首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper reports the results of an optimisation study for a procedure to determine the total selenium and its inorganic species, Se(IV) and Se(VI) using atomic absorption spectrometry combined with hydride generation and in-situ trapping of the analyte on the inner walls of the graphite tube. With the use of the proposed modification, a detection limit (3σ) of 0.018 ng/ml is achieved. This paper presents exemplary results, according to the proposed procedure, for selenium determination in samples of marine water. The concentrations of selenium in the samples ranged from <0.02 ng/ml to 0.16ng/ml of Se(IV) and from <0.02 ng/ml to 0.10 ng/ml of Se(VI).  相似文献   

2.
Safavi A  Mirzaee M 《Talanta》2000,51(2):225-230
A sensitive catalytic kinetic spectrofluorimetric method for determining ng ml(-1) of selenium by flow injection analysis has been developed. The method, based on the catalytic effect of Se (IV) on the reduction of resorufin by sulphide, in the presence of cetylpyridinium chloride, is monitored spectrofluorimetrically (lambda(ex)=480 nm; lambda(em)=583 nm). The linearity range of the calibration graph is dependent on the concentration of sulphide. The variables affecting the rate of the reaction were investigated. The method is simple, rapid, precise, sensitive, and widely applicable. The limit of detection is 1 ng ml(-1) Se (IV), and the calibration range is 5-1000 ng ml(-1). Sampling rate is 60 samples h(-1), and the relative standard deviation of 12 determinations of 100 ng ml(-1) Se was 0.76%. The determination of Se (IV) in the presence of Se (VI) and total selenium is described. The method was applied to the determination of Se in selenium tablets, and several synthetic samples.  相似文献   

3.
In this work, a reliable method is described for speciation of soluble inorganic selenium ions, Se(IV) and Se(VI), which combines an uptake process by using living bacterial cells and electrothermal atomic absorption spectrometry (ETAAS). A selective retention of either Se(IV) or Se(IV) plus Se(VI) can be carried out by using the uptake system made up of either Pseudomonas putida or Escherichia coli strains cultivated in a culture medium based on glucose (P. putida) and glucose plus dipotassium phosphate (E. coli) mixed together with the original sample solution containing the selenium species. Discrimination between inorganic selenium species is possible by combining the optimization of the bacterial cell, the growth conditions and the relative rates of their retention from the sample. In the general procedure, an equilibrium between the analyte in the solution and the uptake system is allowed to be established, and then the concentration of selenium is determined directly in the biomass by slurry sampling ETAAS. Nonetheless, a theoretical model is proposed to describe the retention process by the living bacterial cells, which also provides a feasible quantification of the extraction process before the adsorption equilibrium is reached and whenever the agitation conditions and the sampling time are under control. The detection limits for the inorganic selenium species at the best retention conditions are of 5.7 ng Se(IV) ml(-1) for P. putida and 6.1 ng Se(IV) ml(-1) and 6.3 ng Se(VI) ml(-1) for E. coli. The relative standard deviations of the adsorption/determination process are 2.9-6.3%.  相似文献   

4.
The total selenium and selenium(IV) contents in sea water and river water can be determined directly by a gas chromatographic method with l,2-diamino-3,5-dibromobenzene without preconcentration. The reagent reacts only with selenium(IV) to form a 4,6-dibromopiazselenol; other oxidation states of selenium must therefore be converted to the tetravalent state for total selenium determinations. The piazselenol formed can be extracted quantitatively into 1 ml of toluene from 500 ml of sample water. A method is proposed for the determination of selenium(IV) and total selenium in natural waters at levels as low as 2 ng l-1. Coastal sea water and river water in Japan contain 8–30 ng of Se(IV) and 20–50 ng of total Se per liter.  相似文献   

5.
Afkhami A  Safavi A  Massoumi A 《Talanta》1992,39(8):993-996
A method is presented for the determination of selenium, based on the catalytic effect of selenium(IV) on the reduction reaction of BrO(-)(3) by N(2)H(4).2HCl. The decolourization of Methyl Orange by the reaction products was used to monitor the reaction spectrophotometrically at 525 nm. This method is precise, highly sensitive, simple, rapid, widely applicable and selective for the determination of selenium(IV) and total selenium. The variables which affected the reaction rate were fully investigated and the optimum conditions were established. Selenium, as low as 1 ng/ml, can be determined by this method. The relative standard deviation of 20 ng of selenium was 0.94% (N = 10). The method was applied to the determination of Se(IV) in a health-care product.  相似文献   

6.
The extraction behaviour of selenium(IV) and selenium(VI) with sodium diethyldithiocarbamate, ammonium pyrrolidinedithiocarbamate and dithizone in organic solvents has been investigated by means of flameless atomic-absorption spectrophotometry with a carbon-tube atomizer. The selective extraction of selenium(IV) and differential determination of selenium(IV) and selenium(VI) have been developed. With sodium diethyldithiocarbamate and carbon tetrachloride, when the aqueous phase/organic solvent volume ratio is 5 and the injection volume in the carbon tube is 20 microl, the sensitivity for selenium is 0.4 ng/ml for 1% absorption. The relative standard deviations are ca. 3%. Interference by many metal ions can he prevented by masking with EDTA. The proposed methods have been applied satisfactorily to determination of Se(IV) and Se(VI) in various types of water.  相似文献   

7.
A simple, rapid and sensitive flow injection spectrophotometric method for determination of selenium (0.005-1.5 mug ml(-1)) is described. The method is based on the catalytic effect of Se(IV) on the reduction reaction of thionine (TN) with sulphide ion, monitored spectrophotometrically at 598 nm. The detection limit is 5 ng ml(-1) the relative standard deviation for eight replicate measurements is 1.1% for 1 mug ml(-1) of selenium. The sampling rate is 25-30 samples h(-1). The procedure was applied successfully to the determination of selenium in real samples.  相似文献   

8.
Afkhami A  Madrakian T 《Talanta》2002,58(2):311-317
A simple, accurate, sensitive and selective method is described for rapid determination of ultra-trace quantities of selenium. Selenium (IV) was collected on activated carbon after reduction to elemental Se by l-ascorbic acid. The collected selenium was then determined based on its accelerating effect on the oxidation reaction of methyl orange with bromate in acidic media. Total amount of Se(IV) and Se(VI) were collected on AC after their reduction by hydrazine. Se(IV), Se(VI) and total selenium could be determined by the method. Selenium in the range 10-10 000 ng could be determined by the method. The method was used to the determination of Se(IV), Se(VI) and total selenium in natural water with satisfactory results.  相似文献   

9.
Yu MQ  Liu GQ  Jin Q 《Talanta》1983,30(4):265-270
A novel procedure for determination of trace As(III) and As(V), Sb(III) and Sb(V), Se(IV) and Se(VI), Te(IV) and Te(VI) in water by atomic-absorption spectrophotometry after separation and enrichment with "thiol cotton" and hydride generation has been established. The sorption behaviour of various oxidation states of arsenic, antimony, selenium and tellurium, and the conditions of quantitative sorption and desorption of these species were studied. The procedures for reducing species from higher oxidation states were optimized. Interferences from other species and their elimination were investigated. The selectivity of the procedure for the determination of species in higher and lower oxidation states was examined. The procedure has been successfully used to determine arsenic, antimony, selenium and tellurium in water, in the range from pg ml to ng ml . The recoveries for added spikes were in the range 90-110%, with coefficients of variation in the range 3-8%  相似文献   

10.
A flow injection system has been developed consisting of on-line preconcentration of selenium species in a microcolumn filled with activated alumina, reduction of Se(VI) to Se(IV) and determination by HG-AAS. When 0.01 mol/L HNO3 is used both as carrier and activation reagent for the alumina microcolumn, up to 150 ng of Se(IV) and Se(VI) can be preconcentrated and quantitatively eluted by 500 L of 2 mol/L NH3. The preconcentration factor is 50 when 25 mL of sample is used. The detection limit is about 6 ng/L, the precision is 5% for low concentrations such as 150 ng/L and 3% at high concentrations such as 120 ng/mL. The proposed method is suitable for natural water samples and inorganic Se speciation can be performed by determining Se(IV) and total selenium [Se(VI) is evaluated from the difference].  相似文献   

11.
A sensitive kinetic spectrophotometric method has been developed for the determination of Se(IV) over the range of 45 to 4000 ng in 10 mL of solution. The method is based on the catalytic effect of Se(IV) on the reduction reaction of bromate by hydrazinium dichloride, with subsequent reaction of Ponceau S with products of the above reaction (chlorine and bromine), causing color changing of Ponceau S. Method development includes optimization of time interval for measurement of slope, pH, reagents concentration, and temperature. The optimized conditions yielded a theoretical detection limit of 33 ng/?10 mL of solution of Se(IV). The interfering effects were studied and removed. The method was applied to the determination of selenium in spiked water, Kjeldahl tablet, selenium tablet, and shampoo. Vanadium(V) has an inhibition effect on the catalyzed reaction of bromate and hydrazine by selenium. Using this effect, V(V) can be determined in the range of 70 to 2500 ng in 10 mL of solution. The optimization procedure includes pH and selenium concentration. An extraction method was used for interference removal. The method was applied to the determination of vanadium in petroleum. Received: 20 October 1998 / Revised: 17 April 1999 / Accepted: 3 June 1999  相似文献   

12.
Zhang B  Xu H  Yu JC 《Talanta》2002,57(2):323-331
A new analytical method has been developed for the determination of total gaseous selenium in the atmosphere by honeycomb denuder collection followed by differential pulse cathodic stripping voltammetry (DPCSV) measurement. Gaseous selenium was collected in a denuder coating solution containing 2% HNO(3) and 2% glycerine. The soluble product, selenious acid, was then extracted by water for DPCSV analysis. The collection efficiency for gaseous selenium was 99.1% at a flow rate of 1 l min(-1) for 3 h. Excellent linearity in DPCSV was maintained up to Se concentration of 40 ng ml(-1). This was equivalent to a working concentration of 220 ng m(-3) of selenium in the atmosphere. A precision of 1.26% RSD (n=5) for 5 ng Se was obtained, and the detection limit (3sigma) and the quantitative determination limit were estimated to be 0.96 and 3.19 ng m(-3). The average recovery of selenium in three standard samples prepared by independent digestion of NIST SRM 1648 (Urban Particulate Matter) using our analytical system was 99.0%. The total content of gaseous selenium in the atmosphere of our laboratories was 3.2-4.4 ng m(-3).  相似文献   

13.
《Analytical letters》2012,45(14):2871-2885
ABSTRACT

The catalytic effect of Se(IV) on the reduction reaction of thionine(TN) by sulfide ion is used for determination of trace amounts of selenium(IV) ion by a kinetic-spectrophotometric method. This new method is simple and highly sensitive. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the reaction mixture at 598 nm. The fixed time method was used for the first 45s from initiation of the reaction. Under the optimum conditions, in the concentration range of 2-90 ng ml? of selenium(IV), a quite linear regression equation (r = 0.9984, n = 14) was obtained. The experimental detection limit of the method (S/N = 3) was 1.3 ng ml?. The relative standard deviation of ten replicate measurements is 2.51% for a 40 ng ml? solution of selenium. The proposed method is used to the study of selenium (IV,VI) speciation in water at ng ml? levels. This method was extended for the determination of selenium in real samples.  相似文献   

14.
A sensitive kinetic spectrophotometric method has been developed for the determination of Se(IV) over the range of 45 to 4000 ng in 10 mL of solution. The method is based on the catalytic effect of Se(IV) on the reduction reaction of bromate by hydrazinium dichloride, with subsequent reaction of Ponceau S with products of the above reaction (chlorine and bromine), causing color changing of Ponceau S. Method development includes optimization of time interval for measurement of slope, pH, reagents concentration, and temperature. The optimized conditions yielded a theoretical detection limit of 33 ng/¶10 mL of solution of Se(IV). The interfering effects were studied and removed. The method was applied to the determination of selenium in spiked water, Kjeldahl tablet, selenium tablet, and shampoo. Vanadium(V) has an inhibition effect on the catalyzed reaction of bromate and hydrazine by selenium. Using this effect, V(V) can be determined in the range of 70 to 2500 ng in 10 mL of solution. The optimization procedure includes pH and selenium concentration. An extraction method was used for interference removal. The method was applied to the determination of vanadium in petroleum.  相似文献   

15.
A kinetic-spectrophotometric method for the simultaneous determination of Se(IV) and Te(IV) is described. The method is based upon the catalytic effect of these cations on the reaction of toluidine blue with sulfide. Partial least squares calibration method was employed for the data manipulation and analysis. The concentrations were varied between 0.02-0.24 and 0.01-0.08 μg/ml for Se(IV) and Te(IV), respectively. Cross-validation method was used to select the optimum number of factors (NF). The root mean square errors of difference for selenium and tellurium were 1.2 and 1.7 μg/ml, respectively. Application of the method to artificial samples and several mixtures of standard solutions of Se(IV) and Te(IV) were performed and satisfactory results were obtained.  相似文献   

16.
A new method based on cloud point extraction (CPE) separation and electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICPMS) detection has been proposed for the speciation of inorganic selenium in environmental waters. When the temperature of the system is higher than the cloud point temperature (CPT) of the selected surfactant Triton X-114, the complex of Se(IV) with ammonium pyrrolidine dithiocarbamate (APDC) seems to be extracted into the surfactant-rich phase, whereas the Se(VI) remains in aqueous solutions. Thus, an in situ separation of Se(IV) and Se(VI) could be realized. The concentrated analyte was introduced into the ETV-ICP mass spectrometer for determination of Se((IV) after dilution with 200 microL methanol. Se(VI) was reduced to Se(IV) prior to determining total selenium, and its assay was based on subtracting Se(IV) from total selenium. The main factors affecting the CPE and the vaporization behavior of the analyte were investigated in detail. Under the optimized experimental conditions, the limit of detection (LOD) for Se(IV) was 8.0 ng/L with an enhancement factor of 39 when 10 mL of sample solution was preconcentrated to 0.2 mL. The relative standard deviation (RSD) was found to be 3.9% (C(Se(IV)) = 1.0 microg/L, n = 7). The proposed method was applied to the speciation of inorganic selenium in different environmental water samples with the recovery for the spiked samples in the range of 82-102%.  相似文献   

17.
A novel, fast, and cheap nonchromatographic method for direct speciation of dissolved inorganic and organic selenium species in environmental and biological samples was developed by flow injection (FI) dual-column preconcentration/separation on-line coupled with ICP-MS determination. In the developed technique, the first column packed with nanometer-sized Al(2)O(3) could selectively adsorb the inorganic selenium [Se(IV), Se(VI)], and the retained inorganic selenium could be eluted by 0.2 mol l(-1) NaOH, while the organic Se [selenocystine (SeCys(2)) and selenomethionine (Se-Met)] was not retained. On the other hand, the second column packed with mesoporous TiO(2) chemically modified by dimercaptosuccinic acid (DMSA) could selectively adsorb Se(IV) and SeCys(2) and barely adsorb Se(VI) and Se-Met. When the sample solution was passed through the column 1, separation of inorganic selenium and organic selenium could be achieved first. Then, the effluent from column 1 was successively introduced into the column 2 and the speciation of organic selenium could be attained due to the different adsorption behaviors of Se-Met and SeCys(2) on DMSA modified TiO(2). After that, the eluent from column 1 contained Se(IV), and Se(VI) was adjusted to desired pH and injected into column 2, and the speciation of Se(IV) and Se(VI) could also be realized thanks to their different retention on column 2. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. The detection limits obtained for Se(IV), Se(VI), Se-Met and SeCys(2) were 45-210 ng l(-1) with precisions of 3.6-9.7%. The proposed method has been successfully applied for the speciation of dissolved inorganic and organic selenium in environmental and biological samples. In order to validate the methodology, the developed method was also applied to the speciation of selenium in certified reference material of SELM-1 yeast, and the determined values were in good agreement with the certified values.  相似文献   

18.
A sensitive catalytic method for determining ng ml? concentration of selenium is described. The method is based on the catalytic action of Se(IV) on the reduction of resazurin by sulphide, monitored spectrophotometrically at 605 nm. The linearity range of the calibration graph is dependent on the concentration of sulphide. The variables affecting the rate of the reaction were investigated and the optimum conditions were established. The method is simple, rapid, precise, sensitive and widely applicable. As low as 8.0 × 10?4 μg ml?1 of selenium can be determined. The relative standard deviation of seven determination of 10 ng Se was 0.7%. The determination of Se(IV) in the presence of Se(VI) and the determination of total selenium are also described.  相似文献   

19.
Mattsson G  Nyholm L  Olin A  Ornemark U 《Talanta》1995,42(6):817-825
An analytical method was developed for the determination of total dissolved selenium in fresh waters, using linear sweep cathodic stripping voltammetry (CSV) in combination with UV photolytic digestion. Both the CSV method, based on the electrodeposition and stripping of Cu(2)Se, and the UV irradiation procedure were investigated in detail. In the presence of dissolved organic substances, as in freshwaters, Se(VI) is reduced to Se(IV) by UV irradiation in 0.1M hydrochloric acid. Glucose can be used as the carbon source in samples low in natural dissolved organic carbon (DOC). The photolytic yields of Se(IV) were about 90% in both cases. Five freshwater samples were analysed for total selenium by CSV after UV photolysis, and by hydride generation atomic absorption spectrometry (HG-AAS) after oxidative digestion followed by reduction with hydrochloric acid. The results agreed well and the concentrations were in the range 70-190 ng/l., well above the detection limit of the CSV method at 2 ng/l.  相似文献   

20.
Elemental selenium and tellurium, and gaseous inorganic forms of Se(IV), Se(VI), Te(IV) and Te(VI) have been determined after their adsorption on gold-coated beads. After leaching, with water and dilute hydrochloric and nitric acids, the different chemical species in each acid fraction were separated with an anion-exchange resin (Bio-Rad AG-1X8) and a cation-exchange resin (Amberlite IR-120 Plus) by varying the acidity of the leaching agent. Subsequent analysis was by graphite-fumace atomic-absorption spectrometry. The lower detection limit for Se and Te was 0.03 ng/M(3) with a precision of +/- 5%. The average amounts of selenium in interior and exterior air samples were about 4.73 and 1.93 ng/m(3) respectively. For tellurium the corresponding values were about 0.78 and 0.24 ng/m(3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号