable isotope ratios of CO(2). To increase measurement reliability and data intercomparability, as well as to shorten analysis times, we have improved an existing field sampling setup with portable air sampling units and developed a laboratory setup for the analysis of the delta(13)C of CO(2) in air by isotope ratio mass spectrometry (IRMS). The changes consist of (a) optimization of sample and standard gas flow paths, (b) additional software configuration, and (c) automation of liquid nitrogen refilling for the cryogenic trap. We achieved a precision better than 0.1 per thousand and an accuracy of 0.11 +/- 0.04 per thousand for the measurement of delta(13)C of CO(2) in air and unattended operation of measurement sequences up to 12 h.  相似文献   

18.
To obtain accurate values of delta(13)C(CO(2)) and delta(18)O(CO(2)) on environmental CO(2) by mass spectrometry, the raw isotope data must be corrected for the isobaric N(2)O contribution. This is one of the analytical problems limiting inter-laboratory delta(13)C(CO(2)) data consistency. The key parameter, the N(2)O relative ionisation efficiency (E(N2O)), cannot be determined with sufficient accuracy by direct measurements of pure N(2)O. The determination of (E(N2O)) by analyses on N(2)O--CO(2) mixtures of known isotope composition and mixing proportions has been recently suggested. In this work we propose a new method of N(2)O correction which uses the m/z 30 signal as a measure of the N(2)O/CO(2) ratio, so that determinations of (E(N2O)) and N(2)O content are not required. The method uses the fact that fragment-ion spectra of N(2)O and CO(2) are very specific. The formalism of the correction is considered. Various tests demonstrate that the new method is robust, stable and easy to implement in practice. The effective value (E(N2O)) (the key parameter for the new correction) has to be calibrated on known N(2)O--CO(2) mixtures by measuring (30)R signals only. The method accuracy we presently achieved is around 2.5% and any error which appears to come mostly from our N(2)O--CO(2) mixture preparation. Based on our tests and error considerations, the error of the proposed method that may be achieved is as low as +/-1.5% (relative to the correction magnitude). For tropospheric CO(2) this means +/-0.003 per thousand and +/-0.005 per thousand for delta(13)C(CO(2)) and delta(18)O(CO(2)), respectively. The proposed method may be valuable for small samples where no separate N(2)O determinations are available (e.g. ice core samples and CF-IRMS measurements) as well as for determination of (E(N2O)) and testing the 'traditional' N(2)O correction based on mass balance calculations.  相似文献   

19.
A new technique for measuring CO(2) concentration in air samples, based on mass spectrometry, is described as an alternative to the common gas chromatographic method. Using a dual inlet isotope ratio mass spectrometer (IRMS), the ratio of the abundances of the m/z peaks 44 and 28 is determined. The precision of measurements (standard deviation <3 ppmv) is generally as good as the analysis with gas chromatography for small air samples (<1 ml STP of air). A major advantage of this new method is the possibility of parallel elemental and isotopic measurements of many air components. The technique is further improved by new wide mass range mass spectrometers allowing simultaneous intensity measurements of several m/z values between 28 and 44, resulting in an uncertainty of <0.5 ppm. The precision is somewhat limited by the production of N(2)O and NO(2) from N(2) and O(2) in the ion source, which accounts for about half of the signal strength at m/z 44. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

20.
Procedures were proposed for the determination of impurities of permanent gases (H2, O2, Ar, N2, and CO), carbon dioxide, and hydrocarbons in high-purity monosilane by gas chromatography with detection limits of 1–3 ppm, 2 ppm, and 0.02–0.04 ppm, respectively, which are lower by 1–2 orders of magnitude than those published in the literature. The procedures make it possible to check the compliance of the purity of monosilane with present standards of microelectronics (TU 48-0513-057.0-91).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号