首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
Masked thresholds for a 1000-Hz sinusoidal signal were measured as a function of masker level in both forward and simultaneous masking for two types of maskers: a 1000-Hz sinusoid and a narrowband noise, 60-Hz wide, centered at 1000 Hz. In forward masking, the noise masker produced much steeper growth-of-masking functions than the sinusoid. Presenting a contralateral broadband noise "cue" with the forward masker dramatically reduced the slope of masking for the noise masker but did not influence results for the sinusoidal masker. The noise remained the more effective masker. The amount of masking produced by combinations of equally effective narrowband-noise and sinusoidal maskers was compared to that produced by each masker individually with and without the contralateral cue. No additional masking beyond that predicted by energy summation was measured for forward masking. Additional masking beyond energy-sum predictions was measured for analogous conditions in simultaneous masking. Comparisons of results obtained with and without the contralateral cue suggest that signal thresholds in the presence of narrowband-noise forward maskers can reflect nonperipheral auditory processes.  相似文献   

2.
The present study sought to clarify the role of non-simultaneous masking in the binaural masking level difference for maskers that fluctuate in level. In the first experiment the signal was a brief 500-Hz tone, and the masker was a bandpass noise (100-2000 Hz), with the initial and final 200-ms bursts presented at 40-dB spectrum level and the inter-burst gap presented at 20-dB spectrum level. Temporal windows were fitted to thresholds measured for a range of gap durations and signal positions within the gap. In the second experiment, individual differences in out of phase (NoSπ) thresholds were compared for a brief signal in a gapped bandpass masker, a brief signal in a steady bandpass masker, and a long signal in a narrowband (50-Hz-wide) noise masker. The third experiment measured brief tone detection thresholds in forward, simultaneous, and backward masking conditions for a 50- and for a 1900-Hz-wide noise masker centered on the 500-Hz signal frequency. Results are consistent with comparable temporal resolution in the in phase (NoSo) and NoSπ conditions and no effect of temporal resolution on individual observers' ability to utilize binaural cues in narrowband noise. The large masking release observed for a narrowband noise masker may be due to binaural masking release from non-simultaneous, informational masking.  相似文献   

3.
These experiments examine how comodulation masking release (CMR) varies with masker bandwidth, modulator bandwidth, and signal duration. In experiment 1, thresholds were measured for a 400-ms, 2000-Hz signal masked by continuous noise varying in bandwidth from 50-3200 Hz in 1-oct steps. In one condition, using random noise maskers, thresholds increased with increasing bandwidth up to 400 Hz and then remained approximately constant. In another set of conditions, the masker was multiplied (amplitude modulated) by a low-pass noise (bandwidth varied from 12.5-400 Hz in 1-oct steps). This produced correlated envelope fluctuations across frequency. Thresholds were generally lower than for random noise maskers with the same bandwidth. For maskers less than one critical band wide, the release from masking was largest (about 5 dB) for maskers with low rates of modulation (12.5-Hz-wide low-pass modulator). It is argued that this release from masking is not a "true" CMR but results from a within-channel cue. For broadband maskers (greater than 400 Hz), the release from masking increased with increasing masker bandwidth and decreasing modulator bandwidth, reaching an asymptote of 12 dB for a masker bandwidth of 800 Hz and a modulator bandwidth of 50 Hz. Most of this release from masking can be attributed to a CMR. In experiment 2, the modulator bandwidth was fixed at 12.5 Hz and the signal duration was varied. For masker bandwidths greater than 400 Hz, the CMR decreased from 12 to 5 dB as the signal duration was decreased from 400 to 25 ms.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
Detection thresholds for a tone in an unfamiliar tonal pattern can be greatly elevated under conditions of masker uncertainty [Neff and Green, Percept. Psychophys. 41, 409-415 (1987); Oh and Lutfi, J. Acoust. Soc. Am. 101, 3148 (1997)]. The present experiment was undertaken to determine whether harmonicity of masker tones can reduce the detrimental effect of masker uncertainty. Inharmonic maskers were comprised of m=2-49 frequency components selected at random on each presentation within 100-10000 Hz, excluding frequencies between 920-1080. Harmonic maskers were comprised of frequency components selected at random within this same range, but constrained to have a fundamental frequency of 200 Hz. For inharmonic maskers the signal was a 1000-Hz tone. For harmonic-maskers the signal was a tone whose frequency was either harmonically (1000 Hz) or inharmonically (1047 Hz) related to the masker. In all conditions the amount of masking was greatest for m = 20-40 components. At this point, harmonic maskers with harmonic signal produced an average of 9-12 dB less masking than inharmonic maskers. Harmonic maskers with inharmonic signal produced an average of 16-20 dB less masking.  相似文献   

5.
Psychophysical tuning curves (PTCs) were obtained in simultaneous and forward masking for a 20-ms, 1000-Hz signal presented at 10 dB SL. The signal was presented at the beginning of, at the temporal center of, at the end of, or immediately following a 400-ms masker. The first experiment was done in quiet; the second experiment was done in the presence of two bands of noise on either side of 1000 Hz. The results were similar in quiet and in noise. In simultaneous masking, the PTCs were broadest for the signal at masker onset, and generally sharpest for the signal at temporal center; the differences were largest on the high-frequency side. In most cases, there was virtually no difference in Q10 between the forward-masking PTC and the simultaneous-masking PTC with the signal temporally centered, although the high-frequency slope was always steeper in forward masking. These results indicate that, at least for brief signals, frequency selectivity measured with simultaneous-masking PTCs and the degree of sharpening revealed in forward-masking PTCs depend upon the temporal position of the signal within the simultaneous masker.  相似文献   

6.
The effects of forward masker duration on psychophysical measures of frequency selectivity were investigated in two experiments. In both experiments, masker duration was 50 or 400 ms, signal duration was 20 ms, and there was no delay between masker offset and signal onset. In the first experiment, growth-of-masking functions were measured for a masker whose frequency was below, at, or above the 1000-Hz signal frequency. From those data, input filter patterns (IFPs) were plotted for masker levels from 40-90 dB SPL. In the second experiment, masking patterns (MPs) were measured for a 1000-Hz masker presented at 50, 70, and 90 dB SPL. Both measures of frequency selectivity (IFPs and MPs) indicate that frequency selectivity is greater for the 400-ms masker. These data suggest that there may be a sharpening of frequency selectivity with time at a stage prior to the adaptation observed in forward masking.  相似文献   

7.
In forward masking, performance may be affected by confusion, that is, by the difficulty of discriminating a suprathreshold signal from the preceding masker. This study investigated confusion effects for forward maskers composed of repeated bursts of a 100-Hz sinusoid followed by sinusoidal signals; such "pulsing" maskers produce confusion when the properties of the signal are identical to those of an individual masker "pulse." The level, frequency, and duration of the signal relative to an individual masker pulse, as well as offset-onset delay, were varied to determine the minimum change necessary to eliminate confusion. For maskers composed of 20-ms pulses, confusion was eliminated by changes in signal level of 5 dB or changes in signal frequency of 30 to 40 Hz. For maskers composed of 10-, 20-, or 40-ms pulses, confusion was eliminated by signal delays of 8 to 16 ms or by signal durations less than half or greater than twice the masker-pulse duration. Results with adaptive procedures designed to measure confusion-free or confusion-determined thresholds suggest that confusion effects can be minimized or avoided by extensive listener training with a procedure in which the signal and masker are not presented at similar intensities.  相似文献   

8.
The purpose of this investigation was to examine two stimulus parameters that were reasoned to be of importance to comodulation masking release (CMR). The first was the degree of fluctuation, or depth of modulation, in the masker bands, and the second was the temporal position of the signal with respect to the modulations of the masker. The investigation began by demonstrating the efficacy of sinusoidally amplitude-modulated (SAM) tonal complex maskers in eliciting CMR. "Nine-band" maskers, 650 ms in duration, were constructed by adding together nine SAM tones spaced at 100-Hz intervals from 300 to 1100 Hz. The rate of modulation for each SAM tone was 10 Hz, and the depth of modulation was 100%. Using such maskers, it was shown that when the on-frequency SAM tone had a modulation depth of 100%, the threshold for a 250-ms, 700-Hz tone improved monotonically as the modulation depths of the flanking SAM tones increased from 0% to 100%. When the on-frequency SAM tone had a modulation depth of 63%, some listeners performed optimally when the flanking SAM tones also exhibited a modulation depth of 63%, whereas others performed best when the flankers had modulation depths of 100%. With regard to signal position, a typical CMR effect was observed when the signal, consisting of a train of three 50-ms, 700-Hz tone bursts, was placed in the dips of the on-frequency masker. However, when the signal was placed at the peaks of the envelope, an increase in masking was observed for a comodulated masker.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
"Overshoot" is a simultaneous masking phenomenon: Thresholds for short high-frequency tone bursts presented shortly after the onset of a broadband masker are raised compared to thresholds in the presence of a continuous masker. Overshoot for 2-ms bursts of a 5000-Hz test tone is described for four subjects as a function of the spectral composition and level of the masker. First, it was verified that overshoot is largely independent of masker duration. Second, overshoot was determined for a variety of 10-ms masker bursts composed of differently filtered uniform masking noise with an overall level of 60 dB SPL: unfiltered, high-pass (cutoff at 3700 Hz), low-pass (cutoff at 5700 Hz), and third-octave-band-(centered at 5000 Hz) filtered uniform masking noises presented separately or combined with different bandpass maskers (5700-16000 Hz, 5700-9500 Hz, 8400-16000 Hz) were used. Third, masked thresholds were measured for maskers composed of an upper or lower octave band adjacent to the third-octave-band masker as a function of the level of the octave band. All maskers containing components above the critical band of the test tone led to overshoot; no additional overshoot was produced by masker components below it. Typical values of overshoot were on the order of 12 dB. Overshoot saturated when masker levels were above 60 dB SPL for the upper octave-band masker. The standard neurophysiological explanation of overshoot accounts only partially for these data. Details that must be accommodated by any full explanation of overshoot are discussed.  相似文献   

10.
In this paper previous experiments on auditory filter shapes in binaural masking experiments [A. Kohlrausch, J. Acoust. Soc. Am. 84, 573-583 (1988)] are extended to a wider range of masker and signal durations. The masker was a dichotic broadband noise with frequency-dependent interaural parameters. The interaural phase difference of the masker was 0 below 500 Hz and pi above 500 Hz. Signal frequency varied between 200 and 800 Hz, and the signal was presented either monaurally (Sm) or binaurally in antiphase (S pi). In the first experiment, the masker duration was fixed at 500 ms and signals of 250 and 20 ms were used. In the second experiment, the signal duration was fixed at 20 ms, and the masker duration was reduced to 25 ms. The results from both experiments are consistent with studies using No or N pi maskers: The binaural masking level difference (BMLD) increases slightly for shorter test signals and decreases strongly for short maskers. The BMLD patterns of the first experiment are well described by the auditory-filter model derived for stationary test signals, if the additional influence of "off-frequency listening" for the short test signal is taken into account. The BMLDs resulting from the second experiment (25-ms masker), however, are much lower than predicted by this filter model This outcome supports previous observations that binaural unmasking becomes less effective for very short masker durations and indicates that this effect is even stronger for maskers with a complex structure of interaural parameters.  相似文献   

11.
We compare psychophysical tuning curves obtained with sinusoidal and narrow-band (50-Hz wide) noise maskers in both simultaneous and forward masking. In one experiment, we examine the effects of different combinations of duration and intensity of the 1-kHz sinusoidal signal. In a second experiment, we compare tuning curves obtained with a sinusoidal signal to those obtained with a noise signal. In both experiments, a narrow-band noise is a more effective simultaneous masker than a sinusoid for masker frequencies near the signal frequency. We argue that this is probably due to the use of different detection cues in the presence of sinusoidal and noise maskers, and that the greater masking produced by the noise is not simply due to its greater variability. As observed in other studies, tuning curves are narrower in forward masking than in simultaneous masking.  相似文献   

12.
When more than one sinusoid is used as a masker, more masking is observed than would be predicted by a simple combination of their individual effects. This masking is dramatically increased when the masker components vary in frequency and intensity with each presentation. These studies manipulated several masker parameters under conditions of high masker uncertainty, examining the effect of excluding critical-band components, fixing or randomizing component amplitudes and frequencies, and narrowing the frequency range of the components. The signal was always a 200-ms, 1000-Hz sinusoid, presented simultaneously with the 200-ms masker. Removing critical-band components reduced the amount of masking, but considerable masking remained that appears to be nonperipheral in origin. Fixing masker frequencies across the two intervals of a trial greatly reduced the masking observed, whereas fixing masker amplitudes had no effect. Reducing the frequency range from 5000 to 2700 Hz generally increased the masking observed, but appeared to depend on other masker parameters. Summaries across ten listeners show individual differences that are resistant to extensive training. It is difficult to account for most of the masking observed in terms of masker energy falling near the region of the signal.  相似文献   

13.
To assess age-related differences in benefit from masker modulation, younger and older adults with normal hearing but not identical audiograms listened to nonsense syllables in each of two maskers: (1) a steady-state noise shaped to match the long-term spectrum of the speech, and (2) this same noise modulated by a 10-Hz square wave, resulting in an interrupted noise. An additional low-level broadband noise was always present which was shaped to produce equivalent masked thresholds for all subjects. This minimized differences in speech audibility due to differences in quiet thresholds among subjects. An additional goal was to determine if age-related differences in benefit from modulation could be explained by differences in thresholds measured in simultaneous and forward maskers. Accordingly, thresholds for 350-ms pure tones were measured in quiet and in each masker; thresholds for 20-ms signals in forward and simultaneous masking were also measured at selected signal frequencies. To determine if benefit from modulated maskers varied with masker spectrum and to provide a comparison with previous studies, a subgroup of younger subjects also listened in steady-state and interrupted noise that was not spectrally shaped. Articulation index (AI) values were computed and speech-recognition scores were predicted for steady-state and interrupted noise; predicted benefit from modulation was also determined. Masked thresholds of older subjects were slightly higher than those of younger subjects; larger age-related threshold differences were observed for short-duration than for long-duration signals. In steady-state noise, speech recognition for older subjects was poorer than for younger subjects, which was partially attributable to older subjects' slightly higher thresholds in these maskers. In interrupted noise, although predicted benefit was larger for older than younger subjects, scores improved more for younger than for older subjects, particularly at the higher noise level. This may be related to age-related increases in thresholds in steady-state noise and in forward masking, especially at higher frequencies. Benefit of interrupted maskers was larger for unshaped than for speech-shaped noise, consistent with AI predictions.  相似文献   

14.
The purpose of this report is to present new data that provide a novel perspective on temporal masking, different from that found in the classical auditory literature on this topic. Specifically, measurement conditions are presented that minimize rather than maximize temporal spread of masking for a gated (200-ms) narrow-band (405-Hz-wide) noise masker logarithmically centered at 2500 Hz. Masked detection thresholds were measured for brief sinusoids in a two-interval, forced-choice (21FC) task. Detection was measured at each of 43 temporal positions within the signal observation interval for the sinusoidal signal presented either preceding, during, or following the gating of the masker, which was centered temporally within each 500-ms observation interval. Results are presented for three listeners; first, for detection of a 1900-Hz signal across a range of masker component levels (0-70 dB SPL) and, second, for masked detection as a function of signal frequency (fs = 500-5000 Hz) for a fixed masker component level (40 dB SPL). For signals presented off-frequency from the masker, and at low-to-moderate masker levels, the resulting temporal masking functions are characterized by sharp temporal edges. The sharpness of the edges is accentuated by complex patterns of temporal overshoot and undershoot, corresponding with diminished and enhanced detection, respectively, at both masker onset and offset. This information about the onset and offset timing of the gated masker is faithfully represented in the temporal masking functions over the full decade range of signal frequencies (except for fs=2500 Hz presented at the center frequency of the masker). The precise representation of the timing information is remarkable considering that the temporal envelope characteristics of the gated masker are evident in the remote masking response at least two octaves below the frequencies of the masker at a cochlear place where little or no masker activity would be expected. This general enhancement of the temporal edges of the masking response is reminiscent of spectral edge enhancement by lateral suppression/inhibition.  相似文献   

15.
Fastl and Bechly [J. Acoust. Soc. Am. 74, 754-757 (1983)] reported that the threshold of a brief 900-Hz signal simultaneously masked by a band of noise. 100 Hz wide, centered at 1000 Hz, was reduced by approximately 8 dB by the addition of an 1150-Hz tone having a level of 20 dB above that of the narrow-band masker. They concluded that this decrease in threshold was a demonstration of suppression in simultaneous masking. Here it is argued that Fastl and Bechly's results simply reflect the poorer detectability of signals masked by higher-frequency fluctuating maskers (their narrow-band masker) than by relatively flat-envelope maskers (their composite narrow-band plus tonal masker). The results of three experiments support the masker-envelope explanation. In the first experiment, as in the report of Fastl and Bechly, the masker centered at 1000 Hz (M1) was a narrow-band noise and the masker centered at 1150 Hz (M2) was a tone. Fastl and Bechly's result was replicated. However, thresholds obtained when M1 was presented alone (the M1-only condition) were more affected by the starting level of the signal within each adaptive track than were thresholds obtained when M1 and M2 were presented together (the M1+M2 condition). This result paralleled a previous report that starting level influenced performance more with fluctuating than with flat-envelope maskers. For the four of seven subjects wh showed learning, there was also more improvement in the M1-only than in the M1 + M2 condition. In the second experiment, M1 was a tone and M2 was a narrow-band noise.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
Previous studies have shown that threshold for a signal in tone-on-tone simultaneous masking is sometimes lower when the masker is continuous than when it is gated. Threshold may also decline as signal onset is delayed relative to the onset of a longer duration masker, though it may increase again near masker offset. In the present study, the level of a 1250-Hz sinusoidal masker was found which would just mask a 20-ms, 1000-Hz sinusoid presented at 10-dB sensation level (SL). Masker duration was 20 or 400 ms; in the latter case, the signal was presented in one of three temporal positions within the masker. The level of the 1250-Hz masker necessary to mask the signal was reduced, sometimes by as much as 20-25 dB, by a 20-ms, 500-Hz sinusoid (transient masker) presented at the times when the signal might occur, but at a level 30 dB below that at which it would mask the 10-dB SL signal. This suggests that, in the earlier studies, at least some of the elevation in threshold in the presence of a short-duration masker or at the beginning (or end) of a longer duration masker may have been due to the transient responses to the masker affecting detection of the signal, but not necessarily masking the signal in terms of excitation in the signal "channel."  相似文献   

17.
Psychometric functions (PFs) for forward-masked tones were obtained for conditions in which signal level was varied to estimate threshold at several masker levels (variable-signal condition), and in which masker level was varied to estimate threshold at several signal levels (variable-masker condition). The changes in PF slope across combinations of masker frequency, masker level, and signal delay were explored in three experiments. In experiment 1, a 2-kHz, 10-ms tone was masked by a 50, 70 or 90 dB SPL, 20-ms on-frequency forward masker, with signal delays of 2, 20, or 40 ms, in a variable-signal condition. PF slopes decreased in conditions where signal threshold was high. In experiments 2 and 3, the signal was a 4-kHz, 10-ms tone, and the masker was either a 4- or 2.4-kHz, 200-ms tone. In experiment 2, on-frequency maskers were presented at 30 to 90 dB SPL in 10-dB steps and off-frequency maskers were presented at 60 to 90 dB SPL in 10-dB steps, with signal delays of 0, 10, or 30 ms, in a variable-signal condition. PF slopes decreased as signal level increased, and this trend was similar for on- and off-frequency maskers. In experiment 3, variable-masker conditions with on- and off-frequency maskers and 0-ms signal delay were presented. In general, the results were consistent with the hypothesis that peripheral nonlinearity is reflected in the PF slopes. The data also indicate that masker level plays a role independent of signal level, an effect that could be accounted for by assuming greater internal noise at higher stimulus levels.  相似文献   

18.
The present study was a follow-up to a pilot study in which it was found that a 500-Hz-wide narrow-band noise (NBN) masker produced more masking than a tonal (T) masker for signal frequencies both above and below the masker frequency. The aim of the present study was to determine to what extent these results were influenced by an interaction of the relatively rapid temporal envelope fluctuations of the NBN and the short (10-ms) duration of the signal. In the first experiment, the masking produced by a regular NBN, a low-noise noise (LNN), and a T was compared. The LNN produced less masking than the NBN, and about as much as the T, suggesting that the inherent amplitude fluctuations in the NBN were largely responsible for the greater masking produced by that masker. In the second experiment, the masking produced by a regular NBN was compared with that by a T for a signal duration of 10 or 200 ms. The difference in masking between the two maskers was reduced or eliminated when the signal duration was 200 ms, because the threshold in the presence of the NBN masker decreased more with increasing signal duration. This could reflect a decreased "confusion" between the signal and the inherent fluctuations of the NBN masker.  相似文献   

19.
Psychophysical estimates of compression often assume that the basilar-membrane response to frequencies well below characteristic frequency (CF) is linear. Two techniques for estimating compression are described here that do not depend on this assumption at low CFs. In experiment 1, growth of forward masking was measured for both on- and off-frequency pure-tone maskers for pure-tone signals at 250, 500, and 4000 Hz. The on- and off-frequency masking functions at 250 and 500 Hz were just as shallow as the on-frequency masking function at 4000 Hz. In experiment 2, the forward masker level required to mask a fixed low-level signal was measured as a function of the masker-signal interval. The slopes of these functions did not differ between signal frequencies of 250 and 4000 Hz for the on-frequency maskers. At 250 Hz, the slope for the 150-Hz masker was almost as steep as that for the on-frequency masker, whereas at 4000 Hz the slope for the 2400-Hz masker was much shallower than that for the on-frequency masker. The results suggest that there is substantial compression, of around 0.2-0.3 dB/dB, at low CFs in the human auditory system. Furthermore, the results suggest that at low CFs compression does not vary greatly with stimulation frequency relative to CF.  相似文献   

20.
Modulation masking: effects of modulation frequency, depth, and phase   总被引:1,自引:0,他引:1  
Modulation thresholds were measured for a sinusoidally amplitude-modulated (SAM) broadband noise in the presence of a SAM broadband background noise with a modulation depth (mm) of 0.00, 0.25, or 0.50, where the condition mm = 0.00 corresponds to standard (unmasked) modulation detection. The modulation frequency of the masker was 4, 16, or 64 Hz; the modulation frequency of the signal ranged from 2-512 Hz. The greatest amount of modulation masking (masked threshold minus unmasked threshold) typically occurred when the signal frequency was near the masker frequency. The modulation masking patterns (amount of modulation masking versus signal frequency) for the 4-Hz masker were low pass, whereas the patterns for the 16- and 64-Hz maskers were somewhat bandpass (although not strictly so). In general, the greater the modulation depth of the masker, the greater the amount of modulation masking (although this trend was reversed for the 4-Hz masker at high signal frequencies). These modulation-masking data suggest that there are channels in the auditory system which are tuned for the detection of modulation frequency, much like there are channels (critical bands or auditory filters) tuned for the detection of spectral frequency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号