首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 219 毫秒
1.
The partitioning of acetylspiramycin was carried out in an aqueous two-phase system (ATPS) formed by a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoraborate, [Bmim]BF4) and NaH2PO4. This ATPS is a simple, non-toxic and effective sample pretreatment technique, which was developed for the simultaneous separation, enrichment and rapid analysis of acetylspiramycin coupled with molecular fluorescence spectrophotometry. Analysis of the liquid-liquid equilibrium of [Bmim]BF4-salt ATPS demonstrated that the salting-out ability of different salts may be related to the Gibbs energy of hydration of the ions. The effects of types of salts, concentration of NaH2PO4, and temperature were analysed. Under optimum conditions, the average extraction efficiency and partition coefficient were 90.14% and 91.1, respectively. Thermodynamic functions provide some information about the molecular mechanism involved in acetylspiramycin transfer to the top phase, suggesting an important acetylspiramycin-[Bmim]BF4 interaction. The method yielded a linear range in the concentration from 1.0 to 10.0 μg mL−1 of acetylspiramycin, and the limit of detection was 0.02 μg mL−1. This method could be successfully applied for the analysis of acetylspiramycin in lake water, river water and groundwater. The proposed extraction technique appears to be suitable as a first step for the separation of macrolide antibiotics from real aqueous environments.  相似文献   

2.
In the study, a fast and selective method based on magnetic separation has been developed for the extraction of nicotine from human plasma using magnetic strong cation exchange (MSCX) resins as adsorbent. MSCX resins were prepared using hydrophobic Fe3O4 magnetite as magnetically susceptible component, styrene and acrylic acid as polymeric matrix components, and acetyl sulfonate as the sulfonation agent. The extraction procedure was carried out in a single step by stirring the mixture of diluted plasma sample and MSCX resins in the vortex for 5 min. Then, the resins with adsorbed nicotine were separated from the sample matrix by applying an appropriate magnetic field. Main factors affecting the extraction of nicotine such as the amount of MSCX resins, pH value of the extraction solvent, extraction time, and washing and eluting conditions were optimized. The nicotine eluted from the resins was determined by liquid chromatography–tandem mass spectrometry. The calibration curve obtained by analyzing matrix-matched standards shows excellent linear relationship (r 2 = 0.9998) in the concentration range of 10–2,500 ng mL−1. The limit of detection and quantification obtained are 2.9 and 9.7 ng mL−1, respectively. The relative standard deviations of intra- and inter-day obtained are in the range of 1.9–6.9% and 2.5–7.8% with the recoveries ranging from 78.7% to 99.1%. The proposed method was successfully applied to determine nicotine in human plasma phlebotomized from ten male smokers. Nicotine was detectable with the contents ranging from 44.4 to 221.9 ng mL−1 in five samples.  相似文献   

3.
An ionic liquid-salt aqueous two-phase system (ILATPS) based on the hydrophilic ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate ([Bmim]BF4) and inorganic salt was developed for direct separation and analysis of macrolide antibiotics coupled with molecular fluorescence spectrophotometry. Liquid–liquid equilibria of [Bmim]BF4-salt aqueous two-phase systems were studied for different salts and temperatures. It was found that the salting-out ability of different salts may be related to the Gibbs energy of hydration of the ions, and the two-phase area was expanded with a decrease in temperature. The partition coefficients as well as extraction efficiencies of azithromycin and mydecamycin in [Bmim]BF4-salt aqueous two-phase system were influenced by the types of salts, concentration of salt, and the extracting temperature. Under the optimum conditions, the average partition coefficient of azithromycin in [Bmim]BF4-Na2CO3 ILATPS was 162, and that of mydecamycin in [Bmim]BF4- NaH2PO4 ILATPS was 90.9. This method has been satisfactorily applied to the determination of azithromycin and mydecamycin in real water samples with detection limits of 0.059 µg mL?1 and 0.019 µg mL?1. This extraction method is a simple, non-toxic and effective sample pretreatment technique with promise also for the separation of other small biomolecules.  相似文献   

4.
A liquid chromatographic–mass spectrometric (LC–MS) method has been developed and validated for simultaneous determination of dehydroevodiamine and limonin from Evodia rutaecarpa in rat plasma. After addition of the internal standard, domperidone, plasma samples were extracted by liquid–liquid extraction with ethyl acetate and separated on an Apollo C18 column (250 mm × 4.6 mm, 5 μm), with methanol–0.01% formic acid water (60:40, v/v) as mobile phase, within a runtime of 12.0 min. The analytes were detected without interference in the selected ion monitoring (SIM) mode with positive electrospray ionization. The linear range was 1.0–500 ng mL−1 for dehydroevodiamine and 2.0–1,000 ng mL−1 for limonin, with lower limits of quantitation of 1.0 and 2.0 ng mL−1, respectively. Intra-day and inter-day precision were within 6.0% and 10.9%, respectively, for both analytes, and the accuracy (relative error, RE, %) was less than 4.8% and 6.5%, respectively. The validated method was successfully applied to a comparative pharmacokinetic study of dehydroevodiamine and limonin in rat plasma after oral administration of dehydroevodiamine, limonin, and an aqueous extract of Evodiae fructus. The results indicated there were obvious differences between the pharmacokinetic behavior after oral administration of an aqueous extract of Evodiae fructus compared with single substances.  相似文献   

5.
A multianalyte lateral-flow immunochromatographic technique using colloidal gold-labeled polyclonal antibodies was developed for the rapid simultaneous detection of clenbuterol and ractopamine. The assay procedure could be accomplished within 5 min, and the results of this qualitative one-step assay were evaluated visually according to whether test lines appeared or not. When applied to the swine urines, the detection limit and the half maximal inhibitory concentration (IC50) of the test strip under an optical density scanner were calculated to be 0.1 ± 0.01 ng mL−1 and 0.1 ± 0.01 ng mL−1, 0.56 ± 0.08 ng mL−1, and 0.71 ± 0.06 ng mL−1, respectively, the cut-off levels with the naked eye of 1 ng mL−1 and 1 ng mL−1 for clenbuterol and ractopamine were observed. Parallel analysis of swine urine samples with clenbuterol and ractopamine showed comparable results obtained from the multianalyte lateral-flow test strip and GC-MS. Therefore, the described multianalyte lateral-flow test strip can be used as a reliable, rapid, and cost-effective on-site screening technique for the simultaneous determination of clenbuterol and ractopamine residues in swine urine.   相似文献   

6.
A fast and sensitive liquid chromatography–mass spectrometry method was developed for the determination of ursolic acid (UA) in rat plasma and tissues. Glycyrrhetinic acid was used as the internal standard (IS). Chromatographic separation was performed on a 3.5 μm Zorbax SB-C18 column (30 mm × 2.1 mm) with a mobile phase consisting of methanol and aqueous 10 mM ammonium acetate using gradient elution. Quantification was performed by selected ion monitoring with (m/z) 455 for UA and (m/z) 469 for the IS. The method was validated in the concentration range of 2.5 − 1470 ng mL−1 for plasma samples and 20 − 11760 ng g−1 for tissue homogenates. The intra- and inter-day assay of precision in plasma and tissues ranged from 1.6% to 7.1% and 3.7% to 9.0%, respectively, and the intra- and inter-day assay accuracy was 84.2 − 106.9% and 82.1 − 108.1%, respectively. Recoveries in plasma and tissues ranged from 83.2% to 106.2%. The limits of detections were 0.5 ng mL−1 or 4.0 ng g−1. The recoveries for all samples were >90%, except for liver, which indicated that ursolic acid may metabolize in liver. The main pharmacokinetic parameters obtained were T max = 0.42 ± 0.11 h, C max = 1.10 ± 0.31 μg mL−1, AUC = 1.45 ± 0.21 μg h mL−1 and K a = 5.64 ± 1.89 h−1. The concentrations of UA in rat lung, spleen, liver, heart, and cerebellum were studied for the first time. This method is validated and could be applicable to the investigation of the pharmacokinetics and tissue distribution of UA in rats.  相似文献   

7.
A miniaturized dispersive liquid–liquid microextraction (DLLME) procedure coupled to liquid chromatography (LC) with fluorimetric detection was evaluated for the preconcentration and determination of thiamine (vitamin B1). Derivatization was carried out by chemical oxidation of thiamine with 5 × 10−5 M ferricyanide at pH 13 to form fluorescent thiochrome. For DLLME, 0.5 mL of acetonitrile (dispersing solvent) containing 90 μL of tetrachloroethane (extraction solvent) was rapidly injected into 10 mL of sample solution containing the derivatized thiochrome and 24% (w/v) sodium chloride, thereby forming a cloudy solution. Phase separation was carried out by centrifugation, and a volume of 20 μL of the sedimented phase was submitted to LC. The mobile phase was a mixture of a 90% (v/v) 10 mM KH2PO4 (pH 7) solution and 10% (v/v) acetonitrile at 1 mL min−1. An amide-based stationary phase involving a ligand with amide groups and the endcapping of trimethylsilyl was used. Specificity, linearity, precision, recovery, and sensitivity were satisfactory. Calibration graph was carried out by the standard additions method and was linear between 1 and 10 ng mL−1. The detection limit was 0.09 ng mL−1. The selectivity of the method was judged from the absence of interfering peaks at the thiamine elution time for blank chromatograms of unspiked samples. A relative standard deviation of 3.2% was obtained for a standard solution containing thiamine at 5 ng mL−1. The esters thiamine monophosphate and thiamine pyrophosphate can also be determined by submitting the sample to successive acid and enzymatic treatments. The method was applied to the determination of thiamine in different foods such as beer, brewer’s yeast, honey, and baby foods including infant formulas, fermented milk, cereals, and purees. For the analysis of solid samples, a previous extraction step was applied based on an acid hydrolysis with trichloroacetic acid. The reliability of the procedure was checked by analyzing a certified reference material, pig’s liver (CRM 487). The value obtained was 8.76 ± 0.2 μg g−1 thiamine, which is in excellent agreement with the certified value, 8.6 ± 1.1 μg g−1.  相似文献   

8.
In the present work, a high-performance liquid chromatography–tandem mass spectrometry method has been developed for the residue analysis of chloramphenicol (CAP) in several food matrices. Following the addition of D5-CAP as internal standard, egg, honey, and milk were extracted and cleaned by means of solid-phase extraction, utilizing multi-walled carbon nanotubes as sorbent. The extracts were separated on a Halo fused-core C18 column (50 mm × 2.1 mm, 2.7 μm) and quantified by a 4000 Q-trap mass spectrometer equipped with a TurboIonSpray™ interface using electrospray ionization and multiple-reaction monitoring mode. The method validation was performed according to the criteria of Commission Decision 2002/657/EC. The decision limit (CCα) and detection capability (CCβ) of CAP in milk were calculated for m/z 320.8 > 151.9. Due to the existence of slight signal suppression, quantification was performed by matrix-matched calibration curves, ranging from 0.1 to 100 ng mL−1, with regression coefficients of 0.9993, 0.9998, and 0.9997 for egg, honey, and milk, respectively. Mean recoveries of the CAP ranged from 95.8% to 102.3%, with the corresponding intra- and inter-day variation (relative standard deviation) less than 7.13% and 8.89%, respectively. The limit of detection and limit of quantification of the method were also reported. This method successfully applied to several food matrixes (egg, honey, and milk) and can serve as a monitoring tool to avoid unacceptable levels of residues of CAP entering the food chain.  相似文献   

9.
The ionic liquid, as a green solvent, has several advantages over the organic solvents in traditional liquid-liquid extraction. Aqueous two-phase system (ATPS) consisting of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoraborate, [Bmim]BF4) and Na2CO3, which is a novel, simple, non-toxic and effective sample pretreatment technique coupled with molecular fluorescence spectrophotometry, was developed for the simultaneous separation, enrichment and rapid analysis of roxithromycin. The extraction yield of roxithromycin in [Bmim]BF4-Na2CO3 aqueous two-phase system is influenced by the types of salts, concentrations of Na2CO3 and [Bmim]BF4, as well as the extracting temperature. Under the optimum conditions, the average extraction efficiency is up to 90.7%. The mechanism of ionic liquid-salt ATPS formation was discussed by hydration theory, and the extraction mechanism of the [Bmim]BF4-salt ATPS was investigated by FT-IR spectroscopy and UV-vis spectroscopy. The results demonstrate that no chemical (bonding) interactions are observed between ionic liquid and roxithromycin, while the nature properties of the roxithromycin are not altered. This method was practical when applied to the analysis of roxithromycin in real water samples with the detection limit of 0.03 μg mL−1, relative standard deviation (RSD) of 1.9% (n = 13), and linear ranges of 1.00-20.00 μg mL−1. The proposed extraction technique will be promising in the separation of other small biomolecules.  相似文献   

10.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed in plate to detect three sulfonamide residues (sulfamerazine (SMR), sulfadimetoxine (SDM), and sulfadiazine (SDZ)) in gilthead sea bream (Sparus aurata) samples. Different extraction methodologies—using methanol/water 1:1 (v/v) + ethylene diamine tetraacetic acid (EDTA) 0.5% (m/v), acetonitrile, phosphate-buffered saline (PBS) 10 mmol L−1 pH 7 and acetate buffer 100 mmol L−1 pH 5—and cleanup steps, based on solid-phase extraction (C18, SCX, Si) or liquid extraction with hexane, were assayed. As optimum, a fast and simple method using acetonitrile was selected to extract the sulfonamide residues from the edible muscle of fish. Due to matrix effects, a standard addition calibration curve in fish extract is necessary for quantification purposes. Sulfonamide-free samples were spiked at different concentration levels (between 30 and 90 ng g−1, 5–15 ng mL−1 in plate) and average recoveries (n = 8), ranging from 71% to 95%, 65% to 79%, and 72% to 95%, were obtained for SMR, SDM, and SDZ, respectively. The assay detection limits for these antibiotics were lower than 100 μg kg−1 (maximum residue level established by the European Union). The accuracy was evaluated by spiking blank fish extracts at different concentrations (10–40 ng mL−1, 5–20 ng mL−1 in plate), and the relative errors ranged between ±20%. Finally, in order to confirm the utility of the developed ELISA as a screening methodology, fish samples from different supermarkets were analyzed, and results were compared with those obtained by a validated high-performance liquid chromatography (HPLC) method. The correlation between the results obtained by both ELISA and HPLC methods is satisfactory.   相似文献   

11.
The performance of the dispersive liquid–liquid microextraction (DLLME) technique for the determination of eight UV filters and a structurally related personal care species, benzyl salicylate (BzS), in environmental water samples is evaluated. After extraction, analytes were determined by gas chromatography combined with mass spectrometry detection (GC-MS). Parameters potentially affecting the performance of the sample preparation method (sample pH, ionic strength, type and volume of dispersant and extractant solvents) were systematically investigated using both multi- and univariant optimization strategies. Under final working conditions, analytes were extracted from 10 mL water samples by addition of 1 mL of acetone (dispersant) containing 60 μL of chlorobenzene (extractant), without modifying either the pH or the ionic strength of the sample. Limits of quantification (LOQs) between 2 and 14 ng L−1, inter-day variability (evaluated with relative standard deviations, RSDs) from 9% to 14% and good linearity up to concentrations of 10,000 ng L−1 were obtained. Moreover, the efficiency of the extraction was scarcely affected by the type of water sample. With the only exception of 2-ethylhexyl-p-dimethylaminobenzoate (EHPABA), compounds were found in environmental water samples at concentrations between 6 ± 1 ng L−1 and 26 ± 2 ng mL−1.  相似文献   

12.
Chitosan resin functionalized with 3,4-dihydroxy benzoic acid (CCTS-DHBA resin) was used as a packing material for flow injection (FI) on-line mini-column preconcentration in combination with inductively coupled plasma-atomic emission spectrometry (ICP-AES) for the determination of trace elements such as silver, bismuth, copper, gallium, indium, molybdenum, nickel, uranium, and vanadium in environmental waters. A 5-mL aliquot of sample (pH 5.5) was introduced to the minicolumn for the adsorption/preconcentration of the metal ions, and the collected analytes on the mini-column were eluted with 2 M HNO3, and the eluates was subsequently transported via direct injection to the nebulizer of ICP-AES for quantification. The parameters affecting on the sensitivity, such as sample pH, sample flow rate, eluent concentration, and eluent flow rate, were carefully examined. Alkali and alkaline earth metal ions commonly existing in river water and seawater did not affect the analysis of metals. Under the optimum conditions, the method allowed the determination of metal ions with detection limits of 0.08 ng mL−1 (Ag), 0.9 ng mL−1 (Bi), 0.07 ng mL−1 (Cu), 0.9 ng mL−1 (Ga), 0.9 ng mL−1 (In), 0.08 ng mL−1 (Mo), 0.09 ng mL−1 (Ni), 0.9 ng mL−1 (U), and 0.08 ng mL−1 (V). By using 5 mL of sample solution, the enrichment factor and collection efficiency were 8–12 fold and 96–102%, respectively, whereas the sample throughput was 7 samples/hour. The method was validated by determining metal ions in certified reference material of river water (SLRS-4) and nearshore seawater (CASS-4), and its applicability was further demonstrated to river water and seawater samples.  相似文献   

13.
A novel experimental methodology based on a Prussian blue (PB) and gold nanoparticles (AuNPs) modified carbon ionic liquid electrode (CILE) was developed for use in a label-free amperometric immunosensor for the sensitive detection of human immunoglobulin G (HIgG) as a model protein. The CILE was fabricated by using the ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate as binder. Controllable electrodeposition of PB on the surface of the CILE and coating with 3-aminopropyl triethylene silane (APS) formed a film with high electronic catalytic activity and large surface area for the assembly of AuNPs and further immobilization of HIgG antibody. The electrochemistry of the formed nanocomposite biofilm was investigated by electrochemical techniques including cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy. The HIgG concentration was measured through the decrease of amperometric responses in the corresponding specific binding of antigen and antibody. The decreased differential pulse voltammetric values were proportional to the HIgG concentration in two ranges, 0.05–1.25 ng mL−1 and 1.25–40 ng mL−1, with a detection limit of 0.001 ng mL−1 (S/N = 3). This electrochemical immunoassay combined the specificity of the immunological reaction with the sensitivity of the AuNPs, ionic liquid, and PB amplified electrochemical detection and would therefore be valuable for clinical immunoassays.  相似文献   

14.
A micro-solid phase extraction technique was developed using a novel polypyrrole-polyamide nanofiber sheet, fabricated by electrospinning method. The applicability of the new nanofiber sheet was examined as an extracting medium to isolate malathion as a model pesticide from aqueous samples. Solvent desorption was subsequently performed in a microvial, and an aliquot of extractant was injected into gas chromatography–mass spectrometry. Various parameters affecting the electrospinning process including monomer concentration, polyamide content, applied voltage, and electrospinning time were examined. After fabricating the most suitable preparation conditions, influential parameters on the extraction and desorption processes were optimized. The developed method proved to be rather convenient and offers sufficient sensitivity and good reproducibility. The limit of detection (S/N = 3) and limit of quantification (S/N = 10) of the method under optimized conditions were 50 and 100 ng L−1, respectively. The relative standard deviation at concentration level of 1 ng mL−1 was 2% (n = 3). The calibration curve of analyte showed linearity in the range of 0.1–1 ng mL−1 (R 2 = 0.9975). The developed method was successfully applied to tap and Zayanderood river water samples, while the relative recovery percentages of 98% and 96% were obtained, respectively. The whole procedure showed to be conveniently applicable and quite easy to be manipulated.  相似文献   

15.
A novel approach for the rapid analysis of ochratoxin A (OTA) in wine samples is presented. Mycotoxin was extracted and concentrated from matrix using dispersive liquid–liquid microextraction (DLLME). The final extract is analyzed by liquid chromatography coupled to positive electrospray ionization tandem mass spectrometry employing [2H5]-ochratoxin A as internal standard. Some important parameters, such as the nature and volume of extraction solvent and dispersive solvent, and salt effect were investigated and optimized to achieve the best extraction efficiency and higher enrichment factor. Under the optimum extraction condition, the method provided enrichment factor around 80 times and showed a high sensitivity with method detection and quantification limits of 0.005 and 0.015 ng mL−1, respectively. To test the accuracy of the analytical procedure, the optimized method was applied to the analysis of reference material T1755 (naturally contaminated white wine), with excellent results (accuracy of 103%) and showing a good precision with a CV (n = 6) of 5.8%. The proposed method, which is demonstrated to be quick, cheap, accurate and highly selective, was successfully applied to the analysis of Italian wines.  相似文献   

16.
A novel method for the determination of proteins at nanogram levels was proposed based on the decrease of resonance light scattering (RLS) signal resulting from the interaction of dibromo-o-nitrophenylfluorone (DBONPF)-sodium lauroyl glutamate (SLG) with proteins. At pH 2.97, the decrease RLS intensity was proportional to the concentration of proteins in the range of nanogram levels with 3σ detection limits being 3.4 ng mL−1 for bovine serum albumin (BSA), 1.7 ng mL−1 for human serum albumin (HSA), 4.1 ng mL−1 for γ-globulin (γ-IgG), 4.4 ng mL−1 for egg albumin, 6.2 ng mL−1 for pepsin (Pep) and 3.7 ng mL−1 for α-chymotrypsin (Chy). The method is no protein-to-protein variability, simple, rapid, practical and relatively free from interference from coexisting substance, as well as much more sensitive than most of the reported methods. The proposed method was successfully applied to determine total protein in human serum samples.  相似文献   

17.
Antidepressants are widely used for the treatment of psychiatric disorders and therefore their monitoring in biological fluids is quite important taking into account that they can produce dangerous biochemical imbalances in toxic doses. A method for the determination of antidepressants in urine samples is presented using solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection. Home-made cartridges containing 30 mg multiwall carbon nanotubes are employed for isolation of the analytes from the sample, allowing also the preconcentration of the analytes prior to the HPLC analysis. Chromatographic separation was achieved in a reversed-phase C8 column using the ionic liquid 1-butyl-3-methylimidazolium trifluoromethanesulfonate as silanol activity suppressor, which enhances peak symmetry and chromatographic resolution. Limits of detection were 12.3 ng mL−1 for trazodone and 90.1 ng mL−1 for fluoxetine. The repeatability of the proposed method expressed as RSD (n = 11) varied between 3.4% (fluoxetine) and 5.0% (desipramine and mianserine). Thus, the method is suitable for the therapeutic monitoring of antidepressants in urine samples.  相似文献   

18.
This work describes an effective, low solvent consumption and affordable sample preparation approach for the determination of eight UV filters in surface and wastewater samples. It involves sorptive extraction of target analytes in a disposable, technical grade silicone disc (5 mm diameter × 0.6 mm thickness) followed by organic solvent desorption, large volume injection (LVI), and gas chromatography-mass spectrometry determination. Final working conditions involved overnight extraction of 100-mL samples, containing 10% of methanol, followed by analytes desorption with 0.2 mL of ethyl acetate. The method provides linear responses between the limits of quantification (from 0.003 to 0.040 ng mL−1) and 10 ng mL−1, an intra-day precision below 13%, and low matrix effects for surface, swimming pool, and treated sewage water samples. Moreover, the extraction yields provided by silicone discs were in excellent agreement with those achieved using polydimethylsiloxane-covered stir bars. Several UV filters were found in surface and sewage water samples, with the maximum concentrations corresponding to octocrylene.  相似文献   

19.
Hongmei Jiang  Bin Hu 《Mikrochimica acta》2008,161(1-2):101-107
A new method of direct single-drop microextraction combined with electrothermal atomic absorption spectrometry (ETAAS) is presented for the determination of trace Cd and Pb with dithizone (H2DZ) as chelating reagent. Factors influencing the microextraction efficiency and determination, such as pH, microdrop volume, stirring rate, extraction time were evaluated. Under the optimized experimental conditions, the detection limits of the method are 2 and 90 pg mL−1 for Cd and Pb, and the relative standards deviations for 0.5 ng mL−1 Cd and 10 ng mL−1 Pb are 11 and 12.8%. After 10 min of extraction, the enrichment factors for Cd and Pb are 118 and 90, respectively. The results for the determination of Cd and Pb in tap water, spring water, river water, pond water, lake water and spiked water samples demonstrate the accuracy, recovery and applicability of the method. An environmental water certified reference material (GSBZ 50009-88) was analyzed, and the determined values are in a good agreement with the certified values. Correspondence: Bin Hu, Department of Chemistry, Wuhan University, Wuhan 430072, P.R. China  相似文献   

20.
A liquid chromatographic method has been developed, in combination with the multivariate curve resolution-alternating least squares algorithm (MCR-ALS), for the simultaneous determination of marker pteridines in urine samples. A central composite design has been applied to optimize the factors influencing the separation (buffer concentration, buffer pH, flow rate, oven temperature, mobile-phase composition). A set of 15 calibration samples were randomly prepared, in a concentration range of 0.5–10.5 ng mL−1 for neopterin, biopterin, and pterin; 4.0–8.0 ng mL−1 for xanthopterin; and 0.5–4.5 ng mL−1 for isoxanthopterin. The validation was carried out with fortified urine samples from healthy adults. The optimized conditions were a mobile-phase composition of 10 mM citric buffer at pH 5.44 and acetonitrile (94.5/5.5, v/v), a flow rate of 1.0 mL min−1, and an oven temperature of 25 °C. The detection system consisted of a fast-scanning spectrofluorimeter, which allows obtaining of second-order data matrices containing the fluorescence intensity as a function of retention time and emission wavelength. In this work, MCR-ALS was used to cope with coeluting interferences, on account of the second-order advantage inherent to this algorithm which, in addition, is able to handle data sets deviating from trilinearity, like the high-performance liquid chromatography data analyzed in the present report. The developed approach enabled us to determine five pteridines, some of them with overlapped profiles, reducing the experimental time and reagent consumption. Ratio values for pteridines/creatinine in urine, for infected children with different pathologies, are reported in this work.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号