首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chen Z  Ozawa H  Uchiyama K  Hobo T 《Electrophoresis》2003,24(15):2550-2558
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.  相似文献   

2.
以苯基三乙氧基硅烷(PTES)和1,4-双三乙氧基硅基苯(BTEB)为反应单体,分别采用盐酸和十二胺为催化剂,通过两步酸碱催化的溶胶-凝胶法制备了新型双苯基杂化硅胶毛细管电色谱整体柱。分别采用扫描电镜、红外光谱和压汞法对材料的结构特性进行了表征。结果表明,所制备的材料具有特定的网络结构特征,孔径主要分布在3.4μm左右,材料的总孔容为3.5 cm3/g,比表面积为145 m2/g。新型整体柱能够很好地分离烷基取代苯、稠环芳烃、取代苯胺和硝基苯酚异构体。整体柱重复性实验表明,6种苯的同系物保留时间和容量因子的相对标准偏差分别小于0.61%和0.30%(n=8)。不同批次的整体柱的保留时间和容量因子的相对标准偏差分别小于7.2%和5.6%(n=3)。  相似文献   

3.
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Both the mesopore and macropore diameters of the monolithic column are decisive for the column efficiency. As the diameter of the through-pores decreases, the column efficiency increases. The large set of mesopores studied with a nominal diameter of approximately 25 nm provided the most efficient column performance. The efficiency of the monolithic silica columns increase with decreasing n-alkyl chain length in the sequence of C18相似文献   

4.
The mesopores of a monolithic silica column are very important and useful for chromatographic separation since they can offer sufficiently large surface area. In this paper, a novel method with the assistance of an ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate ([bmin]BF4)) was developed for the preparation of a C18-modified monolithic silica column for the first time, in which, the through pores and mesopores were formed simultaneously during the sol-gel reaction. The method is effective to simplify the preparation process of the silica-based monolithic columns. The factors influencing the sol-gel process, including the content of methanol and pH, were studied. The chromatographic performance of the prepared monolithic column was evaluated by the separation of alkylbenzenes.  相似文献   

5.
在2.2mm内径的石英管中,采用正硅酸四乙酯水解的溶胶-凝胶法合成了填充细石英砂的高比表面积电色谱整体柱,并用正辛基三乙氧基硅烷键合制备反相色谱固定相.填充细石英砂的电色谱整体柱抑制了大柱径引起的电流热效应,采用电渗流驱动流动相,分离了苯酚和苯,实验证明该整体微柱用于电色谱分离和改善浓度检出限的可行性.  相似文献   

6.
Monolithic columns of 2.7 mm I.D. have been prepared and used in electrochromatography (EC) separation. Although capillary electrochromatography (CEC) has higher separation efficiency, it displays some shortcomings, such as limited sample loadability and restricted concentration detectability etc. In this paper, we investigate the feasibility of EC separation with millimeter diameter monolithic columns. By using a designed preparation method of monolithic column packed with about 150 microm quartz sand, the effect of Joule heating can be reduced, and the processes of frit making and column packing can be avoided. The concentration detectability of the EC is improved comparing with that of CEC. Moreover, the separation efficiency of 52,000 plates/m was achieved with a 70 mm length and 2.7 mm I.D. monolithic column.  相似文献   

7.
In this work a new type of chiral monolith silica column was developed for the chiral separation by micro high-performance liquid chromatography (micro-HPLC). The chiral monolith column with a continuous skeleton and a large through-pore structure was prepared inside a capillary of 100 microm I.D. by a sol-gel process, and chemically modified with chiral selectors, such as L-phenylalaninamide, L-alaninamide and L-prolinamide, on the surface of the monolithic silica column. Based on the principle of ligand exchange, these chiral monolithic columns were successfully used for the separation of dansyl amino acid enantiomers, as well as hydroxy acid enantiomers by micro-HPLC. The chromatographic conditions, the enantioselectivity and the performance of columns are discussed.  相似文献   

8.
研究了硅胶整体柱的制备工艺及温度、pH对凝胶化过程的影响,探讨了不同的四甲氧基硅烷/聚乙二醇比例、不同制也剂浓度对柱结构的影响,以及不同焙烧温度和酸活化处理方法对柱体Si0H含量和线性收缩率的影响,由此确定最佳制备条件。结果表明,采用改进的溶胶-凝胶工艺制备的硅胶整体柱,无开裂变形现象;不同制备条件,可以产生具有不同微米级鞍形骨架、微米级大孔和纳米级中孔的整体柱,可适合不同物质的分离和分析。  相似文献   

9.
Cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) is an excellent chiral selector for enantioseparation of a wide variety of chiral compounds. The monolithic chiral columns are becoming popular in liquid chromatography and capillary electrochromatography. In this work, we present the fast separation of chiral β-blockers on a CDMPC-modified zirconia monolithic column by capillary electrochromatography (CEC). The porous zirconia monolithic capillary column was prepared by using the sol-gel technology and then zirconia surface modified with CDMPC. The enantioseparations were performed in reversed-phase (RP) eluents of a phosphate solution (pH 4.4) modified with acetonitrile or alcohol. The enantioseparations of a set of eight chiral β-blockers were achieved in less than one minute. Influences of the applied voltage, column temperature, concentration of acetonitrile and the type of alcohol as the organic modifier in the mobile phase, and sample injection time on enantioseparation were investigated. CEC separations at the applied voltage of 10 kV and 15 °C in the ACN-modified mobile phase provided the best resolutions for the analytes studied. Run-to-run and day-to-day repeatabilities of the column in the RP-CEC separation were less than 1 and 2%, respectively.  相似文献   

10.
Monolithic columns have been prepared with a novel bonded silica stationary phase, tetradecylamine bonded silica (TDAS), and used in pressurized capillary electrochromatography (pCEC). The monolithic silica column matrix was prepared by a sol-gel process and then chemically modified with the spacer (3-glycidoxypropyl)trimethoxysilane and tetradecylamine. The introduced embedded polar amine groups dominated the charge on the surface of the monolithic stationary phase and generated an EOF from cathode to anode under acidic conditions. The tetradecyl hydrophobic chains in TDAS provide chromatographic interactions. The chromatographic characteristics of the prepared monolithic column were studied. Some aromatic compounds including alkylbenzenes, aromatic hydrocarbons, phenols, and anilines were successfully separated on the TDAS monolithic column in pCEC mode. As expected, the TDAS monolithic stationary phases exhibit typical reversed-phase electrochromatographic behavior toward neutral solutes due to the introduced tetradecyl groups. Hydrophobic as well as electrophoretic migration processes within the monoliths were observed in the separation of basic anilines. Symmetrical peaks can be obtained for anilines because the embedded polar amine groups on the surface can effectively shield the adsorption of positively charged analytes onto the stationary phase.  相似文献   

11.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

12.
Monolithic silica columns with surface-bound octadecyl (C18) moieties have been prepared by a sol-gel process in 100 microm ID fused-silica capillaries for reversed-phase capillary electrochromatography of neutral and charged species. The reaction conditions for the preparation of the C18-silica monoliths were optimized for maximum surface coverage with octadecyl moieties in order to maximize retention and selectivity toward neutral and charged solutes with a sufficiently strong electroosmotic flow (> 2 mm/s) to yield rapid analysis time. Furthermore, the effect of the pore-tailoring process on the silica monoliths was performed over a wide range of treatment time with 0.010 M ammonium hydroxide solution in order to determine the optimum time and conditions that yield mesopores of narrow pore size distribution that result in high separation efficiency. Under optimum column fabrication conditions and optimum mobile phase composition and flow velocity, the average separation efficiency reached 160 000 plates/m, a value comparable to that obtained on columns packed with 3 microm C18-silica particles with the advantages of high permeability and virtually no bubble formation. The optimized monolithic C18-silica columns were evaluated for their retention properties toward neutral and charged analytes over a wide range of mobile phase compositions. A series of dimensionless retention parameters were evaluated and correlated to solute polarity and electromigration property. A dimensionless mobility modulus was introduced to describe charged solute migration and interaction behavior with the monolithic C18-silica in a counterflow regime during capillary electrochromatography (CEC )separations. The mobility moduli correlated well with the solute hydrophobic character and its charge-to-mass ratio.  相似文献   

13.
溶胶-凝胶法制备毛细管硅胶整体柱的研究进展   总被引:3,自引:0,他引:3  
陈雅顺  贾丽 《分析化学》2008,36(6):853-859
毛细管硅胶整体柱作为一种新型的分离介质,在色谱领域显示出了强大的生命力。本评述介绍了溶胶-凝胶法制备毛细管硅胶整体柱的方法,重点分析了溶胶-凝胶法制备毛细管硅胶整体柱的影响因素,总结了近几年毛细管硅胶整体柱在高效液相色谱和电色谱中的应用。  相似文献   

14.
A silica-bonded bovine serum albumin (BSA) chiral monolithic stationary phase for capillary electrochromatography(CEC) was introduced. An inorganic-organic hybrid monolithic column was firstly prepared by sol-gel chemistry with homogeneously distributed aminopropyl groups throughout the silica matrix. Then the chiral stationary phase was synthesized by the in situ covalent immobilization of BSA on the monolithic column activated with glutaraldehyde. The effects of pH value and concentration of phosphate buffer on the separation of D,L-tryptophan were investigated. The separation factor of D,L-tryptophan reached 3.37 on CEC mode.  相似文献   

15.
有机-无机杂化硅胶基质整体柱的制备及其电色谱性能   总被引:1,自引:1,他引:0  
采用溶胶-凝胶法,以四乙氧基硅烷和苯基三乙氧基硅烷作为反应单体,通过酸碱两步催化在毛细管中进行原位缩聚反应,制备了新型有机-无机杂化硅胶基质毛细管整体柱,制备过程简单。整体柱基质中均匀分布的苯基基团可直接用于反相毛细管电色谱的分离,因而不需要对基质再进行衍生化。优化了整体柱的制备条件,采用扫描电镜和压汞法对整体柱的微观结构和孔径分布进行了表征。分别考察了溶胶-凝胶初始反应液中水的用量对柱床结构的影响和两种单体的配比对材料孔径分布的影响。研究了稠环芳烃类化合物在整体柱上的保留行为,用所制备的整体柱分离了7种苯酚类化合物,平均柱效达100000塔板/m。  相似文献   

16.
采用溶胶-凝胶技术制备了丁基胺丙基硅胶毛细管整体柱,此整体固定相表面同时含有能产生阳极的电渗流的仲胺官能团和产生疏水作用的正丁基和丙基官能团。对所制备的整体柱电色谱性能进行了详细的表征和分析。考察了流动相pH值对电渗流的影响;对烷基苯同系物、有机酸酸性化合物和苯胺类碱性化合物保留行为进行了研究,并对其可能的保留机理进行了探讨。实验结果表明,对于中性化合物的保留机理主要基于反相作用;而对于酸性化合物的保留行为则是基于混合模式作用机理,即除了电泳作用外,还包括阴离子交换和疏水作用。碱性化合物在丁基胺丙基硅胶毛细管整体柱上的峰形较好,没有明显的峰拖尾现象。  相似文献   

17.
Yan L  Zhang Q  Zhang W  Feng Y  Zhang L  Li T  Zhang Y 《Electrophoresis》2005,26(15):2935-2941
A novel hybrid organic-inorganic silica-based monolithic column possessing phenyl ligands for reversed-phase (RP) capillary electrochromatography (CEC) is described. The monolithic stationary phase was prepared by in situ co-condensation of tetraethoxysilane (TEOS) with phenyltriethoxysilane (PTES) via a two-step catalytic sol-gel procedure to introduce phenyl groups distributed throughout the silica matrix for chromatographic interaction. The hydrolysis and condensation reactions of precursors were chemically controlled through pH variation by adding hydrochloric acid and dodecylamine, respectively. The structural property of the monolithic column can be easily tailored through adjusting the composition of starting sol solution. The effect of PTES/TEOS ratios on the morphology of the created stationary phases was investigated. A variety of neutral and basic analytes were used to evaluate the column performance. The CEC columns exhibited typical RP chromatographic retention mechanism for neutral compounds and had improved peak shape for basic solutes.  相似文献   

18.
We developed a novel, convenient and low-cost one-pot strategy for preparing a zeolitic imidazolate framework-8 (ZIF-8)–silica hybrid monolithic column by adding ZIF-8 directly to a polymer solution of the silica matrix. The simulated stationary phase and monolithic column prepared under optimal conditions were characterized using X-ray diffraction, scanning electron microscopy, Fourier-transform infrared spectroscopy, thermogravimetric analysis nitrogen physisorption and zeta potential. The results obtained confirmed the successful introduction of ZIF-8 into the silica monolithic column, and the prepared monolithic column exhibited good permeability and physicochemical stability. A capillary electrochromatography method was developed based on a ZIF-8–silica hybrid monolithic column through which 15 mixed amino acids, 4 neutral compounds, 4 nipagin esters and 2 chlorinated fungicides were separated in 14, 5, 7 and 6 min, respectively, under optimal conditions. The relative standard deviations retention times and column efficiencies in run-to-run, day-to-day and column-to-column varied in the ranges of 1.90%–2.21%, 2.13%–2.51% and 3.08%–6.65%, respectively, which demonstrated that ZIF-8–silica hybrid monolithic column exhibited satisfactory reproducibility and stability. The incorporation of ZIF-8 into a silica monolithic column is a promising method for preparing novel monolithic columns composed of a metal–organic framework.  相似文献   

19.
An organic-inorganic hybrid monolithic column based on 1-vinyl-3-dodecylimidazolium bromide (VC12Im+Br?) has been prepared in a single step by combining radical copolymerization with a non-hydrolytic sol-gel (NHSG) process. The NHSG process was significantly shortened to 6 h by using formic acid as catalyst. For comparison, we also prepared polymeric ionic liquid (PIL) monolithic columns by hydrolytic sol-gel and organic polymeric process, respectively. The resulting monolithic columns were characterized by Fourier transform infrared spectra, scanning electron microscopy, and Brunauer-Emmett-Teller. Under the capillary electrochromatography mode, these columns were applied to separate alkylbenzenes, anilines, and proteins, respectively. The results indicated that the NHSG-based hybrid PIL monolithic column exhibited the highest column efficiency among the three types of columns; organic solvent, commonly required by the traditional columns to achieve satisfactory separation efficiency for proteins, was absent in the NHSG-based hybrid PIL monolithic column because of the biocompatibility of the VC12Im+Br?, which was beneficial to analysis of protein containing samples. In order to demonstrate its application potential, the developed NHSG-based hybrid PIL monolithic column was also employed to separate egg white sample.  相似文献   

20.
A novel single-step sol-gel approach for the preparation of beta-CD-bonded silica monolithic electrochromatographic columns is established. The porous silica networks were fabricated inside fused-silica capillaries using sol-gel processing of tetramethoxysilane and an organfunctional silicon alkoxide that contains beta-CD. Scanning electron micrographs and nitrogen adsorption-desorption data showed that these functional monolithic columns have double pores structures with micrometer-size co-continuous through-pores and silica skeletons with open mesopores. The beta-CD monolithic columns have successfully been applied to the separation of several neutral and negatively charged isomers by CEC. The column performance was evaluated by using positional isomers of naphthalenedisulfonic acid as model compounds. A plate height of less than 10 mum for the first eluted isomer of naphthalenedisulfonic acid was obtained at an optimal flow rate (0.47 mm/s) of the mobile phase. Moreover, the columns have been proved to be stable for more than 100 runs during 3 months period and show reasonable column reproducibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号