首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhang H  Nie S  Etson CM  Wang RM  Walt DR 《Lab on a chip》2012,12(12):2229-2239
This paper describes a novel method for fabricating and sealing high-density arrays of femtoliter reaction chambers. We chemically etch one end of a 2.3 mm diameter glass optical fiber bundle to create an array of microwells. We then use a contact printing method to selectively modify the surface of the material between microwells with a hydrophobic silane. This modification makes it possible to fill the wells with aqueous solution and then seal them with a droplet of oil, forming an array of isolated reaction chambers. Individual β-galactosidase molecules trapped in these reaction chambers convert a substrate into a fluorescent product that can be readily detected because a high local concentration of product is achieved. This binary readout can be used for ultra-sensitive measurements of enzyme concentration. We observed that the percentage of wells showing enzyme activity was linearly dependent on the concentration of soluble β-galactosidase in the picomolar range. A similar response was also observed for streptavidin-β-galactosidase captured by biotinylated beads. These arrays are also suitable for performing single-molecule kinetics studies on hundreds to thousands of enzyme molecules simultaneously. We observed a broad distribution of catalytic rates for individual β-galactosidase molecules trapped in the microwells, in agreement with previous studies using similar arrays that were mechanically sealed. We have further demonstrated that this femtoliter fiber-optic array can be integrated into a PDMS microfluidic channel system and sealed with oil on-chip, creating an easy to use and high-throughput device for single-molecule analysis.  相似文献   

2.
We report a method for isolating individual paramagnetic beads in arrays of femtolitre-sized wells and detecting single enzyme-labeled proteins on these beads using sequential fluid flows in microfabricated polymer array assemblies. Arrays of femtolitre-sized wells were fabricated in cyclic olefin polymer (COP) using injection moulding based on DVD manufacturing. These arrays were bonded to a complementary fluidic structure that was also moulded in COP to create an enclosed device to allow delivery of liquids to the arrays. Enzyme-associated, paramagnetic beads suspended in aqueous solutions of enzyme substrate were delivered fluidically to the array such that one bead per well was loaded by gravity. A fluorocarbon oil was then flowed into the device to remove excess beads from the surface of the array, and to seal and isolate the femtolitre-sized wells containing beads and enzyme substrate. The device was then imaged using standard fluorescence imaging to determine which wells contained single enzyme molecules. The analytical performance of this device as the detector for digital ELISA compared favourably to the standard method, i.e., glass arrays mechanically sealed against a silicone gasket; prostate specific antigen (PSA) could be detected from 0.011 pg mL(-1) up to 100 pg mL(-1). The use of an enclosed fluidic device to isolate beads in single-molecule arrays offers a multitude of advantages for low-cost manufacturing, ease of automation, and instrument development to enable applications in biomarker validation and medical diagnosis.  相似文献   

3.
Sakakihara S  Araki S  Iino R  Noji H 《Lab on a chip》2010,10(24):3355-3362
The enzyme assay in a femtoliter chamber array is a simple and efficient method for concentrating the reaction product; it greatly improves the detection sensitivity down to the single-molecule level. However, in previous methods, controlling the initiation and termination of the reaction in each chamber is difficult once enclosed. Furthermore, the recovery of the enzyme and product is also difficult. To overcome these drawbacks, we developed a femtoliter droplet array in which the individual droplets are fixed on the substrate and are directly accessible from outside. A hydrophilic-in-hydrophobic micropatterned surface was used for the preparation of the droplets. When the aqueous solution on the surface is exchanged with oil, the hydrophilic surface retains the aqueous solution, and more than 10(6) dome-shaped droplets that are usable for further assay can be prepared simultaneously. The curvature radius of the droplet obeys the Young-Laplace equation, and the volume can be precisely controlled by the micropipette, which applies pressure into the droplet. Changing the pressure makes the addition, collection, and exchange of the aqueous content for individual droplets possible. Using these advantages, we successfully measured the kinetic parameters of the single-molecule enzyme β-galactosidase and rotary motor protein F(1)-ATPase enclosed in a droplet.  相似文献   

4.
High-throughput preparation of multi-component solutions is an integral process in biology, chemistry and materials science for screening, diagnostics and analysis. Compact microfluidic systems enable such processing with low reagent volumes and rapid testing. Here we present a microfluidic device that incorporates two gradient generators, a tree-like generator and a new microfluidic active injection system, interfaced by intermediate solution reservoirs to generate diluted combinations of input solutions within an 8 × 8 or 10 × 10 array of isolated test chambers. Three input solutions were fed into the device, two to the tree-like gradient generator and one to pre-fill the test chamber array. The relative concentrations of these three input solutions in the test chambers completely characterized device behaviour and were controlled by the number of injection cycles and the flow rate. Device behaviour was modelled by computational fluid dynamics simulations and an approximate analytic formula. The device may be used for two-dimensional (2D) combinatorial dilution by adding two solutions in different relative concentrations to each of its three inputs. By appropriate choice of the two-component input solutions, test chamber concentrations that span any triangle in 2D concentration space may be obtained. In particular, explicit inputs are given for a coarse screening of a large region in concentration space followed by a more refined screening of a smaller region, including alternate inputs that span the same concentration region but with different distributions. The ability to probe arbitrary subspaces of concentration space and to control the distribution of discrete test points within those subspaces makes the device of potential benefit for high-throughput cell biology studies and drug screening.  相似文献   

5.
Biomolecule encapsulation in droplets is important for miniaturizing biological assays to reduce reagent consumption, cost and time of analysis, and can be most effectively achieved by using microfabricated devices. Microfabricated fluidic devices can generate emulsified drops of uniform size with controlled dimensions and contents. Biological and chemical components such as cells, microgels, beads, hydrogel precursors, polymer initiators, and other droplets can be encapsulated within these drops. Encapsulated emulsions are appealing for a variety of applications since drops can be used as tiny reaction vessels to perform high-throughput reactions at fast rates, consuming minimal sample and solvent amounts due to the small size (micron diameters) of the emulsion drops. Facile mixing and droplet coalescence allow for a diversity of assays to be performed on-chip with tunable parameters. The simplicity of operation and speed of analysis with microencapsulated drops lends itself well to an array of quantitative biomolecular studies such as directed evolution, single-molecule DNA amplification, single-cell encapsulation, high-throughput sequencing, enzyme kinetics, and microfluidic cell culture. This review highlights recent advances in the field of microfabricated encapsulating devices, emphasizing the development of emulsifying encapsulations, device design, and current assays that are performed using encapsulating droplets.  相似文献   

6.
Kim J  Taylor D  Agrawal N  Wang H  Kim H  Han A  Rege K  Jayaraman A 《Lab on a chip》2012,12(10):1813-1822
We describe the development of a fully automatic and programmable microfluidic cell culture array that integrates on-chip generation of drug concentrations and pair-wise combinations with parallel culture of cells for drug candidate screening applications. The device has 64 individually addressable cell culture chambers in which cells can be cultured and exposed either sequentially or simultaneously to 64 pair-wise concentration combinations of two drugs. For sequential exposure, a simple microfluidic diffusive mixer is used to generate different concentrations of drugs from two inputs. For generation of 64 pair-wise combinations from two drug inputs, a novel time dependent variable concentration scheme is used in conjunction with the simple diffusive mixer to generate the desired combinations without the need for complex multi-layer structures or continuous medium perfusion. The generation of drug combinations and exposure to specific cell culture chambers are controlled using a LabVIEW interface capable of automatically running a multi-day drug screening experiment. Our cell array does not require continuous perfusion for keeping cells exposed to concentration gradients, minimizing the amount of drug used per experiment, and cells cultured in the chamber are not exposed to significant shear stress continuously. The utility of this platform is demonstrated for inducing loss of viability of PC3 prostate cancer cells using combinations of either doxorubicin or mitoxantrone with TRAIL (TNF-alpha Related Apoptosis Inducing Ligand) either in a sequential or simultaneous format. Our results demonstrate that the device can capture the synergy between different sensitizer drugs and TRAIL and demonstrate the potential of the microfluidic cell array for screening and optimizing combinatorial drug treatments for cancer therapy.  相似文献   

7.
We analyze how functionality could be obtained within single-molecule devices by using a combination of non-equilibrium Green's functions and ab initio calculations to study the inelastic transport properties of single-molecule junctions. First, we apply a full non-equilibrium Green's function technique to a model system with electron-vibration coupling. We show that the features in the inelastic electron tunneling spectra (IETS) of the molecular junctions are virtually independent of the nature of the molecule-lead contacts. Since the contacts are not easily reproducible from one device to another, this is a very useful property. The IETS signal is much more robust versus modifications at the contacts and hence can be used to build functional nanodevices. Second, we consider a realistic model of a organic conjugated molecule. We use ab initio calculations to study how the vibronic properties of the molecule can be controlled by an external electric field which acts as a gate voltage. The control, through the gate voltage, of the vibron frequencies and (more importantly) of the electron-vibron coupling enables the construction of functionality: nonlinear amplification and/or switching is obtained from the IETS signal within a single-molecule device.  相似文献   

8.
We developed a system to reversibly encapsulate small numbers of molecules in an array of nanofabricated "dimples". This system enables highly parallel, long-term, and attachment-free studies of molecular dynamics via single-molecule fluorescence. In studies of bimolecular reactions of small numbers of confined molecules, we see phenomena that, while expected from basic statistical mechanics, are not observed in bulk chemistry. Statistical fluctuations in the occupancy of sealed reaction chambers lead to steady-state fluctuations in reaction equilibria and rates. These phenomena are likely to be important whenever reactions happen in confined geometries.  相似文献   

9.
Adhesion of platelets to blood vessel walls is a shear stress dependent process that promotes arrest of bleeding and is mediated by the interaction of receptors expressed on platelets with various extracellular matrix (ECM) proteins that may become exposed upon vascular injury. Studies of dynamic platelet adhesion to ECM-coated substrates in conventional flow chambers require substantial fluid volumes and are difficult to perform with blood samples from a single laboratory mouse. Here we report dynamic platelet adhesion assays in two new microfluidic devices made of PDMS. Small cross-sections of the flow chambers in the devices reduce the blood volume requirements to <100 microl per assay, making the assays compatible with samples of whole blood obtained from a single mouse. One device has an array of 8 flow chambers with shear stress varying by a factor of 1.93 between adjacent chambers, covering a 100-fold range from low venous to arterial. The other device allows simultaneous high-resolution fluorescence imaging of dynamic adhesion of platelets from two different blood samples. Adhesion of platelets in the devices to three common ECM substrate coatings was verified to conform with published results. The devices were subsequently used to study the roles of extracellular and intracellular domains of integrin alphaIIbbeta3, a platelet receptor that is a central mediator of platelet aggregation and thrombus formation. The study involved wild-type mice and two genetically modified mouse strains and showed that the absence of the integrin impaired adhesion at all shear stresses, whereas a mutation in its intracellular domain reduced the adhesion only at moderate and high stresses. Because of small sample volumes required, the devices could be employed in research with genetically-modified model organisms and for adhesion tests in clinical settings with blood from neonates.  相似文献   

10.
电化学门控已成为一种可行且高效调节单分子电导的方法.在本研究中,我们证实了具有两个平行苯环的单分子电路中电子传输可以通过电化学门控控制.首先,我们利用STM-BJ技术以金为电极构筑了具有两条平行路径的单分子结.与单条路径的单分子结相比,两条路径的分子结由于具有增强性量子干涉效应,具有2.82倍的电导值.进一步地,我们利...  相似文献   

11.
High-density microfluidic arrays for cell cytotoxicity analysis   总被引:12,自引:0,他引:12  
In this paper, we report on the development of a multilayer elastomeric microfluidic array platform for the high-throughput cell cytotoxicity screening of mammalian cell lines. Microfluidic channels in the platform for cell seeding are orthogonal to channels for toxin exposure, and within each channel intersection is a circular chamber with cell-trapping sieves. Integrated, pneumatically-actuated elastomeric valves within the device isolate the microchannel array within the device into parallel rows and columns for cell seeding and toxin exposure. As a demonstration of the multiplexing capability of the platform, a microfluidic array containing 576 chambers was used to screen three cell types (BALB/3T3, HeLa, and bovine endothelial cells) against a panel of five toxins (digitonin, saponin, CoCl(2), NiCl(2), acrolein). Evaluation of on-chip cell morphology and viability was carried out using fluorescence microscopy, with outcomes comparable to microtiter plate cytotoxicity assays. Using this scalable platform, cell seeding and toxin exposure can be carried out within a single microfluidic device in a multiplexed format, enabling high-density parallel cytotoxicity screening while minimizing reagent consumption.  相似文献   

12.
Park S  Kim D  Mitchell RJ  Kim T 《Lab on a chip》2011,11(17):2916-2923
We present a microfabricated concentrator array device that makes it possible to quantify the predation rate of Bdellovibrio bacteriovorus, a predatory microbe, toward its prey, Escherichia coli str. MG1655. The device can accumulate both prey and predator microbes sequentially within a series of concentrator arrays using the motility of the microbes and microfabricated arrowhead-shaped ratchet structures. Since the device can constrain both prey and predator cells within 200 pL chambers at a desired range of cell densities, it was demonstrated that the device cannot only enhance the possibility of studying predation processes/cycles directly at a single cell level but can also quantify the predation rates indirectly by measuring the time-dependent fluorescent intensity signals from the prey. Furthermore, the device can produce a wide range of initial prey to predator density ratios within various concentrator arrays through the use of microfluidic mixer structures on a single array chip, which allows us to study many different conditions with a single set of cultures, and quantitatively characterize the predation behaviour/rate. Lastly, we note that this novel concentrator array device can be a very powerful tool facilitating studies of microbial predations and microbe-microbe interaction and may be broadly used in other microbial biotechnological applications.  相似文献   

13.
A variety of electronic DNA array devices and techniques have been developed that allow electric field enhanced hybridization to be carried out under special low-conductance conditions. These devices include both planar microelectronic DNA array/chip devices as well as electronic microtiter plate-like devices. Such "active" electronic devices are able to provide controlled electric (electrophoretic) fields that serve as a driving force to move and concentrate nucleic acid molecules (DNA/RNA) to selected microlocation test-sites on the device. In addition to ionic strength, pH, temperature and other agents, the electric field provides another controllable parameter that can affect and enhance DNA hybridization. With regard to the planar microelectronic array devices, special low-conductance buffers were developed in order to maintain rapid transport of DNA molecules and to facilitate hybridization within the constrained low current and voltage ranges for this type of device. With regard to electronic microtiter plate type devices (which do not have the low current/voltage constraints), the use of mixed buffers (low conductance upper chamber/high conductance lower chamber) can be used in a unique fashion to create favorable hybridization conditions in a microzone within the test site location. Both types of devices allow DNA molecules to be rapidly and selectively hybridized at the array test sites under conditions where the DNA in the bulk solution can remain substantially denatured.  相似文献   

14.
构建了一种基于渗透脱水模式的自动进样微流控结晶芯片. 该芯片通过真空预脱气将包含蛋白质和结晶剂的液滴自动分配至结晶微腔阵列中, 然后利用集成的一排包含不同浓度盐溶液的透析管道, 通过渗透脱水方式经一层聚二甲基硅氧烷(PDMS)膜实现液滴的逐渐浓缩, 使之趋于过饱和状态, 进而形成结晶. 此芯片可一次筛选较宽范围的过饱和状态, 实现蛋白质结晶的快速优化. 利用模式蛋白溶菌酶的结晶实验验证了该芯片的性能.  相似文献   

15.
An asymmetrical system involving glucose oxidase immobilized on the surface of a porous collagen membrane was studied. The enzyme was bound on only one side of a membrane used to separate two chambers of a diffusion cell. The volumes of these chambers were very different, and the medium in each chamber could be stirred independently. With the enzyme adjacent to the larger chamber, monitoring the building up of product in the two chambers revealed that the concentration was always higher in the receiving chamber than in the donating chamber, where the reaction occurred. This phenomenon can be explained by the high concentration of product in the immobilized enzyme microenvironment and by the role played by the diffusion layer existing close to the membrane in the reaction chamber affecting product flux-splitting. The thickness of this layer and the product concentration at the enzyme level were calculated for several hydrodynamic conditions in the enzymatic chamber. The ratio of product concentration in both chambers may become larger than 10 and was found to be dependent on the thickness of the diffusion layer. These findings should be useful for the design of reaction-separation bioreactors and could tentatively be used to explain some interface phenomena in compartmented reactions occurring in vivo.  相似文献   

16.
Wang X  Chen X  Ma X  Kong X  Xu Z  Wang J 《Talanta》2011,84(2):565-571
A novel fluid mixing strategy was developed which significantly enhanced the efficiency of DNA hybridization. A pneumatic micro-mixing device consisting of two pneumatic chambers and an underneath DNA microarray chamber was built up. The fluid in the array chamber was pneumatically pumped alternately by the two pneumatic chambers. The chaotic oscillatory flow caused by the pumping greatly intensified the fluidic mixing. A homogeneous distribution of the tracer dye solution in the microarray chamber was observed after 2 s mixing with a pumping frequency of 24 Hz. Microarray DNA hybridization was substantially accelerated using this device, and the fluorescence intensity showed a plateau after oscillating 30 s at room temperature. The corresponding signal level of the dynamic hybridization was 12.5-fold higher than that of the static hybridization performed at 42 °C. A signal-to-noise ratio of 117 was achieved and the nonspecific adsorption of the targets to the sample array was minimized, which might be attributed to the strong shearing force generated during the pneumatic mixing process.  相似文献   

17.
The development of a chip-based sensor array composed of individually addressable polystyrene-poly(ethylene glycol) and agarose microspheres has been demonstrated. The microspheres are selectively arranged in micromachined cavities localized on silicon wafers. These cavities are created with an anisotropic etch and serve as miniaturized reaction vessels and analysis chambers. A single drop of fluid provides sufficient analysis media to complete approximately 100 assays in these microetch pits. The cavities possess pyramidal pit shapes with trans-wafer openings that allows for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microspheres. Identification and quantitation of analytes occurs via colorimetric and fluorescence changes to receptor and indicator molecules that are covalently attached to termination sites on the polymeric microspheres. Spectral data are extracted from the array efficiently using a charge-coupled device allowing for the near-real-time digital analysis of complex fluids. The power and utility of this new microbead array detection methodology is demonstrated here for the analysis of complex fluids containing a variety of important classes of analytes including acids, bases, metal cations, metabolic cofactors, and antibody reagents.  相似文献   

18.
Kim L  Vahey MD  Lee HY  Voldman J 《Lab on a chip》2006,6(3):394-406
We present a microfluidic device for culturing adherent cells over a logarithmic range of flow rates. The device sets flow rates through four separate cell-culture chambers using syringe-driven flow and a network of fluidic resistances. The design is easy to fabricate with no on-chip valves and is scalable both in the number of culture chambers as well as in the range of applied flow rates. Using particle velocimetry, we have characterized the flow-rate range. We have also demonstrated an extension of the design that combines the logarithmic flow-rate functionality with a logarithmic concentration gradient across the array. Using fluorescence measurements we have verified that a logarithmic concentration gradient was established in the extended device. Compared with static cell culture, both devices enable greater control over the soluble microenvironment by controlling the transport of molecules to and away from the cells. This approach is particularly relevant for cell types such as embryonic stem cells (ESCs) which are especially sensitive to the microenvironment. We have demonstrated for the first time culture of murine ESCs (mESCs) in continuous, logarithmically scaled perfusion for 4 days, with flow rates varying >300x across the array. Cells grown in the slowest flow rate did not proliferate, while colonies grown in higher flow rates exhibited healthy round morphology. We have also demonstrated logarithmically scaled continuous perfusion culture of 3T3 fibroblasts for 3 days, with proliferation at all flow rates except the slowest rate.  相似文献   

19.
Biological assays at the single molecule level are crucial to fundamental studies of DNA-protein mechanisms. In order to cater for high throughput applications, one area of immense research potential is single-molecule bioassays where miniaturized devices are developed to perform rapid and effective biological reactions and analyses. With the success of various emerging technologies for engineering miniaturized structures down to the nanoscale level, supported by specialized equipment for detection, many investigations in the field of life science that were once thought impossible can now be actively explored. In this review, the significance of downscaling to the single-molecule level is firstly presented in selected examples, with the focus placed on restriction enzyme assays. To determine the effectiveness of single-molecule restriction enzyme reactions, simple and direct analytical methods based on DNA stretching have often been reliably employed. DNA stretching can be realized based on a number of working principles related to the physical forces exerted on the DNA samples. We then discuss two examples of a nanochannel system and a microchamber system where single-molecule restriction enzyme digestion and DNA stretching have been integrated, which possess prospective capabilities of developing into highly sensitive and high-throughput restriction enzyme assays. Finally, we take a brief look at the general trends in technological development in this field by comparing the advantages and disadvantages of performing assays at bulk, microscale and single-molecule levels. Figure Minaturization of Restriction Enzyme Assays and DNA Stretching  相似文献   

20.
An interdigitated electrode array (IDEA) device has been designed and used to transport DNA based on a Brownian ratchet mechanism. This migration is produced by the periodic formation of an asymmetric sawtooth electric field in the device. Oligonucleotides of 25, 50, and 100 bases in length were tested using two different array geometries. DNA transport as a function of DNA size, electric field frequency, and array geometry is shown to be in qualitative agreement with theory. Such a device could provide for DNA separations over a broad size range, and can be readily scaled as a component in a microfabricated DNA analysis system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号