1.

A sample preparation method for aflatoxin M1 (AFM1) determination in raw milk was optimized following the quick, easy, cheap, effective, rugged and safe (QuEChERS) strategy, as an alternative to the classic immunoaffinity column clean-up (IAC). The method was adapted to address the complexity of the milk matrix, and to be suitable for final determination by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC–MS/MS). This approach proved also to be compatible with the simultaneous extraction of pesticide residues and other contaminants (mycotoxins). Regarding AFM1, satisfactory linearity was achieved and appropriate sensitivity was maintained, using matrix-matched calibration to compensate for the heavy ion suppression. The accuracy and precision, which were determined through recovery studies, were 70–95 %, with the relative standard deviation below 15 % in all of the cases. The limit of detection (LOD, 0.002 μg L−1) and limit of quantification (0.007 μg L−1) are compatible with current worldwide regulations (maximum levels of 0.5 and 0.05 μg L−1). The procedure was applied to samples that were naturally contaminated with a range of AFM1 at LOQ–0.187 μg L−1, with comparable results to IAC clean-up, which was employed as a reference method. Therefore, AFM1 determination in raw milk by UHPLC–MS/MS detection through the present QuEChERS extraction constitutes a reliable alternative to IAC clean-up and exhibits advantages related to cost, accessibility of materials and simplicity of operation.

  相似文献   

2.
A novel, facile and inexpensive solid phase extraction (SPE) method using ethylene glycol bis-mercaptoacetate modified 3-(trimethoxysilyl)-1-propanethiol grafted Fe3O4 nanoparticles coupled with spectrofluorimetric detection was proposed for determination of aflatoxin M1 (AFM1) in liquid milk samples. The method uses the advantage fluorescence enhancement by β-cyclodexterin complexation of AFM1 in 12% (v/v) acetonitrile–water and the remarkable properties of Fe3O4 nanoparticles namely high surface area and strong magnetization were utilized to achieve high enrichment factor (57) and satisfactory extraction recoveries (91–102%) using only 100 mg of magnetic adsorbent. Furthermore, fast separation time of about 15 min avoids many time-consuming column-passing procedures of conventional SPE. The main factors affecting extraction efficiency including pH value, desorption conditions, extraction/desorption time, sample volume, and adsorbent amount were evaluated and optimized. Under the optimal conditions, a wide linear range of 0.04–8 ng mL−1 with a low detection limit of 0.015 ng mL−1 was obtained. The developed method was applied for extraction and preconcentration of AFM1 in three commercially available milk samples and the results were compared with the official AOAC method.  相似文献   

3.
A flow-injection immunoassay (FI-IA) method with amperometric detection for aflatoxin M1 (AFM1) determination in milk has been developed. The first step consists in an incubation of the sample containing AFM1 (Ag) with fixed amounts of anti-AFM1 antibody (Ab) and of the tracer (Ag*, AFM1 covalently coupled to HRP) until equilibrium is reached. In this mixture a competition occurs between Ag and Ag* for the Ab. The mixture is then injected into a flow system where the separation of the free tracer (Ag*) and the antibody-bound tracer (AbAg*) is performed in a column with immobilized Protein G. The antigen–antibody complexes are retained in the column due to the high affinity of the Protein G for the antibody. The activity of the eluted enzyme label is then amperometrically detected.

The immunoassay was optimised relative to conditions for antibody–antigen incubation (pH, incubation time, ionic strength, temperature) and enzymatic label detection. This method showed a dynamic concentration range between 20 and 500 ppt AFM1, a low detection limit (11 ppt), good reproducibility (RSD < 8%) and a high throughput (six samples per hour in triplicate). Different milk samples were analysed and the results were in good agreement with those obtained by HPLC using the AOAC 2000.08 method.  相似文献   


4.
A rapid multi-analyte method has been developed for the simultaneous determination of pesticides and mycotoxins in milk by ultra high-performance liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC–QqQ–MS/MS). A variety of methodologies has been evaluated, including solid-phase extraction (SPE), “dilute-and-shoot” (liquid–liquid extraction-based procedures), and QuEChERS (quick, easy, cheap, effective, rugged, and safe)-based methods. The optimization and development process was carried out considering that the maximum residue level for aflatoxin M1 (AFM1) in milk in the European Union (EU) is set at 0.05 μg kg−1, which is the lowest tolerance in the target compounds. The selected method consisted of an extraction by SPE using C18 as sorbent and methanol as elution solvent. The final determination was performed by UHPLC–QqQ–MS/MS. Matrix-matched standard calibration was used for quantification, obtaining recoveries in the range 60–120% with relative standard deviations <25%, at three spiking levels: 0.5, 10, and 50 μg kg−1 (ten times lower for AFM1). Limits of quantification ranged from 0.20 to 0.67 μg kg−1, which were always below or equal to the established tolerance levels by the EU. Finally, the selected method was applied to different types of milk.  相似文献   

5.
Endosulfan, the last remaining organochlorine pesticide, has been the subject of a number of international regulations and restriction/banning action plans worldwide. Occurrence of endosulfan residues in South Florida environments has been widely described in the literature for more than two decades. This work describes a selective, sensitive, and fast online solid-phase extraction (SPE) method coupled with liquid chromatography separation and tandem mass spectrometry (LC-MS/MS) for the determination of endosulfan isomers and endosulfan sulfate in water samples at low part per trillion levels with very little sample preparation. A negative atmospheric pressure chemical ionization source was carefully optimized to produce reproducible spectra of the target compounds with no adduct ion formation. Selected reaction monitoring transitions were monitored and quantitation was performed against a per-deuterated internal standard β-endosulfan (d4). The automated online SPE clean-up was performed using only 20 mL of untreated water sample prior to LC-MS/MS analysis. The method was capable of separating and quantifying endosulfan within a 24-min run using acetonitrile and water as mobile phases and presenting statistically calculated method detection limits of 3, 10, and 7 ng/L for endosulfan sulfate, α-endosulfan, and β-endosulfan, respectively. In addition, a QuEChERS method was successfully developed and applied for endosulfan determination in sediments/soils, floating and submerged algal mats, and small fish. Minimal matrix effects were observed in all matrices analyzed and recoveries for all analytes ranged from 50–144 %. The developed methodology was applied to monitor the occurrence and to assess the potential transport of endosulfan in the Loveland Slough watershed, an area adjacent to Everglades National Park showing long-term contamination with endosulfans.  相似文献   

6.
Solid-phase extraction (SPE) and reversed-phase liquid chromatography (RP-LC) have been used for simple, sensitive simultaneous analysis of cyromazine and melamine residues in liquid milk and eggs. The conditions used for SPE and LC were investigated and optimized. A combined cation-exchange–reversed-phase cartridge was used for clean-up, and an ODS (C18) column (150 mm × 4.6 mm i.d., 5-μm particles) with 62:38 (v/v) 5 mm sodium lauryl sulfate (pH 3.4)–acetonitrile as mobile phase was used for RP-LC. Under the optimum conditions the method limit of detection (LOD) for both cyromazine and melamine was 6.2 μg kg?1 for liquid milk samples, and 11.5 μg kg?1 for egg samples. Average recovery of cyromazine and melamine from milk samples was 90.3%, RSD 4.6–5.6%, and 99.6%, RSD 3.2–4.7%, respectively. Average recovery of cyromazine and melamine from egg samples was 85.3%, RSD 1.0–4.7%, and 89.6%, RSD 3.1–5.0%, respectively. The method enables detection of melamine and cyromazine at levels as low as 20.7 μg kg?1 in liquid milk and 38.3 μg kg?1 in egg.  相似文献   

7.
Sun  Hanwen  Wang  Lixin  Liu  Na  Qiao  Fengxia  Liang  Shuxuan 《Chromatographia》2009,70(11):1685-1689

Solid-phase extraction (SPE) and reversed-phase liquid chromatography (RP-LC) have been used for simple, sensitive simultaneous analysis of cyromazine and melamine residues in liquid milk and eggs. The conditions used for SPE and LC were investigated and optimized. A combined cation-exchange–reversed-phase cartridge was used for clean-up, and an ODS (C18) column (150 mm × 4.6 mm i.d., 5-μm particles) with 62:38 (v/v) 5 mm sodium lauryl sulfate (pH 3.4)–acetonitrile as mobile phase was used for RP-LC. Under the optimum conditions the method limit of detection (LOD) for both cyromazine and melamine was 6.2 μg kg−1 for liquid milk samples, and 11.5 μg kg−1 for egg samples. Average recovery of cyromazine and melamine from milk samples was 90.3%, RSD 4.6–5.6%, and 99.6%, RSD 3.2–4.7%, respectively. Average recovery of cyromazine and melamine from egg samples was 85.3%, RSD 1.0–4.7%, and 89.6%, RSD 3.1–5.0%, respectively. The method enables detection of melamine and cyromazine at levels as low as 20.7 μg kg−1 in liquid milk and 38.3 μg kg−1 in egg.

  相似文献   

8.
The application of 384-well format solid phase extraction (SPE) for bioanalysis using liquid chromatography/tandem mass spectrometry (LC/MS/MS) is reported and a 384-well SPE method for the 5-HT agonist sumatriptan in human plasma described. Plasma samples were extracted on a prototype low-density polyethylene 384-well SPE block using a packed bed of 5 mg Oasistrade mark HLB. Liquid handling was automated by a combination of a robotic sampler processor and a 96/384 multi-channel dispensing station. Samples and SPE reagents were drawn through the SPE block by centrifugation. The extracts were analysed by LC/MS/MS with thermally and pneumatically assisted electrospray ionisation and selected reaction monitoring. The method is used to illustrate and discuss the feasibility and viability of sample preparation techniques in high-density microtitre plate format for routine bioanalysis.  相似文献   

9.
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples.  相似文献   

10.
建立了牛奶和奶粉中三聚氰酸(CYA)的高效液相色谱-串联质谱(HPLC-MS/MS)测定方法。样品用乙腈提取并沉淀蛋白,经强阴离子交换柱富集和净化,AX色谱柱分离,HPLC-MS/MS法测定,内标法定量。50~2000 μg/L范围内CYA的线性关系良好(r≥0.999);在奶粉和牛奶基质中,添加200、500和1000 μg/kg 3个添加水平的回收率均在97%~121%之间,相对标准偏差(RSD)均小于4.8%;定量限(LOQ)为200 μg/kg。方法的前处理快速简便,净化效果好,准确度和精密度高,可用于牛奶和奶粉中CYA的测定。  相似文献   

11.
A method has been developed and validated for the concurrent extraction, clean‐up, and analysis of polybrominated diphenyl ethers (PBDEs), α‐, β‐, and γ‐hexabromocyclododecane (HBCD), and tetrabromobisphenol A (TBBPA) in human milk and serum. Milk and serum samples were extracted using accelerated solvent extraction with acetone/hexane 1:1, v/v and liquid–liquid extraction with methyl‐tert‐butyl ether/hexane 1:1, v/v, respectively. The removal of co‐extracted biogenic materials was achieved by gel permeation chromatography followed by sulfuric acid treatment. The fractionation of the PBDEs and HBCD/TBBPA was performed using a Supelco LC‐Si SPE cartridge. The detection of the PBDEs was then performed by GC–MS and that of the HBCDs and the TBBPA was performed using UPLC–MS/MS. The pretreatment procedure was optimized, and the characteristic ions and fragmentation of the analytes were studied by MS or MS/MS. A recovery test was performed using a matrix spiking test at concentrations of 0.05–10 ng/g. The recoveries ranged from 78.6–108.8% with RSDs equal to or lower than 14.04%. The LODs were 1.8–60 pg/g. The usefulness of the developed method was tested by the analysis of real human samples, and several brominated flame retardants in different samples were detected and analyzed.  相似文献   

12.
A method using an online solid-phase extraction (SPE) and ion-pairing liquid chromatography with electrospray tandem mass spectrometry (LC/ES-MS/MS) was developed for determination of amphetamine (Amp), methamphetamine (mAmp), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxyethylamphetamine (MDEA), and 3,4-methylenedioxymethamphetamine (MDMA) in urine samples. A SPE cartridge column with both hydrophilic and lipophilic functions was utilized for online extraction. A reversed-phase C18 LC column was employed for LC separation and MS/MS was used for detection. Trifluoroacetic acid was added to the mobile phase as an ion-pairing reagent. This method was fully automated and the extraction and analysis procedures were controlled by a six-port switch valve. Recoveries ranging from 85-101% were measured. Good linear ranges (10-500 ng/mL) for Amp and mAmp were determined. For MDA, MDMA and MDEA, dual linear ranges were obtained from 5-100 and 100-500 ng/mL, respectively. The detection limit of each analytical compound, based on a signal-to-noise ratio of 3, ranged from 1-3 ng/mL. The applicability of this newly developed method was examined by analyzing several urine samples from drug users. Good agreement was obtained between the results from this method and a literature GC/MS method.  相似文献   

13.
Shen  Jianzhong  Zhang  Suxia  Wu  Congming  Jiang  Haiyang  Wang  Zhanhui  Cheng  Linli 《Chromatographia》2010,71(1-2):163-165

A method was developed to simultaneously detect six resorcylic acid lactones in feed by GC–MS. Samples were extracted with methanol followed by a two step liquid–liquid extraction and an HLB SPE clean-up. The samples were derivatized with BSTFA + TMCS (99/1; v/v) and determined by GC–MS. For all analytes, the ranges of recoveries were 81.2–98.2%, with RSDs of 3.2–15.2%, and the LODs were 0.2–0.6 μg kg−1.

  相似文献   

14.
Rapid and sensitive analytical methodology based on ultra high-performance liquid chromatography-tandem mass spectrometry has been developed for the determination of widely consumed drugs of abuse (amphetamines, MDMA, cocaine, opioids, cannabis and ketamine) and their major metabolites in urban wastewaters. Sample clean-up and pre-concentration was performed by a generic off-line SPE procedure using Oasis HLB. Special effort was made to incorporate amphetamine, which was found highly problematic in the wastewater samples tested, including an additional clean-up with Oasis MCX SPE and dispersive primary secondary amine. Correction for possible SPE losses or degradation during storage was made by the use of isotope-labelled internal standards (ILIS), available for all compounds, which were added to the samples as surrogates. Although ILIS were also efficient for matrix effects correction, the strong ionization suppression observed was not eliminated; therefore, a four-fold dilution prior to SPE was applied to influent wastewaters and a low injection volume was selected (3 μL), in order to reach a compromise between matrix effects, chromatographic performance and sensitivity. The method was validated at 25 and 200 ng L?1 (effluent), and 100 and 800 ng L?1 (influent), obtaining limits of quantification (i.e. the lowest level that the compound can be quantified and also confirmed with at least two MS/MS transitions) between 0.4–25 ng L?1 (effluent) and 2–100 ng L?1 (influent). The applicability of the method was demonstrated by analysis of 14 influent and 14 effluent wastewater samples collected over 2 weeks in Castellón (Spain) within a European collaborative study.  相似文献   

15.
A rapid and sensitive analytical method for the simultaneous determination of four fluoroquinolones, four tetracyclines and six sulfonamides in chicken muscle using ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC–MS–MS) has been developed and validated. Samples were extracted with McIlvaine buffer-acetonitrile, defatted with n-hexane, and analyzed by UPLC–MS–MS. Solvent delay technique was applied in the analysis to remove the non-volatile phosphate and carry out farther on-line SPE clean-up. Satisfactory recoveries (55–110%) of all the veterinary drugs were demonstrated in 1, 10 and 20 μg kg?1 spiked levels with the overall RSD for intra- and inter-day of 14 analytes less than 18%. The LOD and LOQ were 0.3 and 1.0 μg kg?1, respectively. Quantitative results of 103 real samples indicated that the present method was suitable for the quantitative analysis of real samples.  相似文献   

16.
The present work describes the development and validation of a sensitive method for the determination of traces of diverse groups of pharmaceuticals and endocrine disruptors in surface water. Thirty-seven substances have been selected, including 10 pesticides, 6 hormonal steroids and assimilates, 12 pharmaceuticals, 5 alkylphenols, 1 chlorophenol and 3 other well-known human contaminants, 1 UV filter and 2 plasticisers. An automated online solid-phase extraction (SPE) is directly coupled to liquid chromatography–tandem mass spectrometry. Different SPE columns have been tested, and the injection volume has been optimised. The developed analytical methodology is based on the direct injection of 2.5 mL of water sample acidified at pH 1.6 on an Oasis HLB loading column (20 × 2.1 mm) with 5-µm particles. Then, the chromatographic separation is achieved on a Kinetex XB C18 (100 × 2.1 mm; 1.7 µm) column, and the quantification is realised in multiple-reaction monitoring mode. The online SPE step warrants minimal sample handling, low solvent consumption, high sample throughput, saving time and costs. This method allows the quantification of the target analytes in the lower ng/L concentration range, with limits of quantification (LQs) between 100 pg/L and 10 ng/L, 26 compounds having LQ lower than 1 ng/L. The monitoring of two selected MS/MS transitions for each compound allows the reliable confirmation of positive findings even at the LQ level. The developed and validated methodology has been applied to the analysis of various real samples from two French rivers. Twelve target compounds have been detected in the environmental samples, and the major pollutants are pharmaceuticals usually used by humans (paracetamol, carbamazepine, oxazepam, ketoprofen, trimethoprim). The pesticides atrazine and carbendazim have been ubiquitously detected in real samples too. Metronidazole, sulfamethoxazole and diuron were also frequently quantified in the water samples.  相似文献   

17.
A new analytical method, using gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) techniques, was developed for the determination in packaged food beverages of five ink photoinitiator residues: 2-isopropylthioxanthone (ITX), benzophenone, 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB), 1-hydroxycyclohexyl-1-phenyl ketone (IRGACURE 184) and ethyl-4-dimethylaminobenzoate (EDAB). Samples were extracted from selected beverages (milk, fruit juices and wine) and relative packagings, using n-hexane and dichloromethane, respectively, purified on solid-phase extraction (SPE) silica gel cartridges, and then analyzed in GC/MS and LC/MS. The recovery percentages, obtained spiking the beverage samples at concentrations of 4 and 10 microgl(-1) with a standard mixture of photoinitiators, were in the range 42-108% (milk), 50-84% (wine), and 48-109% (fruit juices). The repeatability of the method was assessed in all cases by the % of correlation value, that was lower than 19%. The lowest limits of detection (LODs) and limits of quantification (LOQs), obtained using GC/MS, were in the range 0.2-1 and 1-5 microgl(-1), respectively. The method was applied to the analysis of forty packaged food beverages (milk, fruit juices and wine samples). The most significant contamination was that of benzophenone, found in all samples in a concentration range of 5-217mugl(-1). Its presence was confirmed by an LC/Atmospheric-Pressure PhotoIonization (APPI)/MS/MS analysis. The photoinitiator (EHDAB) was found in eleven out of forty beverages in a concentration range of 0.13-0.8 microgl(-1). Less important was the ITX contamination, found in three out of forty samples in a range 0.2-0.24 microgl(-1). The work proposes a new method to analyze ink photoinitiator residues in polycoupled carton packaging and in contained food beverages.  相似文献   

18.
N-(n-butyl) thiophosphoric triamide (NBPT) is a urease inhibitor utilised in urea-based fertilizers. In Ireland, fertilizer treated with NBPT is applied to pasture to mitigate both ammonia and nitrous oxide emissions, but concerns arise as to the potential for residues in milk products. A quick ultrafiltration extraction and ultra-high performance liquid chromatography coupled with mass spectrometry triple quadrupole (UHPLC-MS/MS) quantitation method was developed and validated in this study. The method was applied in the analysis of samples collected from a field study investigating potential transfer of NBPT residues into milk. NBPT and NBPTo residues, were extracted from fortified milk samples and analysed on a UHPLC-MS/MS with recoveries ranging from 74 to 114%. Validation of the UHPLC-MS/MS method at low (0.0020 mg kg−1) and high (0.0250 mg kg−1) concentration levels in line with SANTE/12682/2019 showed overall trueness in the range of 99 to 104% and precision between 1 and 10%, RSD for both compounds. The limit of quantitation (LOQ) was 0.0020 mg kg−1 and other tested parameters (linearity, sensitivity, specificity, matrix effect, robustness, etc.) satisfied acceptance criteria. Stability assessment using spiked samples revealed the compounds were stable in raw and pasteurised milk for 4 weeks at –80 °C storage temperature. Maintaining samples at pH 8.5–9.0 further improved stability. Analysis of 516 milk samples from the field study found that NBPT and NBPTo concentrations were below the LOQ of 0.0020 mg kg−1, thus suggesting very low risk of residues occurring in the milk. The method developed is quick, robust, and sensitive. The method is deemed fit-for-purpose for the simultaneous determination of NBPT and NBPTo in milk.  相似文献   

19.
In this study, tributyltin (TBT) was extracted from marine sediment matrix with the use of pressurised solvent extraction (PSE), which uses high-temperature and -pressure conditions to increase extraction efficiency. The analyte was chromatographically resolved using a liquid chromatography-tandem mass spectrometry (LC-MS/MS) system with a pentafluorophenyl (PFP) column and a methanol/aqueous formic acid mobile phase gradient, and was detected by MS/MS as product fragments after collisionally induced dissociation (CID) of the cationic parent molecule. This study represents the first application of PSE extraction combined with LC-MS/MS analysis for the determination of TBT in sediments. The method has been validated according to the International Organisation for Standardisation (ISO) 17025:2001 and affords automated extraction of sediment samples with high-sensitivity analysis. The full method limit of detection was established as 1.25 ng Sn g?1 with an instrument detection limit of 0.01 ng Sn g?1. The chromatographic procedure may also be applied for the direct analysis of water matrices without the need for sample manipulation, and therefore represents a combined analytical approach for the monitoring of TBT contamination in marine or estuarine ecosystems.  相似文献   

20.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) multiresidue method for the simultaneous quantitative determination of oxytetracycline, 4-epi-oxytetracycline, tetracycline, 4-epi-tetracycline, chlortetracycline, 4-epi-chlortetracycline and doxycycline in milk has been developed. An extraction procedure consisting of a liquid extraction of the milk samples with trichloroacetic acid was performed. The extract was centrifuged and the supernatant was filtered. Solid-phase extraction (SPE) with an OASIS HLB SPE column was used to clean up the sample extracts. The samples were analysed by LC/MS/MS. The LC separation was performed on a reversed-phase C18 column using gradient elution with a mobile phase consisting of water and a mixture of methanol/acetonitrile. The tetracycline analytes were detected with a quadrupole mass spectrometer using positive ion electrospray ionisation. The confirmatory method has acceptable detection limits and the different tetracyclines can be detected at a residue concentration between 5 and 20 microg/L. The method is validated according to the European requirements for veterinary drug residues and all determined parameters were found to conform to the criteria. The recovery values ranged from 90.4 to 101.2% with relative standard deviations (RSDs) no larger than 9.7%. The overall or between-day precision of the analytical assay determined as repeatability at several residue concentrations and expressed as RSD ranged from 3.3 to 10%. This analytical assay is a useful tool within the Belgian monitoring programme for confirmation of samples which have been positively screened for residues of tetracyclines in raw farm cow's milk.  相似文献   